Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Assist Technol ; 34(5): 611-618, 2022 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-33760680

RESUMO

Low vision care and rehabilitation is often limited by access to assistive devices, especially in low-resourced countries, due to their high cost and unavailability. Smartphones have the potential to serve as an alternative assistive device for people living with severe visual impairment and blindness (SVIB). This study aims to investigate the use of smartphones among people living with SVIB. The study was a cross-sectional study of 166 people living with SVIB in a low resourced setting. The participants were recruited from two tertiary institutions and four eye care facilities. A questionnaire was administered to all respondents and for those who could not read prints they were read out to them and their responses recorded. The majority of respondents (n = 88, 53.1%) either had no phone or used a basic phone. The prevalence of smartphone usage among people living with SVIB was found to be 46.90% (n = 78). Most respondents use their smartphones to interact on social media [n = 75 (96%)] and web browsing [n = 69,92%]. The most frequently demanded [n = 22 (44%)] smartphone functionality by the respondents was the image and color description feature. Most participants were unaware that 90% of their functionality demands already existed and were compatible with current smartphones. A significant number of people living with SVIB in this study used smartphones; however, most users are unaware of its full functionality and assistive capabilities.


Assuntos
Smartphone , Baixa Visão , Cegueira , Estudos Transversais , Humanos , Transtornos da Visão
2.
J Occup Health ; 63(1): e12279, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34529317

RESUMO

OBJECTIVE: Glare caused by the headlights of on-coming vehicles risk safe driving at night. The study aimed to determine the relationship between glare exposure and nighttime driving performance among commercial drivers in Ghana. METHODS: This cross-sectional study involved commercial drivers with complaints of nighttime driving difficulties (N = 80; mean age = 41.5 ± 11.1 years). A questionnaire was used to investigate nighttime driving performance following glare exposure. We measured contrast sensitivity and visual acuity under photopic conditions. With an experimental setup in a mesopic setting, we measured visual acuity with and without glare exposure. The difference between the two mesopic visual acuities was quantified as disability glare index. With the same setup, photostress recovery time was also measured. Regression analyses were used to determine the relationship between nighttime driving performance score and the measures taken in both photopic and mesopic settings. RESULTS: The average nighttime driving performance score was 47.8 ± 17.5. Driving performance was negatively correlated with all variables (R = -0.87 to -0.30, all p < .01), except contrast sensitivity (R = 0.74, p < .01). A multiple linear regression showed that the model with all variables explained 83.8% of the variance, but only disability glare index was a significant predictor of nighttime driving performance following glare exposure (standardized B = -0.61, p < .01). CONCLUSION: Our results show that the change in mesopic visual acuities following glare can predict nighttime driving performance. This measure can be incorporated into the assessment of driving fitness by licensing departments to evaluate whether a person can drive safely at night amidst glare exposure.


Assuntos
Condução de Veículo , Ofuscação/efeitos adversos , Visão Ocular , Acuidade Visual , Adulto , Estudos Transversais , Gana , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
3.
J Ophthalmol ; 2020: 7150673, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32104596

RESUMO

PURPOSE: To determine normative values of retinal nerve fibre layer thickness (RNFL) and optic nerve head (ONH) parameters and their association with routine clinical tests such as refractive error (RE), stereoacuity (SA), and contrast sensitivity (CS) in an African population. METHODS: In a cross-sectional observational study, 100 normal subjects aged 20 to 78 years were evaluated using the Cirrus HD-OCT 5000 and matched with 200 glaucoma patients. RESULTS: Average (±SD) RNFL thickness for normal subjects was found to be 102.37 ± 7.45 (range, 82-119 microns) compared with 90.74 ± 14.50 found for glaucoma subjects. Females had higher average RNFL values (104.84 ± 6.90) compared with males (99.80 ± 7.18). Significant associations were calculated between quadrant RNFL thickness and SA, SE, and CS (all p < 0.05). The mean cup to disc ratio (CDR) was 0.49 ± 0.12, and mean optic disc area (DA) was 2.08 mm2 ± 0.40. Smaller DA was recorded for participants aged 60+ years (1.86 ± 0.25), followed by 40-59 age group (2.01 ± 0.41) and then 20-39 age group (2.19 ± 0.41). Significant associations were calculated between SA and ONH parameters, except rim area (all p < 0.05). The mean cup to disc ratio (CDR) was 0.49 ± 0.12, and mean optic disc area (DA) was 2.08 mm2 ± 0.40. Smaller DA was recorded for participants aged 60+ years (1.86 ± 0.25), followed by 40-59 age group (2.01 ± 0.41) and then 20-39 age group (2.19 ± 0.41). Significant associations were calculated between SA and ONH parameters, except rim area (all p < 0.05). The mean cup to disc ratio (CDR) was 0.49 ± 0.12, and mean optic disc area (DA) was 2.08 mm2 ± 0.40. Smaller DA was recorded for participants aged 60+ years (1.86 ± 0.25), followed by 40-59 age group (2.01 ± 0.41) and then 20-39 age group (2.19 ± 0.41). Significant associations were calculated between SA and ONH parameters, except rim area (all. CONCLUSION: RNFL thickness in healthy black Ghanaian population was significantly higher than that reported in other races. The values and associations reported in this study can inform clinical decision on the normal variation in RNFL and optic disc parameters.

4.
J Environ Public Health ; 2019: 3813298, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31428165

RESUMO

Purpose: The aim of this study was to analyse eye health delivery in Ghana and examine the progress towards achieving VISION 2020 indicator targets. Methods: This descriptive cross-sectional study was conducted between October 2017 and May 2018. It used a mixed method approach including desk-based reviews, a questionnaire-based survey of eye facilities in Ghana, and interviews with eye health system stakeholders to collect information on eye health delivery in facilities owned by the Ghana Health Service (GHS), quasigovernmental bodies (security agencies), and Christian Association of Ghana (CHAG). The information was benchmarked against the World Health Organization (WHO) targets for achieving the goals of VISION 2020. Results: The magnitude of blindness and moderate to severe visual impairment (without pinhole) was 0.9% and 3.0%, respectively. The number of ophthalmologists available at the country level was 80.6% of the VISION 2020 target with optometrists and ophthalmic nurses exceeding targets for VISION 2020. The distribution of human resources was heavily skewed towards two out of the 10 regions in Ghana. Cataract surgical rate was low and met 25% of the WHO target. Basic equipment for refraction was available in the majority of facilities; however, there was a general lack of specialised eye care equipment across the country. Comparatively, CHAG facilities were better equipped than GHS facilities at the same level. Conclusion: The Government of Ghana should revitalize the goals of VISION 2020 beyond the year 2020 and spearhead a concerted effort to ensure equitable distribution of human and infrastructural resources across the country.


Assuntos
Atenção à Saúde/estatística & dados numéricos , Visão Ocular , Cegueira/epidemiologia , Extração de Catarata/estatística & dados numéricos , Estudos Transversais , Atenção à Saúde/organização & administração , Gana/epidemiologia , Pesquisas sobre Atenção à Saúde , Mão de Obra em Saúde/estatística & dados numéricos , Humanos , Oftalmologia/estatística & dados numéricos , Optometria/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA