1.
J Environ Radioact ; 178-179: 84-94, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28797796

RESUMO

A low 134Cs/137Cs ratio anomaly in the north-northwest (NNW) direction from the Fukushima Dai-ichi Nuclear Power Station (FDNPS) is identified by a new analysis of the 134Cs/137Cs ratio dataset which we had obtained in 2011-2015 by a series of car-borne surveys that employed a germanium gamma-ray spectrometer. We found that the 134Cs/137Cs ratio is slightly lower (0.95, decay-corrected to March 11, 2011) in an area with a length of about 15 km and a width of about 3 km in the NNW direction from the FDNPS than in other directions from the station. Furthermore, the area of this lower 134Cs/137Cs ratio anomaly corresponds to a narrow contamination band that runs NNW from the FDNPS and it is nearly parallel with the major and heaviest contamination band in the west-northwest. The plume trace with a low 134Cs/137Cs ratio previously found by other researchers within the 3-km radius of the FDNPS is in a part of the area with the lower 134Cs/137Cs ratio anomaly that we found. Our result suggests that this lower 134Cs/137Cs ratio anomaly is the area which was contaminated before March 13, 2011 (UTC) in association with the hydrogen explosion of Unit 1 on March 12, 2011 at 06:36 (UTC) and it was less influenced by later subsequent plumes.


Assuntos
Poluentes Radioativos do Ar/análise , Radioisótopos de Césio/análise , Acidente Nuclear de Fukushima , Monitoramento de Radiação , Japão , Espectrometria gama
2.
J Environ Radioact ; 139: 281-293, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25189817

RESUMO

We constructed a new car-borne survey system called Radi-Probe with a portable germanium gamma-ray spectrometer onboard a cargo truck, to identify radionuclides and quantify surface contamination from the accident at Fukushima Dai-ichi Nuclear Power Station. The system can quickly survey a large area and obtain ambient dose equivalent rates and gamma-ray energy spectra with good energy resolution. We also developed a new calibration method for the system to deal with an actual nuclear disaster, and quantitative surface deposition densities of radionuclides, such as (134)Cs and (137)Cs, and kerma rates of each radionuclide can be calculated. We carried out car-borne survey over northeastern and eastern Japan (Tohoku and Kanto regions of Honshu) from 25 September through 7 October 2012. We discuss results of the distribution of ambient dose equivalent rate H(∗)(10), (134)Cs and (137)Cs surface deposition densities, spatial variation of (134)Cs/(137)Cs ratio, and the relationship between surface deposition densities of (134)Cs/(137)Cs and H(∗)(10). The ratio of (134)Cs/(137)Cs was nearly constant within our measurement precision, with average 1.06 ± 0.04 in northeastern and eastern Japan (decay-corrected to 11 March, 2011), although small variations from the average were observed.


Assuntos
Poluentes Radioativos do Ar/análise , Automóveis , Acidente Nuclear de Fukushima , Monitoramento de Radiação/métodos , Cinza Radioativa/análise , Radioisótopos/análise , Japão , Centrais Nucleares , Monitoramento de Radiação/instrumentação , Estações do Ano
3.
Igaku Butsuri ; 23(3): 173-83, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14617848

RESUMO

A radiation accident occurred at a medical linear accelerator facility under construction in Japan. The radiation source was a 3- and 6-MV potential drop accelerator designed to produce X-rays for radiation therapy. This accelerator was also capable of producing a 5 to14-MV swept electron beam. During setting up, an operator turned on the accelerator to test the beam not knowing that a man was working on the ceiling above the accelerator. Thus, an X-ray beam was emitted against the ceiling and the man was exposed to 10-MV of X-ray irradiation. However, no obvious physical symptoms were noted. Dose estimation was made from reconstruction of the accident and clinical examinations including chromosome analysis. Mean dose of the whole body ranged from 70 to 180 mSv. Estimated dose from his right foot to hand was between180 to 900 mSv.


Assuntos
Aceleradores de Partículas , Liberação Nociva de Radioativos , Humanos , Japão , Radiometria , Raios X