Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
RSC Adv ; 12(55): 36150-36157, 2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36545087

RESUMO

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 µm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

2.
Sensors (Basel) ; 21(16)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34451010

RESUMO

Aerospace technologies are crucial for modern civilization; space-based infrastructure underpins weather forecasting, communications, terrestrial navigation and logistics, planetary observations, solar monitoring, and other indispensable capabilities. Extraplanetary exploration-including orbital surveys and (more recently) roving, flying, or submersible unmanned vehicles-is also a key scientific and technological frontier, believed by many to be paramount to the long-term survival and prosperity of humanity. All of these aerospace applications require reliable control of the craft and the ability to record high-precision measurements of physical quantities. Magnetometers deliver on both of these aspects and have been vital to the success of numerous missions. In this review paper, we provide an introduction to the relevant instruments and their applications. We consider past and present magnetometers, their proven aerospace applications, and emerging uses. We then look to the future, reviewing recent progress in magnetometer technology. We particularly focus on magnetometers that use optical readout, including atomic magnetometers, magnetometers based on quantum defects in diamond, and optomechanical magnetometers. These optical magnetometers offer a combination of field sensitivity, size, weight, and power consumption that allows them to reach performance regimes that are inaccessible with existing techniques. This promises to enable new applications in areas ranging from unmanned vehicles to navigation and exploration.

3.
ACS Appl Mater Interfaces ; 6(9): 6062-8, 2014 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-24483208

RESUMO

The dielectric and other properties of a series of low-density polyimide block copolymer aerogels have been characterized. Two different anhydride-capped polyimide oligomers were synthesized: one from 2,2-bis(3,4-dicarboxyphenyl)hexafluoropropane dianhydride (6FDA) and 4,4'-oxidianiline (ODA) and the other from biphenyl-3,3',4,4'-tetracarboxylic dianhydride and ODA. The oligomers were combined with 1,3,5-triaminophenoxybenzene to form a block copolymer networked structure that gelled in under 1 h. The polyimide gels were supercritically dried to give aerogels with relative dielectric constants as low as 1.08. Increasing the amount of 6FDA blocks by up to 50% of the total dianhydride decreased the density of the aerogels, presumably by increasing the free volume and also by decreasing the amount of shrinkage seen upon processing, resulting in a concomitant decrease in the dielectric properties. In this study, we have also altered the density independent of fluorine substitution by changing the polymer concentration in the gelation reactions and showed that the change in dielectric due to density is the same with and without fluorine substitution. The aerogels with the lowest dielectric properties and lowest densities still had compressive moduli of 4-8 MPa (40 times higher than silica aerogels at the same density), making them suitable as low dielectric substrates for lightweight antennas for aeronautic and space applications.

4.
ACS Appl Mater Interfaces ; 4(11): 6346-53, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23134844

RESUMO

The dielectric properties and loss tangents of low-density polyimide aerogels have been characterized at various frequencies. Relative dielectric constants as low as 1.16 were measured for polyimide aerogels made from 2,2'-dimethylbenzidine (DMBZ) and biphenyl 3,3',4,4'-tetracarbozylic dianhydride (BPDA) cross-linked with 1,3,5-triaminophenoxybenzene (TAB). This formulation was used as the substrate to fabricate and test prototype microstrip patch antennas and benchmark against state of practice commercial antenna substrates. The polyimide aerogel antennas exhibited broader bandwidth, higher gain, and lower mass than the antennas made using commercial substrates. These are very encouraging results, which support the potential advantages of the polyimide aerogel-based antennas for aerospace applications.


Assuntos
Géis/química , Resinas Sintéticas/química , Telecomunicações/instrumentação , Transdutores , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais
5.
J Microelectromech Syst ; 20(5): 1119-1130, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22267898

RESUMO

The ability to safely monitor neuropotentials is essential in establishing methods to study the brain. Current research focuses on the wireless telemetry aspect of implantable sensors in order to make these devices ubiquitous and safe. Chronic implants necessitate superior reliability and durability of the integrated electronics. The power consumption of implanted electronics must also be limited to within several milliwatts to microwatts to minimize heat trauma in the human body. In order to address these severe requirements, we developed an entirely passive and wireless microsystem for recording neuropotentials. An external interrogator supplies a fundamental microwave carrier to the microsystem. The microsystem comprises varactors that perform nonlinear mixing of neuropotential and fundamental carrier signals. The varactors generate third-order mixing products that are wirelessly backscattered to the external interrogator where the original neuropotential signals are recovered. Performance of the neuro-recording microsystem was demonstrated by wireless recording of emulated and in vivo neuropotentials. The obtained results were wireless recovery of neuropotentials as low as approximately 500 microvolts peak-to-peak (µV(pp)) with a bandwidth of 10 Hz to 3 kHz (for emulated signals) and with 128 epoch signal averaging of repetitive signals (for in vivo signals).

6.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 6245-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17946365

RESUMO

In this paper, a telemetry and contact-less powering system consisting of an implantable bio-MEMS sensor with a miniature printed square spiral chip antenna and an external wearable garment with printed loop antenna is investigated. The implantable chip antenna and the wearable garment pick-up antenna are in close proximity to each other and hence couple inductively through their near-fields and behave as the primary and the secondary circuits of a transformer, respectively. The numerical and experimental results are graphically presented, and include the design parameter values as a function of the geometry and the relative magnetic near-field intensity as a function of the angle, for the implantable chip antenna.


Assuntos
Engenharia Biomédica/métodos , Desenho de Equipamento , Monitorização Ambulatorial/instrumentação , Telemetria/instrumentação , Engenharia Biomédica/instrumentação , Redes de Comunicação de Computadores , Eletrodos , Campos Eletromagnéticos , Análise de Falha de Equipamento , Humanos , Microcomputadores , Miniaturização , Monitorização Ambulatorial/métodos , Ondas de Rádio , Telemetria/métodos , Transdutores
7.
J Opt Soc Am A Opt Image Sci Vis ; 22(2): 346-54, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15717566

RESUMO

Accurate modeling of a high-resolution, liquid-crystal-based, optical phased array (OPA) is demonstrated. The modeling method is extendable to cases where the array element size is close to the wavelength of light. This is accomplished through calculating an equilibrium liquid-crystal (LC) director field that takes into account the fringing electric fields in LC OPAs with small array elements and by calculating the light transmission with a finite-difference time-domain method that has been extended for use in birefringent materials. The diffraction efficiency for a test device is calculated and compared with the simulation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...