Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(3): e0298331, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38530838

RESUMO

Electrochemical measurements, which exhibit high accuracy and sensitivity under low contamination, controlled electrolyte concentration, and pH conditions, have been used in determining various compounds. The electrochemical quantification capability decreases with an increase in the complexity of the measurement object. Therefore, solvent pretreatment and electrolyte addition are crucial in performing electrochemical measurements of specific compounds directly from beverages owing to the poor measurement quality caused by unspecified noise signals from foreign substances and unstable electrolyte concentrations. To prevent such signal disturbances from affecting quantitative analysis, spectral data of voltage-current values from electrochemical measurements must be used for principal component analysis (PCA). Moreover, this method enables highly accurate quantification even though numerical data alone are challenging to analyze. This study utilized boron-doped diamond (BDD) single-chip electrochemical detection to quantify caffeine content in commercial beverages without dilution. By applying PCA, we integrated electrochemical signals with known caffeine contents and subsequently utilized principal component regression to predict the caffeine content in unknown beverages. Consequently, we addressed existing research problems, such as the high quantification cost and the long measurement time required to obtain results after quantification. The average prediction accuracy was 93.8% compared to the actual content values. Electrochemical measurements are helpful in medical care and indirectly support our lives.


Assuntos
Cafeína , Café , Cafeína/análise , Boro/química , Eletrodos , Aprendizado de Máquina , Eletrólitos
2.
Sensors (Basel) ; 23(17)2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37688114

RESUMO

Optical sensing offers several advantages owing to its non-invasiveness and high sensitivity. The miniaturization of optical sensors will mitigate spatial and weight constraints, expanding their applications and extending the principal advantages of optical sensing to different fields, such as healthcare, Internet of Things, artificial intelligence, and other aspects of society. In this study, we present the development of a miniature optical sensor for monitoring thrombi in extracorporeal membrane oxygenation (ECMO). The sensor, based on a complementary metal-oxide semiconductor integrated circuit (CMOS-IC), also serves as a photodiode, amplifier, and light-emitting diode (LED)-mounting substrate. It is sized 3.8 × 4.8 × 0.75 mm3 and provides reflectance spectroscopy at three wavelengths. Based on semiconductor and microelectromechanical system (MEMS) processes, the design of the sensor achieves ultra-compact millimeter size, customizability, prototyping, and scalability for mass production, facilitating the development of miniature optical sensors for a variety of applications.

3.
Micromachines (Basel) ; 13(5)2022 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-35630157

RESUMO

Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (µPADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32 °C and more pores were opened at temperatures above 32 °C. Valve permeability tests confirmed that the proposed polymerized membrane was impermeable to water and proteins at temperatures below 32 °C and permeable to water at temperatures above 32 °C. The valve could also be reversibly and repeatedly opened and closed by changing the temperature near 32 °C. These results suggest that plasma-induced graft polymerization may be used to produce thermo-responsive valves that can be opened and closed without subsequent loss of performance. These results indicate that the thermo-responsive valve fabricated by plasma-induced graft polymerization could potentially be applied to ELISA with µPADs.

4.
Nanomaterials (Basel) ; 12(10)2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35630964

RESUMO

Owing to its simplicity and sensitivity, electrochemical analysis is of high significance in the detection of pollutants and highly toxic substances in the environment. In electrochemical analysis, the sensitivity of the sensor and reliability of the obtained signal are especially dependent on the electrode characteristics. Electrodes with a high density of nanomaterials, which exhibit excellent activity, are useful as sensor substrates for pollutant detection. However, the effective placement of high-density nanomaterials requires a high degree of control over the particle size, particle shape, and distance between the particles on the substrate. In this study, we exploited the properties of boron-doped diamond (BDD) electrodes, which have a wide potential window, and succeeded in coating a highly dense layer of gold nanoparticles (AuNPs) at high potential. The AuNP-modified BDD (AuNP-BDD) electrodes comprising less than 100 nm AuNPs at a density of 125 particles/µm were electrochemically synthesized over a short period of 30-60 s. The AuNP-BDD electrodes were applied for detecting arsenic, which is one of the most abundant elements, and exhibited a limit of detection of 0.473 ppb in solution.

5.
Anim Sci J ; 92(1): e13606, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34318565

RESUMO

Control of blood retinol levels in cattle during fattening is important in the production of marbled beef. However, it is difficult to easily measure the blood retinol concentration in the field. In this study, we attempted to develop an analysis method that does not require blood cell separation and uses a compact fluorescence analyzer that can be carried around as a preliminary system for measuring blood retinol concentration in the field. This system was used to monitor blood retinol levels in 12 fattening cattle (14 to 27 months old) and demonstrated a strong correlation (r = 0.78) with the results obtained by the standard high-performance liquid chromatography (HPLC) method. Stronger correlations (r = 0.87) were obtained until the cattle were 24 months of age. These results suggest that higher correlations can be expected to be obtained by improving the robustness of the extraction system. Refinements for practical use need to be considered, but whole blood extraction and the vitamin A analyzer that was developed show potential to be used for on-farm monitoring of retinol levels.


Assuntos
Vitamina A , Animais , Bovinos , Cromatografia Líquida de Alta Pressão/veterinária , Vitamina A/análise , Vitamina A/sangue
6.
Int J Artif Organs ; 44(8): 565-573, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33300399

RESUMO

INTRODUCTION: Real-time, non-invasive monitoring of thrombus formation in extracorporeal circuits has yet to be achieved. To address the challenges of conventional optical thrombus detection methods requiring large devices that limit detection capacity, we developed a micro-optical thrombus sensor. METHODS: The proposed micro-optical thrombus sensor can detect the intensity of light scattered by blood at wavelengths of 660 and 855 nm. Two thrombus sensors were installed on in vitro circuit: one at the rotary blood pump and one at a flow channel. To evaluate the variation in the ratio of incident light intensity at each wavelength of the two sensors, Rfluct (for 660 nm) and Ifluct (for 855 nm) were defined. Using fresh porcine blood as a working fluid, we performed in vitro tests of haematocrit (Hct) and oxygen saturation (SaO2) variation and thrombus detection. Thrombus tests were terminated after Rfluct or Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. RESULTS: In all three thrombus detection tests, Ifluct showed a larger change than the maximum range of those in the Hct and SaO2 variation test. After the tests, thrombus formation was confirmed in the pump, and there was no thrombus in the flow channel. The results indicate that Ifluct is an effective parameter for identifying the presence of a thrombus. CONCLUSION: Thrombus detection in an extracorporeal circuit using the developed micro-optical sensors was successfully demonstrated in an in vitro test.


Assuntos
Trombose , Animais , Hematócrito , Suínos , Trombose/diagnóstico por imagem
7.
Sensors (Basel) ; 20(17)2020 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-32847124

RESUMO

In livestock production, point-of-care testing (POCT) technology that enables easy on-site analysis of sex hormones is desired to improve reproductive efficiency. In this context, low-molecular-weight endogenous steroids are particularly important for perinatal management. Therefore, we attempted to use a simple method that combines electrochemical techniques with immunochromatography to measure estrone-3-sulfate (E1S), one of the low-molecular-weight endogenous steroids that is an estrogen ester. The limit of detection (LOD) for E1S achieved by electrochemical immunochromatography was 570.5 ng/mL, which was one to two orders of magnitude lower than that of small molecule compounds analyzed by other POCT techniques (Primpray et al., Anal. Chim. Acta, 2019). In addition, it was indicated by a colorimetric analysis that the sensitivity of the electrochemical immunochromatographic technique could be enhanced by improving the method of application of the antibodies on the nitrocellulose membrane and the contact between the electrochemical detector and the nitrocellulose membrane.


Assuntos
Técnicas Eletroquímicas , Estrona/análogos & derivados , Cromatografia de Afinidade , Limite de Detecção
8.
Sensors (Basel) ; 18(2)2018 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-29360799

RESUMO

The purpose of this paper is to show the feasibility of grasping force control by feeding back signals of the developed micro-laser Doppler velocimeter (µ-LDV) and by discriminating whether a grasped object is slipping or not. LDV is well known as a high response surface velocity sensor which can measure various surfaces-such as metal, paper, film, and so on-thus suggesting the potential application of LDV as a slip sensor for grasping various objects. However, the use of LDV as a slip sensor has not yet been reported because the size of LDVs is too large to be installed on a robotic fingertip. We have solved the size problem and enabled the performance of a feasibility test with a few-millimeter-scale LDV referred to as micro-LDV (µ-LDV) by modifying the design which was adopted from MEMS (microelectromechanical systems) fabrication process. In this paper, by applying our developed µ-LDV as a slip sensor, we have successfully demonstrated grasping force control with three target objects-aluminum block, wood block, and white acrylic block-considering that various objects made of these materials can be found in homes and factories, without grasping force feedback. We provide proofs that LDV is a new promising candidate slip sensor for grasping force control to execute target grasping.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...