Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Psychon Bull Rev ; 30(3): 1158-1169, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36385356

RESUMO

We investigated the effects of two types of competition, races and tournaments (as well as an individual challenge and a do-your-best condition), on two different aspects of performance: effort and strategy. In our experiment, 100 undergraduate participants completed a simple cognitive task under four experimental conditions (in a repeated-measures design) based on different types of competitions and challenges. We used the Linear Ballistic Accumulator to quantify the effects of competition on strategy and effort. The results reveal that competition produced changes in strategy rather than effort, and that trait competitiveness had minimal impact on how people responded to competition. This suggests individuals are more likely to adjust their strategy in competitions, and the uncertainty created by different competition types influences the direction of these strategy adjustments.


Assuntos
Cognição , Humanos , Incerteza
2.
Nat Commun ; 13(1): 4708, 2022 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-35953469

RESUMO

The European X-ray Free Electron Laser (XFEL) and Linac Coherent Light Source (LCLS) II are extremely intense sources of X-rays capable of generating Serial Femtosecond Crystallography (SFX) data at megahertz (MHz) repetition rates. Previous work has shown that it is possible to use consecutive X-ray pulses to collect diffraction patterns from individual crystals. Here, we exploit the MHz pulse structure of the European XFEL to obtain two complete datasets from the same lysozyme crystal, first hit and the second hit, before it exits the beam. The two datasets, separated by <1 µs, yield up to 2.1 Å resolution structures. Comparisons between the two structures reveal no indications of radiation damage or significant changes within the active site, consistent with the calculated dose estimates. This demonstrates MHz SFX can be used as a tool for tracking sub-microsecond structural changes in individual single crystals, a technique we refer to as multi-hit SFX.


Assuntos
Elétrons , Lasers , Cristalografia por Raios X , Radiografia , Raios X
3.
Rev Sci Instrum ; 93(7): 073704, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35922318

RESUMO

Improvements in x-ray optics critically depend on the measurement of their optical performance. The knowledge of wavefront aberrations, for example, can be used to improve the fabrication of optical elements or to design phase correctors to compensate for these errors. At present, the characterization of such optics is made using intense x-ray sources, such as synchrotrons. However, the limited access to these facilities can substantially slow down the development process. Improvements in the brightness of lab-based x-ray micro-sources in combination with the development of new metrology methods, particularly ptychographic x-ray speckle tracking, enable characterization of x-ray optics in the lab with a precision and sensitivity not possible before. Here, we present a laboratory setup that utilizes a commercially available x-ray source and can be used to characterize different types of x-ray optics. The setup is used in our laboratory on a routine basis to characterize multilayer Laue lenses of high numerical aperture and other optical elements. This typically includes measurements of the wavefront distortions, optimum operating photon energy, and focal length of the lens. To check the sensitivity and accuracy of this laboratory setup, we compared the results to those obtained at the synchrotron and saw no significant difference. To illustrate the feedback of measurements on performance, we demonstrated the correction of the phase errors of a particular multilayer Laue lens using a 3D printed compound refractive phase plate.

4.
IUCrJ ; 9(Pt 2): 204-214, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35371510

RESUMO

One of the outstanding analytical problems in X-ray single-particle imaging (SPI) is the classification of structural heterogeneity, which is especially difficult given the low signal-to-noise ratios of individual patterns and the fact that even identical objects can yield patterns that vary greatly when orientation is taken into consideration. Proposed here are two methods which explicitly account for this orientation-induced variation and can robustly determine the structural landscape of a sample ensemble. The first, termed common-line principal component analysis (PCA), provides a rough classification which is essentially parameter free and can be run automatically on any SPI dataset. The second method, utilizing variation auto-encoders (VAEs), can generate 3D structures of the objects at any point in the structural landscape. Both these methods are implemented in combination with the noise-tolerant expand-maximize-compress (EMC) algorithm and its utility is demonstrated by applying it to an experimental dataset from gold nanoparticles with only a few thousand photons per pattern. Both discrete structural classes and continuous deformations are recovered. These developments diverge from previous approaches of extracting reproducible subsets of patterns from a dataset and open up the possibility of moving beyond the study of homogeneous sample sets to addressing open questions on topics such as nanocrystal growth and dynamics, as well as phase transitions which have not been externally triggered.

5.
Acta Crystallogr A Found Adv ; 77(Pt 1): 19-35, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399128

RESUMO

A phasing algorithm for macromolecular crystallography is proposed that utilizes diffraction data from multiple crystal forms - crystals of the same molecule with different unit-cell packings (different unit-cell parameters or space-group symmetries). The approach is based on the method of iterated projections, starting with no initial phase information. The practicality of the method is demonstrated by simulation using known structures that exist in multiple crystal forms, assuming some information on the molecular envelope and positional relationships between the molecules in the different unit cells. With incorporation of new or existing methods for determination of these parameters, the approach has potential as a method for ab initio phasing.

6.
J Appl Crystallogr ; 53(Pt 6): 1603-1612, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33304226

RESUMO

In recent years, X-ray speckle-tracking techniques have emerged as viable tools for wavefront metrology and sample imaging applications. These methods are based on the measurement of near-field images. Thanks to their simple experimental setup, high angular sensitivity and compatibility with low-coherence sources, these methods have been actively developed for use with synchrotron and laboratory light sources. Not only do speckle-tracking techniques give the potential for high-resolution imaging, but they also provide rapid and robust characterization of aberrations of X-ray optical elements, focal spot profiles, and sample position and transmission properties. In order to realize these capabilities, software implementations are required that are equally rapid and robust. To address this need, a software suite has been developed for the ptychographic X-ray speckle-tracking technique, an X-ray speckle-based method suitable for highly divergent wavefields. The software suite is written in Python 3, with an OpenCL back end for GPU and multi-CPU core processing. It is accessible as a Python module, through the command line or through a graphical user interface, and is available as source code under Version 3 or later of the GNU General Public License.

7.
Sci Data ; 7(1): 404, 2020 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-33214568

RESUMO

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 µm x 1.7 µm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.


Assuntos
Colífagos , Lasers , Aceleradores de Partículas , Vírion , Difração de Raios X
8.
Acta Crystallogr A Found Adv ; 76(Pt 6): 664-676, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33125350

RESUMO

The deterioration of both the signal-to-noise ratio and the spatial resolution in the electron-density distribution reconstructed from diffraction intensities collected at different orientations of a sample is analysed theoretically with respect to the radiation damage to the sample and the variations in the X-ray intensities illuminating different copies of the sample. The simple analytical expressions and numerical estimates obtained for models of radiation damage and incident X-ray pulses may be helpful in planning X-ray free-electron laser (XFEL) imaging experiments and in analysis of experimental data. This approach to the analysis of partially coherent X-ray imaging configurations can potentially be used for analysis of other forms of imaging where the temporal behaviour of the sample and the incident intensity during exposure may affect the inverse problem of sample reconstruction.

9.
Nat Commun ; 11(1): 4511, 2020 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-32908128

RESUMO

Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported.


Assuntos
Cristalografia/instrumentação , Elétrons , Dispositivos Lab-On-A-Chip , Lasers , Aldeído Liases/ultraestrutura , Proteínas de Escherichia coli/ultraestrutura , Hidrodinâmica
10.
J Appl Crystallogr ; 53(Pt 4): 927-936, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32788900

RESUMO

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

11.
J Appl Crystallogr ; 53(Pt 3): 760-780, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32684891

RESUMO

A method is presented for the measurement of the phase gradient of a wavefront by tracking the relative motion of speckles in projection holograms as a sample is scanned across the wavefront. By removing the need to obtain an undistorted reference image of the sample, this method is suitable for the metrology of highly divergent wavefields. Such wavefields allow for large magnification factors that, according to current imaging capabilities, will allow for nanoradian angular sensitivity and nanoscale sample projection imaging. Both the reconstruction algorithm and the imaging geometry are nearly identical to that of ptychography, except that the sample is placed downstream of the beam focus and that no coherent propagation is explicitly accounted for. Like other X-ray speckle tracking methods, it is robust to low-coherence X-ray sources, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology. A modified form of the speckle tracking approximation is also presented, based on a second-order local expansion of the Fresnel integral. This result extends the validity of the speckle tracking approximation and may be useful for similar approaches in the field.

12.
J Nucl Med ; 61(11): 1678-1683, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32245898

RESUMO

A data-driven method for respiratory gating in PET has recently been commercially developed. We sought to compare the performance of the algorithm with an external, device-based system for oncologic 18F-FDG PET/CT imaging. Methods: In total, 144 whole-body 18F-FDG PET/CT examinations were acquired, with a respiratory gating waveform recorded by an external, device-based respiratory gating system. In each examination, 2 of the bed positions covering the liver and lung bases were acquired with a duration of 6 min. Quiescent-period gating retaining approximately 50% of coincidences was then able to produce images with an effective duration of 3 min for these 2 bed positions, matching the other bed positions. For each examination, 4 reconstructions were performed and compared: data-driven gating (DDG) (we use the term DDG-retro to distinguish that we did not use the real-time R-threshold-based application of DDG that is available within the manufacturer's product), external device-based gating (real-time position management (RPM)-gated), no gating but using only the first 3 min of data (ungated-matched), and no gating retaining all coincidences (ungated-full). Lesions in the images were quantified and image quality scored by a radiologist who was masked to the method of data processing. Results: Compared with the other reconstruction options, DDG-retro increased the SUVmax and decreased the threshold-defined lesion volume. Compared with RPM-gated, DDG-retro gave an average increase in SUVmax of 0.66 ± 0.1 g/mL (n = 87, P < 0.0005). Although the results from the masked image evaluation were most commonly equivalent, DDG-retro was preferred over RPM-gated in 13% of examinations, whereas the opposite occurred in just 2% of examinations. This was a significant preference for DDG-retro (P = 0.008, n = 121). Liver lesions were identified in 23 examinations. Considering this subset of data, DDG-retro was ranked superior to ungated-full in 6 of 23 (26%) cases. Gated reconstruction using the external device failed in 16% of examinations, whereas DDG-retro always provided a clinically acceptable image. Conclusion: In this clinical evaluation, DDG-retro provided performance superior to that of the external device-based system. For most examinations the performance was equivalent, but DDG-retro had superior performance in 13% of examinations, leading to a significant preference overall.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Técnicas de Imagem de Sincronização Respiratória/métodos , Algoritmos , Humanos
13.
Opt Express ; 27(26): 37816-37833, 2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-31878556

RESUMO

An outstanding question in X-ray single particle imaging experiments has been the feasibility of imaging sub 10-nm-sized biomolecules under realistic experimental conditions where very few photons are expected to be measured in a single snapshot and instrument background may be significant relative to particle scattering. While analyses of simulated data have shown that the determination of an average image should be feasible using Bayesian methods such as the EMC algorithm, this has yet to be demonstrated using experimental data containing realistic non-isotropic instrument background, sample variability and other experimental factors. In this work, we show that the orientation and phase retrieval steps work at photon counts diluted to the signal levels one expects from smaller molecules or with weaker pulses, using data from experimental measurements of 60-nm PR772 viruses. Even when the signal is reduced to a fraction as little as 1/256, the virus electron density determined using ab initio phasing is of almost the same quality as the high-signal data. However, we are still limited by the total number of patterns collected, which may soon be mitigated by the advent of high repetition-rate sources like the European XFEL and LCLS-II.

14.
Environ Res ; 176: 108507, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31203050

RESUMO

During the last few years, there has been an alarming increase in the amount of nickel (Ni) being released into the environment, primarily due to its use in the production of stainless steel but also from other sources such as batteries manufacturing and consequent disposal. The established biotic ligand models provide precise estimates for Ni bioavailability, in contrast, studies describing the mechanisms underpinning toxicological effect of Ni are scarce. This study exploits RNA-seq to determine the transcriptomic responses of isopods using Porcellionides pruinosus as an example of a terrestrial metal-resistant woodlouse. Furthermore, the recently proposed model for Ni adverse outcome pathways (Ni-AOP) presents an unprecedented opportunity to fit isopod responses to Ni toxicity and define Porcellionides pruinosus as a metalomic model. Prior to this study, P. pruinosus represented an important environmental sentinel, though lacking genetic/omic data. The reference transcriptome generated here thus represents a major advance and a novel resource. A detailed annotation of the transcripts obtained is presented together with the homology to genes/gene products from Metazoan and Arthropoda phylum, Gene Ontology (GO) classification, clusters of orthologous groups (COG) and assignment to KEGG metabolic pathways. The differential gene expression comparison was determined in response to nickel (Ni) exposure and used to derive the enriched pathways and processes. It revealed a significant impact on ion trafficking and storage, oxidative stress, neurotoxicity, reproduction impairment, genetics and epigenetics. Many of the processes observed support the current Ni-AOP although the data highlights that the current model can be improved by including epigenetic endpoints, which represents key chronic risks under a scenario of Ni toxicity.


Assuntos
Poluentes Ambientais , Isópodes , Níquel , Animais , Poluentes Ambientais/farmacocinética , Poluentes Ambientais/toxicidade , Níquel/farmacocinética , Níquel/toxicidade , Estresse Oxidativo , Reprodução , Transcriptoma
15.
Opt Express ; 27(5): 7120-7138, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30876283

RESUMO

X-ray microscopy at photon energies above 15 keV is very attractive for the investigation of atomic and nanoscale properties of technologically relevant structural and bio materials. This method is limited by the quality of X-ray optics. Multilayer Laue lenses (MLLs) have the potential to make a major impact in this field because, as compared to other X-ray optics, they become more efficient and effective with increasing photon energy. In this work, MLLs were utilized with hard X-rays at photon energies up to 34.5 keV. The design, fabrication, and performance of these lenses are presented, and their application in several imaging configurations is described. In particular, two "full field" modes of imaging were explored, which provide various contrast modalities that are useful for materials characterisation. These include point projection imaging (or Gabor holography) for phase contrast imaging and direct imaging with both bright-field and dark-field illumination. With high-efficiency MLLs, such modes offer rapid data collection as compared with scanning methods as well as a large field of views.

16.
Nucl Med Commun ; 40(4): 349-352, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30672871

RESUMO

OBJECTIVES: The aim of the study was to identify a threshold value of the estimated glomerular filtration rate (eGFR) that would predict a measured glomerular filtration rate (mGFR) of ≤25 ml/min/1.73 m. This is to guide use of the new British Nuclear Medicine Society guidelines, which specifies a 24 h sample for patients with a GFR of ≤25 ml/min/1.73 m, when using the single-sample (SS) method. PATIENTS AND METHODS: Data from 1956 patient studies were used to calculate values for the GFR using the slope intercept (SI) method and SS , which was taken 210 min after injection. A sub-data set of 241 patients was taken with patients having an mGFR of ≤80 ml/min/1.73 m by the SS or SI method and an eGFR value within 28 days of the mGFR. The Modification of Diet in Renal Disease equation was used to calculate the eGFR. Receiver operator characteristic curves comparing the sensitivity and specificity of using the eGFR to predict values of the mGFR were used to find a threshold value for the eGFR. RESULTS: There is a large variation in the accuracy of using the eGFR to predict the mGFR value. The mean difference for the SI method is -2%, with an absolute percentage difference of 22% and a range of -121 to 63%. The SS method has a mean percentage difference of -1%, absolute percentage difference of 23% and a range of -153 to 86%.From the receiver operator characteristic graphs, an eGFR value of 40 ml/min/1.73 m was chosen to maximise the sensitivity of the eGFR threshold value used to predict an mGFR value of ≤25 ml/min/1.73 m. CONCLUSION: The eGFR value has a high error when used for predicting the mGFR. Therefore, the study recommends that an eGFR threshold value of ≤40 ml/min/1.73 m is used to predict mGFRs of ≤25 ml/min/1.73 m in order to optimise the likelihood of identifying all such patients.


Assuntos
Creatinina/sangue , Taxa de Filtração Glomerular , Testes de Função Renal/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
17.
EJNMMI Res ; 9(1): 1, 2019 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-30607651

RESUMO

BACKGROUND: We aimed to evaluate the clinical robustness of a commercially developed data-driven respiratory gating algorithm based on principal component analysis, for use in routine PET imaging. METHODS: One hundred fifty-seven adult FDG PET examinations comprising a total of 1149 acquired bed positions were used for the assessment. These data are representative of FDG scans currently performed at our institution. Data were acquired for 4 min/bed position (3 min/bed for legs). The data-driven gating (DDG) algorithm was applied to each bed position, including those where minimal respiratory motion was expected. The algorithm provided a signal-to-noise measure of respiratory-like frequencies within the data, denoted as R. Qualitative evaluation was performed by visual examination of the waveforms, with each waveform scored on a 3-point scale by two readers and then averaged (score S of 0 = no respiratory signal, 1 = some respiratory-like signal but indeterminate, 2 = acceptable signal considered to be respiratory). Images were reconstructed using quiescent period gating and compared with non-gated images reconstructed with a matched number of coincidences. If present, the SUVmax of a well-defined lesion in the thorax or abdomen was measured and compared between the two reconstructions. RESULTS: There was a strong (r = 0.86) and significant correlation between R and scores S. Eighty-six percent of waveforms with R ≥ 15 were scored as acceptable for respiratory gating. On average, there were 1.2 bed positions per patient examination with R ≥ 15. Waveforms with high R and S were found to originate from bed positions corresponding to the thorax and abdomen: 90% of waveforms with R ≥ 15 had bed centres in the range 5.6 cm superior to 27 cm inferior from the dome of the liver. For regions where respiratory motion was expected to be minimal, R tended to be < 6 and S tended to be 0. The use of DDG significantly increased the SUVmax of focal lesions, by an average of 11% when considering lesions in bed positions with R ≥ 15. CONCLUSIONS: The majority of waveforms with high R corresponded to the part of the patient where respiratory motion was expected. The waveforms were deemed suitable for respiratory gating when assessed visually, and when used were found to increase SUVmax in focal lesions.

18.
Acta Crystallogr A Found Adv ; 75(Pt 1): 25-40, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30575581

RESUMO

To date X-ray protein crystallography is the most successful technique available for the determination of high-resolution 3D structures of biological molecules and their complexes. In X-ray protein crystallography the structure of a protein is refined against the set of observed Bragg reflections from a protein crystal. The resolution of the refined protein structure is limited by the highest angle at which Bragg reflections can be observed. In addition, the Bragg reflections alone are typically insufficient (by a factor of two) to determine the structure ab initio, and so prior information is required. Crystals formed from an imperfect packing of the protein molecules may also exhibit continuous diffraction between and beyond these Bragg reflections. When this is due to random displacements of the molecules from each crystal lattice site, the continuous diffraction provides the necessary information to determine the protein structure without prior knowledge, to a resolution that is not limited by the angular extent of the observed Bragg reflections but instead by that of the diffraction as a whole. This article presents an iterative projection algorithm that simultaneously uses the continuous diffraction as well as the Bragg reflections for the determination of protein structures. The viability of this method is demonstrated on simulated crystal diffraction.


Assuntos
Algoritmos , Cristalografia por Raios X/métodos , Proteínas/química , Modelos Químicos , Modelos Moleculares , Conformação Proteica
19.
IUCrJ ; 5(Pt 6): 727-736, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30443357

RESUMO

The analysis of a single-particle imaging (SPI) experiment performed at the AMO beamline at LCLS as part of the SPI initiative is presented here. A workflow for the three-dimensional virus reconstruction of the PR772 bacteriophage from measured single-particle data is developed. It consists of several well defined steps including single-hit diffraction data classification, refined filtering of the classified data, reconstruction of three-dimensional scattered intensity from the experimental diffraction patterns by orientation determination and a final three-dimensional reconstruction of the virus electron density without symmetry constraints. The analysis developed here revealed and quantified nanoscale features of the PR772 virus measured in this experiment, with the obtained resolution better than 10 nm, with a clear indication that the structure was compressed in one direction and, as such, deviates from ideal icosahedral symmetry.

20.
IUCrJ ; 5(Pt 5): 574-584, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30224961

RESUMO

Liquid microjets are a common means of delivering protein crystals to the focus of X-ray free-electron lasers (FELs) for serial femtosecond crystallography measurements. The high X-ray intensity in the focus initiates an explosion of the microjet and sample. With the advent of X-ray FELs with megahertz rates, the typical velocities of these jets must be increased significantly in order to replenish the damaged material in time for the subsequent measurement with the next X-ray pulse. This work reports the results of a megahertz serial diffraction experiment at the FLASH FEL facility using 4.3 nm radiation. The operation of gas-dynamic nozzles that produce liquid microjets with velocities greater than 80 m s-1 was demonstrated. Furthermore, this article provides optical images of X-ray-induced explosions together with Bragg diffraction from protein microcrystals exposed to trains of X-ray pulses repeating at rates of up to 4.5 MHz. The results indicate the feasibility for megahertz serial crystallography measurements with hard X-rays and give guidance for the design of such experiments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...