Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Surg ; 14(1): 141, 2019 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-31337418

RESUMO

BACKGROUND: Severe carotid and intracranial artery stenosis disease (CIAD) is major risk for perioperative stroke in coronary artery bypass grafting. Then, preoperative risk assessment is quite important. CASE PRESENTATION: A 58-years old Japanese woman with bilateral carotid stenosis and bilateral middle cerebral artery occlusion was suffered from worsening effort angina due to severe three coronary vessel disease. Magnetic resonance imaging angiography demonstrated severe carotid and intracranial vessel stenosis. Selective carotid/cerebral angiography also showed severe stenosis and delayed filling of the right internal carotid artery and moderate stenosis of the left internal carotid artery, with occlusion of the bilateral middle cerebral arteries. However, quantitative evaluation with brain perfusion, single-photon emission computed tomography (SPECT) with acetazolamide showed depleted cerebral perfusion volume and vascular responses, particularly in the left middle cerebral artery area. However, both sides of MCA reserve cerebral blood flow was maintained at > 34 ml/100 g/min. So, we finally considered that her cerebral perfusion reserve was maintained a certain level and could tolerate open heart surgery. Then, she underwent off-pump coronary artery grafting. Before sternotomy, prophylactic intra-aortic balloon pump support was used to minimize possible perioperative stroke. As a result, hemodynamic status and brain regional oxygen saturation were stable throughout the operation, and recovered uneventfully. CONCLUSIONS: Preoperative quantitative evaluation using brain perfusion SPECT with acetazolamide is useful in assessing hemodynamic cerebrovascular risk in patients with severe obstructive CIAD. Off pump coronary artery bypass grafting with intra aortic balloon pump assist is a good option for prevention of cerebrovascular morbidity in ischemic heart disease with severe CIAD.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Artérias Cerebrais/diagnóstico por imagem , Acetazolamida/administração & dosagem , Estenose das Carótidas/fisiopatologia , Estenose das Carótidas/cirurgia , Artérias Cerebrais/fisiopatologia , Artérias Cerebrais/cirurgia , Circulação Cerebrovascular , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/fisiopatologia , Constrição Patológica/cirurgia , Ponte de Artéria Coronária , Feminino , Humanos , Angiografia por Ressonância Magnética , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Medição de Risco , Acidente Vascular Cerebral/prevenção & controle , Tomografia Computadorizada de Emissão de Fóton Único
2.
J Cardiothorac Surg ; 10: 142, 2015 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-26525578

RESUMO

BACKGROUND: In rare cases, echo findings of degenerative valve disease is similar to valvular mass. CASE PRESENTATION: A 56-year-old woman was evaluated for palpitation. Echocardiography revealed an 8- mm mass on the anterior mitral leaflet with minimal mitral insufficiency. Resection of the valve tumor was attempted to prevent a possible embolism. However, the lesion was not a tumor, but an aneurysm-like bulge on the anterior leaflet without chorda elongation. Triangular resection and ring annuloplasty were performed. The patient's postoperative course was uneventful. Pathological examination revealeddegenerative disease. CONCLUSIONS: This case illustrates that a valvular mass that looks like a tumor by echocardiography may actually be degenerative regardless of the presence of mitral insufficiency.


Assuntos
Aneurisma Cardíaco/diagnóstico , Insuficiência da Valva Mitral/diagnóstico , Diagnóstico Diferencial , Ecocardiografia , Feminino , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/cirurgia , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
3.
Circ J ; 77(1): 105-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23001071

RESUMO

BACKGROUND: The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. METHODS AND RESULTS: Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. CONCLUSIONS: Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
4.
J Card Surg ; 27(2): 174-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22151083

RESUMO

The abnormal origin of the left circumflex artery from the proximal right coronary artery (RCA) is considered a coronary artery anomaly. Most of the coronary artery anomalies are diagnosed incidentally by coronary artery angiography, and several considerations are needed to avoid fatal complications in patients undergoing aortic valve replacement (AVR). We report a case of AVR with anomalous origin of the left circumflex artery from a common ostium of the RCA, and discuss the use of a smaller prosthesis to avoid compression of the anomalous left circumflex artery.


Assuntos
Estenose da Valva Aórtica/cirurgia , Anomalias dos Vasos Coronários/complicações , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Valva Aórtica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Anomalias dos Vasos Coronários/diagnóstico por imagem , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Radiografia
5.
Surg Today ; 41(7): 999-1002, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21748621

RESUMO

We herein describe a rare case of a concurrent submitral left ventricular (LV) aneurysm and an aneurysm of the sinus of Valsalva in a 65-year-old Japanese woman. The patient had a history of mitral valve replacement (MVR) for mitral regurgitation caused by a submitral LV aneurysm at the age of 58. At the time of the MVR, the orifice of the submitral LV aneurysm without thrombi was beneath the posterior leaflet, but surgical repair of the submitral LV aneurysm was not attempted. Although the patient was asymptomatic, when she underwent an echocardiogram at 65 years of age an aneurysm of the noncoronary sinus of Valsalva was detected. However, echocardiography performed before the initial operation had shown that the aneurysm of the sinus of Valsalva was coexistent with the submitral LV aneurysm. Since the submitral LV aneurysm revealed no progressive enlargement during the 7 years, patch closure of the aneurysm of the sinus of Valsalva alone was successfully performed.


Assuntos
Aneurisma da Aorta Torácica/patologia , Aneurisma Cardíaco/patologia , Cardiopatias Congênitas/patologia , Ventrículos do Coração/patologia , Seio Aórtico/patologia , Disfunção Ventricular Esquerda/patologia , Idoso , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/diagnóstico por imagem , Feminino , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Seio Aórtico/diagnóstico por imagem , Fatores de Tempo , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico por imagem
6.
J Artif Organs ; 14(3): 209-14, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21534012

RESUMO

Our aim was to evaluate the long-term results of implantation of the Carpentier-Edwards pericardial (CEP) valve in the aortic position. Between January 1996 and December 2007, 244 patients who underwent aortic valve replacement using the CEP valve were enrolled in this study. A 19-mm valve was used in 39 patients, a 21-mm valve in 94 patients, a 23-mm valve in 81 patients, and a 25-mm valve in 30 patients. The early and the late results were evaluated. Furthermore, echocardiographic examination was performed at follow-up. There were 5 early deaths, with an early mortality rate of 2.0%. Follow-up was performed in 95.4% of the survivors of the operation for a mean period of 4.1 years. Actuarial survival rates at 5, 10, and 12 years were 85.3 ± 2.8, 80.0 ± 3.7 and 70.0 ± 9.8%, respectively. Thromboembolism was observed in 6 patients, endocarditis in 2 patients, reoperation in 4 patients, and structural valve deterioration in 2 patients. Actuarial freedoms from thromboembolism, endocarditis, and reoperation at 10 years were 96.9 ± 0.14, 97.7 ± 0.16, and 97.0 ± 0.16%, respectively. Echocardiographic examination revealed that the pressure gradients across the valve prosthesis for valves of each size were acceptable. Left ventricular mass index decreased significantly in all valve sizes. The long-term results of implantation of the CEP bioprosthesis in the aortic position were satisfactory. The CEP bioprosthesis maintained its hemodynamic performance even as late as 10 years after implantation.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida
7.
Ann Thorac Surg ; 89(3): 955-7, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20172164

RESUMO

We report a case of recurrent mitral regurgitation due to calcification of the expanded polytetrafluoroethylene sutures. According to pathologic findings, it was believed that due to the dystrophic calcification of the fibrous tissue covering the expanded polytetrafluoroethylene sutures, there was increased hyalinization, leading to sclerosis and shortening of the chordae. Calcification of expanded polytetrafluoroethylene sutures after mitral valve repair is a rare complication; however, careful follow-up should be needed because such change may occur in long-term periods after implantation.


Assuntos
Calcinose/complicações , Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Politetrafluoretileno , Suturas/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Recidiva , Reoperação , Esclerose
8.
Geriatr Gerontol Int ; 9(3): 329-32, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19702946

RESUMO

Patent ductus arteriosus is the third most common congenital cardiovascular anomaly, however, it is rarely found in the elderly. We describe a case of patent ductus arteriosus in a 72-year-old woman in whom patent ductus arteriosus was successfully managed by transcatheter coil embolization. The patient had been diagnosed with a heart murmur for the first time 1 year earlier at the age of 71. She was asymptomatic but a continuous murmur was heard. Cardiac catheterization revealed migration of a catheter from the main pulmonary artery into the descending aorta through a patent ductus arteriosus and a significant step-up of oxygen saturation in the main pulmonary artery with a pulmonary-to-systemic flow ratio of 1.68. Aortograms demonstrated a communication between the aorta and the pulmonary artery through a patent ductus arteriosus with a minimal diameter of 3.7 mm. Transcatheter coil embolization of the patent ductus arteriosus was successfully carried out with two 0.052-inch-diameter Gianturco coils. Doppler echocardiographic study confirmed no residual shunt in the main pulmonary artery after the procedure. Non-surgical transcatheter occlusion using coil embolization appears to be an effective and minimally invasive technique for treatment of patent ductus arteriosus in the elderly.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/terapia , Embolização Terapêutica , Idoso , Ecocardiografia Doppler , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...