Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Ultrasound ; 13: 17, 2015 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-25889304

RESUMO

BACKGROUND: We sought to evaluate the effects of a strong lipophilic statin (pitavastatin) on plaque components and morphology assessed by transesophageal echocardiography (TEE) and transthoracic echocardiography (TTE), as well as plaque inflammation assessed by 18F-fluorodeoxyglucose (FDG) PET/CT in the thoracic aorta and the carotid artery. Furthermore, we compared the effects of pitavastatin with those of mild hydrophilic statin (pravastatin). METHODS: We examined atherosclerotic plaques in the thoracic aorta by TEE and those in the carotid artery by integrated backscatter (IBS)-TTE and PET/CT. We identified the target plaque, where there was macrophage infiltration and inflammation, by strong FDG uptake in the thoracic aorta and carotid arteries and measured maximum standard uptake values (max SUV) by PET/CT. We measured the intima-media thickness (IMT) and the corrected IBS (cIBS) values in the intima-media complex by TEE and TTE at the same site of FDG accumulation by PET/CT. RESULTS: Patients were randomly divided into two treatment groups: a pitavastatin group (PI group: n =10, 68.4 ± 5.1 years) and a pravastatin group (PR group: n =10, 63.9 ± 11.2 years). The same examinations were performed after six months at the same site in each patient. We used calculated target-to-background ratio (TBR) to measure max SUV of plaques and evaluated percent change of TBR. There was no significant difference in low density lipoprotein-cholesterol, TBR, IMT and cIBS values in plaques at baseline between the PI and PR groups. After treatment, there was greater improvement in TBR, cIBS values and IMT in the PI group than the PR group. CONCLUSIONS: The pravastatin treatment was less effective on plaque inflammation than pitavastatin treatment. This trend was the same in the carotid arteries and the thoracic aorta. Pitavastatin not only improved the atherosis as measured by IMT and cIBS values but also attenuated inflammation of plaques as measured by max SUV at the same site. The present study indicated that pitavastatin has stronger effects on the regression and stabilization of plaques in the thoracic aorta and carotid arteries compared with pravastatin.


Assuntos
Aterosclerose/diagnóstico , Aterosclerose/tratamento farmacológico , Artérias Carótidas/efeitos dos fármacos , Pravastatina/administração & dosagem , Quinolinas/administração & dosagem , Artérias Torácicas/efeitos dos fármacos , Idoso , Anti-Inflamatórios/administração & dosagem , Artérias Carótidas/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Artérias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
2.
J Cardiol ; 62(3): 188-94, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23672788

RESUMO

BACKGROUND: The aim of this study was to validate the accuracy of three-dimensional (3D) speckle tracking echocardiography (STE) and two-dimensional (2D)-STE for the assessment of left atrial (LA) volume and function by comparison with 3D-computed tomography (CT) performed on the same day as STE. METHODS: LA phasic volume and emptying function (EF) were measured in 28 patients with paroxysmal atrial fibrillation undergoing catheter ablation (62±11 years old) using both 3D-STE and 2D-STE during sinus rhythm. LA phasic volume and function measured by 3D-STE and 2D-STE were validated using 3D-CT as a gold standard. RESULTS: The intraobserver correlation coefficient and variability in maximum LA volume assessed by 3D-STE were 0.99 and 1.4±6.0%, respectively. The interobserver correlation coefficient and variability in maximum LA volume assessed by 3D-STE were 0.99 and 0.2±4.5%, respectively. There were strong correlations between LA phasic volume measured by 3D-CT and those measured by 3D-STE (r=0.98, p<0.001). There were correlations between LA phasic function measured by 3D-CT and those measured by 3D-STE (r=0.85-0.88, p<0.001). There was a better agreement between 3D-CT and 3D-STE in the assessment of LA phasic volumes and function than between 3D-CT and 2D-STE in apical 2- and 4-chamber view. CONCLUSIONS: 3D-STE allows more accurate measurement of LA volume and function than 2D-STE and has high reproducibility.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Coração/diagnóstico por imagem , Coração/fisiopatologia , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Volume Cardíaco , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...