Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
MAbs ; 9(3): 455-465, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28055295

RESUMO

Non-human primate (NHP) studies are often an essential component of antibody development efforts before human trials. Because the efficacy or toxicity of candidate antibodies may depend on their interactions with Fcγ receptors (FcγR) and their resulting ability to induce FcγR-mediated effector functions such as antibody-dependent cell-meditated cytotoxicity and phagocytosis (ADCP), the evaluation of human IgG variants with modulated affinity toward human FcγR is becoming more prevalent in both infectious disease and oncology studies in NHP. Reliable translation of these results necessitates analysis of the cross-reactivity of these human Fc variants with NHP FcγR. We report evaluation of the binding affinities of a panel of human IgG subclasses, Fc amino acid point mutants and Fc glycosylation variants against the common allotypes of human and rhesus macaque FcγR by applying a high-throughput array-based surface plasmon resonance platform. The resulting data indicate that amino acid variation present in rhesus FcγRs can result in disrupted, matched, or even increased affinity of IgG Fc variants compared with human FcγR orthologs. These observations emphasize the importance of evaluating species cross-reactivity and developing an understanding of the potential limitations or suitability of representative in vitro and in vivo models before human clinical studies when either efficacy or toxicity may be associated with FcγR engagement.


Assuntos
Reações Cruzadas/imunologia , Fragmentos Fc das Imunoglobulinas/imunologia , Imunoglobulina G/imunologia , Receptores de IgG/imunologia , Animais , Afinidade de Anticorpos/imunologia , Ensaios de Triagem em Larga Escala , Humanos , Macaca mulatta
2.
Front Immunol ; 7: 589, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28018355

RESUMO

Antibodies raised in Indian rhesus macaques [Macaca mulatta (MM)] in many preclinical vaccine studies are often evaluated in vitro for titer, antigen-recognition breadth, neutralization potency, and/or effector function, and in vivo for potential associations with protection. However, despite reliance on this key animal model in translation of promising candidate vaccines for evaluation in first in man studies, little is known about the properties of MM immunoglobulin G (IgG) subclasses and how they may compare to human IgG subclasses. Here, we evaluate the binding of MM IgG1, IgG2, IgG3, and IgG4 to human Fc gamma receptors (FcγR) and their ability to elicit the effector functions of human FcγR-bearing cells, and unlike in humans, find a notable absence of subclasses with dramatically silent Fc regions. Biophysical, in vitro, and in vivo characterization revealed MM IgG1 exhibited the greatest effector function activity followed by IgG2 and then IgG3/4. These findings in rhesus are in contrast with the canonical understanding that IgG1 and IgG3 dominate effector function in humans, indicating that subclass-switching profiles observed in rhesus studies may not strictly recapitulate those observed in human vaccine studies.

3.
J Immunol ; 197(7): 2936-47, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27559046

RESUMO

Indian rhesus macaques (Macaca mulatta) are routinely used in preclinical studies to evaluate therapeutic Abs and candidate vaccines. The efficacy of these interventions in many cases is known to rely heavily on the ability of Abs to interact with a set of Ab FcγR expressed on innate immune cells. Yet, despite their presumed functional importance, M. mulatta Ab receptors are largely uncharacterized, posing a fundamental limit to ensuring accurate interpretation and translation of results from studies in this model. In this article, we describe the binding characteristics of the most prevalent allotypic variants of M. mulatta FcγR for binding to both human and M. mulatta IgG of varying subclasses. The resulting determination of the affinity, specificity, and glycan sensitivity of these receptors promises to be useful in designing and evaluating studies of candidate vaccines and therapeutic Abs in this key animal model and exposes significant evolutionary divergence between humans and macaques.


Assuntos
Imunoglobulina G/imunologia , Receptores Fc/imunologia , Animais , Sítios de Ligação , Variação Genética/genética , Humanos , Macaca mulatta , Receptores Fc/genética , Receptores Fc/isolamento & purificação
4.
Drug Discov Today ; 19(8): 1040-4, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24880105

RESUMO

Analytical tools are evolving to meet the need for the higher-throughput characterization of therapeutic monoclonal antibodies. An antibody's epitope is arguably its most important property because it underpins its functional activity but, because epitope selection is innate, it remains an empirical process. Here, we focus on the emergence of label-free biosensors with throughput capabilities orders of magnitude higher than the previous state-of-the-art, which can facilitate large assays such as epitope binning so that they can be incorporated alongside functional activity screens, enabling the rapid identification of leads that exhibit unique and functional epitopes. In addition to streamlining the drug development process by saving time and cost, the information from epitope binning assays could provide the basis for intellectual property protection.


Assuntos
Anticorpos Monoclonais/química , Epitopos/química , Ensaios de Triagem em Larga Escala/métodos , Bioensaio/métodos , Técnicas Biossensoriais/métodos , Mapeamento de Epitopos/métodos
5.
J Vis Exp ; (86)2014 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-24796939

RESUMO

The printing of cells for microarray applications possesses significant challenges including the problem of maintaining physiologically relevant cell phenotype after printing, poor organization and distribution of desired cells, and the inability to deliver drugs and/or nutrients to targeted areas in the array. Our 3D microfluidic printing technology is uniquely capable of sealing and printing arrays of cells onto submerged surfaces in an automated and multiplexed manner. The design of the microfluidic cell array (MFCA) 3D fluidics enables the printhead tip to be lowered into a liquid-filled well or dish and compressed against a surface to form a seal. The soft silicone tip of the printhead behaves like a gasket and is able to form a reversible seal by applying pressure or backing away. Other cells printing technologies such as pin or ink-jet printers are unable to print in submerged applications. Submerged surface printing is essential to maintain phenotypes of cells and to monitor these cells on a surface without disturbing the material surface characteristics. By printing onto submerged surfaces, cell microarrays are produced that allow for drug screening and cytotoxicity assessment in a multitude of areas including cancer, diabetes, inflammation, infections, and cardiovascular disease.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Impressão Tridimensional , Análise Serial de Tecidos/métodos , Animais , Camundongos , Células NIH 3T3 , Análise Serial de Tecidos/instrumentação
6.
Analyst ; 139(6): 1303-26, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24479125

RESUMO

Of the diverse analytical tools used in proteomics, protein microarrays possess the greatest potential for providing fundamental information on protein, ligand, analyte, receptor, and antibody affinity-based interactions, binding partners and high-throughput analysis. Microarrays have been used to develop tools for drug screening, disease diagnosis, biochemical pathway mapping, protein-protein interaction analysis, vaccine development, enzyme-substrate profiling, and immuno-profiling. While the promise of the technology is intriguing, it is yet to be realized. Many challenges remain to be addressed to allow these methods to meet technical and research expectations, provide reliable assay answers, and to reliably diversify their capabilities. Critical issues include: (1) inconsistent printed microspot morphologies and uniformities, (2) low signal-to-noise ratios due to factors such as complex surface capture protocols, contamination, and static or no-flow mass transport conditions, (3) inconsistent quantification of captured signal due to spot uniformity issues, (4) non-optimal protocol conditions such as pH, temperature, drying that promote variability in assay kinetics, and lastly (5) poor protein (e.g., antibody) printing, storage, or shelf-life compatibility with common microarray assay fabrication methods, directly related to microarray protocols. Conventional printing approaches, including contact (e.g., quill and solid pin), non-contact (e.g., piezo and inkjet), microfluidics-based, microstamping, lithography, and cell-free protein expression microarrays, have all been used with varying degrees of success with figures of merit often defined arbitrarily without comparisons to standards, or analytical or fiduciary controls. Many microarray performance reports use bench top analyte preparations lacking real-world relevance, akin to "fishing in a barrel", for proof of concept and determinations of figures of merit. This review critiques current protein-based microarray preparation techniques commonly used for analytical and function-based proteomics and their effects on array-based assay performance.


Assuntos
Microtecnologia/instrumentação , Microtecnologia/métodos , Análise Serial de Proteínas/instrumentação , Desenho de Equipamento , Microfluídica/instrumentação , Microfluídica/métodos , Impressão/instrumentação , Impressão/métodos
7.
Anal Chem ; 81(11): 4296-301, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19408947

RESUMO

Surface Plasmon Resonance Microscopy (SPRM) is a promising label-free analytical tool for the real-time study of biomolecule interactions in a microarray format. However, flow cell design and microarray fabrication have hindered throughput and limited applications of SPRM. Here we report the integration of a microfluidic flow cell array (MFCA) with SPRM enabling in situ microarray fabrication and multichannel analysis of biomolecule probe-target interactions. We demonstrate the use of the MFCA for delivery of sample solutions with continuous flow in 24 channels in parallel for rapid microarray creation and binding analysis while using SPRM for real-time monitoring of these processes. Label-free measurement of antibody-antibody interactions demonstrates the capabilities of the integrated MFCA-SPRM system and establishes the first steps of the development of a high-throughput, label-free immunogenicity assay. After in situ probe antibody immobilization, target antibody binding was monitored in real time in 24 channels simultaneously. The limit of detection for this particular antibody pair is 80 ng/mL which is approximately 6 times lower than the industry recommended immunogenicity assay detection limit. The integrated MFCA-SPRM system is a powerful and versatile combination for a range of array-based analyses, including biomarker screening and drug discovery.


Assuntos
Anticorpos/análise , Anticorpos/imunologia , Técnicas Analíticas Microfluídicas/instrumentação , Análise Serial de Proteínas/instrumentação , Ressonância de Plasmônio de Superfície/métodos , Animais , Anticorpos Imobilizados , Biotinilação , Calibragem , Desenho de Equipamento , Cabras , Humanos , Imunoglobulina G/análise , Imunoglobulina G/imunologia , Técnicas Analíticas Microfluídicas/economia , Técnicas Analíticas Microfluídicas/métodos , Análise Serial de Proteínas/economia , Análise Serial de Proteínas/métodos , Sensibilidade e Especificidade , Estreptavidina , Ressonância de Plasmônio de Superfície/instrumentação
8.
Anal Biochem ; 386(1): 98-104, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19135021

RESUMO

We describe the benefits and limitations of two biosensor approaches for screening solubilization conditions for G-protein-coupled receptors (GPCRs). Assays designed for a serial processing instrument (Biacore 2000/3000/T100) and an array platform (Biacore Flexchip) were used to examine how effectively 96 different detergents solubilized the chemokine receptor CCR5 while maintaining its binding activity for a conformationally sensitive Fab (2D7). Using the serial processing instrument, we were able to analyze three samples in each 30-min binding cycle, thereby requiring approximately 24h to screen an entire 96-well plate of conditions. In-line capturing allowed us to normalize the 2D7 binding responses for different receptor capture levels. In contrast, with the array system, we could characterize the effects of all 96 detergents simultaneously, completing the assay in less than 1h. But the current array technology requires that we capture the GPCR preparations off-line, making it more challenging to normalize for receptor capture levels. Also, the array platform is less sensitive than the serial platforms, thereby limiting the size of the analyte to larger molecules (>5000Da). Overall, the two approaches proved to be highly complementary; both assays identified identical detergents that produced active solubilized CCR5 as well as those detergents that either were ineffective solubilizers or inactivated the receptor.


Assuntos
Técnicas Biossensoriais/métodos , Detergentes/normas , Receptores Acoplados a Proteínas G/química , Técnicas Biossensoriais/instrumentação , Fragmentos Fab das Imunoglobulinas/química , Métodos , Receptores CCR5/química , Projetos de Pesquisa , Solubilidade
9.
Anal Biochem ; 382(1): 55-9, 2008 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-18703010

RESUMO

Limitations in depositing ligands using conventional micro-array pin spotting have hindered the application of surface plasmon resonance imaging (SPRi) technology. To address these challenges we introduce a modification to our continuous-flow micro-spotting technology that improves ligand deposition. Using Flexchip protein A/G and neutravidin capturing surfaces, we demonstrate that our new microfluidic spotter requires 1000 times less concentrated antibodies and biotinylated ligands than is required for pin spotting. By varying the deposition flow rate, we show that the design of our tip overlay flow cell is efficient at delivering sample to the substrate surface. Finally, contact time studies show that it is possible to capture antibodies and biotinylated ligands at concentrations of less than 0.1 ug/ml and 100 pM, respectively. These improvements in spotting technology will help to expand the applications of SPRi systems in areas such as antibody screening, carbohydrate arrays, and biomarker detection.


Assuntos
Análise Serial de Proteínas/métodos , Ressonância de Plasmônio de Superfície/métodos , Métodos Analíticos de Preparação de Amostras , Animais , Anticorpos/imunologia , Antígenos/imunologia , Biotina/metabolismo , Metabolismo dos Carboidratos , Bovinos , Ligantes , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...