1.
Opt Express ; 30(26): 46991-47003, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36558637

RESUMO

Longwave downward radiation measurements are fundamental for investigating the surface and atmospheric energy budget of the Earth. Such measurements are performed using broadband infrared radiometers that have a hemispherical acceptance angle. A new hemispherical reference blackbody has been developed to provide a new traceability path of longwave downward radiation measurements to the SI. The Hemispherical Blackbody (HSBB) was specifically designed to meet the large opening angle of radiometers used for measuring longwave downward radiation. The first step was to find a suitable design candidate for the HSBB by simulating the effective emissivity using the Monte Carlo ray-tracing software STEEP. The most promising candidate was then realized in two versions with similar coatings and both versions were taken into operation.

2.
Opt Express ; 24(23): 25911-25921, 2016 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-27857330

RESUMO

The absolute responsivity of a planar cryogenic radiometer fabricated from micromachined silicon and having carbon nanotubes, as the absorber and thermistor were measured in the visible and far infrared (free-field terahertz) wavelength range by means of detector-based radiometry. The temperature coefficient of the thermistor near 4.8 K and noise equivalent power were evaluated along with independent characterization of the window transmittance and specular reflectance of the nanotube absorber. Measurements of absolute power by means of electrical substitution are compared to the German national standard and the uncertainty of the radiometer responsivity as a function of wavelength is summarized.

3.
Metrologia ; 53(Technical Suppl)2016.
Artigo em Inglês | MEDLINE | ID: mdl-28239193

RESUMO

The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 µm to 14 µm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process.

4.
Opt Express ; 23(9): 11170-82, 2015 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-25969213

RESUMO

A superconducting transition edge sensor (TES) bolometer operating in the spectral range from 0.1 THz to 3 THz was designed. It is especially intended for Fourier transform spectroscopy and features a higher dynamic range and a highly linear response at a similar response compared to commercially available silicon composite bolometers. The design is based on a thin film metal mesh absorber, a superconducting thermistor and Si3N4 membrane technology. A prototype was set up, characterized and successfully used in first applications.

5.
Opt Express ; 22(21): 25071-83, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25401540

RESUMO

The suitability of a commercially available Fourier transform spectrometer equipped with a fiber-coupled global entrance optic as a reference spectroradiometer for the measurement of spectral solar ultraviolet irradiance at ground level has been investigated. The instrument has been characterized with respect to the wavelength uncertainty, and a calibration of the spectral irradiance responsivity has been performed by using the calculable irradiance of a high temperature black-body radiator and by using a secondary irradiance standard lamp. The relative standard uncertainty of solar irradiance measurements in the wavelength range from 310 nm to 400 nm with this spectroradiometer, based on the described methodology, is 1.6% for solar zenith angles of less than 60°.


Assuntos
Análise de Fourier , Análise Espectral/instrumentação , Raios Ultravioleta , Calibragem , Propriedades de Superfície , Incerteza
6.
Opt Express ; 21(12): 14466-73, 2013 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-23787634

RESUMO

The metrology institute in Germany, the Physikalisch-Technische Bundesanstalt (PTB), calibrates the spectral responsivity of THz detectors at 2.52 THz traceable to International System of Units. The Terahertz detector calibration facility is equipped with a standard detector calibrated against a cryogenic radiometer at this frequency. In order to extend this service to a broader spectral range in the THz region a new standard detector was developed. This detector is based on a commercial thermopile detector. Its absorber was modified and characterized by spectroscopic methods with respect to its absorptance and reflectance from 1 THz to 5 THz and at the wavelength of a helium-neon laser in the visible spectral range. This offers the possibility of tracing back the THz power responsivity scale to the more accurate responsivity scale in the visible spectral range and thereby to reduce the uncertainty of detector calibrations in the THz range significantly.


Assuntos
Transferência de Energia , Fotometria/instrumentação , Fotometria/normas , Radiação Terahertz , Termografia/instrumentação , Termografia/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade
7.
Anal Chem ; 84(9): 3889-98, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22376085

RESUMO

The development of fluorescence applications in the life and material sciences has proceeded largely without sufficient concern for the measurement uncertainties related to the characterization of fluorescence instruments. In this first part of a two-part series on the state-of-the-art comparability of corrected emission spectra, four National Metrology Institutes active in high-precision steady-state fluorometry performed a first comparison of fluorescence measurement capabilities by evaluating physical transfer standard (PTS)-based and reference material (RM)-based calibration methods. To identify achievable comparability and sources of error in instrument calibration, the emission spectra of three test dyes in the wavelength region from 300 to 770 nm were corrected and compared using both calibration methods. The results, obtained for typical spectrofluorometric (0°/90° transmitting) and colorimetric (45°/0° front-face) measurement geometries, demonstrated a comparability of corrected emission spectra within a relative standard uncertainty of 4.2% for PTS- and 2.4% for RM-based spectral correction when measurements and calibrations were performed under identical conditions. Moreover, the emission spectra of RMs F001 to F005, certified by BAM, Federal Institute for Materials Research and Testing, were confirmed. These RMs were subsequently used for the assessment of the comparability of RM-based corrected emission spectra of field laboratories using common commercial spectrofluorometers and routine measurement conditions in part 2 of this series (subsequent paper in this issue).

8.
Opt Express ; 18(21): 21804-14, 2010 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-20941081

RESUMO

Precision power measurements of terahertz (THz) radiation are required to establish metrological applications in the THz spectral range. However, traceability to the International System of Units (SI) has been missing in the THz region in the past. The Physikalisch-Technische Bundesanstalt (PTB), as the national metrology institute of Germany, determines the spectral responsivity of detectors for THz radiation by using two complementary optical methods: source- and detector-based radiometry. Both approaches have been successfully prototyped, and a pyroelectric THz detector with a well-defined aperture is used to verify the consistency of the two independent calibration methods. These primary investigations led to the design of a new measurement facility for the determination of THz radiant power and the responsivity calibration of THz detectors traceable to the SI.


Assuntos
Óptica e Fotônica , Radiação Terahertz , Espectroscopia Terahertz/métodos , Algoritmos , Calibragem , Desenho de Equipamento , Radiometria/métodos , Espectrofotometria Infravermelho/métodos , Temperatura , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...