Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Heart Rhythm ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759918

RESUMO

BACKGROUND: Novel diamond-embedded catheter enables precise temperature-controlled ablation. However, the effects of contact angle on lesion formation of this catheter are poorly understood. OBJECTIVE: This study evaluated lesion formation using the temperature-controlled ablation catheter embedded with diamond at different angles in a porcine experimental model. METHODS: We used freshly sacrificed porcine hearts, and radiofrequency catheter ablation was performed at 50 watts for 15 s at an upper-temperature setting of 60°C. The contact force (5, 10, and 30 g) and catheter contact angles (30°, 45°, and 90°) were changed in each set (n = 13 each). The surface width, maximum lesion width, lesion depth, surface area, distance from the distal edge to the widest area, and impedance drop were evaluated. RESULTS: The surface width and maximum lesion width were longer at 30° than at 90° (p<0.05). There were no significant differences in the lesion depth by catheter angle except at 30 g. The surface area was larger at 30° than at 90° (p<0.05). The distance from the distal edge to the widest area was longer at 30° than at 90° (p<0.05). There were no significant differences in the impedance drop according to the catheter angle. CONCLUSION: With the diamond-embedded temperature-controlled ablation catheters, the lesion width increased at a shallower contact angle, whereas the lesion depth did not. The surface area also increased at a shallower contact angle. This catheter created a large ablation lesion on the proximal side of the catheter, which looked like a "Honey pot."

2.
J Arrhythm ; 40(2): 349-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586843

RESUMO

Objective: Postoperative pain is a major issue with subcutaneous implantable cardioverter defibrillators (S-ICD). In 2020, we introduced intravenous patient-controlled analgesia (IV-PCA) in addition to the conventional, request-based analgesia for postoperative pain control in S-ICD. To determine the effect and safety, we quantitatively assessed the effect of IV-PCA after S-ICD surgery over conventional methods. Methods: During the study period, a total of 113 consecutive patients (age, 50.1 ± 15.5 years: males, 101) underwent a de novo S-ICD implantation under general anesthesia. While the postoperative pain was addressed with either request-based analgesia (by nonsteroid anti-inflammatory drugs, N = 68, dubbed as "PCA absent") or fentanyl-based IV-PCA in addition to the standard care (N = 45, dubbed as "PCA present"). The degree of postoperative pain from immediately after surgery to 1 week were retrospectively investigated by the numerical rating scale (NRS) divided into four groups at rest and during activity (0: no pain, 1-3: mild pain, 4-6: moderate pain, 7-10: severe pain). Results: Although IV-PCA was removed on Day 1, it was associated with continued better pain control compared to PCA absent group. At rest, the proportion of patients expressing pain (mild or more) was significantly lower in the PCA present group from Day 0 to Day 4. In contrast to at rest, a better pain control continued through the entire study period of 7 days. No serious adverse events were observed. A few patients experienced nausea in both groups and the inter-group difference was not found significant. Conclusion: IV-PCA suppresses postoperative pain in S-ICD without major safety concerns.

4.
J Arrhythm ; 40(1): 83-89, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333410

RESUMO

Background: The role of the pulmonary veins (PVs) as triggers in atrial fibrillation (AF) is well-known; however, their detailed electrophysiological properties have not been thoroughly examined. Objective: This study aimed to investigate the electrophysiological properties of the PVs between paroxysmal AF (pAF) and persistent AF (perAF). Methods: Prior to catheter ablation in patients with pAF (n = 51) and perAF (n = 41), a voltage map of the left atrium and PVs was created under sinus rhythm, and the area of the myocardial sleeves in the PVs and their electrophysiological characteristics, including the pacing threshold and effective refractory period (ERP), were compared between the two groups. Results: Compared with perAF, the myocardial sleeves of PVs for pAF were significantly larger for all PVs. The ERP for perAF was significantly shorter than that for pAF for all PVs. The pacing threshold for perAF was significantly higher than that for pAF for the right and left superior PVs. Conclusion: In patients with perAF, a decrease in the normal myocardial sleeves and a shortening of the ERP were observed for all PVs. Those changes in the electrophysiological properties of the PVs might be related to the persistence of AF.

5.
J Arrhythm ; 40(1): 131-142, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333409

RESUMO

Background: This study aimed to establish a systematic method for diagnosing atrioventricular nodal reentrant tachycardia (AVNRT) with a bystander concealed nodoventricular pathway (cNVP). Methods: We analyzed 13 cases of AVNRT with a bystander cNVP, 11 connected to the slow pathway (cNVP-SP) and two to the fast pathway (cNVP-FP), along with two cases of cNVP-related orthodromic reciprocating tachycardia (ORT). Results: The diagnostic process was summarized in three steps. Step 1 was identification of the presence of an accessory pathway by resetting the tachycardia with delay (n = 9) and termination without atrial capture (n = 4) immediately after delivery of a His-refractory premature ventricular contraction (PVC). Step 2 was exclusion of ORT by atrio-His block during the tachycardia (n = 4), disappearance of the reset phenomenon after the early PVC (n = 7), or dissociation of His from the tachycardia during ventricular overdrive pacing (n = 1). Moreover, tachycardia reset/termination without the atrial capture (n = 2/2) 1 cycle after the His-refractory PVC was specifically diagnostic. Exceptionally, the disappearance of the reset phenomenon was also observed in the two cNVP-ORTs. Step 3 was verification of the AVN as the cNVP insertion site, evidenced by an atrial reset/block preceding the His reset/block in fast-slow AVNRT with a cNVP-SP and slow-fast AVNRT with a cNVP-FP or His reset preceding the atrial reset in slow-fast AVNRT with a cNVP-SP. Conclusion: AVNRT with a bystander cNVP can be diagnosed in the three steps with few exceptions. Notably, tachycardia reset/termination without atrial capture one cycle after delivery of a His-refractory PVC is specifically diagnostic.

7.
J Interv Card Electrophysiol ; 67(1): 147-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37311981

RESUMO

BACKGROUND: The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS: Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS: Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS: The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.


Assuntos
Ablação por Cateter , Suínos , Animais , Vapor , Ventrículos do Coração/cirurgia , Arritmias Cardíacas/cirurgia
8.
J Interv Card Electrophysiol ; 67(3): 589-597, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691083

RESUMO

BACKGROUND: Lesion formation during catheter ablation is influenced by the power, contact force (CF), time, and catheter stability. However, the influence of the irrigation effects on lesion formation remains unknown. METHODS: An ex vivo experiment using conductive gel was performed. Using three different catheter designs (TactiFlex ™ SE [TF], IntellaNav MiFi ™ OI [MiFi], QDOT MICRO™ [QDOT]), a cross-sectional analysis of the lesion size and surface lesion type of 10g/40W lesions with a combination of various ablation times was performed in protocol 1. A longitudinal analysis (combination of various powers [30, 40, and 50W] and various ablation times with a 10g setting) was performed to investigate the influence of the auto-regulated irrigation system (QDOT) on lesion formation in protocol 2. RESULTS: The lesion formation with the QDOT catheter tended to create larger ablation lesions, while that with the TF catheter created smaller lesions than the other catheters. The lesion surface characteristics were divided into two patterns: ring (MiFi catheter and QDOT) and crescent (TF) patterns. The auto-regulated irrigation system did not influence the lesion formation, and the relationship between the lesion formation and RF energy exhibited similar changes regardless of the ablation power setting. CONCLUSION: The lesion formation and lesion surface characteristics differed among the different irrigation tip designs. An auto-regulated irrigation system did not affect the lesion creation or surface lesion characteristics. Care should be given to the inter-product differences in the lesion characteristics during RF catheter ablation, partly due to the irrigation flow control and tip design.


Assuntos
Ablação por Cateter , Irrigação Terapêutica , Humanos , Estudos Transversais , Irrigação Terapêutica/métodos , Catéteres , Ablação por Cateter/métodos , Impedância Elétrica , Desenho de Equipamento
9.
Sci Rep ; 13(1): 18875, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914708

RESUMO

Average beat interval (BI) and beat interval variability (BIV) are primarily determined by mutual entrainment between the autonomic-nervous system (ANS) and intrinsic mechanisms that govern sinoatrial node (SAN) cell function. While basal heart rate is not affected by age in humans, age-dependent reductions in intrinsic heart rate have been documented even in so-called healthy individuals. The relative contributions of the ANS and intrinsic mechanisms to age-dependent deterioration of SAN function in humans are not clear. We recorded ECG on patients (n = 16 < 21 years and n = 23 41-78 years) in the basal state and after ANS blockade (propranolol and atropine) in the presence of propofol and dexmedetomidine anesthesia. Average BI and BIV were analyzed. A set of BIV features were tested to designated the "signatures" of the ANS and intrinsic mechanisms and also the anesthesia "signature". In young patients, the intrinsic mechanisms and ANS mainly contributed to long- and short-term BIV, respectively. In adults, both ANS and intrinsic mechanisms contributed to short-term BIV, while the latter also contributed to long-term BIV. Furthermore, anesthesia affected ANS function in young patients and both mechanisms in adult. The work also showed that intrinsic mechanism features can be calculated from BIs, without intervention.


Assuntos
Atropina , Nó Sinoatrial , Adulto , Humanos , Propranolol , Frequência Cardíaca/fisiologia , Sistema Nervoso Autônomo/fisiologia , Eletrocardiografia
11.
J Cardiovasc Electrophysiol ; 34(9): 2002-2005, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37526239

RESUMO

BACKGROUND: A 70-year-old man revealed a rare type of atrioventricular nodal re-entrant tachycardia (AVNRT) involving distinct retrograde pathways, superior slow pathway, and inferolateral left atrial slow pathway. RESULT: Radiofrequency ablation was successfully performed on the noncoronary cusp and in the left atrium, respectively, to eliminate the tachycardias. DISCUSSION AND CONCLUSION: Due to the anomalous electrical conduction patterns, careful diagnosis and ablation strategies were necessary to avoid the risk of atrioventricular block. These findings underscore the diversity and complexity of AVNRT and highlight the importance of tailored therapeutic approaches.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Masculino , Humanos , Idoso , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Fascículo Atrioventricular , Átrios do Coração
12.
Artigo em Inglês | MEDLINE | ID: mdl-37561371

RESUMO

The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to lead-related complications. There are several causes of this stress, such as frequent upper extremity movements or external injury. Venous thoracic outlet syndrome (TOS) can also become the cause of external lead stress. However, the diagnosis of venous TOS can be challenging because subclavian venography can appear normal at first glance. We present a unique case of a device infection in a patient with venous TOS. A careful observation of the imaging studies is vital for diagnosing venous TOS and a leadless pacemaker implantation could be an alternative therapeutic option.

13.
J Gastroenterol ; 58(12): 1178-1187, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37572136

RESUMO

BACKGROUND: Functional dyspepsia (FD) and irritable bowel syndrome (IBS) are caused and exacerbated by consumption of fatty foods. However, no study has evaluated brain activity in response to food images in patients with disorders of gut-brain interaction (DGBI). This study aimed to compare food preference and brain activity when viewing food images between patients with DGBI and healthy controls. METHODS: FD and IBS were diagnosed using the ROME IV criteria. Food preference was assessed using a visual analog scale (VAS). Brain activity in the prefrontal cortex (PFC) in response to food images was investigated using functional near-infrared spectroscopy (fNIRS). RESULTS: Forty-one patients were enrolled, including 25 with DGBI. The mean VAS scores for all foods (controls vs. FD vs. IBS: 69.1 ± 3.3 vs. 54.8 ± 3.8 vs. 62.8 ± 3.7, p = 0.02), including fatty foods (78.1 ± 5.4 vs. 43.4 ± 6.3 vs. 64.7 ± 6.1, p < 0.01), were the lowest in patients with FD among all groups. Patients with FD had significantly higher brain activity in the left PFC than those with IBS and healthy controls (mean z-scores in controls vs. FD vs. IBS: - 0.077 ± 0.03 vs. 0.125 ± 0.04 vs. - 0.002 ± 0.03, p < 0.001). CONCLUSIONS: Patients with DGBI, particularly those with FD, disliked fatty foods. The brain activity in patients with DGBI differed from that in healthy controls. Increased activity in the PFC of patients with FD was confirmed.


Assuntos
Dispepsia , Síndrome do Intestino Irritável , Humanos , Dispepsia/diagnóstico por imagem , Síndrome do Intestino Irritável/diagnóstico por imagem , Alimentos , Medição da Dor , Encéfalo/diagnóstico por imagem
14.
Plant Cell Physiol ; 64(10): 1167-1177, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37498972

RESUMO

Plant seedlings adjust the growth of the hypocotyl in response to surrounding environmental changes. Genetic studies have revealed key players and pathways in hypocotyl growth, such as phytohormones and light signaling. However, because of genetic redundancy in the genome, it is expected that not-yet-revealed mechanisms can be elucidated through approaches different from genetic ones. Here, we identified a small compound, HYGIC (HG), that simultaneously induces hypocotyl elongation and thickening, accompanied by increased nuclear size and enlargement of cortex cells. HG-induced hypocotyl growth required the ethylene signaling pathway activated by endogenous ethylene, involving CONSTITUTIVE PHOTOMORPHOGENIC 1, ETHYLENE INSENSITIVE 2 (EIN2) and redundant transcription factors for ethylene responses, ETHYLENE INSENSITIVE 3 (EIN3) and EIN3 LIKE 1. By using EBS:GUS, a transcriptional reporter of ethylene responses based on an EIN3-binding-cis-element, we found that HG treatment ectopically activates ethylene responses at the epidermis and cortex of the hypocotyl. RNA-seq and subsequent gene ontology analysis revealed that a significant number of HG-induced genes are related to responses to hypoxia. Indeed, submergence, a representative environment where the hypoxia response is induced in nature, promoted ethylene-signaling-dependent hypocotyl elongation and thickening accompanied by ethylene responses at the epidermis and cortex, which resembled the HG treatment. Collectively, the identification and analysis of HG revealed that ectopic responsiveness to ethylene promotes hypocotyl growth, and this mechanism is activated under submergence.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Hipocótilo/metabolismo , Proteínas de Ligação a DNA/metabolismo , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Arabidopsis/metabolismo , Transdução de Sinais/fisiologia , Etilenos/farmacologia , Etilenos/metabolismo , Hipóxia , Regulação da Expressão Gênica de Plantas
15.
New Phytol ; 239(3): 936-948, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37270736

RESUMO

Soybeans (Glycine max) develop newly differentiated aerenchymatous phellem (AP) in response to waterlogging stress. AP is formed in the hypocotyl and root, thus contributing to internal aeration and adaptation to waterlogging for several legumes. Extensive accumulation of triterpenoids - lupeol and betulinic acid - has been identified in AP. However, their physiological roles in plants remain unclarified. Lupeol is converted from 2,3-oxidosqualene by lupeol synthase (LUS) and oxidized to betulinic acid. Notably, soybeans have two LUS genes (GmLUS1 and GmLUS2). Functional analysis was performed to reveal the biological and physiological functions of triterpenoids in AP using lus mutants. The AP cells of lus1 mutant lacked triterpenoid accumulation and epicuticular wax. Lupeol and betulinic acid were the major components of epicuticular wax and contributed to tissue hydrophobicity and oxygen transport to the roots. Tissue porosity in AP was lower in the lus1 mutant than in the wild-type, which resulted in reduced oxygen transport to the roots via AP. This reduction in oxygen transport resulted in shallow root systems under waterlogged conditions. Triterpenoid accumulation in AP contributes to effective internal aeration and root development for adaptation to waterlogging, suggesting the significance of triterpenoids in improving waterlogging tolerance.


Assuntos
Glycine max , Triterpenos , Glycine max/genética , Raízes de Plantas , Triterpenos/farmacologia , Oxigênio
17.
PeerJ ; 11: e15075, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37193030

RESUMO

Background: High-intensity exercise (HIE), such as that in marathons and triathlons, suppresses transient local and systemic immunity. Serum and salivary immunoglobulin heavy constant alpha 1 (IGHA1) are major markers of immunosuppression by HIE. Although much is known about the systemic immunosuppressive response, little is known about its local response in the oral cavity, lungs, bronchial tubes, and skin. The oral cavity allows bacteria or viruses to enter the body. Saliva covers the epidermis of the oral cavity and plays an important role in the local stress response by preventing infection. In this study, we examined the properties of saliva secreted during the local stress response for half-marathon (HM) induced IGHA1 protein expression using quantitative proteomics. Methods: The Exercise Group (ExG) (19 healthy female university students) participated in a HM race. The Non-Exercise Group (NExG) (16 healthy female university students) did not participate in the ExG. The ExG saliva samples were collected 1 h pre and 2 h and 4 h post-HM. The NExG saliva samples were collected at the same time intervals. The saliva volume, protein concentration, and relative IGHA1 expression were analyzed. In addition, 1 h pre and 2 h post- HM saliva samples were analyzed by iTRAQ. The identified factors in iTRAQ were analyzed for the ExG and the NExG using western blotting. Results: We identified kallikrein 1 (KLK1), immunoglobulin kappa chain (IgK), and cystatin S (CST4) as suppression factors, as well as IGHA1, which has been reported to be an immunological stress marker. IGHA1 (p = 0.003), KLK1 (p = 0.011), IGK (p = 0.002), and CST4 (p = 0.003) were suppressed 2 h post-HM compared with their levels pre HM, and IGHA1 (p < 0.001), KLK1 (p = 0.004), and CST4 (p = 0.006) were suppressed 4 h post-HM. There was also a positive correlation between IGHA1, IGK, and CST4 levels at 2 and 4 h post-HM. In addition, KLK1 and IGK levels at 2 h post-HM were positively correlated. Conclusion: Our study demonstrated that the salivary proteome is regulated, and antimicrobial proteins are suppressed post-HM. These results suggest that oral immunity was transiently suppressed post-HM. The positive correlation of each protein at 2 and 4 h post-HM suggests that the suppressed state was similarly regulated up to 4 h after a HM. The proteins identified in this study may have applications as stress markers for recreational runners and individuals who perform moderate to HIE on a regular basis.


Assuntos
Corrida de Maratona , Saliva , Humanos , Feminino , Boca , Exercício Físico , Proteínas e Peptídeos Salivares/metabolismo
18.
J Arrhythm ; 39(2): 166-174, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37021033

RESUMO

Background: Recently, a novel contact force (CF) sensing catheter with mesh-shaped irrigation tip (TactiFlex SE, Abbott) was invented and is expected to be useful for safe and effective radiofrequency ablation. However, this catheter's detailed characteristics of the lesion formation are unknown. Methods: With an in vitro model, TactiFlex SE and its predecessor, FlexAbility SE, were used. A cross-sectional analysis of 60 s lesions (combination of various energy power settings [30, 40, and 50 W], and CFs [10, 30, and 50 g]) and longitudinal analysis (combination of various powers [40 or 50 W], CFs [10, 30, and 50 g] and ablation times [10, 20, 30, 40, 50, and 60 s]) of both catheters were analyzed and compared. Results: One hundred eighty RF lesions were created in protocol 1 and 300 in protocol 2. The lesion formation, impedance changes, and steam pops characteristics were similar between the two catheters. Higher CFs were related to higher incidences of steam pops. A nonlinear, time-dependent increase in the lesion depth and diameter was observed for all power and CF settings, and linear, positive correlations between the RF delivery time and lesion volume were observed for all power settings. Compared with 40 W, a 50 W ablation created greater lesions. Longer durations with higher CF settings had a higher steam pop incidence. Conclusions: The lesion formation and incidence of steam pops with TactiFlex SE and FlexAbility SE were similar. A 40 or 50 W ablation with careful CF control not to exceed 30 g in addition to monitoring impedance drops was required to safely create transmural lesions.

20.
J Cardiol ; 82(1): 76-83, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36935004

RESUMO

BACKGROUND: A novel Diamond Temp™ (DT; Medtronic, Minneapolis, MN, USA) catheter has enabled performing a surface temperature-controlled ablation. The chemical vapor deposition diamond of the ablation catheter acts as a thermal radiator and is useful for effective cooling of the ablation catheter tip. However, a detailed analysis of the lesion formation with this catheter remains unknown. METHODS: DT catheters were used in an excised swine heart experimental model. A cross-sectional analysis of 60-s lesions [a combination of various energy power settings (30, 40, and 50 W), and various contact forces (CF) (10, 30, and 50 g)] and a longitudinal analysis [a combination of various powers (40 W or 50 W), various CFs (10, 30, and 50 g), and various ablation times (5 s, 10 s, 15 s, 20 s, 25 s, 30 s, and 60 s)] of the DT catheter were analyzed. RESULTS: The maximum lesion depth, maximum diameter, and lesion volume with a 10 g ablation were significantly lower than those with a 30 g or 50 g ablation. There were no significant differences in the lesion formation between the 30 g ablation and 50 g ablation under each radiofrequency (RF) power setting. The impedance drops with steam pops were significantly greater than those without steam pops (pop (+) vs. pop (-), 26.2 ±â€¯6.6 Ohm vs. 18.4 ±â€¯7.1 Ohm, p = 0.0001). A non-linear, time-dependent increase in the lesion depth and diameter was observed for all power and CF settings. Comparing the lesion depth and diameter between 40 W and 50 W under the same CF setting and same ablation time, most of the settings had no significant difference. CONCLUSION: Ablation lesions created with the DT catheter were similar to other catheters. Similar ablation lesions were created with the 40 W or 50 W ablation under the same CF setting and same ablation time. Regardless of the ablation power, monitoring the general impedance during the RF application was indispensable for a safe procedure.


Assuntos
Ablação por Cateter , Vapor , Animais , Suínos , Estudos Transversais , Catéteres , Coração , Ventrículos do Coração/patologia , Ablação por Cateter/métodos , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...