Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Sports Med ; 51(2): 367-378, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36661257

RESUMO

BACKGROUND: There are limited randomized controlled trials with long-term outcomes comparing autologous chondrocyte implantation (ACI) versus alternative forms of surgical cartilage management within the knee. PURPOSE: To determine at 5 years after surgery whether ACI was superior to alternative forms of cartilage management in patients after a failed previous treatment for chondral or osteochondral defects in the knee. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: In total, 390 participants were randomly assigned to receive either ACI or alternative management. Patients aged 18 to 55 years with one or two symptomatic cartilage defects who had failed 1 previous therapeutic surgical procedure in excess of 6 months prior were included. Dual primary outcome measures were used: (1) patient-completed Lysholm knee score and (2) time from surgery to cessation of treatment benefit. Secondary outcome measures included International Knee Documentation Committee and Cincinnati Knee Rating System scores, as well as number of serious adverse events. Analysis was performed on an intention-to-treat basis. RESULTS: Lysholm scores were improved by 1 year in both groups (15.4 points [95% CI, 11.9 to 18.8] and 15.2 points [95% CI, 11.6 to 18.9]) for ACI and alternative, with this improvement sustained over the duration of the trial. However, no evidence of a difference was found between the groups at 5 years (2.9 points; 95% CI, -1.8 to 7.5; P = .46). Approximately half of the participants (55%; 95% CI, 47% to 64% with ACI) were still experiencing benefit at 5 years, with time to cessation of treatment benefit similar in both groups (hazard ratio, 0.97; 95% CI, 0.72 to 1.32; P > .99). There was a differential effect on Lysholm scores in patients without previous marrow stimulation compared with those with marrow stimulation (P = .03; 6.4 points in favor of ACI; 95% CI, -0.4 to 13.1). More participants experienced a serious adverse event with ACI (P = .02). CONCLUSION: Over 5 years, there was no evidence of a difference in Lysholm scores between ACI and alternative management in patients who had previously failed treatment. Previous marrow stimulation had a detrimental effect on the outcome of ACI. REGISTRATION: International Standard Randomised Controlled Trial Number: 48911177.


Assuntos
Cartilagem Articular , Procedimentos Ortopédicos , Humanos , Cartilagem Articular/cirurgia , Condrócitos/transplante , Articulação do Joelho/cirurgia , Procedimentos Ortopédicos/métodos , Transplante Autólogo/métodos
2.
SICOT J ; 3: 66, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29227785

RESUMO

Patient-specific instruments (PSI) aim to improve the accuracy of total knee replacement (TKR) based on computer-assisted preoperative planning. In this work, the authors describe the advantages and pitfalls of PSI based on their clinical experience. The main conclusion of this work is that PSI has direct impact on the logistical and technical features of TKR with some advantages and pitfalls.

3.
Orthopedics ; 28(5): 451, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15945600

RESUMO

Tight closure, which is a sign of ischemia secondary to tension, can lead to tissue necrosis. This article describes a simple and reliable test to help avoid excessive tension during skin closure.


Assuntos
Procedimentos Cirúrgicos Dermatológicos , Complicações Pós-Operatórias/prevenção & controle , Técnicas de Sutura , Humanos , Isquemia/prevenção & controle , Necrose/prevenção & controle , Pele/irrigação sanguínea , Pele/patologia , Suturas , Cicatrização
4.
Acta Orthop Belg ; 70(5): 429-34, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15587031

RESUMO

The results in a series of 42 patients with 48 impending or complete pathological femur fractures stabilised with the Long Gamma nail (Howmedica-Osteonics, Rutherford, NJ,USA) are presented. Twenty two impending and 26 completed pathological femoral fractures treated between 1995 and 1999 were retrospectively analysed. The mean age of the patients was 65.7 yrs (range: 40 to 88). All patients were treated with an 11-mm diameter Long Gamma Nail, inserted through a 5-cm incision proximal to the greater trochanter using the antegrade reaming technique. The mean surgical time was 98 minutes (range: 65 to 225). Reliable stability was achieved in all cases and pain relief was excellent. Complications included 2 superficial and 1 deep wound infections, 4 chest infections, 2 urinary tract infections, and 2 deaths in the recovery. Implant failure occurred in one patient and needed revision to a long stemmed total hip prosthesis. The Long Gamma nail offers the advantage of a technically less demanding percutaneous insertion through the tip of the greater trochanter, secure proximal femoral fixation and the ability to allow immediate or early weight-bearing ambulation. Because of these advantages, we recommend the use of the Long Gamma nail for stabilisation of pathologic and impending pathologic fractures of the femur.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Fraturas Espontâneas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas do Colo Femoral/diagnóstico por imagem , Seguimentos , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura/fisiologia , Fraturas Espontâneas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Radiografia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento
5.
Acta Orthop Belg ; 70(5): 478-81, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15587038

RESUMO

The authors describe a new technique of fixation of comminuted displaced distal radial fractures in young adults. A 40-year-old man fell from a ladder and injured his wrist. He sustained a comminuted fracture of the distal radius. The fracture was opened through a volar incision and the three rotated, unreduced fragments were reduced and fixed with three Acutrak (Acumed Inc., Beaverton, OR, USA) screws. A removable splint was applied to the wrist for one week, following which the wrist was mobilised. Six months later at a routine follow-up the patient had full functional use of the wrist. The purpose of this technical note is to discuss the fracture, the fixation technique, and the management of this subtype of distal radial fractures in young adults.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas Cominutivas/cirurgia , Fraturas do Rádio/cirurgia , Traumatismos do Punho/cirurgia , Acidentes por Quedas , Adulto , Seguimentos , Fixação Interna de Fraturas/métodos , Consolidação da Fratura/fisiologia , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Radiografia , Fraturas do Rádio/diagnóstico por imagem , Amplitude de Movimento Articular/fisiologia , Medição de Risco , Resultado do Tratamento , Traumatismos do Punho/diagnóstico por imagem
6.
Acta Orthop Belg ; 70(4): 365-7, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15481423

RESUMO

The authors describe two cases of phalangeal intraosseous epidermoid cyst. Two theories try to explain their origin. One theory sees traumatic implantation of epidermal cells as causative. A second theory is based on faulty embryogenesis.


Assuntos
Cisto Epidérmico/cirurgia , Articulações dos Dedos , Artropatias/cirurgia , Adulto , Desbridamento/métodos , Cisto Epidérmico/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Artropatias/diagnóstico por imagem , Masculino , Procedimentos Ortopédicos/métodos , Radiografia , Índice de Gravidade de Doença , Resultado do Tratamento
7.
Arch Orthop Trauma Surg ; 124(6): 429, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15095098

RESUMO

We describe a simple and reliable test which can be used while performing hip arthroplasty as an indicator of the size and volume of the femoral canal to roughly estimate the volume of cement required to fill the femoral canal for cementing the femoral prosthesis.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Cimentação , Humanos , Canal Inguinal , Ortopedia/métodos , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Sensibilidade e Especificidade
8.
Acta Orthop Belg ; 69(6): 507-9, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14748105

RESUMO

Unstable fractures of the distal radius can be stabilised with Kirschner wires. The K wires need to be removed after five to six weeks. The authors surveyed 100 consecutive patients with distal radial fractures treated with percutaneous Kirschner wires that were left buried under the skin. Group A had 50 patients who had such wires removed under local anaesthetic in the orthopaedic outpatient department. Group B comprised of patients who had the wires removed in the operating theatres under a short general anaesthetic. A questionnaire was designed to assess the satisfaction of these 100 patients. The survey showed that the patient satisfaction for this minor procedure carried out in the outpatient clinic was poor. Patient information and senior surgical input could increase the satisfaction.


Assuntos
Fios Ortopédicos , Remoção de Dispositivo/efeitos adversos , Satisfação do Paciente , Fraturas do Rádio/cirurgia , Inquéritos e Questionários , Idoso , Anestesia Geral , Anestesia Local , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais
9.
J Bone Joint Surg Am ; 84(10): 1782-7, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12377908

RESUMO

BACKGROUND: Anterior cruciate ligament reconstruction with use of bone-patellar tendon-bone graft is commonly performed to treat functional instability of the knee after injury of the anterior cruciate ligament. Patellar fracture is an underreported complication of this procedure, yet it may be a career-ending injury for a professional athlete. The purpose of this study was to design a new technique to procure the patellar bone plug when reconstructing the cruciate ligament with use of patellar tendon. METHODS: Fifty-eight knees were harvested from eighteen to twenty-four-month-old pigs. Bone plugs of four geometrical shapes were cored out of the patellae from forty knees (four plug shapes for each of ten knees). Ten knees had no graft removed. Fifty knees were tested for the effects of a single impact. Eight knees (two plug shapes for each of four knees) were tested for the effects of repeated impacts. Data were analyzed statistically with use of an ordinal logistic model. The probability of impact failure of the patella at different energy levels was calculated. RESULTS: Impact energy has been shown to have a significant effect on the outcome (p < 0.001). When controlling for energy level, there was a significant difference between the sharp and round corners (p < 0.01). The ordinal logistic model was found to be very good for predicting the outcome of impact testing. The impact energy required to create a 1% probability of complete fracture was 7 J for a patella with a sharp-cornered plug defect, 17 J for a patella with a trapezoidal plug, 22 J for a patella with a sharp-cornered defect with a drill-hole at the corner, 40 J for a patella with a round-cornered defect, and about 49 J for a normal patella. Repeat impact testing substantially damaged the patellae with sharp-cornered defects, as they failed earlier at a lower energy and after a lower number of impacts than did the patellae with round-cornered defects. CONCLUSIONS: We propose the use of the round-cornered patellar bone plug when bone-patellar tendon-bone graft is harvested for anterior cruciate ligament reconstruction, to further reduce the small likelihood of a patellar fracture occurring intraoperatively or in the early postoperative rehabilitation phase.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Transplante Ósseo/métodos , Tendões , Coleta de Tecidos e Órgãos/métodos , Animais , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Modelos Logísticos , Modelos Animais , Probabilidade , Coelhos , Procedimentos de Cirurgia Plástica/métodos , Sensibilidade e Especificidade , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...