Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Health Serv Res ; 23(1): 1169, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891622

RESUMO

BACKGROUND AND PURPOSE: Hemovigilance is a set of monitoring methods that covers the blood transfusion chain, from collecting blood and blood products to monitoring the blood recipients. To this end, any error in this process can have serious and irreparable consequences for patients. The present study aimed to investigate the quality of hemovigilance process in Iran, using the first two steps of Six Sigma model. METHODS: This was a quantitative cross-sectional study that was conducted over 6 months (from August 20, 2021, to February 20, 2022) at Afzalipour Hospital in Iran, using the first two steps of Six Sigma model. The study population comprised of all inpatients who needed blood or blood product transfusion in various departments of Afzalipour Hospital, among whom 477 patients were selected via stratified sampling in three shifts (morning, evening, and night). The datasheet was used to record errors in the three shifts. This research was conducted, using the DMAIC cycle's "define" and "measure" steps. RESULTS: In the define step, the hemovigilance process at Afzalipour Hospital was divided into two categories of normal process and emergency process. Each of these processes consists of several sub-processes, including "phlebotomy," "requesting blood and blood products from the department," "preparation of application by the blood bank," " sending a request from the blood bank to the blood transfusion center," "transfusing blood and blood products," and "returning the blood and blood products to the blood bank and waste disposal." In the measure step, the quality of hemovigilance process was evaluated based on sub-processes and labels at morning, evening and night shifts. The sub-process of sending a request from the blood bank to the blood transfusion center had the highest error rate with a sigma level of 1.5. Also, the evening and night shifts had a sigma level of 1.875, and the clinical and registration labels had a sigma level of 1.875. The overall sigma level of hemovigilance process was calculated to be 2. CONCLUSION: The results of this study showed that the quality of hemovigilance process at Afzalipour Hospital was poor. By employing the first two steps of Six Sigma method, we identified the existing errors in the hemovigilance process of Afzalipour hospital in order to assist hospital managers to take the necessary measures to improve this process.


Assuntos
Segurança do Sangue , Gestão da Qualidade Total , Humanos , Estudos Transversais , Transfusão de Sangue , Bancos de Sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...