Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 22(1): 537, 2021 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-34118902

RESUMO

BACKGROUND: Before the role of shear wave elastography (SWE) and B mode ultrasound (US) in the diagnosis of different forms of idiopathic inflammatory myopathies (IIM) can be investigated, normative data is required. This study aimed to describe and then compare normative SWE and B mode ultrasound metrics of muscles in healthy controls and patients with IIM. METHODS: Twenty nine healthy adult controls and 10 IIM patients (5 with inclusion body myositis and 5 with necrotising autoimmune myopathy) underwent a full clinical examination, laboratory investigations, SWE and US measurements of selected proximal and distal limb muscles. Shear wave speed (SWS) and multiple US domains [echogenicity, fascial thickness, muscle bulk and power Doppler (PD)] were measured in both groups. RESULTS: In healthy controls (n = 29; mean age 46.60 ± 16.10; 44.8 % female), age was inversely correlated with SWS at the deltoid (stretch) (Rs. -0.40, p = 0.030) and PD score at the deltoid (rest) (Rs. -0.40, P = 0.032). Those ≥ 50 years old had a lower SWS at the deltoid (stretch) compared to the < 50 year group (2.92 m/s vs. 2.40 m/s, P = 0.032). Age correlated with increased echogenicity in the flexor digitorum profundus (Rs. 0.38, P = 0.045). Females had a smaller muscle bulk in the deltoid (P = 0.022). Body mass index (BMI) was inversely associated with SWS in the deltoid (stretch) (Rs - 0.45, P = 0.026), and positively correlated with echogenicity in the deltoid (Rs. 0.69, P = 0.026). In patients ≥50 years of age, patients with IIM (mean age 61.00 ± 8.18; females 20.0 %) had a higher proportion of abnormal echogenicity scores at the flexor digitorum profundus (FDP) (40.00 % vs. 14.30 %, P = 0.022) and tibialis anterior (TA) (80.00 % vs. 28.60 %, P = 0.004). Fascial thickness was lower in the FDP (0.63mm vs. 0.50mm, p = 0.012) and TA (0.58mm vs. 0.45mm, P = 0.001). CONCLUSIONS: Our findings suggest there is scope for US techniques to be useful for diagnostic screening of affected muscles in patients with IIM, especially in those with suspected inclusion body myositis or necrotising autoimmune myopathy. We provide normative data for future studies into SWE and US techniques in skeletal muscle. The differences between IIM patients and controls warrant further study in a broader IIM patient cohort.


Assuntos
Técnicas de Imagem por Elasticidade , Miosite , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Miosite/diagnóstico por imagem , Ultrassonografia , Ultrassonografia Doppler
2.
Cancer Res ; 80(8): 1773-1783, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32295783

RESUMO

Inadequate margins in breast-conserving surgery (BCS) are associated with an increased likelihood of local recurrence of breast cancer. Currently, approximately 20% of BCS patients require repeat surgery due to inadequate margins at the initial operation. Implementation of an accurate, intraoperative margin assessment tool may reduce this re-excision rate. This study determined, for the first time, the diagnostic accuracy of quantitative micro-elastography (QME), an optical coherence tomography (OCT)-based elastography technique that produces images of tissue microscale elasticity, for detecting tumor within 1 mm of the margins of BCS specimens. Simultaneous OCT and QME were performed on the margins of intact, freshly excised specimens from 83 patients undergoing BCS and on dissected specimens from 7 patients undergoing mastectomy. The resulting three-dimensional images (45 × 45 × 1 mm) were coregistered with postoperative histology to determine tissue types present in each scan. Data from 12 BCS patients and the 7 mastectomy patients served to build a set of images for reader training. One hundred and fifty-four subimages (10 × 10 × 1 mm) from the remaining 71 BCS patients were included in a blinded reader study, which resulted in 69.0% sensitivity and 79.0% specificity using OCT images, versus 92.9% sensitivity and 96.4% specificity using elasticity images. The quantitative nature of QME also facilitated development of an automated reader, which resulted in 100.0% sensitivity and 97.7% specificity. These results demonstrate high accuracy of QME for detecting tumor within 1 mm of the margin and the potential for this technique to improve outcomes in BCS. SIGNIFICANCE: An optical imaging technology probes breast tissue elasticity to provide accurate assessment of tumor margin involvement in breast-conserving surgery.


Assuntos
Adenocarcinoma Mucinoso/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Margens de Excisão , Mastectomia Segmentar/métodos , Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Mucinoso/cirurgia , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Mastectomia Segmentar/normas , Pessoa de Meia-Idade , Reoperação , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...