Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Electr Bioimpedance ; 13(1): 73-77, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36479358

RESUMO

The following case study demonstrates that the effectiveness of Deep Tissue Massage (DTM) can be monitored in real time with bioimpedance. DTM techniques are used as a medical treatment to help reduce swelling of the calves of congestive heart failure patients. Bioimpedance monitoring shows immediately how fluid is redistributed within the intravascular, interstitial and intracellular fluid compartments, and how long the redistribution lasts. Bioimpedance spectroscopy, as used in this study, is a non-invasive procedure that can be used to monitor compartment fluid volumes and changes during many fluid management procedures.

2.
J Electr Bioimpedance ; 12(1): 103-116, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35069946

RESUMO

Positive end-expiratory pressure (PEEP) is a respiratory/ventilation procedure that is used to maintain or improve breathing in clinical and experimental cases that exhibit impaired lung function. Body fluid shift movement is not monitored during PEEP application in intensive care units (ICU), which would be interesting specifically in hypotensive patients. Brain injured and hypotensive patients are known to have compromised cerebral blood flow (CBF) autoregulation (AR) but currently, there is no non-invasive way to assess the risk of implementing a hypotensive resuscitation strategy and PEEP use in these patients. The advantage of electrical bioimpedance measurement is that it is noninvasive, continuous, and convenient. Since it has good time resolution, it is ideal for monitoring in intensive care units (ICU). The basis of its future use is to establish physiological correlates. In this study, we demonstrate the use of electrical bioimpedance measurement during bleeding and the use of PEEP in pig measurement. In an anesthetized pig, we performed multimodal recording on the torso and head involving electrical bioimpedance spectroscopy (EIS), fixed frequency impedance plethysmography (IPG), and bipolar (rheoencephalography - REG) measurements and processed data offline. Challenges (n=16) were PEEP, bleeding, change of SAP, and CO2 inhalation. The total measurement time was 4.12 hours. Systemic circulatory results: Bleeding caused a continuous decrease of SAP, cardiac output (CO), and increase of heart rate, temperature, shock index (SI), vegetative - Kerdo index (KI). Pulse pressure (PP) decreased only after second bleeding which coincided with loss of CBF AR. Pulmonary arterial pressure (PAP) increased during PEEP challenges as a function of time and bleeding. EIS/IPG results: Body fluid shift change was characterized by EIS-related variables. Electrical Impedance Spectroscopy was used to quantify the intravascular, interstitial, and intracellular volume changes during the application of PEEP and simulated hemorrhage. The intravascular fluid compartment was the primary source of blood during hemorrhage. PEEP produced a large fluid shift out of the intravascular compartment during the first bleeding period and continued to lose more blood following the second and third bleeding. Fixed frequency IPG was used to quantify the circulatory responses of the calf during PEEP and simulated hemorrhage. PEEP reduced the arterial blood flow into the calf and venous outflow from the calf. Head results: CBF AR was evaluated as a function of SAP change. Before bleeding, and after moderate bleeding, intracranial pressure (ICP), REG, and carotid flow pulse amplitudes (CFa) increased. This change reflected vasodilatation and active CBF AR. After additional hemorrhaging during PEEP, SAP, ICP, REG, CFa signal amplitudes decreased, indicating passive CBF AR. 1) The indicators of active AR status by modalities was the following: REG (n=9, 56 %), CFa (n=7, 44 %), and ICP (n=6, 38 %); 2) CBF reactivity was better for REG than ICP; 3) REG and ICP correlation coefficient were high (R2 = 0.81) during CBF AR active status; 4) PRx and REGx reflected active CBF AR status. CBF AR monitoring with REG offers safety for patients by preventing decreased CBF and secondary brain injury. We used different types of bioimpedance instrumentation to identify physiologic responses in the different parts of the body (that have not been discussed before) and how the peripheral responses ultimately lead to decreased cardiac output and changes in the head. These bioimpedance methods can improve ICU monitoring, increase the adequacy of therapy, and decrease mortality and morbidity.

3.
J Electr Bioimpedance ; 10(1): 40-46, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33584881

RESUMO

This paper describes a new combined impedance plethysmographic (IPG) and electrical bioimpedance spectroscopic (BIS) instrument and software that will allow noninvasive real-time measurement of segmental blood flow, intracellular, interstitial, and intravascular volume changes during various fluid management procedures. The impedance device can be operated either as a fixed frequency IPG for the quantification of segmental blood flow and hemodynamics or as a multi-frequency BIS for the recording of intracellular and extracellular resistances at 40 discrete input frequencies. The extracellular volume is then deconvoluted to obtain its intravascular and interstitial component volumes as functions of elapsed time. The purpose of this paper is to describe this instrumentation and to demonstrate the information that can be obtained by using it to monitor segmental compartment volume responses of a pig model during simulated hemorrhage and resuscitation. Such information may prove valuable in the diagnosis and management of rapid changes in the body fluid balance and various clinical treatments.

4.
Hemodial Int ; 21(4): 575-584, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27860119

RESUMO

Introduction The aim of this paper is to describe and demonstrate how a new bioimpedance analytical procedure can be used to monitor cellular hydration of End Stage Renal Disease (ESRD) patients during hemodialysis (HD). Methods A tetra-polar bioimpedance spectroscope (BIS), (UFI Inc., Morro Bay, CA), was used to measure the tissue resistance and reactance of the calf of 17 ESRD patients at 40 discrete frequencies once a minute during dialysis treatment. These measurements were then used to derive intracellular, interstitial, and intravascular compartment volume changes during dialysis. Findings The mean (± SD) extracellular resistance increased during dialysis from 92.4 ± 3.5 to 117.7 ± 5.8 Ohms. While the mean intracellular resistance decreased from 413.5 ± 11.7 to 348.5 ± 8.2 Ohms. It was calculated from these data that the mean intravascular volume fell 9.5%; interstitial volume fell 33.4%; and intracellular volume gained 20.3%. Discussion These results suggest that an extensive fluid shift into the cells may take place during HD. The present research may contribute to a better understanding of how factors that influence fluid redistribution may affect an ESRD patient during dialysis. In light of this finding, it is concluded that the rate of vascular refill is jointly determined with the rate of "cellular refill" and the transfer of fluid from the intertitial compartment into the intravascular space.


Assuntos
Impedância Elétrica/uso terapêutico , Hipotensão/prevenção & controle , Falência Renal Crônica/terapia , Diálise Renal/métodos , Idoso , Animais , Bovinos , Feminino , Humanos , Hipotensão/terapia , Masculino
5.
Med Biol Eng Comput ; 51(10): 1167-75, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23549923

RESUMO

The bioimpedance spectroscopic (BIS) analytical algorithm described in this report allows for the non-invasive measurement of intravascular, interstitial, and intracellular volume changes during various fluid management procedures. The purpose of this study was to test clinical use feasibility and to demonstrate the validity of the BIS algorithm in computing compartmental volume shifts in human subjects undergoing fluid management treatment. Validation was performed using volume changes recorded from 20 end stage renal disease patients. The validation procedure involved mathematically deriving post hoc hematocrit profiles from the BIS data-generated fluid redistribution time profiles. These derived hematocrit profiles were then compared to serial hematocrit values measured simultaneously by a CritLine(®) monitor during 60 routine hemodialysis sessions. Regression and Bland-Altman analyses confirm that the BIS algorithm can be used to reliably derive the continuous and real-time rates of change of the compartmental fluid volumes. Regression results yielded a R (2) > 0.99 between the two measures of hematocrit at different times during dialysis. The slopes of the regression equations at the different times were nearly identical, demonstrating an almost one-to-one correspondence between the BIS and CritLine(®) hematocrits. Bland-Altman analysis show that the BIS algorithm can be used interchangeably with the CritLine(®) monitor for the measurement of hematocrit. The present study demonstrates for the first time that BIS can provide real-time continuous measurements of compartmental intravascular, interstitial and intracellular fluid volume changes during fluid management procedures when used in conjunction with this new algorithm.


Assuntos
Espectroscopia Dielétrica/métodos , Diálise Renal/métodos , Idoso , Líquidos Corporais/fisiologia , Espectroscopia Dielétrica/instrumentação , Impedância Elétrica , Feminino , Hematócrito , Humanos , Espaço Intracelular , Falência Renal Crônica/terapia , Análise dos Mínimos Quadrados , Perna (Membro)/fisiologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...