Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 87(11): 11D401, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910474

RESUMO

Chinese Fusion Engineering Test Reactor (CFETR) is a new superconducting tokamak device being designed in China, which aims at bridging the gap between ITER and DEMO, where DEMO is a tokamak demonstration fusion reactor. Two diagnostic cases, ITER-like case and towards DEMO case, have been considered for CFETR early and later operating phases, respectively. In this paper, some preliminary consideration of ITER-like case will be presented. Based on ITER diagnostic system, three versions of increased complexity and coverage of the ITER-like case diagnostic system have been developed with different goals and functions. Version A aims only machine protection and basic control. Both of version B and version C are mainly for machine protection, basic and advanced control, but version C has an increased level of redundancy necessary for improved measurements capability. The performance of these versions and needed R&D work are outlined.

2.
Rev Sci Instrum ; 87(11): 11E307, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910534

RESUMO

A high-speed tangentially viewing vacuum ultraviolet (VUV) telescope system, using an inverse Schwarzschild-type optic system was developed to study fluctuations in the Large Helical Device (LHD). However, for the original system, the sampling rate was restricted to below 2000 Hz due to the low signal to noise (S/N) ratio in the experiment. In order to improve the S/N ratio, upgrade of the system was made. With this upgraded optical system, the maximum framing rate is improved to 6000 fps with a similar spatial resolution. Rotation of the m = 2 structure caused by the magnetohydrodynamic (MHD) instability is measured by the upgraded system. The spatial structure of the image is consistent with the synthetic image assuming the interchange mode type displacement of the flux surfaces.

3.
Rev Sci Instrum ; 83(10): 10E513, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127020

RESUMO

A high speed tangentially viewing vacuum ultraviolet telescope system has been developed in the Large Helical Device (LHD), with the aim of investigating edge MHD activities. The spatial structure of low frequency (~0.75 kHz) MHD activity with poloidal∕toroidal mode numbers of m∕n = 1∕1 has been measured with this diagnostic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA