Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-22276207

RESUMO

ImportanceDiabetes has been reported to be associated with an increased risk of death among patients with COVID-19. However, available studies lack detail on COVID illness severity and measurement of relevant comorbidities. Design, Setting, and ParticipantsWe conducted a multicenter, retrospective cohort study of patients over the age of 18 years who were hospitalized with COVID-19 between January 1, 2020 and November 30, 2020 in Ontario, Canada and Copenhagen, Denmark. Chart abstraction emphasizing co-morbidities and disease severity was performed by trained research personnel. The association between diabetes and death was measured using Poissson regression. Main Outcomes and Measureswithin hospital 30-day risk of death. ResultsOur study included 1018 hospitalized patients with COVID-19 in Ontario and 305 in Denmark, of whom 405 and 75 patients respectively had pre-existing diabetes. In both Ontario and Denmark, patients with diabetes were more likely to be older, have chronic kidney disease, cardiovascular disease, higher troponin levels, and to receive antibiotics compared with adults who did not have diabetes. In Ontario, the crude mortality rate ratio among patients with diabetes was 1.60 [1.24 - 2.07 95% CI] and in the adjusted regression model was 1.19 [0.86 - 1.66 95% CI]. In Denmark, the crude mortality rate ratio among patients with diabetes was 1.27 (0.68 - 2.36 95% CI) and in the adjusted model was 0.87 (0.49 - 1.54 95% CI)]. Meta-analyzing the two rate ratios from each region resulted in a crude mortality rate ratio of 1.55 (95% CI 1.22,1.96) and an adjusted mortality rate ratio of 1.11 (95% CI 0.84, 1.47). ConclusionsPresence of diabetes was not strongly associated with in-hospital COVID mortality independent of illness severity and other comorbidities.

2.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-22276560

RESUMO

BackgroundEnvironmental surveillance of SARS-CoV-2 via wastewater has become an invaluable tool for population-level surveillance of COVID-19. Built environment sampling may provide a more spatially refined approach for surveillance of COVID-19 in congregate living settings and other high risk settings (e.g., schools, daycares). MethodsWe conducted a prospective study in 10 long-term care homes (LTCHs) across three cities in Ontario, Canada between September 2021 and May 2022. Floor surfaces were sampled weekly at multiple locations (range 10 to 24 swabs per building) within each building and analyzed for the presence of SARS-CoV-2 using RT-qPCR. The exposure variable was detection of SARS-CoV-2 on floors. The primary outcome was the presence of a COVID-19 outbreak in the week that floor sampling was performed. ResultsOver the 9-month study period, we collected 3848 swabs at 10 long-term care homes. During the study period, 19 COVID-19 outbreaks occurred with 103 cumulative weeks under outbreak. During outbreak periods, the proportion of floor swabs positive for SARS-CoV-2 was 50% (95% CI: 47-53) with a median quantification cycle of 37.3 (IQR 35.2-38.7). During non-outbreak periods the proportion of floor swabs positive was 18% (95% CI:17-20) with a median quantification cycle of 38.0 (IQR 36.4-39.1). Using the proportion of positive floor swabs for SARS-CoV-2 to predict COVID-19 outbreak status in a given week, the area under the receiver operating curve (AUROC) was 0.85 (95% CI: 0.78-0.92). Using thresholds of [≥]10%, [≥]30%, and [≥]50% of floor swabs positive for SARS-CoV-2 yielded positive predictive values for outbreak of 0.57 (0.49-0.66), 0.73 (0.63-0.81), and 0.73 (0.6-0.83) respectively and negative predictive values of 0.94 (0.87-0.97), 0.85 (0.78-0.9), and 0.75 (0.68-0.81) respectively. Among 8 LTCHs with an outbreak and swabs performed in the antecedent week, 5 had positive floor swabs exceeding 10% at least five days prior to outbreak identification. For 3 of these 5 LTCHs, positivity of floor swabs exceeded 10% more than 10 days before the outbreak being identified. ConclusionsDetection of SARS-CoV-2 on floors is strongly associated with COVID-19 outbreaks in LTCHs. These data suggest a potential role for floor sampling in improving early outbreak identification.

3.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21264590

RESUMO

ObjectivesTo assess the effectiveness of prone positioning to reduce the risk of death or respiratory failure in non-critically ill patients hospitalized with COVID-19 DesignPragmatic randomized clinical trial of prone positioning of patients hospitalized with COVID-19 across 15 hospitals in Canada and the United States from May 2020 until May 2021. SettingsPatients were eligible is they had a laboratory-confirmed or a clinically highly suspected diagnosis of COVID-19, required supplemental oxygen (up to 50% fraction of inspired oxygen [FiO2]), and were able to independently prone with verbal instruction. (NCT04383613). Main Outcome MeasuresThe primary outcome was a composite of in-hospital death, mechanical ventilation, or worsening respiratory failure defined as requiring at least 60% FiO2 for at least 24 hours. Secondary outcomes included the change in the ratio of oxygen saturation to FiO2 (S/F ratio). ResultsA total of 248 patients were included. The trial was stopped early on the basis of futility for the pre-specified primary outcome. The median time from hospital admission until randomization was 1 day, the median age of patients was 56 years (interquartile range [IQR] 45,65), 36% were female, and 90% of patients were receiving oxygen via nasal prongs at the time of randomization. The median time spent prone in the first 72 hours was 6 hours total (IQR 1.5,12.8) for the prone arm compared to 0 hours (0,2) in the control arm. The risk of the primary outcome was similar between the prone group (18 [14.3%] events) and the standard care group (17 [13.9%] events), odds ratio 0.92 (95% CI 0.44 to 1.92). The change in the S/F ratio after 72 hours was similar for patients randomized to prone compared to standard of care. ConclusionAmong hypoxic but not critically patients with COVID-19 in hospital, a multifaceted intervention to increase prone positioning did not improve outcomes. Adherence to prone positioning was poor, despite multiple efforts. Subsequent trials of prone positioning should aim to develop strategies to improve adherence to awake prone positioning. What is already known on this topicProne positioning is considered standard of care for mechanically ventilated patients who have severe acute respiratory distress syndrome. Recent data suggest prone positioning is beneficial for patients with COVID-19 who are requiring high flow oxygen. It is unknown of prone positioning is beneficial for patients not on high flow oxygen. What this study addsProne positioning is generally not well tolerated and innovative approaches are needed to improve adherence. Clinical and physiologic outcomes were not improved with prone positioning among hypoxic but not critically ill patients hospitalized with COVID-19.

4.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21252922

RESUMO

BackgroundCOronaVirus Disease 2019 (COVID-19) can be challenging to diagnose, because symptoms are non-specific, clinical presentations are heterogeneous, and false negative tests can occur. Our objective was to assess the utility of lymphocyte count to differentiate COVID-19 from influenza or community-acquired pneumonia (CAP). MethodsWe conducted a cohort study of adults hospitalized with COVID-19 or another respiratory infection (i.e., influenza, CAP) at seven hospitals in Ontario, Canada.The first available lymphocyte count during the hospitalization was used. Standard test characteristics for lymphocyte count (x109/L) were calculated (i.e., sensitivity, specificity, area under the receiver operating curve [AUC]). All analyses were conducting using R. ResultsThere were 869 hospitalizations for COVID-19, 669 for influenza, and 3009 for CAP. The mean age across the three groups was 67 and patients with pneumonia were older than those with influenza or COVID19, and approximately 46% were woman. The median lymphocyte count was nearly identical for the three groups of patients: 1.0 x109/L (interquartile range [IQR]:0.7,2.0) for COVID-19, 0.9 x109/L (IQR 0.6,1.0) for influenza, and 1.0 x109/L (IQR 0.6,2.0) for CAP. At a lymphocyte threshold of less than 2.0 x109/L, the sensitivity was 87% and the specificity was approximately 10%. As the lymphocyte threshold increased, the sensitivity of diagnosing COVID-19 increased while the specificity decreased. The AUC for lymphocyte count was approximately 50%. InterpretationLymphocyte count has poor diagnostic discrimination to differentiate between COVID-19 and other respiratory illnesses. The lymphopenia we consistently observed across the three illnesses in our study may reflect a non-specific sign of illness severity. However, lymphocyte count above 2.0 x109/L may be useful in ruling out COVID-19 (sensitivity = 87%).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA