HPB (Oxford) ; 14(2): 98-102, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22221570

RESUMO

BACKGROUND: Irreversible electroporation (IRE) is a largely non-thermal method for the ablation of solid tumours. The ability of ultrasound (US) to measure the size of the IRE ablation zone was studied in a porcine liver model. METHODS: Three normal pig livers were treated in vivo with a total of 22 ablations using IRE. Ultrasound was used within minutes after ablation and just prior to liver harvest at either 6 h or 24 h after the procedure. The area of cellular necrosis was measured after staining with nitroblue tetrazolium and the percentage of cell death determined by histomorphometry. RESULTS: Visible changes in the hepatic parenchyma were apparent by US after all 22 ablations using IRE. The mean maximum diameter of the ablation zone measured by US during the procedure was 20.1 ± 2.7 mm. This compared with a mean cellular necrosis zone maximum diameter of 20.3 ± 2.9 mm as measured histologically. The mean percentage of dead cells within the ablation zone was 77% at 6 h and 98% at 24 h after ablation. CONCLUSIONS: Ultrasound is a useful modality for measuring the ablation zone within minutes of applying IRE to normal liver tissue. The area of parenchymal change measured by US correlates with the area of cellular necrosis.


Assuntos
Eletroporação , Fígado/diagnóstico por imagem , Animais , Feminino , Fígado/patologia , Modelos Animais , Necrose , Suínos , Fatores de Tempo , Ultrassonografia
2.
Surg Obes Relat Dis ; 7(1): 8-14, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21255733

RESUMO

BACKGROUND: Vertical gastric plication is a novel surgical approach for reducing the stomach capacity. Anterior surface plication and greater curvature plication are variations of vertical gastric plication that reduce the gastric capacity through infolding of the anterior surface or greater curvature of the stomach, respectively. These approaches have been tested, with positive results in a small number of preclinical and clinical trials. A key step toward greater investigation of vertical gastric plication as a viable bariatric procedure would be confirmation that the apposed serosal tissues can be securely and durably bonded. We compared the short-term durability of gastric plications and serosal bonds using a variety of fastening devices and techniques in a university hospital and private company setting. METHODS: A total of 30 anterior surface plication and 8 greater curvature plication procedures were performed using an open or a laparoscopic surgical technique in 38 hound dogs. The fastening devices used were T-tags, buttressed T-tags, 2 types of suture, and 4 types of staple-based fasteners. The density of the fastening devices was varied among the dogs. With 3 exceptions (2 in keeping with the study design and 1 due to complications), the dogs were followed up for 8 weeks. Histologic examinations and tensile testing were performed postmortem. RESULTS: All fastening devices created durable plication folds, except for 1 technique. The only technique that did not produce durable serosa-to-serosa adhesions was a staple/suture combination. Intentional abrasion of the apposed sites had no demonstrable effect on the bonds between the tissues in any group. Increasing the fastener density and number of rows increased the adhesions within the folds. CONCLUSION: Our findings have confirmed the short-term durability and development of dense fibrous appositions of the serosal folds for fastening approaches that create fixed serosal apposition. Additional studies are needed to identify the optimal fastening modality for anterior surface plication, greater curvature plication, and, ultimately, clinical applications of this procedure.


Assuntos
Fundoplicatura/métodos , Mucosa Gástrica/cirurgia , Obesidade Mórbida/cirurgia , Membrana Serosa/cirurgia , Animais , Modelos Animais de Doenças , Cães , Endoscopia Gastrointestinal/métodos , Masculino , Técnicas de Sutura
3.
J Surg Res ; 157(2): 279-83, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19765731

RESUMO

BACKGROUND: The purpose of this study was to evaluate the ability of Harmonic energy technology to transect and seal the pancreatic duct compared with the standard monopolar electrosurgery transection and oversew technique in a porcine distal pancreatectomy survival model. Harmonic energy technology is as effective as standard oversew technique for preventing pancreatic leak after distal pancreatectomy. METHODS: The animal protocol used for this study was approved by the Institutional Animal Care and Use Committee (IACUC) prior to the conduct of the study. Spleen-preserving distal pancreatectomy was performed in seven pigs (80-100 lb) by the same surgeon. In four animals, the pancreas was divided with the Harmonic Focus Curved Shears (test group) with no additional suturing for control of hemostasis or leak. In three animals, the pancreas was divided using monopolar electrosurgery (30 W coagulation) and the cut end of the pancreas was oversewn with a locking suture (control group). A previously worked out standard operative technique was used in all procedures. Operating end points included surgery time and blood loss. Animals were euthanized and necropsied at 7 to 8 d following surgery. Survival endpoints included clinical response to surgery, serum chemistry profiles before surgery and at necropsy, and histology of the pancreas transection site. RESULTS: Mean operative time for pancreatic resection was 15min in the control group and 10min in the test group. No significant blood loss was noted in either group. The median size of the resected pancreas was 4.3 cm. Three animals in the control group and three in the test group completed the study without complications. One animal in the test group failed to eat, appeared dehydrated, and was taken off study on POD#2. In this animal, there was a doubling of serum lipase at euthanasia and gross evidence of ileus, which was attributed to a pancreatic leak. Histologic examination of the residual pancreas in both groups at necropsy revealed a 2-5 mm band of necrotic tissue associated with neutrophilic infiltration in the control group, and less than a 1mm band of necrotic tissue in the test group. CONCLUSION: The Harmonic Focus Curved Shears, using Harmonic energy technology, appears to seal the pancreatic ducts and prevent pancreatic leak at 75% (3/4) efficiency in this survival model. However, the survival leak rate, 25% (1/4) was higher in the Harmonic Focus Curved Shears test group compared with the control oversewn group 0% (0/3). This feasibility study shows potential for Harmonic technology to be used to seal the pancreatic ducts, but additional testing and optimization of surgical techniques are needed.


Assuntos
Pancreatectomia/métodos , Ductos Pancreáticos/cirurgia , Terapia por Ultrassom/métodos , Animais , Eletrocirurgia/métodos , Eletrocirurgia/mortalidade , Estudos de Viabilidade , Feminino , Hemostasia Cirúrgica/métodos , Ligadura , Modelos Animais , Pancreatectomia/mortalidade , Taxa de Sobrevida , Suturas , Suínos , Terapia por Ultrassom/mortalidade