Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
2.
J Biomol Screen ; 18(4): 430-40, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23204072

RESUMO

An integrated assay system involving dual/triple-probe microdialysis techniques in rats was developed earlier for testing interactions with P-glycoprotein (P-gp) at the blood-brain barrier using quinidine/PSC-833 as a P-gp substrate/inhibitor combination. The aim of the present study was to expand our assay system to mice using microdialysis with simultaneous sampling of blood and brain and to compare the result with a primary mouse brain endothelial cell monolayer (pMBMEC) assay. Brain penetration of quinidine was dose dependent in both anesthetized and awake mice after intraperitoneal drug administration. PSC-833 pretreatment caused a 2.5- to 3.4-fold increase in quinidine levels of brain dialysate samples in anesthetized or awake animals, after single or repeated administration of PSC-833. In pMBMEC, a 2.0- to 2.5-fold efflux ratio was observed in the transcellular transport of quinidine. The P-gp-mediated vectorial transport of quinidine was eliminated by PSC-833. These results indicate that quinidine with PSC-833 is a good probe substrate-reference inhibitor combination for testing drug-drug interactions with P-gp in the in vivo and in vitro mouse systems. With increasing number of humanized transgenic mice, a test system with mouse microdialysis experimentation becomes more important to predict drug-drug interactions in humans.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Barreira Hematoencefálica/metabolismo , Microdiálise/métodos , Anestesia , Animais , Transporte Biológico , Células Cultivadas , Ciclosporinas/metabolismo , Interações Medicamentosas , Células Endoteliais/metabolismo , Estudos de Viabilidade , Humanos , Masculino , Camundongos , Quinidina/metabolismo , Quinidina/farmacocinética , Ratos , Especificidade por Substrato , Fatores de Tempo
3.
J Biomol Screen ; 16(8): 886-94, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21832259

RESUMO

This study provides evidence that quinidine can be used as a probe substrate for ABCB1 in multiple experimental systems both in vitro and in vivo relevant to the blood-brain barrier (BBB). The combination of quinidine and PSC-833 (valspodar) is an effective tool to assess investigational drugs for interactions on ABCB1. Effects of quinidine and substrate-inhibitor interactions were tested in a membrane assay and in monolayer assays. The authors compared quinidine and digoxin as ABCB1 probes in the in vitro assays and found that quinidine was more potent and at least as specific as digoxin in ATPase and monolayer efflux assays employing MDCKII-MDR1 and the rat brain microcapillary endothelial cell system. Brain exposure to quinidine was tested in dual-/triple-probe microdialysis experiments in rats by assessing levels of quinidine in blood and brain. Comparing quinidine levels in dialysate samples from valspodar-treated and control animals, it is evident that systemic/local administration of the inhibitor diminishes the pumping function of ABCB1 at the BBB, resulting in an increased brain penetration of quinidine. In sum, quinidine is a good probe to study ABCB1 function at the BBB. Moreover, quinidine/PSC-833 is an ABCB1-specific substrate/inhibitor combination applicable to many assay systems both in vitro and in vivo.


Assuntos
Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Barreira Hematoencefálica/efeitos dos fármacos , Encéfalo/efeitos dos fármacos , Avaliação Pré-Clínica de Medicamentos/métodos , Células Endoteliais/efeitos dos fármacos , Endotélio Vascular/efeitos dos fármacos , Ensaios de Triagem em Larga Escala , Subfamília B de Transportador de Cassetes de Ligação de ATP/antagonistas & inibidores , Animais , Produtos Biológicos/análise , Barreira Hematoencefálica/metabolismo , Encéfalo/citologia , Encéfalo/metabolismo , Linhagem Celular , Cromatografia Líquida de Alta Pressão , Técnicas de Cocultura , Ciclosporinas/farmacologia , Digoxina/farmacologia , Cães , Combinação de Medicamentos , Interações Medicamentosas , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Endotélio Vascular/citologia , Endotélio Vascular/metabolismo , Inibidores Enzimáticos/farmacologia , Imunossupressores/farmacologia , Masculino , Microdiálise , Quinidina/farmacologia , Ratos , Ratos Wistar
4.
Clin Lab ; 57(11-12): 983-92, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22239031

RESUMO

BACKGROUND: Cyclosporin A, sirolimus, tacrolimus, and everolimus are immunosuppressive drugs used for therapy after organ transplantation. There are several analytical procedures for monitoring the drug level in blood, e.g. immunological methods and high-performance liquid chromatography combined with mass spectrometry (MS). From external quality assessment schemes, it became evident that the analytical results show high dispersion and further standardization is required. METHODS: Liquid/liquid extraction of the drugs from whole blood samples was performed using ammonium acetate buffer, pH 9.5, and tert-butylmethyl ether/ethyl acetate (1:1 v/v). Separation of the immunosuppressive drugs was achieved by HPLC using a phenyl-hexyl-RP column with a ternary gradient elution profile, consisting of water, methanol, and acetonitrile containing 0.1% v/v formic acid and 0.1 mmol/L Cs+. Quantification of immunosuppressive drugs was performed by isotope-dilution mass spectrometry using [2H12]-Cyclosporin A [13C, 2H3]-Rapamycin, [13C, 2H2]-Tacrolimus, and [13C2, 2H4]-42-O-(2-Hydroxyethyl)rapamycin as internal standards. RESULTS: The recovery of the new procedure was determined by analysis of spiked blood samples. The recovery in spiked EDTA whole blood samples was 100.8 - 102.5% for cyclosporin A, 101.6 - 103.0% for sirolimus, 100.0 - 101.2% for tacrolimus, and 99.5 - 102.4% for everolimus. The imprecision of the new measurement procedure, expressed as the coefficient of variation (CV), was 1.17 - 2.60% for cyclosporin A in the concentration range between 8.1 and 979 microg/L, 0.92 - 1.72% for sirolimus in the concentration range between 2.1 and 33.2 microg/L, 0.44 - 1.06% for tacrolimus in the concentration range between 2.0 and 30.8 microg/L and 0.82 - 4.34% for everolimus in the concentration range between 2.1 and 31.4 microg/L. CONCLUSIONS: An isotope dilution LC-MS/MS procedure for determination of four immunosuppressive drugs was developed to provide a basis for further development toward a reference measurement procedure.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos/métodos , Imunossupressores/sangue , Espectrometria de Massas/métodos , Calibragem , Isótopos de Carbono/análise , Ciclosporina/sangue , Deutério/análise , Monitoramento de Medicamentos/normas , Everolimo , Humanos , Técnicas de Diluição do Indicador , Sirolimo/análogos & derivados , Sirolimo/sangue , Tacrolimo/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...