Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 26(12): 4268-4276, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27384609

RESUMO

OBJECTIVES: To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. METHODS: Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. RESULTS: The KAP (3rd quartile) in Gy cm2 for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. CONCLUSIONS: The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. KEY POINTS: • National DRLs for interventional procedures have been proposed given level of complexity • For clinical audits, the level of complexity should be taken into account. • An evaluation of the complexity levels of the procedure should be made.


Assuntos
Angiografia/métodos , Angiografia/normas , Controle de Qualidade , Radiologia Intervencionista/métodos , Radiologia Intervencionista/normas , Feminino , Humanos , Doses de Radiação , Valores de Referência , Espanha , Inquéritos e Questionários
2.
Med Phys ; 42(1): 221-31, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25563262

RESUMO

PURPOSE: This paper presents a model for dose-response curves of radiochromic films. It is based on a modified version of single-hit model to take into account the growth experienced by lithium salt of pentacosa-10,12-diynoic acid polymers after irradiation. METHODS: Polymer growth in radiochromic films is a critical phenomenon that can be properly described by means of percolation theory to provide an appropriate distribution function for polymer sizes. Resulting functional form is a power function featuring a critical exponent and two adjustable parameters. Moreover, these parameters act as scaling factors setting a natural scale for sensitometric curves where the dependence on channel sensitivity is removed. A unique reduced response curve is then obtained from all the color channels describing film behavior independently of film dosimetry system. RESULTS: Resulting functional form has been successfully tested in several sensitometric curves from different Gafchromic EBT models, providing excellent agreement with experimental data in a wide dose range up to about 40 Gy and low dose uncertainty. CONCLUSIONS: The model presented in this paper describes accurately the sensitometric curves of radiochromic films in wide dose ranges covering all typical ranges used in external radiotherapy. Resulting dose uncertainty is low enough to render a reasonably good performance in clinical applications. Due to cross-correlation, only one of the adjustable parameters is totally independent and characterizes film batches.


Assuntos
Dosimetria Fotográfica , Modelos Teóricos , Algoritmos , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...