Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Cancers (Basel) ; 14(19)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36230690

RESUMO

Background: Residual viable tumor cells after ablation at the tumor periphery serve as the source for tumor recurrence, leading to treatment failure. Purpose: To develop a novel three-dimensional (3D) multi-modal perfusion-thermal electrode system completely eradicating medium-to-large malignancies. Materials and Methods: This study included five steps: (i) design of the new system; (ii) production of the new system; (iii) ex vivo evaluation of its perfusion-thermal functions; (iv) mathematic modeling and computer simulation to confirm the optimal temperature profiles during the thermal ablation process, and; (v) in vivo technical validation using five living rabbits with orthotopic liver tumors. Results: In ex vivo experiments, gross pathology and optical imaging demonstrated the successful spherical distribution/deposition of motexafin gadolinium administered through the new electrode, with a temperature gradient from the electrode core at 80 °C to its periphery at 42 °C. An excellent repeatable correlation of temperature profiles at varying spots, from the center to periphery of the liver tumor, was found between the mathematic simulation and actual animal tumor models (Pearson coefficient ≥0.977). For in vivo validation, indocyanine green (ICG) was directly delivered into the peritumoral zones during simultaneous generation of central tumoral lethal radiofrequency (RF) heat (>60 °C) and peritumoral sublethal RF hyperthermia (<60 °C). Both optical imaging and fluorescent microscopy confirmed successful peritumoral ICG distribution/deposition with increased heat shock protein 70 expression. Conclusion: This new 3D, perfusion-thermal electrode system provided the evidence on the potential to enable simultaneous delivery of therapeutic agents and RF hyperthermia into the difficult-to-treat peritumoral zones, creating a new strategy to address the critical limitation, i.e., the high incidence of residual and recurrent tumor following thermal ablation of unresectable medium-to-large and irregular tumors.

2.
Cardiovasc Intervent Radiol ; 43(9): 1392-1397, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32444921

RESUMO

INTRODUCTION: Protein-losing enteropathy manifests as a loss of serum proteins through the gastrointestinal tract, resulting in hypoproteinemia, extravascular fluid retention, and edema. Management consists of nutritional maintenance in conjunction with interventions targeted at treating the underlying etiology. MATERIALS AND METHODS: This report describes a patient with protein-losing enteropathy from a central conducting lymphatic obstruction who was treated with percutaneous extra-anatomic lymphovenous bypass creation. RESULTS: A modified gun-sight technique was used to create a lymphovenous bypass between an occluded terminal thoracic duct and the left internal jugular vein. CONCLUSION: A percutaneous technique to reconstruct the terminal thoracic duct via lymphovenous bypass creation was feasible.


Assuntos
Veias Braquiocefálicas/cirurgia , Veias Jugulares/cirurgia , Enteropatias Perdedoras de Proteínas/cirurgia , Ducto Torácico/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Anastomose Cirúrgica/métodos , Humanos , Linfografia/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Enteropatias Perdedoras de Proteínas/diagnóstico , Ducto Torácico/diagnóstico por imagem
3.
Radiographics ; 40(2): 562-588, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32125955

RESUMO

US is a powerful and nearly ubiquitous tool in the practice of interventional radiology. Use of contrast-enhanced US (CEUS) has gained traction in diagnostic imaging given the recent approval by the U.S. Food and Drug Administration (FDA) of microbubble contrast agents for use in the liver, such as sulfur hexafluoride lipid-type A microspheres. Adoption of CEUS by interventional radiologists can enhance not only procedure guidance but also preprocedure patient evaluation and assessment of treatment response across a wide spectrum of oncologic, vascular, and nonvascular procedures. In addition, the unique physical properties of microbubble contrast agents make them amenable as therapeutic vehicles in themselves, which can lay a foundation for future therapeutic innovations in the field in drug delivery, thrombolysis, and vascular flow augmentation. The purpose of this article is to provide an introduction to and overview of CEUS aimed at the interventional radiologist, highlighting its role before, during, and after frequently practiced oncologic and vascular interventions such as biopsy, ablation, transarterial chemoembolization, detection and control of hemorrhage, evaluation of transjugular intrahepatic portosystemic shunts (TIPS), detection of aortic endograft endoleak, thrombus detection and evaluation, evaluation of vascular malformations, lymphangiography, and percutaneous drain placement. Basic physical principles of CEUS, injection and scanning protocols, and logistics for practice implementation are also discussed. Early adoption of CEUS by the interventional radiology community will ensure rapid innovation of the field and development of future novel procedures. Online supplemental material is available for this article. ©RSNA, 2020.


Assuntos
Meios de Contraste/administração & dosagem , Ultrassonografia de Intervenção , Humanos , Microbolhas
4.
J Invasive Cardiol ; 32(2): 76-81, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31958070

RESUMO

OBJECTIVES: We compared virtual-reality guided versus fluoroscopy-guided transseptal puncture by novice and experienced operators in a cardiac phantom. Outcome measures included accuracy, time, transseptal path distance, and a survey of the operator experience. METHODS: A transseptal simulator was created using a Plexiglas case and a 3D-printed cardiac phantom with a replaceable fossa ovalis, a customized support, and an electromagnetic tracking system. A precisely registered virtual-reality rendering was constructed. To display the transseptal instruments in virtual reality, we attached electromagnetic sensors to standard transseptal instruments, including the needle, dilator, and sheath. Each subject completed 6 simulated transseptal punctures (3 fluoroscopy-guided and 3 virtual-reality guided). We measured the distance traversed by the transseptal needle, accuracy, and time for each simulated transseptal puncture. Operators were then surveyed regarding their experience. RESULTS: A total of 8 subjects (6 faculty, 2 fellows) completed the trial. We found that virtual-reality guidance resulted in significantly more accurate puncture site selection and, subjectively, was more intuitive for the operator, particularly for novices. None of the participants experienced negative symptoms in virtual reality that required cessation of the procedure. CONCLUSIONS: Virtual reality compared with fluoroscopic guidance for transseptal puncture shows considerable promise, particularly for novice trainees, where it could lessen the learning curve. Current barriers to widespread implementation are discussed.


Assuntos
Septo Interatrial/cirurgia , Fluoroscopia/métodos , Complicações Intraoperatórias , Imagens de Fantasmas , Punções , Cirurgia Assistida por Computador , Realidade Virtual , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Educação , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Curva de Aprendizado , Punções/efeitos adversos , Punções/métodos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos
5.
Ultrasound Med Biol ; 44(9): 1996-2008, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29941214

RESUMO

This study addresses inactivation of E. coli in either 5- or 10-mL volumes, which were 50- to 100-fold greater than used in an earlier study (Brayman et al. 2017). Cells were treated with 1-MHz pulsed high-intensity focused ultrasound (10 cycles, 2-kHz repetition frequency, +65/-12.8 MPa focal pressures). The surviving fraction was assessed by coliform assay, and inactivation demonstrated curvilinear kinetics. The reduction of surviving fraction to 50% required 2.5 or 6 min in 5- or 10-mL samples, respectively. Exposure of 5 mL for 20 min reduced the surviving fraction to ∼1%; a similar exposure of 10-mL samples reduced the surviving fraction to ∼10%. Surviving cells from 5-min exposures appeared normal under light microscopy, with minimal debris; after 20 min, debris dominated. Transmission electron microscopy images of insonated samples showed some undamaged cells, a few damaged but largely intact cells and comminuted debris. Cellular damage associated with substantive but incomplete levels of inactivation can be variable, ranging from membrane holes tens of nanometers in diameter to nearly complete comminution.


Assuntos
Escherichia coli , Ondas de Choque de Alta Energia , Plâncton , Sobrevivência Celular , Células Cultivadas , Cinética , Microscopia Eletrônica de Transmissão
6.
Diagn Interv Radiol ; 23(6): 454-460, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29097347

RESUMO

PURPOSE: We aimed to demonstrate feasibility of the use of a dual-balloon infusion microcatheter for segmental/subsegmental drug-eluting bead transarterial chemoembolization (DEB-TACE). METHODS: Over a 16-month period, 15 segmental and 21 subsegmental DEB-TACE procedures were attempted using a dual-balloon anti-reflux microcatheter (IsoFlow™ microcatheter, Vascular Designs Inc.) in 21 patients (15 males; median age, 61 years; range, 49-82 years) with hepatocellular carcinoma (Barcelona clinic liver cancer stage A [n=4]; B [n=12]; C [n=5]) with one to three tumors, median size of 3.4 cm (1.2-9 cm). Follow-up enhanced computed tomography or magnetic resonance imaging was obtained at one month then subsequently every three months for one year. Technical success was evaluated. Modified RECIST criteria was used for target tumor response assessment. Safety was evaluated by assessing for arterial injury and hepatic injury at the time of the procedure and subsequent evidence of complications and liver toxicity. RESULTS: In 26 of the procedures, the segmental/subsegmental arteries were thought not to be easily selected with standard microcatheters due to the arterial branches being severely tortuous/angulated or atretic from prior TACE or anti-angiogenic therapy or could not be catheterized. Radiologic response assessment of treated tumors demonstrated 32% complete response, 19% partial response, 34% stable disease, and 15% progressive disease. No complications occurred. The median time to progression for the targeted tumors was 7 months (range, 3-12 months). CONCLUSION: DEB-TACE, using this dual-balloon anti-reflux infusion microcatheter is feasible and safe.


Assuntos
Carcinoma Hepatocelular/terapia , Catéteres , Quimioembolização Terapêutica/instrumentação , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
7.
Ultrasound Med Biol ; 43(7): 1476-1485, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28454842

RESUMO

This study was motivated by the desire to develop a non-invasive means to treat abscesses, and represents the first steps toward that goal. Non-thermal, high-intensity focused ultrasound (HIFU) was used to inactivate Escherichia coli (∼1 × 109 cells/mL) in suspension. Cells were treated in 96-well culture plate wells using 1.95-MHz ultrasound and incident focal acoustic pressures as high as 16 MPa peak positive and 9.9 MPa peak negative (free field measurements). The surviving fraction was assessed by coliform culture and the alamarBlue assay. No biologically significant heating was associated with ultrasound exposure. Bacterial inactivation kinetics were well described by a half-life model, with a half-time of 1.2 min. At the highest exposure levels, a 2log inactivation was typically achieved within 10 min. The free field-equivalent peak negative acoustic pressure threshold for inactivation was ∼7 MPa. At the highest acoustic pressures used, inactivation efficacy was insensitive to reciprocal changes in pulse length and pulse repetition frequency at constant duty factor. Although treated volumes were very small, proof of principle was provided by these experiments.


Assuntos
Escherichia coli/efeitos da radiação , Viabilidade Microbiana/efeitos da radiação , Plâncton/efeitos da radiação , Sonicação/métodos , Esterilização/métodos , Relação Dose-Resposta a Droga , Escherichia coli/fisiologia , Estudos de Viabilidade , Plâncton/fisiologia , Doses de Radiação
8.
J Vasc Interv Radiol ; 28(6): 777-785.e1, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28365172

RESUMO

PURPOSE: To compare segmental radioembolization with segmental chemoembolization for localized, unresectable hepatocellular carcinoma (HCC) not amenable to ablation. MATERIALS AND METHODS: In a single-center, retrospective study (2010-2015), 101 patients with 132 tumors underwent segmental radioembolization, and 77 patients with 103 tumors underwent segmental doxorubicin-based drug-eluting embolic or conventional chemoembolization. Patients receiving chemoembolization had worse performance status (Eastern Cooperative Oncology Group 0, 76% vs 56%; P = .003) and Child-Pugh class (class A, 65% vs 52%; P = .053); patients receiving radioembolization had larger tumors (32 mm vs 26 mm; P < .001), more infiltrative tumors (23% vs 9%; P = .01), and more vascular invasion (18% vs 1%; P < .001). Toxicity, tumor response, tumor progression, and survival were compared. Analyses were weighted using a propensity score (PS). RESULTS: Toxicity rates were low, without significant differences. Index and overall complete response rates were 92% and 84% for radioembolization and 74% and 58% for chemoembolization (P = .001 and P < .001). Index tumor progression at 1 and 2 years was 8% and 15% in the radioembolization group and 30% and 42% in the chemoembolization group (P < .001). Median progression-free and overall survival were 564 days and 1,198 days in the radioembolization group and 271 days and 1,043 days in the chemoembolization group (PS-adjusted P = .002 and P = .35; censored by transplant PS-adjusted P < .001 and P = .064). CONCLUSIONS: Segmental radioembolization demonstrates higher complete response rates and local tumor control compared with segmental chemoembolization for HCC, with similar toxicity profiles. Superior progression-free survival was achieved.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Doxorrubicina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Pontuação de Propensão , Compostos Radiofarmacêuticos/uso terapêutico , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
9.
J Vasc Interv Radiol ; 27(8): 1123-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27321889

RESUMO

PURPOSE: To determine safety and efficacy of yttrium-90 ((90)Y) transarterial radioembolization (TARE) in patients who have undergone chemoembolization for hepatocellular carcinoma. MATERIALS AND METHODS: A retrospective study identified 40 patients (median age 61 y; range, 44-84 y) who underwent (90)Y mapping angiography and had undergone ≥ one prior chemoembolizations. There were 4 (10%) patients in Barcelona Clinic Liver Cancer stage A, 7 (17.5%) in stage B, and 29 (72.5%) in stage C; 28 (70%) were Child-Pugh class A and 12 (30%) were class B. Median tumor diameter was 4.2 cm (range, 1-11.6 cm). The most common indications for changing to TARE were tumor progression (35/40; 86%) and development of portal vein thrombus (15/40; 37.5%). RESULTS: Of 40 patients, 29 (72.5%) underwent TARE; the most common reasons for not undergoing TARE were attenuated hepatic arteries (5/11), high pulmonary shunt (4/11), and poor arterial flow (2/11). Patients who underwent ≤ 4 chemoembolizations to the TARE target tended to be more likely to undergo TARE after mapping than patients who had > 4 chemoembolizations (P = .056). Most common grade ≥ 3 toxicities were fatigue (9/29; 31%) and biochemical alterations (bilirubin [3/29; 10.3%], albumin [4/29; 13.8%], aspartate aminotransferase [5/29; 17.2%]). Of 27 patients treated with TARE with follow-up, responses were 11 (41%) complete response, 5 (19%) partial response, 2 (7%) stable disease, and 9 (33%) progressive disease. Median progression-free survival and overall survival were 90 days and 257 days. CONCLUSIONS: TARE is safe and effective salvage therapy in patients after chemoembolization. In patients who have undergone > 4 chemoembolizations to the (90)Y target, feasibility of TARE tends to be decreased.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Compostos Radiofarmacêuticos/administração & dosagem , Radioisótopos de Ítrio/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Quimioembolização Terapêutica/mortalidade , Intervalo Livre de Doença , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Modelos de Riscos Proporcionais , Radiografia Intervencionista , Compostos Radiofarmacêuticos/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Terapia de Salvação , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral , Radioisótopos de Ítrio/efeitos adversos
10.
Ultrasound Med Biol ; 42(7): 1491-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27126244

RESUMO

Intra- and extra-muscular hematomas result from repetitive injury as well as sharp and blunt limb trauma. The clinical consequences can be serious, including debilitating pain and functional deficit. There are currently no short-term treatment options for large hematomas, only lengthy conservative treatment. The goal of this work was to evaluate the feasibility of a high intensity focused ultrasound (HIFU)-based technique, termed histotripsy, for rapid (within a clinically relevant timeframe of 15-20 min) liquefaction of large volume (up to 20 mL) extra-vascular hematomas for subsequent fine-needle aspiration. Experiments were performed using in vitro extravascular hematoma phantoms-fresh bovine blood poured into 50 mL molds and allowed to clot. The resulting phantoms were treated by boiling histotripsy (BH), cavitation histotripsy (CH) or a combination in a degassed water tank under ultrasound guidance. Two different transducers operating at 1 MHz and 1.5 MHz with f-number = 1 were used. The liquefied lysate was aspirated and analyzed by histology and sized in a Coulter Counter. The peak instantaneous power to achieve BH was lower than (at 1.5 MHz) or equal to (at 1 MHz) that which was required to initiate CH. Under the same exposure duration, BH-induced cavities were one and a half to two times larger than the CH-induced cavities, but the CH-induced cavities were more regularly shaped, facilitating easier aspiration. The lysates contained a small amount of debris larger than 70 µm, and 99% of particulates were smaller than 10 µm. A combination treatment of BH (for initial debulking) and CH (for liquefaction of small residual fragments) yielded 20 mL of lysate within 17.5 minutes of treatment and was found to be most optimal for liquefaction of large extravascular hematomas.


Assuntos
Hematoma/cirurgia , Procedimentos Cirúrgicos Ultrassônicos/métodos , Técnicas In Vitro , Imagens de Fantasmas
11.
Diagn Interv Radiol ; 22(3): 257-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27015445

RESUMO

PURPOSE: We aimed to evaluate the safety and effectiveness of a novel catheter-based mechanical thrombectomy device, XCOILTM, as a first line therapy to restore patency of thrombosed dialysis grafts and fistulae. METHODS: In 2010, 18 consecutive/sequential patients (11 male, 7 female; median age, 52 years; age range, 32-69 years) with occluded arteriovenous grafts (n=15) or fistulae (n=3) were treated with XCOILTM (NexGen Medical Systems Inc.) without adjunctive thrombolytic drugs. XCOILTM was advanced distal to the thrombus within the outflow vein as well as distal to the arterial inflow platelet thrombin plug, using a 4F angiographic catheter. The percentage of thrombus cleared, primary patency, procedure time, and XCOILTM performance were documented. RESULTS: Thrombosis occurred 1-30 days prior to the procedure. Thrombosed segments of graft/fistula measured 10-50 cm. Pre- and postprocedure angiography demonstrated that in 15 of 18 cases (83%) XCOILTM removed 80%-100% of the venous outflow thrombus. In 11 of 14 cases (79%), the platelet thrombin plug was also removed. Thrombectomy procedure time averaged 8 min, with one to three passes with the XCOILTM required. No evidence of distal embolization or graft/vessel injury was found on angiography following clot removal. In four cases in whom patency was not restored with XCOILTM, subsequent use of other clot removal devices also failed to restore patency. In one case with severe venous stenosis, the device failed to deploy and the thrombus was not captured. No intraprocedural complications related to XCOILTM use occurred. CONCLUSION: XCOILTM is an effective and safe first-line therapy option for the treatment of thrombosed hemodialysis grafts/fistulae. Rapid removal of intact thrombus and platelet thrombin plug can be achieved without adjunctive thrombolytics.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Trombólise Mecânica/instrumentação , Diálise Renal/efeitos adversos , Trombose Venosa/terapia , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/métodos , Feminino , Oclusão de Enxerto Vascular/etiologia , Humanos , Masculino , Trombólise Mecânica/efeitos adversos , Trombólise Mecânica/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Trombose Venosa/etiologia
12.
Radiat Res ; 185(2): 182-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26771172

RESUMO

Induction of vascular hyperpermeability is one of the early vascular responses to radiation exposure and is considered to contribute to subsequent fibrosis and tissue injuries. However, the mechanism underlying radiation-induced hyperpermeability has not yet been clearly elucidated. Here, we provide experimental evidence indicating that mast cells contribute to the increase in vascular permeability for albumin in normal mouse skin after irradiation. Vascular permeability in the skin of C3H mice increased after 2, 15 and 50 Gy irradiation, peaked at 24 h after irradiation and gradually decreased thereafter to the baseline level within 3-10 days. Both the extent and duration of hyperpermeability were dose dependent. We found significant degranulation of mast cells in the skin after 15 Gy irradiation. To further investigate the role of mast cells in the radiation-induced increase in vascular permeability, we measured vascular permeability in the skin of mast cell-deficient mice (WW(v)) and their wild-type littermates at 24 h after irradiation. Vascular permeability in WW(v) mice did not change, whereas that in wild-type mice significantly increased after irradiation. There were no appreciable changes in the total tissue levels of vascular endothelial growth factor or endothelial nitric oxide synthase after 15 Gy irradiation and there was no detectable expression of inducible nitric oxide synthase. Collectively, these results show that exposure to radiation induces vascular hyperpermeability in a dose-dependent manner and that mast cells contribute to this process.


Assuntos
Permeabilidade Capilar/fisiologia , Permeabilidade Capilar/efeitos da radiação , Mastócitos/fisiologia , Mastócitos/efeitos da radiação , Albumina Sérica/metabolismo , Fenômenos Fisiológicos da Pele/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Endotélio Vascular/patologia , Endotélio Vascular/fisiologia , Endotélio Vascular/efeitos da radiação , Camundongos , Camundongos Endogâmicos C3H , Permeabilidade/efeitos da radiação , Doses de Radiação , Pele/irrigação sanguínea , Pele/metabolismo , Pele/efeitos da radiação
13.
Cardiovasc Intervent Radiol ; 38(4): 913-21, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25373795

RESUMO

PURPOSE: Locoregional therapy for hepatocellular carcinoma (HCC) can be challenging in patients with a transjugular intrahepatic portosystemic shunt (TIPS). This study compares safety and imaging response of ablation, chemoembolization, radioembolization, and supportive care in patients with both TIPS and HCC. METHODS: This retrospective study included 48 patients who had both a TIPS and a diagnosis of HCC. Twenty-nine of 48 (60%) underwent treatment for HCC, and 19/48 (40%) received best supportive care (i.e., symptomatic management only). While etiology of cirrhosis and indication for TIPS were similar between the two groups, treated patients had better baseline liver function (34 vs. 67% Child-Pugh class C). Tumor characteristics were similar between the two groups. A total of 39 ablations, 17 chemoembolizations, and 10 yttrium-90 radioembolizations were performed on 29 patients. RESULTS: Ablation procedures resulted in low rates of hepatotoxicity and clinical toxicity. Post-embolization/ablation syndrome occurred more frequently in patients undergoing chemoembolization than ablation (47 vs. 15%). Significant hepatic dysfunction occurred more frequently in the chemoembolization group than the ablation group. Follow-up imaging response showed objective response in 100% of ablation procedures, 67% of radioembolization procedures, and 50% of chemoembolization procedures (p = 0.001). When censored for OLT, patients undergoing treatment survived longer than patients receiving supportive care (2273 v. 439 days, p = 0.001). CONCLUSIONS: Ablation appears to be safe and efficacious for HCC in patients with TIPS. Catheter-based approaches are associated with potential increased toxicity in this patient population. Chemoembolization appears to be associated with increased toxicity compared to radioembolization.


Assuntos
Braquiterapia , Carcinoma Hepatocelular/terapia , Ablação por Cateter , Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Derivação Portossistêmica Transjugular Intra-Hepática , Adulto , Idoso , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
14.
J Vasc Interv Radiol ; 25(7): 1067-73, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24837982

RESUMO

PURPOSE: To assess the safety and efficacy of yttrium-90 ((90)Y) radioembolization when performed in a superselective fashion for patients with unresectable hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This retrospective study included 20 patients with unresectable HCC. Median Model for End-Stage Liver Disease score was 10.5 (range, 6-25), with 8 of 20 patients (40%) classified Child-Pugh class B and 1 of 20 patients (5%) classified class C cirrhosis. Segmental tumor-associated portal vein thrombus was present in 12 patients (60%), and a transjugular intrahepatic portosystemic shunt was present in 4 patients (20%). Median tumor diameter was 3.9 cm (range, 2.5-7.1 cm). All patients underwent superselective (90)Y radioembolization targeted to a single liver segment using glass microspheres. RESULTS: Median dose to the treated segment was 254 Gy, and median dose to the tumor was 536 Gy. No grade 3-4 hepatotoxicity occurred. The most common clinical toxicities were fatigue (30%), abdominal pain (10%), and postembolization syndrome (10%). Follow-up imaging demonstrated complete European Association for the Study of the Liver response of the index tumor in 19 of 20 patients (95%) and stable disease in 1 of 20 patients (5%). In patients with complete response, local tumor recurrence rate was 5.3% (1 of 19 patients). Median time to progression was 319 days. Overall survival was 90% (18 of 20 patients) with a median follow-up period of 275 days (range, 32-677 d). CONCLUSIONS: When performed in a segmental fashion, (90)Y radioembolization demonstrates high response rates and low local tumor recurrence rates. Complete imaging response can be achieved in patients with locally aggressive disease. This study demonstrates no clinically significant hepatotoxicity, despite moderate liver dysfunction in many patients.


Assuntos
Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/radioterapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/radioterapia , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Idoso , Angiografia Digital , Carcinoma Hepatocelular/mortalidade , Progressão da Doença , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Seleção de Pacientes , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos/efeitos adversos , Dosagem Radioterapêutica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral , Radioisótopos de Ítrio/efeitos adversos
15.
Acad Radiol ; 21(3): 407-14, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24507428

RESUMO

The aim of this review was to describe quality of life (QoL) questionnaires relevant to interventional radiology. Interventional radiologists perform a large number of palliative procedures. The effect of these therapies on QoL is important. This is particularly true for cancer therapies where procedures with marginal survival benefits may result in tremendous QoL benefits. Image-guided minimally invasive procedures should be compared to invasive procedures, with respect to QoL, as part of comparative effectiveness assessment. A large number of questionnaires have been validated for measurement of overall and disease-specific quality of life. Use of applicable QoL assessments can aid in evaluating clinical outcomes and help to further substantiate the need for minimally invasive image-guided procedures.


Assuntos
Avaliação de Resultados em Cuidados de Saúde/métodos , Qualidade de Vida/psicologia , Radiografia Intervencionista/psicologia , Radiografia Intervencionista/estatística & dados numéricos , Radiologia Intervencionista/estatística & dados numéricos , Inquéritos e Questionários , Humanos
16.
J Ultrasound Med ; 32(10): 1789-97, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24065260

RESUMO

OBJECTIVES: Ultrasound backscatter microscopy (UBM), or ultrasound biomicroscopy, is a noninvasive, label-free, and ionizing radiation-free technique allowing high-resolution 3-dimensional structural imaging. The goal of this study was to evaluate UBM for resolving anatomic features associated with squamous cell carcinoma of the oral cavity. METHODS: The study was conducted in a hamster buccal pouch model. A carcinogen was topically applied to cheeks of 14 golden Syrian hamsters. Six additional hamsters served as healthy controls. A high-frequency (41 MHz, 6-mm focal depth, lateral and axial resolutions of 65 and 37 µm, respectively) UBM system was used for scanning the oral cavity after 14 weeks of carcinogen application. Histologic analyses were conducted on scanned regions. RESULTS: The histologic structure of buccal tissue and microvasculature networks could be visualized from the UBM images. Epithelial and mucosal hypertrophy and neoplastic changes were identified in animals subjected to the carcinogen. In animals with invasive squamous cell carcinoma, lesion development and destruction of the structural integrity of tissue layers were noted. CONCLUSIONS: In this pilot study, UBM generated sufficient contrast for morphologic features associated with oral carcinoma compared to healthy tissue. This modality may present a practical technique for detection of oral neoplasms that is potentially translatable to humans.


Assuntos
Aumento da Imagem/métodos , Microscopia Acústica/métodos , Neoplasias Bucais/diagnóstico , Neoplasias de Células Escamosas/diagnóstico , Animais , Cricetinae , Mesocricetus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Anticancer Res ; 32(11): 4951-61, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23155265

RESUMO

BACKGROUND: Response Evaluation Criteria in Solid Tumors (RECIST)-defined measurements are limited when evaluating soft tissue sarcoma (STS) response to therapy. Histopathological assessment of STS response requires a determination of necrosis following resection. A novel semi-automated technique for volumetric measurement of tumor necrosis, using enhanced magnetic resonance imaging (CE-MRI), is described. PATIENTS AND METHODS: Eighteen patients with STS were treated with neoadjuvant therapy and then resected. CE-MRI, obtained prior to resection, were evaluated by two observers using semi-automated segmentation. Tumor volume and percent necrosis was compared with histology and RECIST measurements. RESULTS: The median percent necrosis, determined histologically and from CE-MRI, was 71.9% and 67.8%, respectively. Accuracy of these semi-automated measurements was confirmed, being statistically similar to those obtained at histopathological assessment of the resected tumor. High Intra-class correlation co-efficients suggest good inter-observer reproducibility. Tumor necrosis did not correlate with the RECIST measurements. CONCLUSION: Semi-automated determination of tumor volume and necrosis, using CE-MRI, is suggested to be accurate and reproducible.


Assuntos
Imageamento por Ressonância Magnética/métodos , Sarcoma/patologia , Neoplasias de Tecidos Moles/patologia , Algoritmos , Meios de Contraste , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Reprodutibilidade dos Testes
18.
J Biomed Opt ; 17(11): 116003, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23117798

RESUMO

Tissue diagnostic features generated by a bimodal technique integrating scanning time-resolved fluorescence spectroscopy (TRFS) and ultrasonic backscatter microscopy (UBM) are investigated in an in vivo hamster oral carcinoma model. Tissue fluorescence is excited by a pulsed nitrogen laser and spectrally and temporally resolved using a set of filters/dichroic mirrors and a fast digitizer, respectively. A 41-MHz focused transducer (37-µm axial, 65-µm lateral resolution) is used for UBM scanning. Representative lesions of the different stages of carcinogenesis show that fluorescence characteristics complement ultrasonic features, and both correlate with histological findings. These results demonstrate that TRFS-UBM provide a wealth of co-registered, complementary data concerning tissue composition and structure as it relates to disease status. The direct co-registration of the TRFS data (sensitive to surface molecular changes) with the UBM data (sensitive to cross-sectional structural changes and depth of tumor invasion) is expected to play an important role in pre-operative diagnosis and intra-operative determination of tumor margins.


Assuntos
Microscopia Acústica/métodos , Neoplasias Bucais/diagnóstico , Espectrometria de Fluorescência/métodos , Animais , Cricetinae , Modelos Animais de Doenças , Desenho de Equipamento , Masculino , Mesocricetus , Microscopia Acústica/instrumentação , Neoplasias Bucais/patologia , Invasividade Neoplásica/diagnóstico , Invasividade Neoplásica/patologia , Fenômenos Ópticos , Espalhamento de Radiação , Espectrometria de Fluorescência/instrumentação
19.
Insights Imaging ; 3(1): 49-60, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22695998

RESUMO

OBJECTIVES: To describe persistent nephrographic patterns detected by unenhanced renal CT at 24 h after cardiac catheterisation and intervention. METHODS: This prospective study was Health Insurance Portability and Accountability Act-compliant and institutional review board approved. Twenty-nine patients (20 men, nine women; average age 63.27 and range 41-85 years) agreed to undergo unenhanced dual-energy computed tomography (CT) limited to their kidneys at 24 h after cardiac catheterisation. CT attenuation values (Hounsfield units) were made from the cortical and medullary regions and single kidney total parenchymal iodine values (milligrams) were measured. Spearman's rank correlation coefficient and a two-sided Fisher's exact test were used in the statistics. RESULTS: Focal nephrograms were observed in at least one kidney (range, one to five regions per kidney) in 10/29 (34%) of patients and bilateral global nephrograms in 13/29 (45%) of patients. Focal nephrograms correlated with cardiac catheterisation fluoroscopic time (r = 0.48; P = 0.0087). For global nephrograms, the total iodine content of right and left kidneys correlated with fluoroscopic time (r = 0.79 and 0.76; P < 0.0001, respectively) and the amount of contrast material (CM) used (r = 0.77 and r = 0.74; P < 0.0001, respectively). CONCLUSION: Persistent focal and global nephrograms occur commonly as assessed by non-contrast CT at 24 h post cardiac catheterisation and our observations suggest they could be related to procedural factors.

20.
Radiographics ; 31(5): 1449-62, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21918055

RESUMO

The term nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Much of the ongoing research and development of nanotechnology is focused on the development of novel methods of imaging and delivery of therapeutics through minimally invasive means. Multifunctional nanoparticles offer great promise for molecular imaging and directing novel therapeutics to molecular targets, which was never before possible. Nanoparticle-based contrast agents have been developed for all imaging modalities. A rapidly increasing number of companies and government funding initiatives have led to a large number of novel agents in various stages of development, ranging from in vitro and in vivo animal studies to clinical use. However, barriers to the delivery of nanoparticles for tumor imaging and therapy exist. Interventional radiologists may circumvent these barriers by using imaging to guide delivery of nanoparticles.


Assuntos
Nanotecnologia , Radiologia Intervencionista/educação , Radiologia/educação , Animais , Meios de Contraste , Diagnóstico por Imagem/métodos , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/farmacocinética , Sistemas de Liberação de Medicamentos , Organização do Financiamento , Humanos , Injeções Intralesionais , Imagem Molecular/métodos , Imagem Molecular/tendências , Nanopartículas/administração & dosagem , Nanopartículas/efeitos adversos , Nanotecnologia/economia , Nanotecnologia/educação , Nanotecnologia/métodos , Nanotecnologia/tendências , Neoplasias/tratamento farmacológico , Radiologia Intervencionista/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...