Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Radiol ; 42(9): 1064-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22526282

RESUMO

BACKGROUND: Catheter rupture during CT angiography has prompted policies prohibiting the use of electronic injectors with peripherally inserted central venous catheters (PICCs) not only for CT but also for MRI. Consequently, many institutions mandate hand injection for MR angiography, limiting precision of infusion rates and durations of delivery. OBJECTIVE: To determine whether electronic injection of gadolinium-based contrast media through a range of small-caliber, single-lumen PICCs would be safe without risk of catheter rupture over the range of clinical protocols and determine whether programmed flow rates and volumes were realized when using PICCs for contrast delivery. MATERIALS AND METHODS: Experiments were performed and recorded using the Medrad Spectris Solaris EP MR Injection System. PICC sizes, contrast media and flow rates were based on common institutional protocols. RESULTS: No catheters were damaged during any experiments. Mean difference between programmed and delivered volume was 0.07 ± 0.10 mL for all experiments. Reduced flow rates and prolonged injection durations were observed when the injector's pressure-limiting algorithm was triggered, only in protocols outside the clinical range. CONCLUSION: PICCs commonly used in children can withstand in vitro power injection of gadolinium-based contrast media at protocols significantly above clinical levels.


Assuntos
Cateteres Venosos Centrais , Meios de Contraste/administração & dosagem , Análise de Falha de Equipamento , Falha de Equipamento , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Segurança de Equipamentos , Injeções Intravenosas , Meglumina/administração & dosagem
2.
Invest Radiol ; 44(1): 31-7, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18923332

RESUMO

PURPOSE: To determine the potential role of dynamic temporally resolved three dimensional (3D) contrast-enhanced magnetic resonance angiography (MRA) for quantitative evaluation of pulmonary perfusion in adult patients with surgically treated Tetralogy of Fallot (ToF). MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. Thirty consecutive patients with surgically repaired ToF and 30 age-matched controls underwent breath-hold 3D time-resolved MRA (TR-MRA) and single-phase high-resolution 3D MRA of the thorax at 1.5 T. Two readers evaluated both datasets for image quality and findings. On TR-MRA datasets, regions-of-interest were placed over main pulmonary artery and lung fields obtaining signal intensity time curves. Using analytic software, time-to-peak (TTP), mean transit time (MTT), maximal signal intensity (MSI), maximum upslope of the curve (MUS), pulmonary blood volume (PBV), and pulmonary blood flow (PBF) were calculated. Pulmonary radionuclide scintigraphy was available for a subgroup of patients with ToF (n = 12). RESULTS: For ToF patients with unilateral pulmonary artery (PA) stenosis, TTP, and MTT were significantly longer, and MSI, MUS, PBV, and PBF were significantly lower in the ipsilateral lung compared with control subjects (P < 0.001 for all). There was no significant difference in TTP, MTT, MSI, MUS, PBV, and PBF between ToF patients without postsurgical stenotic residua and control subjects (P > 0.05 for all), nor between the mentioned perfusion indices for the contralateral lung in ToF patients with unilateral PA stenosis and control subjects (P > 0.05 for all). In ToF, patient with unilateral PA stenosis, analysis of contralateral-to-ipsilateral lung perfusion ratios on radionuclide scintigraphy and TR-MRA revealed significant correlation (r = 0.96). Bland-Altman plot showed a mean difference of 2.2% between the measured ratios (limits of agreement; -7.6%-12.0%). CONCLUSION: Time-resolved 3D contrast-enhanced MRA has potential for noninvasive and quantitative assessment of altered patterns of pulmonary perfusion in adult ToF, and may be a reliable technique for evaluation of postsurgical residua in these patients.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Estenose da Valva Pulmonar/diagnóstico , Tetralogia de Fallot/diagnóstico , Adolescente , Adulto , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tetralogia de Fallot/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS