Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; 35(4): e2200172, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35178769

RESUMO

A Z-scheme heterojunction with spatially separated cocatalysts is proposed for overcoming fundamental issues in photocatalytic water splitting, such as inefficient light absorption, charge recombination, and sluggish reaction kinetics. For efficient light absorption and interfacial charge separation, Z-scheme organic/inorganic heterojunction photocatalysts are synthesized by firmly immobilizing ultrathin g-C3 N4 on the surface of TiO2 hollow spheres via electrostatic interactions. Additionally, two cocatalysts, Pt and IrOx , are spatially separated along the Z-scheme charge-transfer pathway to enhance surface charge separation and reaction kinetics. The as-prepared Pt/g-C3 N4 /TiO2 /IrOx (PCTI) hollow sphere photocatalyst exhibits an exceptional H2 evolution rate of 8.15 mmol h-1 g-1 and a remarkable apparent quantum yield of 24.3% at 330 nm in the presence of 0.5 wt% Pt and 1.2 wt% IrOx cocatalysts on g-C3 N4 and TiO2 , respectively. Photoassisted Kelvin probe force microscopy is used to systematically analyze the Z-scheme charge-transfer mechanism within PCTI. Furthermore, the benefits of spatially separating cocatalysts in the PCTI system are methodically investigated in comparison to randomly depositing them. This work adequately demonstrates that the combination of a Z-scheme heterojunction and spatially separated cocatalysts can be a promising strategy for designing high-performance photocatalytic platforms for solar fuel production.

2.
Sci Rep ; 11(1): 15382, 2021 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-34321504

RESUMO

We investigated the effects of using a virtual reality smartphone-based head-mounted display (VR SHMD) device for 2 h on visual parameters. Fifty-eight healthy volunteers were recruited. The participants played games using VR SHMD or smartphones for 2 h on different days. Visual parameters including refraction, accommodation, convergence, stereopsis, and ocular alignment and measured choroidal thickness before and after the use of VR SHMD or smartphones were investigated. Subjective symptoms were assessed using questionnaires. We analyzed the differences in visual parameters before and after the use of VR SHMD or smartphones and correlations between baseline visual parameters and those after the use of the devices. Significant changes were observed in near-point convergence and accommodation, exophoric deviation, stereopsis, and accommodative lag after the use of VR SHMD but not after that of smartphones. The subjective discomfort associated with dry eye and neurologic symptoms were more severe in the VR group than in the smartphone group. There were no significant changes in refraction and choroidal thickness after the use of either of the two devices. The poorer the participants' accommodation and convergence ability the greater the resistance to changes in these visual parameters, and participants with a large exophoria were more prone to worsening of exophoria than those with a small exophoria.


Assuntos
Percepção de Profundidade/fisiologia , Exotropia/diagnóstico , Transtornos da Percepção/diagnóstico , Smartphone , Realidade Virtual , Acomodação Ocular/fisiologia , Adulto , Exotropia/epidemiologia , Exotropia/etiologia , Exotropia/patologia , Feminino , Humanos , Masculino , Transtornos da Percepção/epidemiologia , Transtornos da Percepção/etiologia , Transtornos da Percepção/fisiopatologia , Saúde Pública , Refração Ocular/fisiologia , Inquéritos e Questionários , Testes Visuais , Visão Binocular/fisiologia , Percepção Visual/fisiologia , Adulto Jovem
3.
Sci Rep ; 11(1): 5891, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33723316

RESUMO

To study the usefulness of virtual reality (VR)-based training for diagnosing strabismus. Fourteen residents in ophthalmology performed at least 30 VR training sessions to diagnose esotropia and exotropia. Examinations of real patients with esotropia or exotropia before and after the VR training were video-recorded and presented to a strabismus expert to assess accuracy and performance scores for measuring the deviation angle and diagnosing strabismus with anonymization. A feedback survey regarding the usefulness and ease of use of the VR application was conducted for participants. The mean age of the 14 ophthalmology residents (10 men and 4 women), was 29.7 years. Before VR training, participants showed a mean accuracy score of 14.50 ± 5.45 and a performance score of 9.64 ± 4.67 for measuring the deviation angle and diagnosing strabismus in real patients with strabismus. After VR training, they showed a significantly improved accuracy score of 22.14 ± 4.37 (p = 0.012) and a performance score of 15.50 ± 1.99 (p = 0.011). According to the survey, most participants agreed on the usefulness of VR applications. This study suggests that VR-based training improved ophthalmology residents' clinical diagnostic skills for strabismus in a short period.


Assuntos
Estrabismo/diagnóstico , Realidade Virtual , Adulto , Avaliação Educacional , Feminino , Humanos , Masculino , Inquéritos e Questionários
4.
RSC Adv ; 11(20): 12288-12305, 2021 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-35423745

RESUMO

Solar energy has long been regarded as a promising alternative and sustainable energy source. In this regard, photocatalysts emerge as a versatile paradigm that can practically transform solar energy into chemical energy. At present, unsatisfactory conversion efficiency is a major obstacle to the widespread deployment of photocatalysis technology. Many structural engineering strategies have been proposed to address the issue of insufficient activity for semiconductor photocatalysts. Among them, creation of yolk-shell nanostructures which possess many beneficial features, such as large surface area, efficient light harvesting, homogeneous catalytic environment and enhanced molecular diffusion kinetics, has attracted particular attention. This review summarizes the developments that have been made for the preparation and photocatalytic applications of yolk-shell nanostructures. Additional focus is placed on the realization of interfacial charge dynamics and the possibility of achieving spatial separation of charge carriers for this unique nanoarchitecture as charge transfer is the most critical factor determining the overall photocatalytic efficiency. A future perspective that can facilitate the advancement of using yolk-shell nanostructures in sophisticated photocatalytic systems is also presented.

5.
Ophthalmic Res ; 64(4): 567-576, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33080596

RESUMO

PURPOSE: This study was designed to determine whether the anterior scleral thickness is affected by axial elongation and to investigate the association between anterior scleral thickness and various ocular parameters in myopic eyes. METHODS: This cross-sectional study included 79 healthy myopic participants. Anterior scleral thickness was measured in 8 meridians (superior-nasal, superior, superior-temporal, temporal [T], inferior-temporal, inferior [I], inferior-nasal, and nasal [N]) using anterior segment optical coherence tomography. Bruch's membrane opening (BMO) area, width of ß-parapapillary atrophy with and without Bruch's membrane (PPA+BM and PPA-BM), and the global peripapillary and subfoveal choroidal thickness were additionally measured. Age- and sex-adjusted partial correlation analysis and linear regression analysis were performed to examine the effects of axial length and various ocular parameters on anterior scleral thickness in myopic eyes. RESULTS: The mean age of the included participants was 27.03 ± 2.70 years. Overall, the anterior scleral thickness varied topographically according to the meridians and distance from the scleral spur. In the partial correlation analysis controlled for the effect of age and sex, increasing axial length was related to anterior scleral thinning at several measurement points along the T, I, and N meridians. Among the several ocular parameters, multivariate linear regression analysis with age, sex, and axial length as covariates revealed that central corneal thickness, intraocular pressure, and BMO area were significantly associated with anterior scleral thickness. CONCLUSION: In conclusion, there was a close relationship between the anterior scleral thickness and several ocular parameters in myopic eyes. These features should be taken into consideration when managing myopia, and our results might have important implications for understanding the pathogenesis of scleral changes during axial elongation.


Assuntos
Miopia , Disco Óptico , Adulto , Lâmina Basilar da Corioide , Estudos Transversais , Humanos , Esclera , Tomografia de Coerência Óptica , Adulto Jovem
6.
BMC Ophthalmol ; 20(1): 147, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32295556

RESUMO

BACKGROUND: Healthy corneal epithelium acts as a barrier against damage to the deeper structures in the eye. Failure in the mechanisms of corneal epithelization can lead to persistent epithelial defects of the cornea (PEDs) and can compromise its function. Epidermal growth factor (EGF) promotes the proliferation, migration, and differentiation of epithelial cells, endothelial cells, and fibroblasts during wound healing and may be beneficial in treating patients with PEDs. We, therefore, investigated the effect of EGF ointment on patients with PEDs. METHODS: Fifteen patients with PEDs refractory to conventional treatment were treated twice a day with EGF ointment. Patient demographics and comorbidities were noted. The epithelial healing time was determined along with the primary outcome measures in the areas of the epithelial defects, visual acuity, visual analog scale (VAS) scores, and esthesiometer scores 1 month and 2 months after treatment. RESULTS: Five eyes of herpetic keratitis (33.3%), 3 eyes of dry eye disease (20.0%), 3 eyes of bacterial keratitis (20.0%), 2 eyes of limbal stem cell deficiency (13.3%), 1 eye of diabetic neurotrophic keratitis (6.7%), and 1 eye of filamentary keratitis (6.7%) were associated with PEDs, respectively. Two months following treatment with EGF ointment, there was a reduction in the area of the epithelial defects (5.7 ± 3.9 to 0.1 ± 0.3 mm2) as well as a significant improvement in best-corrected visual acuity (0.9 ± 0.8 to 0.6 ± 0.5 LogMAR) and VAS scores (4.5 ± 1.2 to 2.5 ± 0.7) in 12 eyes (80%). Among these cases, the mean epithelial healing time was 5.5 ± 1.8 weeks. Amniotic membrane transplantation was performed on the remaining 3 (20.0%) patients that did not respond to EGF treatment. CONCLUSIONS: EGF ointment could reduce symptoms and promotes corneal epithelialization of refractory PEDs. It may, therefore, be well-tolerated and a potentially beneficial addition in the management of refractory PEDs.


Assuntos
Doenças da Córnea/tratamento farmacológico , Fator de Crescimento Epidérmico/administração & dosagem , Epitélio Corneano/efeitos dos fármacos , Pomadas/administração & dosagem , Reepitelização/efeitos dos fármacos , Cicatrização/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Córnea/diagnóstico , Doenças da Córnea/fisiopatologia , Epitélio Corneano/patologia , Epitélio Corneano/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Acuidade Visual/fisiologia
7.
Medicine (Baltimore) ; 98(26): e16155, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31261544

RESUMO

To evaluate the characteristics of meibomian gland dysfunction (MGD) in patients with Stevens-Johnson Syndrome (SJS) and investigate the risk factors for severe MGD.Sixteen patients with a history of SJS were evaluated for MGD. To assess the SJS severity acute ocular involvement score (AOS), acute systemic involvement score (ASS), and chronic ocular manifestation score (COMS) were measured. Meibomian gland parameters were evaluated using meibomian gland dropout score (meiboscore - using a Keratograph 5 M), meibum expression score (MES), meibum quality score (MQS), and lid margin abnormality score (LMAS). Correlations between severity of meibomian gland parameters and degree of ocular and systemic involvement of SJS were analyzed. Risk factors for development of severe MGD were identified.The patients' mean age was 32.0 ±â€Š14.3 years. Four patients were men and 12 were women. MGD had developed in 14 patients (87.5%). The meibomian gland parameters were significantly correlated with ocular and systemic degree of SJS as evaluated using AOS (P < .01), ASS (P < .01), and COMS (P < .01). Patients with severe MGD had a higher AOS (P < .01) and COMS (P = .02) values than those without severe MGD. On multivariate analysis, AOS higher than 2 was a significant risk factor for developing severe MGD (P = .03).MGD was a common ocular manifestation with SJS patients. Severity of meibomian gland parameters was correlated with AOS, ASS, and COMS, and the presence of acute ocular complications was a risk factor for severe MGD in patients with SJS.


Assuntos
Doenças Palpebrais/epidemiologia , Doenças Palpebrais/fisiopatologia , Glândulas Tarsais/fisiopatologia , Síndrome de Stevens-Johnson/epidemiologia , Síndrome de Stevens-Johnson/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença
8.
Nanoscale ; 10(37): 17842-17851, 2018 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-30221273

RESUMO

Analyzing impact dynamics is important for practical applications of superhydrophobic surfaces, because these nonwetting surfaces frequently encounter impacting liquid droplets in real environments. Thus, various studies have been conducted to investigate impact dynamics by examining the correlation between the behaviors of impacting liquid droplets and several determining parameters, such as impacting velocity, surface structure and surface energy. The impacting behaviors of pure water droplets were the main focus in most previous studies; the effect of surface tension, another critical parameter, on impact dynamics has rarely been investigated. In the current work, we have newly studied the effects of liquid surface tension on impact dynamics using an ethanol-water solution as a model liquid system. We systematically varied the liquid's surface tension between 72 and 32 mN m-1 by changing the ethanol concentration from 0 to 20 wt%. This range of composition drastically changed the surface tension while it did not significantly affect other physical properties, such as density and viscosity. For an impact dynamics study, two surfaces, namely ZnO nanowires (NWs) and ZnO/Si hierarchical (HIE) structures, were prepared. As the surface tension decreased, the static water contact angle (CA) decreased on both surfaces. Under dynamic conditions, our analysis using a high-speed camera and a quartz crystal microbalance (QCM) showed that lowering the surface tension causes the transition from the anti-wetting to wetting state. The transition We numbers were obtained on both surfaces for various surface tensions of liquids. Under the same dropping conditions of liquids, the ZnO/Si HIE surface shows higher transition We numbers than the ZnO NW surface, which is due to the higher fraction of air pockets in the hierarchical structure, originating from dual dimensional structures. To understand the mechanism of dynamic transition, we developed a model for ZnO/Si HIE structures based on three determining pressures: anti-wetting, wetting, and effective water hammer pressures. The modeling results explain the experimental observations. The results of our model system are highly useful for understanding the impact dynamic behaviors of various liquids on non-wetting surfaces.

9.
J Colloid Interface Sci ; 320(1): 91-5, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18255089

RESUMO

A poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) fibrous surface with various bead-on-string structures was fabricated by electrospinning. PHBV was electrospun at various concentrations and then CF4 plasma treatment was employed to further improve the hydrophobicity of the PHBV fiber surfaces. The surface morphology of the electrospun PHBV mats was observed by scanning electron microscopy (SEM). The surface properties were characterized by water contact angle (WCA) measurements and X-ray photoelectron spectroscopy (XPS). The surface morphology of the electrospun PHBV fibrous mats with the bead-son-string structure varied with the solution concentration. The WCA of all of the electrospun PHBV mats was higher than that of the PHBV film. In particular, a very rough fiber surface including porous beads was observed when PHBV was electrospun from the solution with a concentration of 26 wt%. Also, its WCA further increased from 141 degrees to 158 degrees after CF(4) plasma treatment for 150 s. PHBV can be rendered superhydrophobic by controlling the surface morphology and surface energy, which can be achieved by adjusting the electrospinning and plasma treatment conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...