Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
BMJ Case Rep ; 14(4)2021 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-33853812

RESUMO

Nitrofurantoin is a synthetic derivative of imidazolinedione, used to treat uncomplicated urinary tract infections. It acts by inhibiting bacterial DNA, RNA and cell wall protein synthesis. It is used prophylactically as a urinary anti-infective agent against most gram-positive organism and for long-term suppression of infections. Nitrofurantoin-associated pulmonary injuries occur in 1% of patients, presenting with dyspnoea and dry cough, and it can mimic interstitial lung disease. We present a case of an 81-year-old woman with shortness of breath and cough 3 days after initiation of nitrofurantoin. CT of the chest revealed bilateral pleural effusion and extensive pulmonary interstitial prominence, suggesting pulmonary fibrosis. According to the Naranjo Adverse Drug Reaction Probability Scale score of 6, it was determined that nitrofurantoin was the probable cause, and immediate cessation of the medication showed a marked clinical improvement and resolution after 10 days.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Infecções Urinárias , Idoso de 80 Anos ou mais , Anti-Infecciosos Urinários/efeitos adversos , Feminino , Humanos , Pulmão , Nitrofurantoína/efeitos adversos , Infecções Urinárias/tratamento farmacológico
3.
Tex Heart Inst J ; 47(2): 140-143, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32603466

RESUMO

Inferior vena cava (IVC) filter thrombosis can be fatal when it is not detected and treated. Its management can be challenging, because little evidence supports specific treatments. We present the case of a 72-year-old man with a history of deep vein thrombosis in whom IVC filter thrombosis developed 7 years after filter placement. Recanalization with oral anticoagulation had failed. Using intravascular ultrasonography, we performed pharmacomechanical thrombolysis, deploying 2 stents simultaneously through the IVC filter and then 2 more into the iliac veins, with excellent results. One year later, the patient's veins and IVC filter were patent, his symptoms were greatly improved, and only nonobstructive neointimal hyperplasia was seen. This case highlights the usefulness of balloon venoplasty and double-barrel stent placement in restoring blood flow through an occluded IVC, and the value of intravascular ultrasonography during and after such procedures.


Assuntos
Procedimentos Endovasculares/métodos , Ultrassonografia de Intervenção/métodos , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Trombose Venosa/cirurgia , Idoso , Doença Crônica , Angiografia por Tomografia Computadorizada , Seguimentos , Humanos , Masculino , Flebografia/métodos , Grau de Desobstrução Vascular , Veia Cava Inferior/fisiopatologia , Trombose Venosa/diagnóstico , Trombose Venosa/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...