Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(6): e27395, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38509934

RESUMO

Efficient sanitation system management relies on vigilant sewage surveillance to uphold environmental hygiene. The absence of robust monitoring infrastructure jeopardizes unimpeded conduit flow, leading to floods and contamination. The accumulation of harmful gases in sewer chambers, coupled with tampered lids, compounds sewer network challenges, resulting in structural damage, disruptions, and safety risks from accidents and gas inhalation. Notably, even vehicular transit is vulnerable, facing collisions due to inadequately secured manholes. The core objective of this research was to deconstruct and synthesize a prototype blueprint for a live-feed sewer monitoring framework (LSMF). This involves creating a data gathering nexus (DGN) and empirically assessing diverse wireless sensing implements (WSI) for precision. Simultaneously, a geographic information matrix (GIM) was developed with algorithms to detect sewer surges, blockages, and missing manhole covers. Three scrutinized sensors-the LiDar TF-Luna, laser TOF400 VL53L1X, and ultrasonic JSN-SR04T-were evaluated for their ability to measure water levels in sewer vaults. The results showed that the TF-Luna LiDar sensor performed favorably within the 1.0-5.0 m range, with a standard deviation of 0.44-1.15. The TOF400 laser sensor ranked second, with a more variable standard deviation of up to 104 as obstacle distance increased. In contrast, the JSN-SR04T ultrasonic sensor exhibited lower standard deviation but lacked consistency, maintaining readings of 0.22-0.23 m within the 2.0-5.0 m span. The insights from this study provide valuable guidance for sustainable solutions to sewer surveillance challenges. Moreover, employing a logarithmic function, TF-Luna Benewake exhibited reliability at approximately 84.5%, while TOF400 VL53L1X adopted an exponential equation, boasting reliability approaching approximately 89.6%. With this navigational tool, TF-Luna Benewake maintained accuracy within ±10 cm for distances ranging from 8 to 10 m, showcasing its exceptional performance.

2.
Water Environ Res ; 96(2): e10989, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38303506

RESUMO

The treatment of slaughterhouse wastewater is a complex task demanding careful consideration due to its challenging nature. Therefore, exploring more sustainable treatment methods for this particular type of wastewater is of utmost significance. This research focused on the impact of electrode materials, specifically graphite and titanium, on the efficiency of microbial fuel cells (MFCs) and electro-Fenton systems in treating slaughterhouse wastewater. Both graphite and titanium electrodes displayed increasing current density trends, with titanium outperforming graphite. Titanium showed superior electron transfer and current generation (2.2 to 21.2 mA/m2 ), while graphite ranged from 2.4 to 18.9 mA/m2 . Titanium consistently exhibited higher power density, indicating better efficiency in converting current to power (0.059 to 22.68 mW/m2 ), compared to graphite (0.059 to 12.25 mW/m2 ) over the 48-h period. In removal efficiency within the MFC system alone, titanium exhibited superior performance over graphite in key parameters, including zinc (45.5% vs. 37.19%), total hardness (39.32% vs. 29.4%), and nitrates (66.87% vs. 55.8%). For the electro-Fenton system with a graphite electrode, the removal efficiency ranged from 34.1% to 87.5%, with an average efficiency of approximately 56.2%. This variability underscores fluctuations in the efficacy of the graphite electrode across diverse wastewater treatment scenarios. On the other hand, the electro-Fenton system employing a titanium electrode showed removal efficiency values ranging from 26.53% to 89.99%, with an average efficiency of about 68.4%. The titanium electrode exhibits both a comparatively higher and more consistent removal efficiency across the evaluated scenarios. On the other hand, the integrated system achieved more than 90% removal efficiency from most of the parameters. The study underscores the intricate nature of slaughterhouse wastewater treatment, emphasizing the need for sustainable approaches. PRACTITIONER POINTS: Microbial fuel cell (MFC) and electro-Fenton were investigated for slaughterhouse wastewater treatment. The MFC microbial activity started to decrease after 24 h. The integrated system achieved up to 99.8% removal efficiency (RE) for total coliform bacteria. Up to 99.4% of RE was also achieved for total suspended solids (TSS). The integrated system highly improved RE of the pollutants.


Assuntos
Fontes de Energia Bioelétrica , Grafite , Águas Residuárias , Titânio , Matadouros , Eletrodos , Eletricidade
3.
Biology (Basel) ; 12(4)2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37106823

RESUMO

Natural resources are in short supply, and the ecosystem is being damaged as a result of the overuse of fossil fuels. The creation of novel technology is greatly desired for investigating renewable and sustainable energy sources. Microorganisms have received a lot of interest recently for their potential to transform organic waste into sustainable energy and high-value goods. New exoelectrogens that can transmit electrons to electrodes and remove specific wastewater contaminants are expected to be studied. In this study, we examined three distinct samples (as determined by chemical oxygen demand and pH) that can be used as anolytes to generate power in single-chamber and double-chamber microbial fuel cells using graphite electrodes. Wastewater from poultry farms was studied as an exoelectrogenic anolyte for microbial fuel cell power generation. The study examined 10 different bacterial strains, numbered A1 through A10. Due to their highly anticipated capacity to metabolize organic/inorganic chemicals, the diverse range of microorganisms found in poultry wastewater inspired us to investigate the viability of generating electricity using microbial fuel cells. From the investigated bacterial strains, the highest voltage outputs were produced by strains A1 (Lysinibacillus sphaericus) and A2 (Bacillus cereus), respectively, at 402 mV and 350 mV. Among the 10 different bacterial strains, strain A6 generated the least amount of electricity, measuring 35.03 mV. Furthermore, a maximum power density of 16.16 1.02 mW/m2 was achieved by the microbial fuel cell using strain A1, significantly outperforming the microbial fuel cell using a sterile medium. The strain A2 showed significant current and power densities of 35 1.12 mA/m2 and 12.25 1.05 mW/m2, respectively. Moreover, in the two representative strains, chemical oxygen demand removal and Coulombic efficiency were noted. Samples from the effluent anode chamber were taken in order to gauge the effectiveness of chemical oxygen demand removal. Wastewater had an initial chemical oxygen demand content of 350 mg/L on average. Strains A1 and A2 decomposed 94.28% and 91.71%, respectively, of the organic substrate, according to the chemical oxygen demand removal efficiency values after 72 h. Strains A1 and A2 had electron donor oxidation efficiencies for 72 h of 54.1% and 60.67%, respectively. The Coulombic efficiency increased as the chemical oxygen demand decreased, indicating greater microbial electroactivity. With representative strains A1 and A2, Coulombic efficiencies of 10% and 3.5%, respectively, were obtained in the microbial fuel cell. The findings of this study greatly advance the field as a viable source of power technology for alternative energy in the future, which is important given the depletion of natural resources.

4.
Molecules ; 27(22)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36431830

RESUMO

Groundwater is one of the main sources of water for irrigation used worldwide. However, the application of the resource is threatened by the possibility of high saline levels, especially in low-lying coastal regions. Furthermore, the lack of readily accessible materials for successful treatment procedures makes the purification of such water a constant challenge. Based on the fact that natural zeolite is one of the easily accessible and relatively cheap filter materials, this study examined the potential use of high-salinity groundwater filtered by natural zeolite for irrigation. Zeolite-filled filters at two different depths (0.5 m and 1 m) were studied. The samples were collected from the low-lying areas of Dar es Salaam City, Tanzania. The study observed that when the raw groundwater samples were exposed to the 0.5 m column depth, sodium (Na+) had the lowest removal efficiency at 40.2% and calcium (Ca2+) had the highest removal efficiency at 98.9%. On the other hand, magnesium (Mg2+) had the lowest removal efficiency, at about 61.2%, whereas potassium (K+) had up to about 99.7% removal efficiency from the 1 m column depth treatment system. Additionally, from the salinity hazard potential analysis, most of the samples fell within C4 (based on the electrical conductivity), which is a "very high salinity" class, and based on the quality it means the water cannot be directly applied for irrigation purposes. From the 0.5 m column depth, most of the samples fell within C3 (the "high salinity" class), and from the 1 m column depth most of the samples fell within C1 ("low salinity" class). The findings of this study offer some valuable insight into the prospective use of natural zeolite for the filtration of saline groundwater before its application for irrigation.


Assuntos
Água Subterrânea , Zeolitas , Zeolitas/análise , Monitoramento Ambiental/métodos , Tanzânia , Água Subterrânea/análise , Água/análise
5.
PLoS One ; 17(6): e0259614, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35658025

RESUMO

Direct utilization of treated effluent from natural treatment systems for irrigation can be challenging on sensitive plants due to high levels of salinity. Post-treatment of such an effluent prior to its applicability in irrigation can be of significant importance. In this study, the wastewater from a natural treatment plant was treated using a lab-scale filtration system with zeolite as a filter material. Three different column depths (0.5 m, 0.75 m, and 1 m) were used to investigate the effect of column depth on the treatment efficiency of the media. The suitability of the raw wastewater and the treated effluent from each column for irrigation purposes was investigated. The water quality parameters investigated were; electrical conductivity (EC), total dissolved solids (TDS), sodium (Na+), calcium (Ca2+), and magnesium (Mg2+). From the analysis results, it was observed that the column depth had a significant influence on the removal efficiency of the pollutants. The highest removal efficiency (94.58%) was achieved from the combination of electrical conductivity and 1 m column depth, while the lowest removal efficiency (10.05%) was observed from the combination of calcium and 0.5 m column depth. The raw wastewater fell mostly into a "very high" hazard, which is class four (C4) based on electrical conductivity and class four (S4) based sodium adsorption ratio; making it unsuitable for irrigation purposes. However, when the wastewater was subjected to 1 m column depth, the quality of the treated effluent improved significantly which in turn also improved the suitability of the effluent for irrigation purposes, with percent compliance ranging from 20.19% to 97.54%.


Assuntos
Águas Residuárias , Zeolitas , Cálcio/análise , Lagoas/análise , Sódio/análise , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/análise
6.
Molecules ; 26(22)2021 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-34834122

RESUMO

Textile industry production processes generate one of the most highly polluted wastewaters in the world. Unfortunately, the field is also challenged by the availability of relatively cheap and highly effective technologies for wastewater purification. The application of natural zeolite as a depth filter offers an alternative and potential approach for textile wastewater treatment. The performance of a depth filter treatment system can be deeply affected by the column depth and the characteristics of the wastewater to be treated. Regrettably, the information on the potential of these filter materials for the purification of textile wastewater is still scarce. Therefore, this study investigated the potential applicability of natural zeolite in terms of column depth for the treatment of textile wastewater. From the analysis results, it was observed that the filtration efficiencies were relatively low (6.1 to 13.7%) for some parameters such as total dissolved solids, electrical conductivity, chemical oxygen demand, and sodium chloride when the wastewater samples were subjected to the 0.5 m column depth. Relatively high efficiency of 82 and 93.8% was observed from color and total suspended solids, respectively, when the wastewater samples were subjected to the 0.5 m column depth. Generally, the 0.75 m column depth achieved removal efficiencies ranging from 52.3% to 97.5%, whereas the 1 m column depth achieved removal efficiencies ranging from 86.9% to 99.4%. The highest removal efficiency was achieved with a combination of total suspended solids and 1 m column depth (99.4%). In summary, the treatment approach was observed to be highly effective for the removal of total suspended solids, with a 93.8% removal efficiency when the wastewater was subjected to the 0.5 m column depth, 97.5% for 0.75 m column depth, and 99.4% for 1 m column depth. Moreover, up to 218.233 mg of color per g of the filter material was captured. The results derived in this study provide useful information towards the potential applicability of natural zeolite in the textile wastewater treatment field.

7.
Materials (Basel) ; 13(20)2020 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-33050440

RESUMO

Despite the potential applicability of the combination between aluminium (anode) and graphite or titanium (cathode) for poultry slaughterhouse wastewater treatment, their technical and economic feasibilities have not been comprehensively captured. In this study, aluminium (anode) and graphite and titanium as cathode electrode materials were investigated and compared in terms of their performance on poultry slaughterhouse wastewater treatment. The wastewater samples collected from the Izhevsk Production Corporative (PC) poultry farm in Kazakhstan were treated using a lab-based electrochemical treatment plant and then analyzed after every 20 and 40 min of the treatment processes. Cost analysis for both electrode combinations was also performed. From the analysis results, the aluminium-graphite electrode combination achieved high removal efficiency from turbidity, color, nitrite, phosphates, and chemical oxygen demand, with removal efficiency ranging from 72% to 98% after 20 min, as well as 88% to 100% after 40 min. A similar phenomenon was also observed from the aluminium-titanium electrode combination, with high removal efficiency achieved from turbidity, color, total suspended solids, nitrite, phosphates, and chemical oxygen demand, ranging from 81% to 100% after 20 min as well as from 91% to 100% after 40 min. This means the treatment performances for both aluminium-graphite and aluminium-titanium electrode combinations were highly affected by the contact time. The general performance in terms of removal efficiency indicates that the aluminium-titanium electrode combination outperformed the aluminium-graphite electrode combination. However, the inert character of the graphite electrode led to a positive impact on the total operating cost. Therefore, the aluminium-graphite electrode combination was observed to be cheaper than the aluminium-titanium electrode combination in terms of the operating cost.

8.
Membranes (Basel) ; 10(10)2020 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-32987833

RESUMO

Industrial activities produce a variety of pollutants that may not be easily treated using centralized wastewater treatment systems based on a single treatment unit. The variability of the pollutants brings the importance of industrial-specific integrated wastewater treatment plants such as integrated membrane filtration systems. However, the performance of a membrane filtration process can be highly affected by the presence of high amounts of suspended particles in the raw wastewater. Therefore, proper selection of a pre-treatment unit prior to a membrane filtration wastewater treatment system is a key aspect of its performance. This study investigated the performance of an integrated membrane filtration treatment system connected to an electrochemical process (pre-treatment) on the purification of a poultry slaughterhouse wastewater toward achieving a high-quality effluent. The industrial-scale treatment plant installed at the Izhevsk Production Corporative (PC) poultry farm in Kazakhstan is composed of an electrochemical, ultrafiltration (UF), and reverse osmosis (RO) as the main treatment units. From the analysis results, the electrochemical pre-treatment unit was observed to be highly effective for the removal of some physicochemical parameters such as turbidity, color, total suspended solids, total iron, aluminum, chemical oxygen demand, and biochemical oxygen demand; with removal efficiency ranging from 71 to 85%. The low removal efficiency of the pre-treatment system was also observed from free and total chlorine, nitrites, nitrates, phosphates, and ammonium nitrogen; with removal efficiency ranging from 4 to 45%. While in general, the overall treatment train was observed to be highly efficient for some physicochemical parameters such as turbidity, color, total suspended solids, as well as chemical and biochemical oxygen demand; maintaining almost 100% removal efficiency throughout the study period. Also, the high removal efficiency of the electrochemical pre-treatment processes led to a relatively low rate of cake formation on the membrane filters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...