Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz Dent J ; 35: e245720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775593

RESUMO

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse Dentário
2.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557212

RESUMO

Abstract This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Resumo Este estudo avaliou o efeito de um novo método para aplicação do sistema adesivo na resistência de união entre pino de fibra e dentina radicular usando dois sistemas adesivos. Os canais de sessenta incisivos bovinos foram preparados e obturados. As raízes foram divididas em seis grupos (n=10) de acordo com o sistema adesivo (Clearfil SE - CSE e Single Bond Universal - SBU) e com a estratégia de aplicação (microbrush - MB, escova rotatória - RB e inserto ultrassônico - US). Os pinos de fibra foram cimentados utilizando cimento resinoso (RelyX ARC). As raízes foram seccionadas perpendicularmente ao seu longo eixo e três fatias foram obtidas. Previamente ao teste de push-out, foi realizada microscopia de varredura confocal a laser para ilustrar a adaptação interfacial do cimento às paredes do canal radicular. Os padrões de falha foram analisados com magnificação de 40x. O teste de Shapiro-Wilk indicou distribuição normal dos dados. Os valores de resistência de união foram comparados usando o teste ANOVA de uma via e post hoc de Tukey. As diferenças entre os sistemas adesivos em cada terço e de acordo com cada protocolo foram analisadas pelo teste T de Student. O nível de significância foi de 5%. CSE aplicado com RB apresentou maiores valores médios de resistência de união do que quando aplicado com MB (técnica convencional) (P<0,05). Aplicação com US apresentou valores intermediários de resistência de união para o CSE (P>0,05). A aplicação do SBU utilizando RB gerou maiores valores médios de resistência de união comparados com MB e US (P<0,05). Falhas adesivas foram predominantes (65,5%). A aplicação do CSE e SBU com a nova escova rotatória melhorou a resistência de união dos pinos de fibra à dentina radicular comparados com a estratégia convencional.

3.
Clin Oral Investig ; 27(12): 7143-7156, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37932637

RESUMO

OBJECTIVES: To evaluate whether the restorative material in direct contact with the dentin influences pulp vitality in primary and permanent teeth with deep carious lesions restored after selective caries removal (SCR). MATERIAL AND METHODS: Systematic searches of databases MEDLINE via PubMed, Scopus and ISI Web of Science were performed for primary and permanent teeth. Inclusion criteria were applied for title and abstract reading of databases search results. After full texts review of included studies, those that did not meet exclusion criteria were excluded from meta-analysis. RESULTS: For meta-analysis, 2 studies were included for permanent teeth and 6 for primary teeth. The failure events reported were meta-analyzed using two statistical methods: standard pairwise meta-analysis (SPMA) and network meta-analysis (NMA). The SPMA identified similar failure occurrence of restorations performed with calcium hydroxide (CH) and other liner materials (RR 0.84, 95% CI 0.41, 1.74; p = 0.64), no significant difference between the use of alternative liners or CH regardless deciduous or permanent teeth (RR 0.79, 95% CI 0.36, 1.71; p = 0.55) and similar risk of failing at different follow-ups for all liner materials tested (RR 0.77, 95% CI 0.35, 1.70; p = 0.52). Probabilistic analysis indicated GIC as liner material with the highest probability of clinical success (SUCRA = 72.76%), and CH ranked as the worst liner material (SUCRA = 21.81%). CONCLUSION: Pulpal vitality was not affected by material used as liner after selective caries removal in deep carious cavities. CLINICAL RELEVANCE: Current clinical evidence supports the weak recommendation to not use calcium hydroxide as liner after SCR.


Assuntos
Hidróxido de Cálcio , Cárie Dentária , Humanos , Hidróxido de Cálcio/uso terapêutico , Cárie Dentária/terapia , Suscetibilidade à Cárie Dentária , Metanálise em Rede , Forramento da Cavidade Dentária/métodos , Dente Decíduo
4.
J Dent ; 126: 104283, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36087873

RESUMO

OBJECTIVES: This review evaluated the effects of the acidic composition of self-etch (SE) adhesives at the long-term bond strengths to dentin and enamel. DATA: The review followed the PRISMA Extension Statement for network meta-analysis. Studies were identified by a systematic search in PubMed, Web of Science, and Scopus databases. STUDY SELECTION: The inclusion criteria were in vitro studies that evaluated bond strength data of samples analyzed at both immediate and long-term (after aging simulation) periods and that were bonded to sound dentin/enamel using SE adhesives, with at least one group of adhesives being based on 10-MDP (10-methacryloyloxy-decyl-dihydrogen-phosphate; control) and the other group being comprised of alternative acidic monomers. Statistical analyses were conducted using two methods: standard pairwise meta-analysis (SPMA) and Bayesian network meta-analysis (NMA). Heterogeneity was assessed by using the Cochran Q test and I2 statistics. RESULTS: From 5220 studies identified, 87 met the eligibility criteria and 83 were meta-analyzed. Seventeen adhesives were based on 10-MDP and 44 systems were based on alternative acids. The resin-dentin/enamel bonds were predominantly reduced after aging (∼84% of cases). From the SPMA findings, the following acidic compositions showed lower bond strength values (effect size: mean difference [MD] with 95% confidence interval [95% CI]) than 10-MDP: 4-META (MD -4.99, 95% CI: -7.21, -2.78; p<0.001); sulfonic acids (MD -9.59, 95% CI -12.19, -6.98; p<0.001); unspecified phosphate esters (MD -8.89, 95% CI -17.50, -0.28; p = 0.04); or mixed acids (MD -11.0, 95% CI -13.62, -8.38; p<0.001). The dental bonds were benefited from the presence of 10-MDP upon longer aging (>6 months). From the NMA probabilistic findings, adhesives based on 10-MDP and phosphonic acids ranked as having the best and the worst bonding potential to dentin, respectively. More than one composition (phosphonic acids and mixed acids) ranked similarly to 10-MDP in enamel. The studies scored as having moderate risk of bias (58.6%), followed by low (39.1%) and high (2.3%) risk of bias. CONCLUSION: 10-MDP is an outstanding acidic monomer that contributes to higher bonds to dentin at the long-term. In enamel, there is no evidence that one acidic composition prevails over the other. CLINICAL SIGNIFICANCE: The acidic composition of SE adhesives affects the resistance of dental bonds after simulated aging, with 10-MDP playing a significant role in the adhesion to dentin but not to the enamel. REGISTRATION NUMBER: This report is registered at the Open Science Framework (osf.io/urtdf).


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos Dentinários/química , Cimentos de Resina/química , Dentina/química , Cimentos Dentários , Metanálise em Rede , Ácidos Fosforosos/análise , Teorema de Bayes , Teste de Materiais , Ácidos Sulfônicos/análise , Fosfatos
5.
J Adhes Dent ; 23(3): 243-252, 2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34060304

RESUMO

PURPOSE: To investigate the influence of the etching strategy of universal adhesives on bond degradation to sound and artificially-induced caries-affected dentin. MATERIALS AND METHODS: The universal adhesives (Scotchbond Universal Adhesive; All-Bond Universal; Prime&Bond Elect) and adhesives used as controls (Adper Single Bond 2 and Clearfil SE Bond) were applied to sound and artificially-induced caries-affected bovine dentin. Microtensile bond strength was evaluated immediately (24 h) and after one year of water storage (1 year). Representative specimens were also prepared to assess nanoleakage. Bond strength data (MPa) were analyzed using three-way ANOVA and post-hoc Tukey's test (α = 0.05), considering each substrate separately. RESULTS: Bonding degradation was observed for all universal adhesives on caries-affected dentin, irrespective of the etching strategy. On sound dentin, bonding degradation was observed when adhesives were used on the etch-and-rinse strategy. CONCLUSION: The universal adhesives were not capable of maintaining bond stability over time on caries-affected dentin. The self-etch strategy seems better able to maintain the durability of adhesive interfaces created on sound dentin.


Assuntos
Colagem Dentária , Cárie Dentária , Animais , Bovinos , Cárie Dentária/terapia , Suscetibilidade à Cárie Dentária , Dentina , Resistência à Tração
6.
Rev. odontol. UNESP (Online) ; 50: e20210004, 2021. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1251983

RESUMO

Abstract Introduction Longevity and clinical success of dental restorations can be influenced by many factors during the restorative procedures. Objective This study aimed to evaluate the influence of different placement techniques on color stability and surface roughness of two resin composites. Material and method The groups of specimens (n=10) were divided according to resin composite (FiltekTM Z250 XT and FiltekTM Z350 XT) and placement technique: Mylar strip, spatula, dry brush, modeling liquid, and surface sealant. Color stability and surface roughness were accessed using a spectrophotometer (CIELab color space) and a rugosimeter (standard cutoff of 0.8 mm), respectively, after water storage. Subsequently, the specimens were immersed in coffee for 48 h and final color was measured. The data were analyzed using ANOVA and the Tukey's post hoc test (α=5%) and the correlation between surface roughness (Ra) and color change (∆Eab) was assessed using the Pearson's correlation coefficient. Result The different placement techniques influenced Ra and ∆Eab on both resin composites. The groups treated with surface sealant showed greater difference in ∆Eab for both resin composites. The FiltekTM Z250 XT resin showed greater color stability compared with the FiltekTM Z350 XT resin regardless of the placement technique used. Ra of each placement technique was similar among the resin composites except for the FiltekTM Z350 XT modeling liquid group, which presented lower Ra values compared with those of FiltekTM Z250 XT. A correlation between Ra and staining was identified (p=0.268). Conclusion Color stability and Ra are influenced by different placement techniques.


Resumo Introdução A longevidade e o sucesso clínico das restaurações dentárias podem ser influenciados por muitos fatores durante os procedimentos restauradores. Objetivo Avaliar a influência da técnica de alisamento na estabilidade de cor e rugosidade superficial de duas resinas compostas. Material e método Os grupos de amostras (n=10) foram divididos conforme a resina composta (FiltekTM Z250 XT e FiltekTM Z350 XT) e as técnicas empregadas: tira de poliéster, espátula, pincel seco, selante de superfície. A cor e a rugosidade da superfície foram avaliadas por espectrofotômetro (espaço de cor CIELab) e rugosímetro (corte padrão de 0,8 mm), respectivamente, após o armazenamento em água. Posteriormente, as amostras foram imersas em café por 48h e a cor final foi aferida. Os dados foram analisados usando teste ANOVA e Tukey post hoc (α = 5%) e a correlação entre rugosidade da superfície (Ra) e variação de cor (∆Eab) através do coeficiente de correlação de Pearson. Resultado As técnicas de alisamento influenciaram a Ra e a ∆Eab em ambas as resinas compostas. Os grupos tratados com selante de superfície apresentaram maior diferença na ∆Eab. A resina FiltekTM Z250 XT apresentou maior estabilidade de cor comparada à FiltekTM Z350 XT, independentemente da técnica utilizada. A Ra das técnicas de alisamento foi semelhante entre os compósitos, exceto para o grupo do líquido modelador da FiltekTM Z350 XT, que apresentou os menores valores. Uma correlação entre Ra e manchamento (p = 0,268) foi identificada. Conclusão A estabilidade da cor e a Ra são influenciadas pelas técnicas de alisamento utilizadas.


Assuntos
Materiais Dentários , Estética Dentária , Resinas Compostas
7.
J Conserv Dent ; 21(2): 136-141, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29674813

RESUMO

AIM: The aim of this study is to evaluate the impact of dentin condition on bond strength of multi-mode adhesive systems (MMAS) to sound and artificially induced caries-affected dentin (CAD). METHODS: Flat dentin surfaces of 112 bovine incisors were assigned to 16 subgroups (n = 7) according to the substrate condition (sound and CAD- pH-cycling for 14 days); adhesive systems (Scotchbond Universal, All-Bond Universal, Prime and Bond Elect, Adper Single Bond Plus and Clearfil SE Bond) and etching strategy (etch-and-rinse and self-etch). All systems were applied according to the manufacturer's instructions, and resin composite restorations were built. After 24 h of water storage, specimens were sectioned (0.8 mm2) and submitted to the microtensile test. STATISTICAL ANALYSIS: Data (MPa) were analyzed using three-way analysis of variance and Tukey's test (α = 0.05). RESULTS: MMAS presented similar bond strength values, regardless etching strategy in each substrate condition. Bond strength values were lower when MMAS were applied to CAD in the etch-and-rinse strategy. CONCLUSION: The etching strategy did not influence the bond strength of MMAS to sound or CAD, considering each substrate separately. However, CAD impact negatively on bond strength of MMAS in etch-and rinse mode.

8.
Gen Dent ; 64(2): e22-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26943097

RESUMO

This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.


Assuntos
Resinas Compostas/química , Selantes de Fossas e Fissuras/uso terapêutico , Café/efeitos adversos , Cor
9.
Clín. int. j. braz. dent ; 9(3): 290-303, jul.-set. 2013. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-765324

RESUMO

A hipoplasia de esmalte insere-se como um dos fatores que podem causar desarmonias estéticas do sorriso, principalmente quando acomete dentes da bateria anterior. Uma abordagem minimamente invasiva, com associação de técnicas conservadoras, apresenta-se como correta indicação para a recuperação estética desses dentes. O presente artigo relata, mediante a exposição de dois casos clínicos, a associação de clareamento dental, microabrasão e macroabrasão, seguida de restaurações com resinas compostas, e a microabrasão foi empregada apenas em um dos casos clínicos. A satisfação das pacientes, juntamente com os resultados clínicos obtidos, comprova a efetividade do tratamento.


Enamel hypoplasia is a common cause of esthetic disharmony, especially when it affects anterior teeth. Minimally invasive approaches are the first option to restore this type of enamel defect. This article presents two case reports of the association of tooth whitening, microabrasion and macroabrasion followed by composite resin restorations. Microabrasion was used only in one of the cases. Patients’ satisfaction, along with clinical results, proved the effectiveness of the association of these treatments.


Assuntos
Humanos , Feminino , Criança , Adulto Jovem , Resinas Compostas , Hipoplasia do Esmalte Dentário , Microabrasão do Esmalte , Estética Dentária , Sorriso , Abrasão Dentária , Clareamento Dental
10.
J Nanosci Nanotechnol ; 12(6): 4749-56, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22905526

RESUMO

Only two of the first row transition metals have elemental oxides that are either ferro- or ferri-magnetic. These are CrO2 and Fe3O4. The electron spin alignment that promotes the ferro(i)magnetism is associated with a double exchange mechanism that requires mixed valence as well as metallic conductivity. This paper describes a novel way to realize these two necessary, but not sufficient conditions for double exchange magnetism. These are mixed valence and a hopping conductivity that promotes at least intra-plane electron spin alignment in a complex oxide perovskite host, A(B,C)O3. A is an ordinary metal, or a rare earth atom, B is a d0 transition metal, and C is a d(n) transition metal in which n > or = 1, as for example in GdSc1-xTi(x)O3. This article combines X-ray absorption spectroscopy, multiplet theory, charge transfer multiplet theory and degeneracy removal by Jahn-Teller effect mechanisms to demonstrate mixed valence for both Sc and Ti above a percolation threshold, x > 0.16, in which hopping transport gives rise to a metal to insulator transition.


Assuntos
Nanoestruturas/química , Nanoestruturas/ultraestrutura , Óxidos/química , Análise Espectral/métodos , Elementos de Transição/química , Transporte de Elétrons , Campos Magnéticos , Teste de Materiais , Tamanho da Partícula
11.
J Nanosci Nanotechnol ; 12(6): 4811-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22905534

RESUMO

Performance and reliability in semiconductor devices are limited by electronically active defects, primarily O-atom and N-atom vacancies. Synchrotron X-ray spectroscopy results, interpreted in the context of two-electron multiplet theories, have been used to analyze conduction band edge, and O-vacancy defect states in nano-crystalline transition metal oxides, e.g., HfO2, and the noncrystalline dielectrics, SiO2, Si3N4 and Si-oxynitride alloys. Two-electron multiplet theory been used to develop a high-spin state equivalent d2 model for O-vacancy allowed transitions and negative ion states as detected by X-ray absorption spectroscopy in the O K pre-edge regime. Comparisons between theory and experiment have used Tanabe-Sugano energy level diagrams for determining the symmetries and relative energies of intra-d-state transitions for an equivalent d2 ground state occupancy. Trap-assisted-tunneling, Poole-Frenkel hopping transport, and the negative bias temperature instability have been explained in terms of injection and/or trapping into O-atom and N-atom vacancy sites, and applied to gate dielectric, and metal-insulator-metal structures.


Assuntos
Háfnio/química , Modelos Químicos , Nanoestruturas/química , Óxidos/química , Oxigênio/química , Compostos de Silício/química , Dióxido de Silício/química , Espectroscopia por Absorção de Raios X/métodos , Simulação por Computador , Cristalização , Transporte de Elétrons , Teste de Materiais , Nanoestruturas/ultraestrutura , Semicondutores
12.
Nanoscale ; 3(4): 1717-23, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21445414

RESUMO

This work presents a novel way to introduce gold nanoparticles (Au NPs) in a multilayer polymer produced by the layer-by-layer (LbL) assembling technique. The technique chosen shows that, depending on the pH used, different morphological structures can be obtained from monolayer or bilayer Au NPs. The MEIS and RBS techniques allowed for the modelling of the interface polymer-NPs, as well as the understanding of the interaction of LbL system, when adjusting the pH in weak polyelectrolytes. The process reveals that the optical properties of multilayer systems could be fine-tuned by controlling the addition of metallic nanoparticles, which could also modify specific polarization responses.


Assuntos
Ouro/química , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Substâncias Macromoleculares/química , Teste de Materiais , Conformação Molecular , Tamanho da Partícula , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA