Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(10): 10I113, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399806

RESUMO

Neutron emission spectroscopy is a diagnostic technique that allows for energy measurements of neutrons born in nuclear reactions. The JET tokamak fusion experiment (Culham, UK) has a special role in this respect as advanced spectrometers for 2.5 MeV and 14 MeV neutrons have been developed here for the first time for measurements of the neutron emission spectrum from D and DT plasmas with unprecedented accuracy. Twin liquid scintillating neutron spectrometers were built and calibrated at the Physikalisch-Technische Bundesanstalt (PTB) (Braunschweig, Germany) and installed on JET in the recent years with tangential-equatorial (KM12) and vertical-radial (KM13) view lines, with the latter only recently operational. This article reports on the performance of KM12 and on the development of the data analysis methods in order to extract physics information upon D ions kinematics in JET auxiliary-heated D plasmas from 2.5 MeV neutron measurements. The comparison of these results with the correspondents from other JET neutron spectrometers is also presented: their agreement allows for JET unique capability of multi-lines of sight neutron spectroscopy and for benchmarking other 14 MeV neutron spectrometers installed on the same lines of sight in preparation for the DT experimental campaign at JET.

2.
Rev Sci Instrum ; 87(11): 11D823, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910604

RESUMO

A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.

3.
Rev Sci Instrum ; 87(11): 11D822, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910679

RESUMO

This work presents measurements done at the Peking University Van de Graaff neutron source of the response of single crystal synthetic diamond (SD) detectors to quasi-monoenergetic neutrons of 14-20 MeV. The results show an energy resolution of 1% for incoming 20 MeV neutrons, which, together with 1% detection efficiency, opens up to new prospects for fast ion physics studies in high performance nuclear fusion devices such as SD neutron spectrometry of deuterium-tritium plasmas heated by neutral beam injection.