Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Pediatr Pharmacol Ther ; 27(3): 284-291, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35350163

RESUMO

OBJECTIVE: Inhaled nitric oxide (iNO) is an effective but expensive treatment of pulmonary hypertension in newborns, with limited data regarding weaning. Our institution implemented a multidisciplinary iNO weaning protocol and stewardship to reduce inappropriate use of iNO. The objective of this study was to evaluate our institutional iNO usage before and after implementation. METHODS: Single-center study comparing a retrospective control group to a prospective cohort after implementation of an iNO weaning protocol. All infants in the neonatal intensive care unit (NICU) who received iNO during the study timeframe were included. The primary outcome was duration of iNO per course. RESULTS: A total of 47 courses of iNO occurred during the pre-protocol timeframe compared with 37 courses in the post-protocol timeframe. Median iNO usage per course was 149 hours (IQR, 63-243) in the pre-protocol group versus 59 hours (IQR, 37-122) in the post-protocol group (p = 0.008). Length of stay was significantly longer in the pre-protocol group (p = 0.02), likely related to significantly longer ventilator days in the pre-protocol group (p = 0.02). Compliance with initiation of weaning when recommended per the protocol was 72%, and the incidence of successful weaning was 74%. CONCLUSIONS: The implementation of an iNO weaning protocol in the NICU significantly decreased iNO usage by approximately 60% with no notable negative effects.

2.
J Patient Saf ; 16(2): 117-122, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32175970

RESUMO

OBJECTIVES: Predictions estimate supplies of filtering facepiece respirators (FFRs) would be limited in the event of a severe influenza pandemic. Ultraviolet decontamination and reuse (UVDR) is a potential approach to mitigate an FFR shortage. A field study sought to understand healthcare workers' perspectives and potential logistics issues related to implementation of UVDR methods for FFRs in hospitals. METHODS: Data were collected at three hospitals using a structured guide to conduct 19 individual interviews, 103 focus group interviews, and 285 individual surveys. Data were then evaluated using thematic analysis to reveal key themes. RESULTS: Data revealed noteworthy variation in FFR use across the sample, along with preferences and requirements for the use of UVDR, unit design, and FFR reuse. Based on a scale of 1 (low) to 10 (high), the mean perception of safety in a high mortality pandemic wearing no FFR was 1.25 of 10, wearing an FFR for an extended period without decontamination was 4.20 of 10, and using UVDR was 7.72 of 10. CONCLUSIONS: In addition to technical design and development, preparation and training will be essential to successful implementation of a UVDR program. Ultraviolet decontamination and reuse program design and implementation must account for actual clinical practice, compliance with regulations, and practical financial considerations to be successfully adopted so that it can mitigate potential FFR shortages in a pandemic.


Assuntos
Descontaminação/métodos , Influenza Humana/terapia , Terapia Ultravioleta/métodos , Ventiladores Mecânicos/normas , Hospitais , Humanos , Influenza Humana/epidemiologia , Pandemias , Inquéritos e Questionários
3.
Can J Respir Ther ; 56: 7-10, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32181326

RESUMO

INTRODUCTION: Oscillatory positive expiratory pressure (OPEP) devices facilitate secretion clearance by generating positive end expiratory pressure. However, different device designs may produce different levels of expiratory pressure with the same expiratory flow rate. We bench tested four devices to determine the relationship between expiratory flow and expiratory pressure in each. METHODS: A bench model was created to test the gas flow rates required by different OPEP devices to generate target expiratory pressure. Four different devices were tested: Acapella® (DH Green, Smiths Medical), AerobiKa® (Monaghan Medical Corporation), VibraPEP® (Curaplex), and vPEP™ (D R Burton Healthcare). Each OPEP device was tested to determine the expiratory flow needed to generate expiratory pressure thresholds considered appropriate for OPEP therapy. RESULTS: The expiratory flow required to generate the same expiratory pressure thresholds varied considerably among devices. Valved OPEP devices such as the VibraPEP required less flow than mechanical devices such as the vPEP, Aerobika, and Acapella. DISCUSSION: In this bench test of OPEP devices, we found considerable variability in expiratory flow requirements needed to generate an expiratory pressure of >10 cm H2O. Our finding suggests that smaller patients or those with limited expiratory airflow due to diseases such as COPD, obesity, chronic congestive heart failure, and restrictive lung disease may have better results when matched to OPEP devices requiring less expiratory airflow.

4.
Respir Care ; 60(9): e161-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26106204

RESUMO

Asthma and bronchiolitis are episodic obstructive pulmonary diseases characterized by bronchoconstriction, airway wall inflammation, increased mucus production, and air-flow obstruction. We present the cases of 5 infants treated for acute bronchiolitis with respiratory distress using a combination of high-flow nasal cannula oxygen (HFNC) and an Aerogen nebulizer to deliver aerosolized ß-agonist therapy. In all infants, we found that HFNC resulted in a greater heart rate increase than delivery via a facemask. We also found that patients tolerated inhaled therapy better with HFNC than a facemask.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Bronquiolite/terapia , Oxigenoterapia/instrumentação , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Terapia de Salvação/métodos , Catéteres , Feminino , Humanos , Lactente , Masculino , Sprays Nasais , Nebulizadores e Vaporizadores
5.
Respir Care ; 59(11): e166-70, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25118308

RESUMO

Heliox, a helium-oxygen gas mixture, has been used for many decades to treat obstructive pulmonary disease. The lower density and higher viscosity of heliox relative to nitrogen-oxygen mixtures can significantly reduce airway resistance when an anatomic upper air-flow obstruction is present and gas flow is turbulent. Clinically, heliox can decrease airway resistance in acute asthma in adults and children and in COPD. Heliox may also enhance the bronchodilating effects of ß-agonist administration for acute asthma. Respiratory syndromes caused by coronavirus infections in humans range in severity from the common cold to severe acute respiratory syndrome associated with human coronavirus OC43 and other viral strains. In infants, coronavirus infection can cause bronchitis, bronchiolitis, and pneumonia in variable combinations and can produce enough air-flow obstruction to cause respiratory failure. We describe a case of coronavirus OC43 infection in an infant with severe acute respiratory distress treated with heliox inhalation to avoid intubation.


Assuntos
Obstrução das Vias Respiratórias/tratamento farmacológico , Bronquiolite Viral/tratamento farmacológico , Infecções por Coronavirus/tratamento farmacológico , Coronavirus/imunologia , Intubação/métodos , Administração por Inalação , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/etiologia , Anticorpos Antivirais/análise , Bronquiolite Viral/complicações , Bronquiolite Viral/virologia , Infecções por Coronavirus/complicações , Infecções por Coronavirus/virologia , Hélio , Humanos , Hipóxia/fisiopatologia , Lactente , Masculino , Nariz , Oxigênio
6.
J Clin Anesth ; 17(1): 8-15, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15721723

RESUMO

STUDY OBJECTIVE: To compare the effect of inspiratory time and lung compliance on tidal volume (Vt) delivery in anesthesia and intensive care unit (ICU) ventilators operating in pressure control mode. SETTING: Respiratory research laboratory of a tertiary care medical center. DESIGN: Two anesthesia ventilators with pressure control capability (Narkomed 6000, Drager Medical, Inc, Telford, Pa, and the Datex-Ohmeda Aestiva 5, Datex-Ohmeda, Inc, Madison, Wis) and one critical care ventilator (Puritan Bennett 7200, Puritan-Bennett, Pleasanton, Calif) were studied under varying inspiratory time and lung compliance conditions using a mechanical lung model. INTERVENTION: Each ventilator was set to pressure control mode at a fixed inspiratory/expiratory (I/E) ratio. The respiratory rate (RR) was varied between 6 and 28 breaths per minute. Lung compliance and inspiratory time settings were set to simulate clinical conditions known to affect anesthesia ventilator performance. MEASUREMENTS: Inspiratory flow, Vts, and peak airway pressures were measured using the on-board monitor for each ventilator, and confirmed with the Bicore CP-100 pulmonary mechanics monitor (Bicore Monitoring Systems, Inc, Irvine, Calif). To assess differences in inspiratory flow between ventilators, airway pressures were continuously monitored during inspiration. MAIN RESULTS: Increasing RRs caused delivered Vts to decrease for all ventilators. However, decreases in Vts were significantly larger for anesthesia than for ICU ventilators. At a lung compliance of 0.02 L/cm H(2)O and set Vt of 700 mL, Vt delivery for the Puritan Bennett 7200 ventilator remained at 88% of baseline, but decreased to 76% for the Aestiva 5 when RRs were increased from 6 to 28 breaths per minute (P < .0025). Airway pressure tracings demonstrated a slower increase in inspiratory airway pressure for the Aestiva 5 than for the other ventilators. CONCLUSION: Differences in inspiratory flow delivery between ICU and anesthesia ventilators can cause differences in Vt delivery when the pressure control mode is used at high RRs. These differences can significantly impact the perioperative care of critically ill patients requiring ventilatory support.


Assuntos
Anestesia , Cuidados Críticos , Respiração Artificial , Mecânica Respiratória/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Ventiladores Mecânicos , Pressão do Ar , Humanos , Modelos Estatísticos , Análise de Regressão
7.
J Pediatr ; 143(5): 640-3, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14615737

RESUMO

OBJECTIVE: To study whether nebulized nitroprusside (neb-NP) improves oxygenation in term infants with hypoxic respiratory failure (HRF). STUDY DESIGN: We studied 22 newborn term infants (gestational age, 39.7+/-0.4 weeks [mean+/-SEM]; birth weight, 3.6+/-0.1 kg) with hypoxia (Pao2<100 mm Hg) during mechanical ventilation (Fio2=1.0). Sodium nitroprusside (5 mg followed by 25 mg) was nebulized into the inspiratory arm of the ventilator circuit. Vital signs and arterial blood gas values were recorded after 20 minutes at each dose and before and after initiation of inhaled nitric oxide (iNO). RESULTS: Pao2 increased significantly with 5 mg neb-NP (from 64.6+/-5.6 to 90.1+/-15.3 mm Hg, P=.04) and with 25 mg neb-NP (113.2+/-20.4 mm Hg, P=.009). Differences between mean Pao2 at 5 mg versus 25 mg neb-NP were also statistically significant (P=.03). When comparing the effect of neb-NP to iNO, the treatment-induced increases in Pao2 were similar (52.1+/-18.7 vs 62.2+/-18.2 mm Hg, respectively, P=not significant). CONCLUSIONS: Neb-NP causes a dose-dependent increase in oxygenation in term infants with HRF, similar in magnitude to iNO* Neb-NP may be beneficial in infants with HRF when iNO is not readily available.


Assuntos
Frequência Cardíaca/fisiologia , Hipóxia/complicações , Nitroprussiato/uso terapêutico , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Vasodilatadores/uso terapêutico , Administração por Inalação , Encéfalo/metabolismo , Relação Dose-Resposta a Droga , Feminino , Hemodinâmica/fisiologia , Humanos , Hipóxia/diagnóstico , Hipóxia/metabolismo , Lactente , Pulmão/fisiopatologia , Masculino , Óxido Nítrico/administração & dosagem , Nitroprussiato/administração & dosagem , Oximetria , Oxigênio/metabolismo , Estudos Prospectivos , Insuficiência Respiratória/fisiopatologia , Vasodilatadores/administração & dosagem
8.
Crit Care Med ; 30(11): 2560-5, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12441770

RESUMO

OBJECTIVE: To test the hypothesis that nebulized nitroprusside and inhaled nitric oxide would not differ in producing selective pulmonary vasodilation during hypoxia-induced pulmonary hypertension in piglets. SETTING: University laboratory. SUBJECTS: Five piglets. INTERVENTIONS: Piglets (n = 5) were anesthetized and instrumented to monitor systemic arterial pressure, pulmonary artery pressure, and cardiac output continuously. Hypoxia was induced (DeltaFio2 from 0.5 to 0.08), and either nebulized nitroprusside (5 mg/mL at 4 L/min flow; total dose 25 mg) or inhaled nitric oxide (20 ppm) was introduced into the ventilator circuit for 15 mins. Normoxia was then restored, and a repeat cycle of hypoxia followed by the alternate vasodilator treatment was initiated. MEASUREMENTS AND MAIN RESULTS: Hypoxia significantly reduced Pao2 (from 206 to 30 torr) and elevated pulmonary artery pressure (from 18 to 33 torr) while not significantly affecting systemic arterial pressure or cardiac output. During hypoxia, inhaled nitric oxide reduced pulmonary artery pressure from 33 to 21 torr (p <.01), whereas systemic arterial pressure and cardiac output were unchanged. During hypoxia, nebulized nitroprusside also reduced pulmonary artery pressure from 33 to 23 mm Hg (p <.01; p = nonsignificant vs. inhaled nitric oxide), whereas systemic arterial pressure and cardiac output again remained constant. The time course of the reduction in pulmonary artery pressure during inhaled nitric oxide was roughly ten-fold more rapid (<5 secs) than during nebulized nitroprusside ( approximately 1 min). Neither inhaled nitric oxide nor nebulized nitroprusside altered pH, Pao2, or Paco2. CONCLUSION: Both inhaled nitric oxide and nebulized nitroprusside produced prompt, significant, selective reduction of pulmonary artery pressure and pulmonary vascular resistance in piglets with hypoxia-induced pulmonary hypertension, without apparent effects on systemic hemodynamics or pulmonary gas exchange. The equivalence of the two effects in this animal model suggests that cautious extrapolation of the use of nebulized nitroprusside as a convenient bridge to inhaled nitric oxide in selected clinical contexts for human infants may be warranted.


Assuntos
Hemodinâmica/efeitos dos fármacos , Hipertensão Pulmonar/tratamento farmacológico , Óxido Nítrico/uso terapêutico , Nitroprussiato/uso terapêutico , Vasodilatadores/uso terapêutico , Análise de Variância , Animais , Animais Recém-Nascidos , Humanos , Hipertensão Pulmonar/etiologia , Hipóxia/complicações , Recém-Nascido , Óxido Nítrico/farmacologia , Nitroprussiato/farmacologia , Síndrome da Persistência do Padrão de Circulação Fetal/tratamento farmacológico , Circulação Pulmonar/efeitos dos fármacos , Troca Gasosa Pulmonar/efeitos dos fármacos , Distribuição Aleatória , Suínos , Vasodilatadores/farmacologia
9.
Anesth Analg ; 95(1): 192-7, table of contents, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12088967

RESUMO

UNLABELLED: A recognized hazard of prolonged endotracheal intubation is progressive airway occlusion resulting from deposition of secretions on the inner surface of the endotracheal tube (ETT). When volume-controlled ventilation is used, progressive ETT occlusion may be detected by monitoring the difference between peak and plateau airway pressures. In pressure-controlled modes, however, inspiratory airway pressures are preset and thus cannot act as a warning indicator. Instead, changes in delivered tidal volumes may aid the diagnosis of ETT occlusion. To determine whether tidal volume monitoring effectively detects progressive ETT occlusion, we mathematically modeled the response of a ventilator operating in pressure-controlled mode to increasing airway resistance. To corroborate our model, we then bench-tested the Siemens 300 and Puritan-Bennett 7200 ventilators by using a test lung and a series of ETTs ranging in size from 9.0 to 3.5 mm inner diameter to simulate progressive occlusion. We found that when pressure-controlled mode was used, progressive ETT occlusion did not reduce delivered tidal volumes until occlusion was nearly complete. We conclude that prolonged use of pressure-controlled mode may allow significant ETT obstruction to build up undetected, risking complete ETT occlusion and complicating the perioperative care of patients ventilated with this mode. IMPLICATIONS: Although increasing airway pressures during volume-controlled ventilation allow early recognition of endotracheal tube (ETT) obstruction, airway pressures with pressure-controlled ventilation are fixed. We found during tests of two intensive care unit ventilators that although ETT obstruction reduces delivered tidal volumes during pressure-controlled ventilation, reductions do not occur until occlusion is advanced.


Assuntos
Intubação Intratraqueal , Volume de Ventilação Pulmonar/fisiologia , Algoritmos , Cuidados Críticos , Humanos , Modelos Biológicos , Respiração Artificial , Testes de Função Respiratória , Ventiladores Mecânicos
10.
Am J Respir Crit Care Med ; 165(9): 1317-21, 2002 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-11991886

RESUMO

Heliox improves lung deposition of inhaled particles when compared with air or oxygen inhalation. We studied the spirometric effects of albuterol nebulized with heliox during emergency room visits for asthma exacerbations. Forty-five patients were randomized to receive albuterol nebulized with oxygen (control) versus heliox (n = 22 control and 23 heliox subjects). At baseline, demographics, outpatient asthma medications, vital signs, oxygen saturation, and forced expiratory volume in one second were not different between the two groups. Three consecutive albuterol treatments were given to each group. The heliox group had a significantly higher heart rate after albuterol nebulization compared with the control group. Following albuterol Treatment 1, the median change in forced expiratory volume in one second was 14.6% in the control group and 32.4% in the heliox group (p = 0.007). After Treatment 2, the results were 22.7% versus 51.5%, respectively (p = 0.007). After Treatment 3, the results were 26.6% versus 65.1%, respectively (p = 0.016). We conclude that during acute asthma exacerbations, albuterol nebulized with heliox leads to a more significant improvement in spirometry when compared with albuterol nebulized with oxygen. This is likely due to the low-density gas improving albuterol deposition in the distal airways.


Assuntos
Albuterol/administração & dosagem , Asma/tratamento farmacológico , Hélio/administração & dosagem , Oxigênio/administração & dosagem , Administração por Inalação , Adulto , Albuterol/farmacologia , Combinação de Medicamentos , Emergências , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Hélio/farmacologia , Humanos , Masculino , Nebulizadores e Vaporizadores , Oxigênio/farmacologia , Espirometria , Estatísticas não Paramétricas
11.
Respir Care ; 47(1): 61-8, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11749688

RESUMO

INTRODUCTION: The unique electromagnetic environment of the magnetic resonance imaging (MRI) scanner presents particular problems for critically ill patients requiring mechanical ventilation during MRI. Most currently available MRI-compatible ventilators are limited in scope and function and thus may not be suitable for patients requiring high peak inspiratory pressure or flow. METHODS: To determine whether a standard critical care ventilator could be used under MRI conditions, we modified a Siemens Servo 900C by replacing the standard oxygen blender with an MRI-compatible blender. We then calibrated the ventilator and tested it on a mechanical lung during active MRI scanning at magnetic fields up to 1.5 tesla. After verifying adequate function, we used the ventilator to support 21 critically ill patients requiring mechanical ventilation during MRI. RESULTS: In all cases we found no alterations in ventilator performance resulting from the electromagnetic interference typical of an MRI scan. We also found no abnormalities in the alarm systems for fraction of inspired oxygen, high inspiratory pressure, or minute volume. Finally, we found no degradation of MRI image quality resulting from ventilator operation during test scanning. CONCLUSIONS: We conclude that with minor modifications the Siemens 900C ventilator can safely ventilate critically ill patients during MRI.


Assuntos
Cuidados Críticos , Imageamento por Ressonância Magnética , Ventiladores Mecânicos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...