Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37447818

RESUMO

BACKGROUND: This review systematically examined the scientific literature about electroencephalogram-derived ratio indexes used to assess human mental involvement, in order to deduce what they are, how they are defined and used, and what their best fields of application are. (2) Methods: The review was carried out according to the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines. (3) Results: From the search query, 82 documents resulted. The majority (82%) were classified as related to mental strain, while 12% were classified as related to sensory and emotion aspects, and 6% to movement. The electroencephalographic electrode montage used was low-density in 13%, high-density in 6% and very-low-density in 81% of documents. The most used electrode positions for computation of involvement indexes were in the frontal and prefrontal cortex. Overall, 37 different formulations of involvement indexes were found. None of them could be directly related to a specific field of application. (4) Conclusions: Standardization in the definition of these indexes is missing, both in the considered frequency bands and in the exploited electrodes. Future research may focus on the development of indexes with a unique definition to monitor and characterize mental involvement.


Assuntos
Ondas Encefálicas , Eletroencefalografia , Humanos , Eletroencefalografia/métodos , Córtex Pré-Frontal , Eletrodos
2.
Sensors (Basel) ; 22(13)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35808382

RESUMO

BACKGROUND: Muscle co-contraction plays a significant role in motion control. Available detection methods typically only provide information in the time domain. The current investigation proposed a novel approach for muscle co-contraction detection in the time-frequency domain, based on continuous wavelet transform (CWT). METHODS: In the current study, the CWT-based cross-energy localization of two surface electromyographic (sEMG) signals in the time-frequency domain, i.e., the CWT coscalogram, was adopted for the first time to characterize muscular co-contraction activity. A CWT-based denoising procedure was applied for removing noise from the sEMG signals. Algorithm performances were checked on synthetic and real sEMG signals, stratified for signal-to-noise ratio (SNR), and then validated against an approach based on the acknowledged double-threshold statistical algorithm (DT). RESULTS: The CWT approach provided an accurate prediction of co-contraction timing in simulated and real datasets, minimally affected by SNR variability. The novel contribution consisted of providing the frequency values of each muscle co-contraction detected in the time domain, allowing us to reveal a wide variability in the frequency content between subjects and within stride. CONCLUSIONS: The CWT approach represents a relevant improvement over state-of-the-art approaches that provide only a numerical co-contraction index or, at best, dynamic information in the time domain. The robustness of the methodology and the physiological reliability of the experimental results support the suitability of this approach for clinical applications.


Assuntos
Contração Muscular , Músculo Esquelético , Algoritmos , Eletromiografia/métodos , Humanos , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Análise de Ondaletas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA