Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol Exp ; 8(1): 38, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38499843

RESUMO

BACKGROUND: Intravoxel incoherent motion (IVIM)-corrected diffusion tensor imaging (DTI) potentially enhances return-to-play (RTP) prediction after hamstring injuries. However, the long scan times hamper clinical implementation. We assessed accelerated IVIM-corrected DTI approaches in acute hamstring injuries and explore the sensitivity of the perfusion fraction (f) to acute muscle damage. METHODS: Athletes with acute hamstring injury received DTI scans of both thighs < 7 days after injury and at RTP. For a subset, DTI scans were repeated with multiband (MB) acceleration. Data from standard and MB-accelerated scans were fitted with standard and accelerated IVIM-corrected DTI approach using high b-values only. Segmentations of the injury and contralateral healthy muscles were contoured. The fitting methods as well as the standard and MB-accelerated scan were compared using linear regression analysis. For sensitivity to injury, Δ(injured minus healthy) DTI parameters between the methods and the differences between injured and healthy muscles were compared (Wilcoxon signed-rank test). RESULTS: The baseline dataset consisted of 109 athletes (16 with MB acceleration); 64 of them received an RTP scan (8 with MB acceleration). Linear regression of the standard and high-b DTI fitting showed excellent agreement. With both fitting methods, standard and MB-accelerated scans were comparable. Δ(injured minus healthy) was similar between standard and accelerated methods. For all methods, all IVIM-DTI parameters except f were significantly different between injured and healthy muscles. CONCLUSIONS: High-b DTI fitting with MB acceleration reduced the scan time from 11:08 to 3:40 min:s while maintaining sensitivity to hamstring injuries; f was not different between healthy and injured muscles. RELEVANCE STATEMENT: The accelerated IVIM-corrected DTI protocol, using fewer b-values and MB acceleration, reduced the scan time to under 4 min without affecting the sensitivity of the quantitative outcome parameters to hamstring injuries. This allows for routine clinical monitoring of hamstring injuries, which could directly benefit injury treatment and monitoring. KEY POINTS: • Combining high-b DTI-fitting and multiband-acceleration dramatically reduced by two thirds the scan time. • The accelerated IVIM-corrected DTI approaches maintained the sensitivity to hamstring injuries. • The IVIM-derived perfusion fraction was not sensitive to hamstring injuries.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física)
2.
NMR Biomed ; 36(7): e4902, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36630472

RESUMO

MRI examinations are accurate for diagnosing sports-related acute hamstring injuries. However, sensitive imaging methods for assessing recovery of these injuries are lacking. Diffusion tensor imaging (DTI) and quantitative T2 (qT2) mapping have both shown promise for assessing recovery of muscle micro trauma and exercise effects. The purpose of this study was to explore the potential of DTI and qT2 mapping for monitoring the muscle recovery processes after acute hamstring injury. In this prospective study, athletes with an acute hamstring injury underwent a 3-T MRI examination of the injured and contralateral hamstrings including DTI and qT2 measurements at three time points: (1) within 1 week after sustaining the injury, (2) 2 weeks after time point 1, and (3) return to play (RTP). A linear mixed model was used for time-effect analysis and paired t-tests for the detection of differences between injured and uninjured muscles. Forty-one athletes (age 27.8 ± 7 years; two females and 39 males) were included. Mean RTP time was 50 (range 12-169) days. A significant time effect was found for mean diffusivity, radial diffusivity, and the second and third eigenvalues (p ≤ 0.001) in the injured muscles. Fractional anisotropy (p = 0.40), first eigenvalue (p = 0.02), and qT2 (p = 0.61) showed no significant time effect. All DTI indices, except for fractional anisotropy, were significantly elevated compared with control muscles right after the injury (p < 0.001). Values normalized during the recovery period, with no significant differences between control and injured muscles at RTP (p values ranged from 0.08 to 0.51). Mean qT2 relaxation times in injured muscles were not significantly elevated compared with control muscles at any time point (p > 0.04). In conclusion, DTI can be used to monitor recovery after an acute hamstring injury. Future work should explore the potential of DTI indices to predict RTP and recovery times in athletes after an acute strain injury.


Assuntos
Imagem de Tensor de Difusão , Músculos Isquiossurais , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Músculos Isquiossurais/diagnóstico por imagem
4.
NMR Biomed ; 34(1): e4406, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001508

RESUMO

Diffusion tensor imaging (DTI) is becoming a relevant diagnostic tool to understand muscle disease and map muscle recovery processes following physical activity or after injury. Segmenting all the individual leg muscles, necessary for quantification, is still a time-consuming manual process. The purpose of this study was to evaluate the impact of a supervised semi-automatic segmentation pipeline on the quantification of DTI indices in individual upper leg muscles. Longitudinally acquired MRI datasets (baseline, post-marathon and follow-up) of the upper legs of 11 subjects were used in this study. MR datasets consisted of a DTI and Dixon acquisition. Semi-automatic segmentations for the upper leg muscles were performed using a transversal propagation approach developed by Ogier et al on the out-of-phase Dixon images at baseline. These segmentations were longitudinally propagated for the post-marathon and follow-up time points. Manual segmentations were performed on the water image of the Dixon for each of the time points. Dice similarity coefficients (DSCs) were calculated to compare the manual and semi-automatic segmentations. Bland-Altman and regression analyses were performed, to evaluate the impact of the two segmentation methods on mean diffusivity (MD), fractional anisotropy (FA) and the third eigenvalue (λ3 ). The average DSC for all analyzed muscles over all time points was 0.92 ± 0.01, ranging between 0.48 and 0.99. Bland-Altman analysis showed that the 95% limits of agreement for MD, FA and λ3 ranged between 0.5% and 3.0% for the transversal propagation and between 0.7% and 3.0% for the longitudinal propagations. Similarly, regression analysis showed good correlation for MD, FA and λ3 (r = 0.99, p < 60; 0.0001). In conclusion, the supervised semi-automatic segmentation framework successfully quantified DTI indices in the upper-leg muscles compared with manual segmentation while only requiring manual input of 30% of the slices, resulting in a threefold reduction in segmentation time.


Assuntos
Algoritmos , Imagem de Tensor de Difusão , Processamento de Imagem Assistida por Computador , Músculo Esquelético/diagnóstico por imagem , Automação , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
5.
Physiol Rep ; 8(17): e14543, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32869950

RESUMO

Lipids, stored as intracellular triacylglycerol droplets within the myocardium, serve as an important source of energy, particularly in times of prolonged increased energy expenditure. In only a few studies, the acute effects of exercise on such ectopic myocardial lipid storage were investigated. We studied the dynamic behavior of the myocardial lipid pool in response to completing the 2017 Amsterdam Marathon using proton magnetic resonance (MR) spectroscopy (1 H-MRS). We hypothesized that the prolonged increased myocardial energy demand of running a marathon could shift the balance of myocardial triacylglycerol turnover from triacylglycerol synthesis toward lipolysis and mitochondrial fatty acid ß-oxidation, and decrease the myocardial lipid pool. We employed two 3 Tesla MR systems in parallel to noninvasively examine endurance-trained healthy men (n = 8; age 50.7 [50.1-52.7] y) at 1 week prior (baseline), <6 hr after finishing the marathon (post-marathon), and 2 weeks thereafter (recovery). Exercise intensity was 89 ± 6% of the age-predicted maximal heart rate, with a finish time of 3:56 [3:37-4:42] h:min. Myocardial lipid content was 0.66 [0.58-0.87]% of the total myocardial water signal at baseline, was lower post-marathon (0.47 [0.41-0.63]% of the total myocardial water signal), and had restored to 0.55 [0.49-0.83]% of the total myocardial water signal at recovery, representing a transient marathon running-induced depletion of 29 ± 24% (p = .04). The magnitude of this myocardial lipid pool depletion did not correlate with exercise intensity (r = -0.39; p = .39), nor with marathon finishing time (ρ = 0.57; p = .15). Our data show that prolonged high-intensity exercise can induce a transient depletion of the myocardial lipid pool, reinforcing the dynamic nature of ectopic triacylglycerol storage under real-life conditions of extreme endurance exercise.


Assuntos
Corrida de Maratona/fisiologia , Miocárdio/metabolismo , Triglicerídeos/metabolismo , Treino Aeróbico , Humanos , Masculino , Pessoa de Meia-Idade
6.
J Magn Reson Imaging ; 52(2): 407-417, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32144857

RESUMO

BACKGROUND: The majority of sports-related injuries involve skeletal muscle. Unlike acute trauma, which is often caused by a single traumatic event leading to acute symptoms, exercise-induced microtrauma may remain subclinical and difficult to detect. Therefore, novel methods to detect and localize subclinical exercise-induced muscle microtrauma are desirable. PURPOSE: To assess acute and delayed microstructural changes in upper leg muscles with multiparametric quantitative MRI after running a marathon. STUDY TYPE: Longitudinal; 1-week prior, 24-48 hours postmarathon and 2-week follow-up POPULATION: Eleven men participants (age: 47-68 years). FIELD STRENGTH/SEQUENCE: Spin-echo echo planar imaging (SE-EPI) with diffusion weighting, multispin echo, Dixon, and fat-suppressed turbo spin-echo (TSE) sequences at 3T. MR datasets and creatine kinase (CK) concentrations were obtained at three timepoints. ASSESSMENT: Diffusion parameters, perfusion fractions, and quantitative (q)T2 values were determined for hamstring and quadriceps muscles, TSE images were scored for acute injury. The vastus medialis and biceps femoris long head muscles were divided and analyzed in five segments to assess local damage. STATISTICAL TESTS: Differences between timepoints in MR parameters were assessed with a multilevel linear mixed model and in CK concentrations with a Friedman test. Mean diffusivity (MD) and qT2 for whole muscle and muscle segments were compared using a multivariate analysis of covariance (MANCOVA). RESULTS: CK concentrations were elevated (1194 U/L [166-3906], P < 0.001) at 24-48 hours postmarathon and returned to premarathon values (323 U/L [56-2216]) at 2-week follow-up. Most of the MRI diffusion indices in muscles without acute injury changed at 24-48 hours postmarathon and returned to premarathon values at follow-up (MD, RD, and λ3; P < 0.006). qT2 values (P = 0.003) and perfusion fractions (P = 0.003) were higher at baseline compared to follow-up. Local assessments of MD and qT2 revealed more pronounced changes than whole muscle assessment (2-3-fold; P < 0.01). DATA CONCLUSION: Marathon running-induced microtrauma was detected with MRI in individual whole upper leg muscles and even more pronounced on local segments. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3 J. Magn. Reson. Imaging 2020;52:407-417.


Assuntos
Perna (Membro) , Corrida de Maratona , Idoso , Imagem Ecoplanar , Humanos , Perna (Membro)/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem
8.
Eur Radiol ; 30(3): 1709-1718, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31705253

RESUMO

OBJECTIVES: Assessment of the repeatability of diffusion parameter estimations in the upper leg muscles of healthy adults over the time course of 2 weeks, from a simultaneous bilateral upper leg DTI measurement. METHODS: SE-EPI DTI datasets were acquired at 3 T in the upper legs of 15 active adults at a time interval of 2 weeks. ROIs were manually drawn for four quadriceps and three hamstring muscles of both legs. The following DTI parameters were analyzed: 1st, 2nd, and 3rd eigenvalue (λ1, λ2, and λ3), mean diffusivity (MD), and fractional anisotropy (FA). DTI parameters per muscle were calculated with and without intravoxel incoherent motion (IVIM) correction together with SNR levels per muscle. Bland-Altman plots and within-subject coefficient of variation (wsCV) were calculated. Left-right differences between muscles were assessed. RESULTS: The Bland-Altman analysis showed good repeatability of all DTI parameters except FA for both the IVIM-corrected and standard data. wsCV values show that MD has the highest repeatability (4.5% IVIM; 5.6% standard), followed by λ2 (4.9% IVIM; 5.5% standard), λ1 (5.3% IVIM; 7.5% standard), and λ3 (5.7% IVIM; 5.7% standard). wsCV values of FA were 15.2% for the IVIM-corrected data and 13.9% for the standard analysis. The SNR (41.8 ± 16.0 right leg, 41.7 ± 17.1 left leg) and wsCV values were similar for the left and right leg and no left-right bias was detected. CONCLUSIONS: Repeatability was good for standard DTI data and slightly better for IVIM-corrected DTI data. Our protocol is suitable for DTI of the upper legs with overall good SNR. KEY POINTS: • The presented DTI protocol is repeatable and therefore suitable for bilateral DT imaging of the upper legs. • Additional B1+calibrations improve SNR and repeatability. • Correcting for perfusion effects improves repeatability.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Perna (Membro)/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...