Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Obstet Gynecol ; 226(4): 554.e1-554.e12, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34762863

RESUMO

BACKGROUND: The serial fetal monitoring recommended for women with high-risk pregnancies places a substantial burden on the patient, often disproportionately affecting underprivileged and rural populations. A telehealth solution that can empower pregnant women to obtain recommended fetal surveillance from the comfort of their own home has the potential to promote health equity and improve outcomes. We have previously validated a novel, wireless pregnancy monitor that can remotely capture fetal and maternal heart rates. However, such a device must also detect uterine contractions if it is to be used to robustly conduct remote nonstress tests. OBJECTIVE: This study aimed to describe and validate a novel algorithm that uses biopotential and acoustic signals to noninvasively detect uterine contractions via a wireless pregnancy monitor. STUDY DESIGN: A prospective, open-label, 2-center study evaluated simultaneous detection of uterine contractions by the wireless pregnancy monitor and an intrauterine pressure catheter in women carrying singleton pregnancies at ≥32 0/7 weeks' gestation who were in the first stage of labor (ClinicalTrials.gov Identifier: NCT03889405). The study consisted of a training phase and a validation phase. Simultaneous recordings from each device were passively acquired for 30 to 60 minutes. In a subset of the monitoring sessions in the validation phase, tocodynamometry was also deployed. Three maternal-fetal medicine specialists, blinded to the data source, identified and marked contractions in all modalities. The positive agreement and false-positive rates of both the wireless monitor and tocodynamometry were calculated and compared with that of the intrauterine pressure catheter. RESULTS: A total of 118 participants were included, 40 in the training phase and 78 in the validation phase (of which 39 of 78 participants were monitored simultaneously by all 3 devices) at a mean gestational age of 38.6 weeks. In the training phase, the positive agreement for the wireless monitor was 88.4% (1440 of 1692 contractions), with a false-positive rate of 15.3% (260/1700). In the validation phase, using the refined and finalized algorithm, the positive agreement for the wireless pregnancy monitor was 84.8% (2722/3210), with a false-positive rate of 24.8% (897/3619). For the subgroup who were monitored only with the wireless monitor and intrauterine pressure catheter, the positive agreement was 89.0% (1191/1338), with a similar false-positive rate of 25.4% (406/1597). For the subgroup monitored by all 3 devices, the positive agreement for the wireless monitor was significantly better than for tocodynamometry (P<.0001), whereas the false-positive rate was significantly higher (P<.0001). Unlike tocodynamometry, whose positive agreement was significantly reduced in the group with obesity compared with the group with normal weight (P=.024), the positive agreement of the wireless monitor did not vary across the body mass index groups. CONCLUSION: This novel method to noninvasively monitor uterine activity, via a wireless pregnancy monitoring device designed for self-administration at home, was more accurate than the commonly used tocodynamometry and unaffected by body mass index. Together with the previously reported remote fetal heart rate monitoring capabilities, this added ability to detect uterine contractions has created a complete telehealth solution for remote administration of nonstress tests.


Assuntos
Contração Uterina , Monitorização Uterina , Adolescente , Feminino , Monitorização Fetal/métodos , Promoção da Saúde , Humanos , Lactente , Gravidez , Estudos Prospectivos , Contração Uterina/fisiologia , Monitorização Uterina/métodos
2.
Tob Induc Dis ; 17: 44, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31516487

RESUMO

INTRODUCTION: The 2016 US Surgeon General's Report suggests that the use of electronic nicotine delivery systems (ENDS) is a fetal risk factor. However, no previous study has estimated their effect on adverse pregnancy outcomes. We assessed the prevalence of current ENDS use in pregnant women and explored the effect on birth weight and smallness-for-gestational-age (SGA), correcting for misclassification from nondisclosure of smoking status. METHODS: We conducted a cohort study with 248 pregnant women using questionnaire data and biomarkers (salivary cotinine, exhaled carbon monoxide, and hair nicotine). We evaluated the association between birth weight and the risk of SGA by applying multivariate linear and log-binomial regression to reproductive outcome data for 232 participants. Participants who did not disclose their smoking status were excluded from the referent group. Sensitivity analysis corrected for misclassification of smoking/ENDS use status. RESULTS: The prevalence of current ENDS use among pregnant women was 6.8% (95% CI: 4.4-10.2%); most of these (75%) were concurrent smokers. Using self-reports, the estimated risk ratio of SGA for ENDS users was nearly two times the risk in the unexposed (RR=1.9, 95% CI: 0.6-5.5), and over three times that for ENDS-only users versus the unexposed (RR=3.1, 95% CI: 0.8-11.7). Excluding from the referent group smokers who did not disclose their smoking status, the risk of SGA for ENDS-only use was 5 times the risk in the unexposed (RR=5.1, 95% CI: 1.1- 22.2), and almost four times for all types of ENDS users (RR=3.8, 95% CI: 1.3-11.2). SGA risk ratios for ENDS users, corrected for misclassification due to self-report, were 6.5-8.5 times that of the unexposed. CONCLUSIONS: Our data suggest that ENDS use is associated with an increased risk of SGA.

3.
Tob Induc Dis ; 17: 50, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31516493

RESUMO

INTRODUCTION: Public awareness of electronic nicotine delivery systems (ENDS) has increased over time, and the perception that ENDS offer a safer alternative to cigarettes may lead some pregnant women to use them to reduce cigarette smoking during pregnancy. No previous studies have used metabolite levels in hair to measure nicotine exposure for ENDS users during pregnancy. We aimed to measure and compare levels of nicotine, cotinine, and tobacco-specific nitrosamines (TSNAs) in hair samples from pregnant women who were current ENDS users, current smokers, and current non-smokers. We also aimed to estimate the association between ENDS use/smoking and smallness for gestational age (SGA). METHODS: We used hair specimens from pregnant women who were dual users (ENDS and cigarettes), smokers, and non-smokers from a prospective cohort study to estimate exposure to nicotine, cotinine, and TSNAs. The exposure biomarkers and self-reports of smoking and ENDS use were used in log-binomial regression models to estimate risk ratios (RRs) for SGA among offspring. RESULTS: Nicotine concentrations for pregnant dual users were not significantly different from those for smokers (11.0 and 10.6 ng/mg hair, respectively; p=0.58). Similarly, levels of cotinine, and TSNAs for pregnant dual users were not lower than those for smokers. The RR for SGA was similar for dual users and smokers relative to nonsmokers, (RR=3.5, 95% CI: 0.8-14.8) and (RR=3.3, 95% CI: 0.9-11.6), respectively. Using self-reports confirmed by hair nicotine, the RR values for dual ENDS users and smokers were 8.3 (95% CI: 1.0-69.1) and 7.3 (95% CI:1.0-59.0), respectively. CONCLUSIONS: We did not observe lower levels of nicotine, cotinine, and TSNAs for current dual users compared to smokers during pregnancy. The risk of SGA for offspring of pregnant dual users was similar to that for offspring of pregnant smokers. Future studies are needed to further estimate the magnitude of the association between ENDS use and smallness for gestational age.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...