Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Xenobiotica ; 53(2): 93-105, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36794569

RESUMO

The metabolism and pharmacokinetics of fasiglifam (TAK-875, 2-[(3S)-6-[[3-[2,6-dimethyl-4-(3-methylsulfonylpropoxy)phenyl]phenyl]methoxy]-2,3-dihydro-1-benzofuran-3-yl]acetic acid), a selective free fatty acid receptor 1 (FFAR1)/GPR40 agonist, were studied following intravenous (5 mg/kg) and oral administration (10 and 50 mg/kg) to male and female Sprague Dawley rats.Following intravenous dosing at 5 mg/kg, peak observed plasma concentrations of 8.8/9.2 µg/ml were seen in male and female rats respectively.Following oral dosing, peak plasma concentrations at 1 h of ca. 12.4/12.9 µg/ml for 10 mg/kg and 76.2/83.7 µg/ml for 50 mg/kg doses were obtained for male and female rats respectively. Drug concentrations then declined in the plasma of both sexes with t1/2's of 12.4 (male) and 11.2 h (female). Oral bioavailability was estimated to be 85-120% in males and females at both dose levels.Urinary excretion was low, but in a significant sex-related difference, female rats eliminated ca. 10-fold more drug-related material by this route.Fasiglifam was the principal drug-related compound in plasma, with 15 metabolites, including the acyl glucuronide, also detected. In addition to previously identified metabolites, a novel biotransformation, that produced a side-chain shortened metabolite via elimination of CH2 from the acetyl side chain was noted with implications for drug toxicity.


Assuntos
Receptores Acoplados a Proteínas G , Sulfonas , Ratos , Masculino , Feminino , Animais , Ratos Sprague-Dawley , Administração Intravenosa , Receptores Acoplados a Proteínas G/agonistas , Administração Oral , Injeções Intravenosas
2.
Talanta ; 254: 124089, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36459869

RESUMO

The use of vacuum jacketed LC columns (VJC) to minimize on- and post-column band broadening to maximize chromatographic performance has been evaluated as a potential route to improved high throughput (HT) analysis. Here the use of the "VJC" approach has been applied to the HT bioanalysis of the antidiabetic GPR40 agonist drug fasiglifam in rat plasma samples obtained following a 5 mg/kg IV dose. The data obtained from a 1 minute VJC/MS-based analysis showed significant improvements compared to that from a conventional 2 minute UHPLC method for the drug. Notably, using VJC/MS with the rapid 1 min analysis provided a ca. 50% reduction in peak width coupled with a 2-5 fold higher peak response whilst doubling analytical throughput when compared to a conventional UHPLC/MS method. In addition, the increased resolution provided by the VJC system also improved the separation of fasiglifam from common matrix interferences such as co-extracted phospholipids thereby reducing the potential for matrix effects. The concatenation of these improvements suggests that the VJC approach may indeed provide a pathway to more sensitive, robust and high throughput drug bioanalysis, with particular advantages for drug discovery applications.


Assuntos
Espectrometria de Massas em Tandem , Ratos , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Vácuo , Cromatografia Líquida/métodos
3.
Metabolites ; 11(6)2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34208076

RESUMO

The effects of intravenous gefitinib (10 mg/kg), an anilinoquinazoline thymidylate kinase inhibitor (TKI), selective for the epidermal growth factor receptor (EGFR), on the urinary metabotypes of mice were studied. We hypothesized that, in response to the administration of gefitinib, there might be significant changes in the excretion of many endogenous metabolites in the urine, which could be correlated with the plasma pharmacokinetics (PK) of the drug. In order to investigate this conjecture, urine from male C57 BL6 mice was collected before IV dosing (10 mg/kg) and at 0-3, 3-8, and 8-24 h post-dose. The samples were profiled by UPLC/IM/MS and compared with the profiles obtained from undosed control mice with the data analyzed using multivariate statistical analysis (MVA). This process identified changes in endogenous metabolites over time and these were compared with drug and drug metabolite PK and excretion. While the MVA of these UPLC/IM/MS data did indeed reveal time-related changes for endogenous metabolites that appeared to be linked to drug administration, this analysis did not highlight the presence of either the drug or its metabolites in urine. Endogenous metabolites affected by gefitinib administration were identified by comparison of mass spectral, retention time and ion mobility-derived collision cross section data (compared to authentic standards wherever possible). The changes in endogenous metabolites resulting from gefitinib administration showed both increases (e.g., tryptophan, taurocholic acid, and the dipeptide lysyl-arginine) and decreases (e.g., deoxyguanosine, 8-hydroxydeoxyguanosine, and asparaginyl-histidine) relative to the control animals. By 8-24 h, the post-dose concentrations of most metabolites had returned to near control values. From these studies, we conclude that changes in the amounts of endogenous metabolites excreted in the urine mirrored, to some extent, the plasma pharmacokinetics of the drug. This phenomenon is similar to pharmacodynamics, where the pharmacological effects are related to the drug concentrations, and by analogy, we have termed this effect "pharmacometabodynamics".

4.
Sci Rep ; 11(1): 8298, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33859329

RESUMO

Two 3-oxo-Δ4 fetal bile acids, 3-oxachola-4,6-dien-24-oic acid (1) and 7α-hydroxy-3-oxochol-4-en-24-oic acid (2), occur normally in the human fetus but remain elevated in neonates and children with severe cholestatic liver disease due to an autosomal recessive inborn error of metabolism affecting Δ4-3-oxo-steroid 5ß-reductase (AKR1D1). Relatively little is known about 1 and 2 in adult patients with liver disease. The chemical synthesis of 1 and 2 is therefore described and their quantitation in plasma by ultrarapid chromatography-triple quadrupole mass spectrometry. Plasma concentrations of 1 and 2 were investigated in 25 adult patients with varying degrees of liver cirrhosis with and without hepatocellular carcinoma (HCC). Highly statistically significant correlations (P < 0.0001) were found between severity of liver cirrhosis, determined by the Child-Pugh and MELD scores, with plasma 1 and 2 concentrations, both alone and combined. The presence of HCC did not influence these correlations. Plasma cholic, chenodeoxycholic, deoxycholic, lithocholic or ursodeoxycholic acids, free and as their glycine or taurine conjugates, did not correlate with Child-Pugh or MELD score when corrected for multiple comparisons. These findings demonstrate that plasma levels of fetal bile acids 3-oxachola-4,6-dien-24-oic acid and 7α-hydroxy-3-oxochol-4-en-24-oic acid and likely deteriorating AKR1D1 activity indicate the severity of liver cirrhosis measured by the Child-Pugh and MELD scores.


Assuntos
Ácidos e Sais Biliares/sangue , Cirrose Hepática/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Carcinoma Hepatocelular/complicações , Feminino , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Oxirredutases/metabolismo , Índice de Gravidade de Doença
5.
Xenobiotica ; 51(4): 434-446, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33280466

RESUMO

The metabolism and pharmacokinetics of gefitinib (Iressa®, N-(3-chloro-4-fluorophenyl)-7-methoxy-6-(3-morpholino-propoxy)quinazolin-4-amine), a selective thymidylate kinase inhibitor for the epidermal growth factor receptor (EGFR), was studied after IV and PO administration to male C57BL6 mice at 10 and 50 mg/kg respectively.The pharmacokinetics and metabolism of gefitinib were investigated using a range of rapid UHPLC-MS and UHPLC-IM-HRMS methods, using both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC), to rapidly determine the drugs pharmacokinetics and metabolic fate.Rapid oral absorption resulted in peak plasma concentrations at 1 h of ca. 7 µg/mL, that declined with a half-life of 3.8 h (2.6 h for the IV route), and providing an estimated oral bioavailability of 53%. Gefitinib itself was the major circulating drug-related compound in plasma extracts, with a total of 11 metabolites identified.The urinary profiles determined using both HILIC and RP-UPLC-IM-MS detected gefitinib and 10 metabolites or 15 metabolites respectively including the detection of a number of novel glucuronide conjugates.Despite rapid, sub 5 min, LC profiling methods being employed metabolite coverage was shown to be high and compared well with that of previous studies.


Assuntos
Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Gefitinibe , Masculino , Camundongos , Camundongos Endogâmicos C57BL
6.
Artigo em Inglês | MEDLINE | ID: mdl-32629236

RESUMO

INTRODUCTION: Obesity is associated with adipose tissue inflammation which in turn drives insulin resistance and the development of type 2 diabetes. Oxylipins are a collection of lipid metabolites, subdivided in different classes, which are involved in inflammatory cascades. They play important roles in regulating adipose tissue homeostasis and inflammation and are therefore putative biomarkers for obesity-associated adipose tissue inflammation and the subsequent risk of type 2 diabetes onset. The objective for this study is to design an assay for a specific oxylipin class and evaluate these as potential prognostic biomarker for obesity-associated adipose tissue inflammation and type 2 diabetes. METHODS: An optimized workflow was developed to extract oxylipins from plasma using solid-phase extraction followed by analysis using ultra-high performance liquid chromatography coupled to a triple quadrupole mass spectrometer in multiple reaction monitoring mode. This workflow was applied to clinical plasma samples obtained from obese-type 2 diabetes patients and from lean and obese control subjects. RESULTS: The assay was analytically validated and enabled reproducible analyses of oxylipins extracted from plasma with acceptable sensitivities. Analysis of clinical samples revealed discriminative values for four oxylipins between the type 2 diabetes patients and the lean and obese control subjects, viz. PGF2α, PGE2, 15-keto-PGE2 and 13,14-dihydro-15-keto-PGE2. The combination of PGF2α and 15-keto-PGE2 had the most predictive value to discriminate type 2 diabetic patients from lean and obese controls. CONCLUSIONS: This proof-of-principle study demonstrates the potential value of oxylipins as biomarkers to discriminate obese individuals from obese-type 2 diabetes patients.


Assuntos
Tecido Adiposo/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Diabetes Mellitus Tipo 2/sangue , Espectrometria de Massas/métodos , Obesidade/metabolismo , Oxilipinas/sangue , Biomarcadores/sangue , Ciclo-Oxigenase 2/metabolismo , Humanos , Oxilipinas/química , Oxilipinas/isolamento & purificação , Extração em Fase Sólida , Fluxo de Trabalho
7.
J Bone Miner Res ; 32(7): 1589-1596, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28304097

RESUMO

CYP24A1 mutations are now accepted as a cause of idiopathic infantile hypercalcemia (IIH). A rapid liquid-chromatography tandem mass spectrometry (LC-MS/MS)-based blood test enabling measurement of the 25-OH-D3 :24,25-(OH)2 D3 ratio (R) can identify IIH patients on the basis of reduced C24-hydroxylation of 25-OH-D3 by CYP24A1 in vivo. Although values of this ratio are significantly elevated in IIH, somewhat surprisingly, serum 24,25-(OH)2 D3 remains detectable. The current study explores possible explanations for this including: residual CYP24A1 enzyme activity in individuals with certain CYP24A1 genotypes, expression of alternative C24-hydroxylases, and the possibility of isobaric contamination of the 24,25-(OH)2 D3 peak on LC-MS/MS. We employed an extended 20-min run time on LC-MS/MS to study serum vitamin D metabolites in patients with IIH due to mutations of CYP24A1 or SLC34A1; in unaffected heterozygotes and dialysis patients; in patients with vitamin D deficiency; as well as in normal subjects exhibiting a broad range of 25-OH-D levels. We identified 25,26-(OH)2 D3 as a contaminant of the 24,25-(OH)2 D3 peak. In normals, the concentration of 24,25-(OH)2 D3 greatly exceeds 25,26-(OH)2 D3 ; however, 25,26-(OH)2 D3 becomes more significant in IIH with CYP24A1 mutations and in dialysis patients, where 24,25-(OH)2 D3 levels are low when CYP24A1 function is compromised. Mean R in 30 IIH-CYP24A1 patients was 700 (range, 166 to 2168; cutoff = 140) as compared with 31 in 163 controls. Furthermore, patients possessing CYP24A1 L409S alleles exhibited higher 24,25-(OH)2 D3 levels and lower R (mean R = 268; n = 8) than patients with other mutations. We conclude that a chromatographic approach which resolves 24,25-(OH)2 D3 from 25,26-(OH)2 D3 produces a more accurate R that can be used to differentiate pathological states where CYP24A1 activity is altered. The origin of the residual serum 24,25-(OH)2 D3 in IIH patients appears to be multifactorial. © 2017 American Society for Bone and Mineral Research.


Assuntos
24,25-Di-Hidroxivitamina D 3/sangue , Hipercalcemia/sangue , Espectrometria de Massas/métodos , Idoso , Cromatografia Líquida , Feminino , Genótipo , Humanos , Hipercalcemia/genética , Pessoa de Meia-Idade , Mutação , Vitamina D3 24-Hidroxilase/genética
8.
Proteomics ; 16(15-16): 2206-20, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27214876

RESUMO

The application of unit resolution tandem quadrupole and high-resolution orthogonal acceleration ToF mass spectrometers for the quantitation and translational analysis of proteolytic peptides is described. The MS platforms were contrasted in terms of sensitivity and linear response. Moreover, the selectivity of the platforms was investigated and the effect on quantitative precision studied. Chromatographic LC conditions, including gradient length and configuration, were investigated with respect to speed/throughput, while minimizing isobaric interferences, thereby providing information with regard to practical sample cohort size limitations of LC-MS for large cohort experiments. In addition to these fundamental analytical performance metrics, precision and linear dynamic ranges were also studied. An LC-MS configuration that encompasses the best combination of throughput and analytical accuracy for translational studies was chosen, despite the MS platforms giving similar quantitative performance, and instances were identified where alternative combinations were found to be beneficial. This configuration was utilized to demonstrate that proteolytically digested nondepleted samples from heart failure patients could be classified with good discriminative power using a subset of proteins previously suggested as candidate biomarkers for cardiovascular diseases.


Assuntos
Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Peptídeos/análise , Peptídeos/química , Reprodutibilidade dos Testes , Pesquisa Translacional Biomédica
9.
Analyst ; 133(5): 655-9, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18427688

RESUMO

An in situ analytical approach to the measurement of supported liquid membrane permeability is reported. The method consists of a spectrophotometric method to measure transport through a membrane-supported lipid solution, using a rotating-diffusion cell configuration to overcome limits arising from transport through the aqueous solution boundary layer in stationary systems. Rotation frequencies are almost two orders of magnitude higher than those employed previously for rotating-diffusion studies of membrane transport. The method is illustrated with the transport of warfarin [1-(4'-hydroxy-3'-coumarinyl)-1-phenyl-3-butanone]. The use of the rotating-diffusion approach permits accurate calculation of the aqueous phase boundary layer thickness, which has hitherto been treated as an adjustable parameter in studies of membrane permeability. Further, it is shown that the analyte diffusion coefficient can be determined readily using liquid-liquid electrochemistry.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Membranas Artificiais , Varfarina/química , Difusão , Eletroquímica/métodos , Permeabilidade , Rotação , Espectrofotometria/instrumentação , Espectrofotometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA