Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 312
Filtrar
1.
Ann Thorac Surg ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38723881

RESUMO

BACKGROUND: To provide patients and surgeons with clinically relevant information, the Society of Thoracic Surgeons Adult Cardiac Surgery Database (STS-ACSD) was queried to develop a risk model for isolated tricuspid valve (TV) operations. METHODS: All patients in the STS-ACSD undergoing isolated TV repair or replacement (N=13,587; age 48.3±18.4 years) were identified (7/2017-6/2023). Multivariable logistic regression accounting for TV replacement versus repair was used to model eight operative outcomes: mortality, morbidity and/or mortality, stroke, renal failure, reoperation, prolonged ventilation, short and prolonged hospital stay. Model discrimination (C-statistic) and calibration were assessed using 9-fold cross-validation. RESULTS: The isolated TV study population included 41.1% repairs (N=5,583; age 52.6±18.1 years) and 58.9% replacements (N=8,004; age 45.3±18.0 years). Overall predicted risk of operative mortality was 5.6%, similar in repairs and replacements (5.5% and 5.7%, respectively); as was the predicted risk of composite morbidity and mortality (28.2% and 26.8%). Replacements were generally younger patients with a higher endocarditis prevalence than repairs (45.7% vs. 21.1%). The model yielded a C-statistic of 0.81 for mortality and 0.76 for the composite of morbidity and mortality, with excellent observed-to-expected calibration that was comparable in all sub-cohorts and predicted risk decile groups. CONCLUSIONS: A new STS risk model has been developed for isolated TV surgery. The current mortality of isolated TV operations is lower than previously observed. This risk prediction model and these contemporary outcomes provide a new benchmark for current and future isolated TV interventions.

2.
Insights Imaging ; 15(1): 80, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38502298

RESUMO

OBJECTIVES: Artificial intelligence (AI) has tremendous potential to help radiologists in daily clinical routine. However, a seamless, standardized, and time-efficient way of integrating AI into the radiology workflow is often lacking. This constrains the full potential of this technology. To address this, we developed a new reporting pipeline that enables automated pre-population of structured reports with results provided by AI tools. METHODS: Findings from a commercially available AI tool for chest X-ray pathology detection were sent to an IHE-MRRT-compliant structured reporting (SR) platform as DICOM SR elements and used to automatically pre-populate a chest X-ray SR template. Pre-populated AI results could be validated, altered, or deleted by radiologists accessing the SR template. We assessed the performance of this newly developed AI to SR pipeline by comparing reporting times and subjective report quality to reports created as free-text and conventional structured reports. RESULTS: Chest X-ray reports with the new pipeline could be created in significantly less time than free-text reports and conventional structured reports (mean reporting times: 66.8 s vs. 85.6 s and 85.8 s, respectively; both p < 0.001). Reports created with the pipeline were rated significantly higher quality on a 5-point Likert scale than free-text reports (p < 0.001). CONCLUSION: The AI to SR pipeline offers a standardized, time-efficient way to integrate AI-generated findings into the reporting workflow as parts of structured reports and has the potential to improve clinical AI integration and further increase synergy between AI and SR in the future. CRITICAL RELEVANCE STATEMENT: With the AI-to-structured reporting pipeline, chest X-ray reports can be created in a standardized, time-efficient, and high-quality manner. The pipeline has the potential to improve AI integration into daily clinical routine, which may facilitate utilization of the benefits of AI to the fullest. KEY POINTS: • A pipeline was developed for automated transfer of AI results into structured reports. • Pipeline chest X-ray reporting is faster than free-text or conventional structured reports. • Report quality was also rated higher for reports created with the pipeline. • The pipeline offers efficient, standardized AI integration into the clinical workflow.

3.
Brain Spine ; 4: 102747, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38510616

RESUMO

Introduction: Autism spectrum disorder (ASD) is characterized by deficits in social communication, repetitive behaviors, and can be accompanied by a spectrum of psychiatric symptoms, such as schizophrenia and catatonia. Rarely, these symptoms, if left untreated, can result in spinal deformities. Research question and case description: This case report details the treatment of a 16-year-old male ASD patient with catatonic schizophrenia and mutism, presenting with neck pain, left-rotated torticollis, and fever. MRI revealed atlantoaxial rotational instability and spinal cord compression from a dislocated dens axis. After inconclusive biopsies, empirical antibiotics, hard collar and halo fixation treatment, persistent instability necessitated C1/2 fusion. The ongoing catatonia was addressed with electroconvulsive therapy. Concurrently, he developed severe subaxial hyperkyphosis. The report examines the decision-making between conservative and surgical management for an adolescent with significant psychiatric comorbidity and progressive spinal symptoms against a backdrop of uncertain etiology. Materials and methods: A case report and review of the literature. Results: Posterior C1-C7 stabilization was successfully executed, effectively restoring cervical sagittal alignment, which was maintained throughout a two-year follow-up. Concurrently, the catatonia resolved. Discussion and conclusion: To our knowledge, this is the third reported case of severe cervical deformity associated with fixed posture in a psychiatric patient. This case report emphasizes the critical importance of multidisciplinary collaboration in managing the interplay between neuropsychiatric disorders and severe spinal deformities. It showcases the practicality and efficacy of surgical intervention for persistent cervical deformity in pediatric schizophrenia patients, highlighting the necessity for a comprehensive risk-benefit analysis.

4.
Eur J Radiol ; 174: 111386, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447431

RESUMO

PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Átrios do Coração , Variações Dependentes do Observador , Função Ventricular Esquerda
5.
Artigo em Inglês | MEDLINE | ID: mdl-38467531

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly performed for the treatment of aortic stenosis. Computed tomography (CT) analysis is essential for pre-procedural planning. Currently available software packages for TAVR planning require substantial human interaction. We describe development and validation of an artificial intelligence (AI) powered software to automatically rend anatomical measurements and other information required for TAVR planning and implantation. METHODS: Automated measurements from 100 CTs were compared to measurements from three expert clinicians and TAVR operators using commercially available software packages. Correlation coefficients and mean differences were calculated to assess precision and accuracy. RESULTS: AI-generated annular measurements had excellent agreements with manual measurements by expert operators yielding correlation coefficients of 0.97 for both perimeter and area. There was no relevant bias with a mean difference of -0.07 mm and - 1.4 mm2 for perimeter and area, respectively. For the ascending aorta measured 5 cm above the annular plane, correlation coefficient was 0.95 and mean difference was 1.4 mm. Instruction for use-based sizing yielded agreement with the effective implant size in 87-88 % of patients for self-expanding valves (perimeter-based sizing) and in 88 % for balloon-expandable valves (area-based sizing). CONCLUSIONS: A fully automated software enables accurate and precise anatomical segmentation and measurements required for TAVR planning without human interaction and with high reliability.

6.
Radiology ; 310(2): e231956, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38376407

RESUMO

Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Constrição Patológica , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia Coronária
7.
AJR Am J Roentgenol ; 222(3): e2330481, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38197760

RESUMO

BACKGROUND. Calcium blooming causes stenosis overestimation on coronary CTA. OBJECTIVE. The purpose of this article was to evaluate the impact of virtual monoenergetic imaging (VMI) reconstruction level on coronary artery stenosis quantification using photon-counting detector (PCD) CT. METHODS. A phantom containing two custom-made vessels (representing 25% and 50% stenosis) underwent PCD CT acquisitions without and with simulated cardiac motion. A retrospective analysis was performed of 33 patients (seven women, 26 men; mean age, 71.3 ± 9.0 [SD] years; 64 coronary artery stenoses) who underwent coronary CTA by PCD CT followed by invasive coronary angiography (ICA). Scans were reconstructed at nine VMI energy levels (40-140 keV). Percentage diameter stenosis (PDS) was measured, and bias was determined from the ground-truth stenosis percentage in the phantom and ICA-derived quantitative coronary angiography measurements in patients. Extent of blooming artifact was measured in the phantom and in calcified and mixed plaques in patients. RESULTS. In the phantom, PDS decreased for 25% stenosis from 59.9% (40 keV) to 13.4% (140 keV) and for 50% stenosis from 81.6% (40 keV) to 42.3% (140 keV). PDS showed lowest bias for 25% stenosis at 90 keV (bias, 1.4%) and for 50% stenosis at 100 keV (bias, -0.4%). Blooming artifacts decreased for 25% stenosis from 61.5% (40 keV) to 35.4% (140 keV) and for 50% stenosis from 82.7% (40 keV) to 52.1% (140 keV). In patients, PDS for calcified plaque decreased from 70.8% (40 keV) to 57.3% (140 keV), for mixed plaque decreased from 69.8% (40 keV) to 56.3% (140 keV), and for noncalcified plaque was 46.6% at 40 keV and 54.6% at 140 keV. PDS showed lowest bias for calcified plaque at 100 keV (bias, 17.2%), for mixed plaque at 140 keV (bias, 5.0%), and for noncalcified plaque at 40 keV (bias, -0.5%). Blooming artifacts decreased for calcified plaque from 78.4% (40 keV) to 48.6% (140 keV) and for mixed plaque from 73.1% (40 keV) to 44.7% (140 keV). CONCLUSION. For calcified and mixed plaque, stenosis severity measurements and blooming artifacts decreased at increasing VMI reconstruction levels. CLINICAL IMPACT. PCD CT with VMI reconstruction helps overcome current limitations in stenosis quantification on coronary CTA.


Assuntos
Estenose Coronária , Placa Aterosclerótica , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Estudos Retrospectivos , Constrição Patológica , Tomografia Computadorizada por Raios X/métodos , Estenose Coronária/diagnóstico por imagem
8.
Inn Med (Heidelb) ; 2024 Jan 04.
Artigo em Alemão | MEDLINE | ID: mdl-38175281

RESUMO

The case of a 78-year-old female presenting to the authors' department with heart failure with dyspnea at minimal exertion (NYHA III) as well as hypertensive blood pressure and hypokalaemia is reported. Laboratory workup showed hypercortisolism. Further workup, including imaging studies and selective catheterisation of the inferior petrosal sinus, resulted in the diagnosis of Cushing's disease caused by a pituitary microadenoma.

9.
J Biomech ; 163: 111922, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38220500

RESUMO

Musculoskeletal (MSK) models offer great potential for predicting the muscle forces required to inform more detailed simulations of vertebral endplate loading in adolescent idiopathic scoliosis (AIS). In this work, simulations based on static optimization were compared with in vivo measurements in two AIS patients to determine whether computational approaches alone are sufficient for accurate prediction of paraspinal muscle activity during functional activities. We used biplanar radiographs and marker-based motion capture, ground reaction force, and electromyography (EMG) data from two patients with mild and moderate thoracolumbar AIS (Cobb angles: 21° and 45°, respectively) during standing while holding two weights in front (reference position), walking, running, and object lifting. Using a fully automated approach, 3D spinal shape was extracted from the radiographs. Geometrically personalized OpenSim-based MSK models were created by deforming the spine of pre-scaled full-body models of children/adolescents. Simulations were performed using an experimentally controlled backward approach. Differences between model predictions and EMG measurements of paraspinal muscle activity (both expressed as a percentage of the reference position values) at three different locations around the scoliotic main curve were quantified by root mean square error (RMSE) and cross-correlation (XCorr). Predicted and measured muscle activity correlated best for mild AIS during object lifting (XCorr's ≥ 0.97), with relatively low RMSE values. For moderate AIS as well as the walking and running activities, agreement was lower, with XCorr reaching values of 0.51 and comparably high RMSE values. This study demonstrates that static optimization alone seems not appropriate for predicting muscle activity in AIS patients, particularly in those with more than mild deformations as well as when performing upright activities such as walking and running.


Assuntos
Cifose , Escoliose , Criança , Humanos , Adolescente , Escoliose/diagnóstico por imagem , Eletromiografia , Músculos Paraespinais/diagnóstico por imagem , Coluna Vertebral
10.
Ann Thorac Surg ; 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38286206

RESUMO

The Society of Thoracic Surgeons 2023 clinical practice guidelines for the surgical management of atrial fibrillation incorporate the most recent evidence for surgical ablation and left atrial appendage occlusion in different clinical scenarios. Substantial new evidence regarding the risks and benefits of surgical left atrial appendage occlusion and the long-term benefits of surgical ablation has been produced in the last five years. In comparison to the 2017 clinical practice guideline, the current update has an emphasis on surgical ablation in first-time, non-emergent cardiac surgery and its long-term benefits, an extension of the recommendation to perform surgical ablation in all patients with atrial fibrillation undergoing first-time, non-emergent cardiac surgery and a new class I recommendation for left atrial appendage occlusion in all patients with atrial fibrillation undergoing first-time, non-emergent cardiac surgery. Further guidance is provided for patients with structural heart disease and atrial fibrillation being considered for transcatheter valve repair or replacement, as well as patients in need of isolated left atrial appendage management who are not candidates for surgical ablation. The importance of a multidisciplinary team assessment, treatment planning, and long-term follow-up are reiterated in this clinical practice guideline with a class I recommendation, along with the other recommendations from the 2017 guidelines which remained unchanged in their class of recommendation and level of evidence.

11.
Emerg Radiol ; 31(1): 63-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194212

RESUMO

PURPOSE: Assessing the diagnostic performance and supplementary value of whole-body computed tomography scout view (SV) images in the detection of thoracolumbar spine injuries in early resuscitation phase and identifying frequent image quality confounders. METHODS: In this retrospective database analysis at a tertiary emergency center, three blinded senior experts independently assessed SV to detect thoracolumbar spine injuries. The findings were categorized according to the AO Spine classification system. Confounders impacting SV image quality were identified. The suspected injury level and severity, along with the confidence level, were indicated. Diagnostic performance was estimated using the caret package in R programming language. RESULTS: We assessed images of 199 patients, encompassing 1592 vertebrae (T10-L5), and identified 56 spinal injuries (3.5%). Among the 199 cases, 39 (19.6%) exhibited at least one injury in the thoracolumbar spine, with 12 (6.0%) of them displaying multiple spinal injuries. The pooled sensitivity, specificity, and accuracy were 47%, 99%, and 97%, respectively. All experts correctly identified the most severe injury of AO type C. The most common image confounders were medical equipment (44.6%), hand position (37.6%), and bowel gas (37.5%). CONCLUSION: SV examination holds potential as a valuable supplementary tool for thoracolumbar spinal injury detection when CT reconstructions are not yet available. Our data show high specificity and accuracy but moderate sensitivity. While not sufficient for standalone screening, reviewing SV images expedites spinal screening in mass casualty incidents. Addressing modifiable factors like medical equipment or hand positioning can enhance SV image quality and assessment.


Assuntos
Traumatismo Múltiplo , Fraturas da Coluna Vertebral , Traumatismos da Coluna Vertebral , Humanos , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/métodos , Traumatismos da Coluna Vertebral/diagnóstico por imagem
12.
Global Spine J ; 14(2_suppl): 163S-172S, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36592140

RESUMO

STUDY DESIGN: This study constitutes a systematic review of the literature. OBJECTIVE: The aim of this study was to identify and present all available studies that report on the costs of osteobiologics used in anterior cervical discectomy and fusion (ACDF). METHODS: The literature was systematically reviewed to identify studies with specific inclusion criteria: (1) randomized controlled trials and observational studies, (2) in adult patients, (3) with herniated disc(s) or degenerative cervical spine disease, (4) reporting on either direct or indirect costs of using specific osteobiologics in an ACDF operation. (5) Only studies in English were included. The quality of the included studies was assessed using the MINORS and RoB 2.0 tools. RESULTS: Overall, 14 articles were included; one randomized controlled trial and 13 observational studies. The most commonly used osteobiologics other than autograft/iliac crest bone graft (ICBG) were allograft and bone morphogenetic protein (BMP). None of the studies was reported to be industry-supported. There was considerable heterogeneity on the reported costs. Overall, most studies reported on surgery-related costs, such as anesthesia, operating room, surgical materials and surgeon's fee. Only two studies, both using allograft, reported the exact cost of the osteobiologic used (450 GBP, $700). Some of the studies reported on the cost of care during hospitalization for the surgical operation, such as radiology studies, emergency room costs, cardiologic evaluation, laboratory studies, pharmacy costs, and room costs. Only a few studies reported on the cost of follow-up, reoperation, and physical therapy and rehabilitation. CONCLUSION: Based on the data of this current systematic review, no recommendations can be made regarding the cost-effectiveness of using osteobiologics in ACDF. Given the high costs of osteobiologics, this remains a topic of importance. The design of future studies on the subject should include cost effectiveness.

13.
Eur J Nucl Med Mol Imaging ; 51(4): 1185-1193, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38038755

RESUMO

PURPOSE: To assess early tumor response with quantitated SPECT/CT and to correlate it with clinical outcome in metastatic castration-resistant prostate cancer (mCRPC) patients treated with 177Lutetium-PSMA I&T therapy. METHODS: Single-center, observational study, part of the prospective Swiss national cancer registry study investigating the safety and efficacy of [177Lu]Lu-PSMA I&T (EKNZ: 2021-01271) in mCRPC patients treated with at least two cycles of [177Lu]Lu-PSMA I&T 6-weekly. After the first and second cycle quantitated SPECT/CT (Symbia Intevo, Siemens) was acquired 48 h after injection (three fields of view from head to thigh, 5 s/frame) and reconstructed using xQuant® (48i, 1 s, 10-mm Gauss). Image analysis: The PSMA-positive total tumor volumes (TTV) were semi-automatically delineated using a SUV threshold of 3 with MIMencore® (version 7.1.3, Medical Image Merge Software Inc.). Changes in TTV, highest tumor SUVmax, and total tumor SUVmean between cycles 1 and 2 were calculated and grouped into a) stable or decrease and b) increase. Serum PSA levels were assessed at each therapy cycle and at follow-up until progression or death. Changes in TTV, PSA, SUVmax, and SUVmean were correlated with PSA-progression-free survival (PSA-PFS) and the overall survival (OS) using the Kaplan-Meier methodology (log-rank test). RESULTS: Between 07/2020 and 04/2022, 111 patients were screened and 73 finally included in the data analysis. The median follow-up was 8.9 months (range 1.4-26.6 months). Stable or decreased TTV at cycle 2 was associated with longer OS (hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.09-0.86, p < 0.01). Similar, stable, or decreased PSA was associated with longer OS (HR 0.21; CI 0.07-0.62, p < 0.01) and PSA-PFS (HR 0.34; 95% CI 0.16-0.72, p < 0.01). Combining TTV and PSA will result in an augmented prognostic value for OS (HR 0.09; CI 0.01-0.63; p < 0.01) and for PSA-PFS (HR 0.11; CI 0.02-0.68; p < 0.01). A reduction of SUVmax or SUVmean was not prognostically relevant, neither for OS (p 0.88 and 0.7) nor for PSA-PFS (p 0.73 and 0.62, respectively). CONCLUSION: Six weeks after initiating [177Lu]Lu-PSMA I&T, TTV and serum PSA appear to be good prognosticators for OS. Combined together, TTV + PSA change demonstrates augmented prognostic value and can better predict PSA-PFS. Larger studies using TTV change prospectively as an early-response biomarker are warranted for implementing management change towards a more personalized clinical practice.


Assuntos
Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração , Ureia/análogos & derivados , Masculino , Humanos , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Suíça , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Lutécio/uso terapêutico , Dipeptídeos/uso terapêutico , Estudos Retrospectivos
14.
Ann Thorac Surg ; 117(2): 260-270, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38040323

RESUMO

The Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database is one of the largest and most comprehensive contemporary clinical databases in use. It now contains >9 million procedures from 1010 participants and 3651 active surgeons. Using audited data collection, it has provided the foundation for multiple risk models, performance metrics, health policy decisions, and a trove of research studies to improve the care of patients in need of cardiac surgical procedures. This annual report provides an update on the current status of the database and summarizes the development of new risk models and the STS Online Risk Calculator. Further, it provides insights into current practice patterns, such as the change in the demographics among patients undergoing aortic valve replacement, the use of minimally invasive techniques for valve and bypass surgery, or the adoption of surgical ablation and left atrial appendage ligation among patients with atrial fibrillation. Lastly, an overview of the research conducted using the STS Adult Cardiac Surgery Database and future directions for the database are provided.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgiões , Cirurgia Torácica , Adulto , Humanos , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Bases de Dados Factuais , Sociedades Médicas
16.
J Thorac Imaging ; 39(2): 127-135, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982533

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Feminino , Masculino , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração , Função Ventricular Esquerda
17.
Diagnostics (Basel) ; 13(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38066763

RESUMO

Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.

18.
Contemp Clin Trials ; 135: 107384, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37949165

RESUMO

OBJECTIVES: Medical imaging plays an essential role in healthcare. As a diagnostic test, imaging is prone to substantial overuse and potential overdiagnosis, with dire consequences to patient outcomes and health care costs. Clinical decision support systems (CDSSs) were developed to guide referring physicians in making appropriate imaging decisions. This study will evaluate the effect of implementing a CDSS (ESR iGuide) with versus without active decision support in a physician order entry on the appropriate use of imaging tests and ordering behaviour. METHODS: A protocol for a multi-center cluster-randomized trial with departments acting as clusters, combined with a before-after-revert design. Four university hospitals with eight participating departments each for a total of thirty-two clusters will be included in the study. All departments start in control condition with structured data entry of the clinical indication and tracking of the imaging exams requested. Initially, the CDSS is implemented and all physicians remain blinded to appropriateness scores based on the ESR imaging referral guidelines. After randomization, half of the clusters switch to the active intervention of decision support. Physicians in the active condition are made aware of the categorization of their requests as appropriate, under certain conditions appropriate, or inappropriate, and appropriate exams are suggested. Physicians may change their requests in response to feedback. In the revert condition, active decision support is removed to study the educational effect. RESULTS/CONCLUSIONS: The main outcome is the proportion of inappropriate diagnostic imaging exams requested per cluster. Secondary outcomes are the absolute number of imaging exams, radiation from diagnostic imaging, and medical costs. TRIAL REGISTRATION NUMBER: Approval from the Medical Ethics Review Committee was obtained under protocol numbers 20-069 (Augsburg), B 238/21 (Kiel), 20-318 (Lübeck) and 2020-15,125 (Mainz). The trial is registered in the ClinicalTrials.gov register under registration number NCT05490290.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Humanos , Diagnóstico por Imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
19.
BMC Med Imaging ; 23(1): 187, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968580

RESUMO

PURPOSE: Kidney volume is important in the management of renal diseases. Unfortunately, the currently available, semi-automated kidney volume determination is time-consuming and prone to errors. Recent advances in its automation are promising but mostly require contrast-enhanced computed tomography (CT) scans. This study aimed at establishing an automated estimation of kidney volume in non-contrast, low-dose CT scans of patients with suspected urolithiasis. METHODS: The kidney segmentation process was automated with 2D Convolutional Neural Network (CNN) models trained on manually segmented 2D transverse images extracted from low-dose, unenhanced CT scans of 210 patients. The models' segmentation accuracy was assessed using Dice Similarity Coefficient (DSC), for the overlap with manually-generated masks on a set of images not used in the training. Next, the models were applied to 22 previously unseen cases to segment kidney regions. The volume of each kidney was calculated from the product of voxel number and their volume in each segmented mask. Kidney volume results were then validated against results semi-automatically obtained by radiologists. RESULTS: The CNN-enabled kidney volume estimation took a mean of 32 s for both kidneys in a CT scan with an average of 1026 slices. The DSC was 0.91 and 0.86 and for left and right kidneys, respectively. Inter-rater variability had consistencies of ICC = 0.89 (right), 0.92 (left), and absolute agreements of ICC = 0.89 (right), 0.93 (left) between the CNN-enabled and semi-automated volume estimations. CONCLUSION: In our work, we demonstrated that CNN-enabled kidney volume estimation is feasible and highly reproducible in low-dose, non-enhanced CT scans. Automatic segmentation can thereby quantitatively enhance radiological reports.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Cintilografia , Rim/diagnóstico por imagem , Automação , Processamento de Imagem Assistida por Computador/métodos
20.
Eur Radiol Exp ; 7(1): 59, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37875769

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: • Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. • Differences in VMI lead to decreased reproducibility for radiomic features. • VMI ≥ 90 keV increased the reproducibility of the radiomic features.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Miocárdio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...