RESUMO
The JET neutron camera is a well-established detector system at JET, which has 19 sightlines each equipped with a liquid scintillator. The system measures a 2D profile of the neutron emission from the plasma. A first principle physics method is used to estimate the DD neutron yield that is based on JET neutron camera measurements and is independent of other neutron measurements. This paper details the data reduction techniques, models of the neutron camera, simulations of neutron transport, and detector responses used to this end. The estimate uses a simple parameterized model of the neutron emission profile. The method makes use of the JET neutron camera's upgraded data acquisition system. It also accounts for neutron scattering near the detectors and transmission through the collimator. These components together contribute to 9% of the detected neutron rate above a 0.5 MeVee energy threshold. Despite the simplicity of the neutron emission profile model, the DD neutron yield estimate falls on average within 10% agreement with a corresponding estimate from the JET fission chambers. The method can be improved by considering more advanced neutron emission profiles. It can also be expanded to estimate the DT neutron yield with the same methodology.
RESUMO
The neutron and gamma radiations in large fusion reactors are responsible for damage to charged couple device (CCD) cameras deployed for applied diagnostics. Based on the ASTM guide E722-09, the 'equivalent 1 MeV neutron fluence in silicon' was calculated for a set of CCD cameras at the Joint European Torus. Such evaluations would be useful to good practice in the operation of the video systems.