Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Aorta (Stamford) ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531385

RESUMO

Seventy years ago, in 1952, Charles A. Hufnagel implanted a caged-ball prosthesis into the descending thoracic aorta, to treat a patient with aortic valve insufficiency. In 1962, 60 years ago, the first aortic homograft was implanted in a subcoronary position by Donald N. Ross and Brian G. Barratt-Boyes. Forty years ago, in 1982, the first anticalcification treatment was introduced in commercially manufactured porcine bioprostheses. All such important or even milestone events should be remembered, since they witness efforts made by those who have significantly influenced the clinical history of aortic and valvular diseases.

2.
Clin Transplant ; 38(4): e15303, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38551461

RESUMO

A 59-year-old woman, with dilated ischemic cardiomyopathy, was urgently admitted to our Intensive Care Unit for cardiogenic shock. ECMO VA was implanted and placed on the national emergency waitlist for transplantation. A potential donation was identified ten days later. The donor was a 58-year-old woman, with no cardiovascular risk factors, had died of a rupture of a cerebral aneurysm with left ventricle dysfunction due to Takotsubo syndrome. Brain injuries such as hemorrhage, trauma and stroke have been extensively documented in literature to cause a surge in stress hormones, such as catecholamines. Such a surge can have a direct effect on the heart, resulting in a transient myocardial dysfunction commonly referred to as "Takotsubo cardiomyopathy" or "broken heart syndrome". Many studies have shown that hearts that are dysfunctional at the start of transplant screening, with normal contractile function at the time of organ retrieval, have similar outcomes to hearts that do not have dysfunction. In our case, the transplanted heart, at the time of sampling, still had moderate dysfunction (EF 40%) which completely disappeared after the transplant.


Assuntos
Coração , Cardiomiopatia de Takotsubo , Feminino , Humanos , Pessoa de Meia-Idade , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/etiologia , Choque Cardiogênico , Doadores de Tecidos
4.
Echocardiography ; 41(1): e15724, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064288

RESUMO

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Humanos , Adulto , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Fluoroscopia , Resultado do Tratamento
7.
Clin Transplant ; 37(8): e15045, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37306944

RESUMO

The advent of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in China at the end of 2019 has developed into a global outbreak, and COVID- 19 is an ongoing major public health issue. During the pandemic, transplant programs had to devise strategies to deal with the possibility of COVID-19-positive donors and recipients. We describe the case of a heart transplant recipient who tested positive with the SARS- CoV2 swab upon admission to our Unit of Cardiac Surgery when a suitable donor became available. Given his clinical status of end-stage heart failure and the absence of imaging and clinical signs suggestive of COVID-19, and his having been vaccinated with three doses, we decided to proceed with the transplant.


Assuntos
COVID-19 , Transplante de Coração , Humanos , SARS-CoV-2 , Doadores de Tecidos , China , Transplantados
8.
Tex Heart Inst J ; 50(3)2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37196250

RESUMO

The year 2023 marks the 100th anniversary of the first successful valvotomy for mitral valve stenosis by Elliott C. Cutler in 1923. Closed-chest mitral valve commissurotomy developed further before being replaced by an open procedure after the advent of the heart-lung machine. Currently, because of the almost complete disappearance of rheumatic disease in the Western World, mitral commissurotomies are infrequently performed in those countries, although the procedure-either closed or open-is still performed in developing countries and select patients. This review retraces the 100-year journey from a historic operation to the current era-a milestone in the treatment of patients with mitral stenosis.


Assuntos
Estenose da Valva Mitral , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Recidiva , Seguimentos
11.
Ann Thorac Surg ; 115(5): 1189-1196, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-34971595

RESUMO

BACKGROUND: Few longitudinal data exist comparing quality of life (QoL) after full sternotomy (fs) aortic valve replacement (AVR) (fsAVR) with ministernotomy AVR (msAVR). METHODS: A total of 1844 consecutive patients undergoing AVR who were prospectively enrolled in a European multicenter registry were dichotomized according to surgical access. Nonparsimonious propensity score matching selected 187 pairs of patients who underwent fsAVR or msAVR with comparable baseline characteristics. Hospital outcome was compared in the 2 groups. QoL was assessed with the Short Form-36, further detailed in its Physical Component Summary (PCS) score and the Mental Component Summary (MCS) score. QoL was investigated at hospital admission, at discharge, and at 1 month, 6 months, and 1 year thereafter. RESULTS: There were 1654 patients undergoing fsAVR and 190 undergoing msAVR in the entire population. The fsAVR group showed a worse preoperative risk profile, a longer intensive care unit length of stay (59.7 hours vs 38.8 hours; p = .002), and a higher rate of life-threatening or disabling bleeding (4.1% vs 0%; P = .011); the msAVR group had a higher rate of early reintervention for failed index intervention (2.1% vs 0.5%; P = .001). QoL investigations showed better PCS and MCS at 1 month after fsAVR, but no temporal trend differences (PCS group-time P = .202; MCS group-time P = .141). Propensity-matched pairs showed comparable baseline characteristics and hospital outcomes (P = not significant for all end points) and comparable improvements of PCS and MCS over time, but no between-group differences over time (PCS group time P = .834; MCS group time P = .737). CONCLUSIONS: Patients with similar baseline profiles report comparable hospital outcomes and comparable improvements of physical and mental health, up to 1 year after surgery, with both fsAVR and msAVR. As for QoL, ministernotomy does not seem to offer any advantage compared with the traditional approach.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Esternotomia , Qualidade de Vida , Resultado do Tratamento
13.
J Card Surg ; 37(11): 3722-3728, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36116053

RESUMO

BACKGROUND: Mitral valve repair using expanded polytetrafluoroethylene sutures to replace mitral chordae tendineae is a well-established procedure. However, the incidence of neo-chordae failure causing recurrent mitral regurgitation is not well defined. METHODS: We have reviewed the reported cases of complications after mitral valve repair related to the use of neo-chordae. This study was mainly carried out through PubMed, Medline, and Google Chrome websites. RESULTS: We have identified a total of 26 patients presenting with rupture of polytetrafluoroethylene neo-chordae, mostly being described as isolated cases. Few other cases of recurrent mitral regurgitation with hemolysis were found, where reoperation was not caused by neo-chordal failure but most likely by technical errors. At pathological investigation the findings were substantially similar in all reported cases. The neo-chordae retained their length and pliability, became covered with host tissue and rupture was mainly related to suture size. Mild calcification was observed not interfering with chordal function; chordal infection did never occur. CONCLUSIONS: The use of artificial neo-chordae provides excellent late results with durable mitral valve repair stability. Chordal rupture may occur late postoperatively leading to reoperation because of recurrent mitral regurgitation. Despite its rarity, this potential complication should not be overlooked during follow-up of patients after mitral valve repair using artificial neo-chordae.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Cordas Tendinosas/patologia , Cordas Tendinosas/cirurgia , Humanos , Valva Mitral/patologia , Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Politetrafluoretileno , Suturas
14.
Echocardiography ; 39(10): 1363-1366, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36138549

RESUMO

INTRODUCTION: Quadricuspid aortic valve (QAV) is an extremely rare developmental abnormality with an incidence of 0.006%. QAV is an incidental finding that in some patients (23%) may determine aortic regurgitation (AR). Altogether 16% of patients indeed require surgery with AR being the most frequent indication. METHODS AND RESULTS: We describe a case report of a 46 year-old female affected by severe aortic regurgitation due to QAV successfully treated with a  modified-tricuspidization technique associated with cusp extension, prolapsing commissure suturing, and sub-commissural annuloplasty. DISCUSSION: QAV repair represents an attractive perspective to overcome the drawbacks of either mechanical or biological prosthesis.


Assuntos
Insuficiência da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Válvula Aórtica Quadricúspide , Feminino , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
17.
Braz J Cardiovasc Surg ; 37(2): 145-152, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35503697

RESUMO

INTRODUCTION: Left ventricular assist devices are an established therapy for end-stage heart failure. Follow-up of these patients showed complications, such as thrombosis. Our objective was to evaluate the contribution of echocardiography - in association with HeartWare HVAD online logfiles reviews and lactate dehydrogenase titration - for diagnosis and treatment of thrombosis. METHODS: Seventeen episodes of thrombosis were diagnosed in 8/20 patients with HVAD. Diagnosis was made by trans-thoracic echocardiographic blood flow velocities, logfiles review of power consumption and pump flows, and titration of lactate dehydrogenase. Data were collected at baseline routine control (Group A), during thrombosis (Group B), after thrombolysis (Group C). RESULTS: Thrombolysis was successful in all cases; one patient died of cerebral haemorrhage. Echocardiographic maximal blood flow velocity near the inflow cannula was 598±42 cm/sec (Group B), 379.41±21 cm/sec (Group C), and 378.24±28 cm/sec (Group A) (P<0.00001). In eight (47%) cases, thrombi were visualized in the left ventricle by three-dimensional modality. Logfiles recordings of blood flows were 9.52±0.9 L/min (Group B), 4.02±0.4 L/min (Group C), and 4.04±0.4 L/min (Group A) (P<00001). Power consumption was 5.01±0.7 W (Group B), 3.45±0.2 W (Group C), and 3.46±0.2 W (Group A) (P<0.00001). Lactate dehydrogenase was 756±54 IU (Group B), 234±22 IU (Group A), and 257±36 IU (Group C) (P<0.00001). CONCLUSIONS: Echocardiography of increased maximal velocity near the inflow cannula is a sign of HVAD obstruction. Logfile reviews provide a clear picture of HVAD obstruction. Combination of echocardiographic data and review of logfiles detects signs of left ventricular assist devices thrombosis leading to a successful treatment.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Lactato Desidrogenases , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia
18.
G Ital Cardiol (Rome) ; 23(5): 340-378, 2022 May.
Artigo em Italiano | MEDLINE | ID: mdl-35578958

RESUMO

Heart failure is a complex clinical syndrome with a severe prognosis, despite therapeutic progress. The management of the advanced stages of the syndrome is particularly complex in patients who are referred to palliative care as well as in those who are candidates for cardiac replacement therapy. For the latter group, a prompt recognition of the transition to the advanced stage as well as an early referral to the centers for cardiac replacement therapy are essential elements to ensure that patients follow the most appropriate diagnostic-therapeutic pathway. The aim of this document is to focus on the main diagnostic and therapeutic aspects related to the advanced stages of heart failure and, in particular, on the management of patients who are candidates for cardiac replacement therapy.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Cardiotônicos/uso terapêutico , Procedimentos Clínicos , Humanos , Cuidados Paliativos
19.
Tex Heart Inst J ; 49(2)2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35390164

RESUMO

Sixty years ago, 2 cardiac operations dramatically influenced the survival of patients with valvular heart disease. The replacement of an aortic valve by Dwight Harken and of a mitral valve by Albert Starr with mechanical caged-ball valves, both in 1960, was a true milestone in the history of cardiac surgery and the beginning of a long journey toward prosthetic valve replacement full of expectations, hopes, and dreams fulfilled. Caged-ball prostheses underwent numerous modifications in design and materials to improve reliability and prevent specific mechanical and thrombogenic complications. Clinical and pathologic experience gained during the past 6 decades has enabled the development of safe, durable, and minimally thrombogenic mechanical prostheses.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Valva Aórtica , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Desenho de Prótese , Reprodutibilidade dos Testes
20.
Rev. bras. cir. cardiovasc ; 37(2): 145-152, Apr. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1376511

RESUMO

ABSTRACT Introduction: Left ventricular assist devices are an established therapy for end-stage heart failure. Follow-up of these patients showed complications, such as thrombosis. Our objective was to evaluate the contribution of echocardiography — in association with HeartWare HVAD online logfiles reviews and lactate dehydrogenase titration — for diagnosis and treatment of thrombosis. Methods: Seventeen episodes of thrombosis were diagnosed in 8/20 patients with HVAD. Diagnosis was made by trans-thoracic echocardiographic blood flow velocities, logfiles review of power consumption and pump flows, and titration of lactate dehydrogenase. Data were collected at baseline routine control (Group A), during thrombosis (Group B), after thrombolysis (Group C). Results: Thrombolysis was successful in all cases; one patient died of cerebral haemorrhage. Echocardiographic maximal blood flow velocity near the inflow cannula was 598±42 cm/sec (Group B), 379.41±21 cm/sec (Group C), and 378.24±28 cm/sec (Group A) (P<0.00001). In eight (47%) cases, thrombi were visualized in the left ventricle by three-dimensional modality. Logfiles recordings of blood flows were 9.52±0.9 L/min (Group B), 4.02±0.4 L/min (Group C), and 4.04±0.4 L/min (Group A) (P<00001). Power consumption was 5.01±0.7 W (Group B), 3.45±0.2 W (Group C), and 3.46±0.2 W (Group A) (P<0.00001). Lactate dehydrogenase was 756±54 IU (Group B), 234±22 IU (Group A), and 257±36 IU (Group C) (P<0.00001). Conclusions: Echocardiography of increased maximal velocity near the inflow cannula is a sign of HVAD obstruction. Logfile reviews provide a clear picture of HVAD obstruction. Combination of echocardiographic data and review of logfiles detects signs of left ventricular assist devices thrombosis leading to a successful treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...