Ann Thorac Surg ; 85(6): 2139-40, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18498847

RESUMO

Aneurysm of the left atrial appendage (LAA) is very infrequent. We present the case of 24-year-old man in functional class I with atrial fibrillation but no other symptoms. Radiology showed an abnormality in the outline of the heart. Echocardiography revealed left appendage aneurysm. After median sternotomy, aneurysmectomy was performed under cardiopulmonary bypass without cross clamping. Atrial fibrillation ceased as soon as the aneurysm had been removed. There were no postoperative complications. Three months later the patient remained asymptomatic and in sinus rhythm.


Assuntos
Apêndice Atrial/anormalidades , Fibrilação Atrial/etiologia , Aneurisma Cardíaco/congênito , Adulto , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/patologia , Apêndice Atrial/cirurgia , Descompressão Cirúrgica/instrumentação , Seguimentos , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/patologia , Aneurisma Cardíaco/cirurgia , Humanos , Masculino , Instrumentos Cirúrgicos , Ultrassonografia
3.
Artif Organs ; 26(10): 851-5, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12296924

RESUMO

We evaluated our results over 13 years with the aortic-position Medtronic Intact bioprosthesis. Our study involved 91 consecutive patients with isolated aortic valve replacement with the Medtronic Intact bioprosthesis. The follow-up was complete for 95%. Mean follow-up was 6.61 years (range 16 days-13 years), 590 patient years. Early mortality rate was 3.3%. Late mortality was 23 patients. Survival at 13 years was 53.52% (SD = 7.63%). The linearized rate of major thromboembolism was 0.34% per patient year; rate of major bleeding events was 0.33% per patient year. The rate of nonstructural dysfunction was 0.16% per patient year. Rate of reoperation was 0.53% and rate of structural valve deterioration was 0.16% per patient year. New York Heart Association (NYHA) postoperative classes were I to II in 92.21%. Gradients were as follows: 21 to 23.87 mm Hg, 23 to 18 mm Hg, 25 to 15.5 mm Hg, and 27 to 16.50 mm Hg. Structural valve deterioration was low during the 13 years of follow-up. Valve gradients and areas remained the same over the follow-up period. The Medtronic Intact bioprosthesis shows excellent clinical and hemodynamic performance at 13 years of follow up.


Assuntos
Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Bioprótese , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento