Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Biomech (Bristol, Avon) ; 72: 179-185, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31895995

RESUMO

BACKGROUND: Earlier clinical reports have identified femoral anteversion as a factor associated with developmental dysplasia of the hip. This study investigates the biomechanical influence of femoral anteversion on severe dislocations and its effect on hip reduction using the Pavlik harness. METHODS: A computational model of an infant lower-extremity, representing a ten-week old female was used to analyze the biomechanics of anteversion angles ranging from 30° to 70° when severe dislocation was being treated with the Pavlik harness. Specifically, the effects and relationships between muscle passive response and femoral anteversion angle were investigated over a range of hip abduction and external rotation. FINDINGS: Results of this study suggest that increased femoral anteversion may decrease the success rate for treatment of high-grade developmental dysplasia of the hip when using the Pavlik harness. However, hip external rotation and decreased abduction in the harness may facilitate initial reduction in these cases. INTERPRETATION: This biomechanical study may help explain why dissections of newborn specimen with developmental dysplasia of the hip have shown normal distribution of femoral anteversion in contrast to studies of patients requiring surgery where greater frequency of increased femoral anteversion has been reported. This study also suggests that adjusting the Pavlik harness to increase external hip rotation and decrease hip abduction may facilitate initial reduction for severe dislocations with increased femoral anteversion.


Assuntos
Displasia do Desenvolvimento do Quadril/fisiopatologia , Fenômenos Mecânicos , Fenômenos Biomecânicos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Rotação , Fatores de Tempo
2.
J Orthop Res ; 35(8): 1799-1805, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27764890

RESUMO

This study utilized a computational biomechanical model and applied the least energy path principle to investigate two pathways for closed reduction of high grade infantile hip dislocation. The principle of least energy when applied to moving the femoral head from an initial to a final position considers all possible paths that connect them and identifies the path of least resistance. Clinical reports of severe hip dysplasia have concluded that reduction of the femoral head into the acetabulum may occur by a direct pathway over the posterior rim of the acetabulum when using the Pavlik harness, or by an indirect pathway with reduction through the acetabular notch when using the modified Hoffman-Daimler method. This computational study also compared the energy requirements for both pathways. The anatomical and muscular aspects of the model were derived using a combination of MRI and OpenSim data. Results of this study indicate that the path of least energy closely approximates the indirect pathway of the modified Hoffman-Daimler method. The direct pathway over the posterior rim of the acetabulum required more energy for reduction. This biomechanical analysis confirms the clinical observations of the two pathways for closed reduction of severe hip dysplasia. The path of least energy closely approximated the modified Hoffman-Daimler method. Further study of the modified Hoffman-Daimler method for reduction of severe hip dysplasia may be warranted based on this computational biomechanical analysis. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1799-1805, 2017.


Assuntos
Luxação Congênita de Quadril/terapia , Modelos Biológicos , Humanos , Recém-Nascido
3.
J Biomech ; 48(10): 2026-33, 2015 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-25957995

RESUMO

A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation.


Assuntos
Luxação Congênita de Quadril/patologia , Quadril/patologia , Fenômenos Mecânicos , Modelagem Computacional Específica para o Paciente , Fenômenos Biomecânicos , Feminino , Fêmur/diagnóstico por imagem , Quadril/diagnóstico por imagem , Quadril/fisiopatologia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/fisiopatologia , Humanos , Lactente , Recém-Nascido , Extremidade Inferior/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X
4.
J Biomech ; 46(9): 1501-7, 2013 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-23631856

RESUMO

Biomechanical factors influencing the reduction of dislocated hips with the Pavlik harness in patients of Developmental Dysplasia of the Hip (DDH) were studied using a three-dimensional computer model simulating hip reduction dynamics in (1) subluxated and (2) fully dislocated hip joints. Five hip adductor muscles were identified as key mediators of DDH prognosis, and the non-dimensional force contribution of each in the direction necessary to achieve concentric hip reductions was determined. Results point to the adductor muscles as mediators of subluxated hip reductions, as their mechanical action is a function of the degree of hip dislocation. For subluxated hips in abduction and flexion, the Pectineus, Adductor Brevis, Adductor Longus, and proximal Adductor Magnus contribute positively to reduction, while the rest of the Adductor Magnus contributes negatively. In full dislocations all muscles contribute detrimentally to reduction, elucidating the need for traction to reduce Graf IV type dislocations. Reduction of dysplastic hips was found to occur in two distinct phases: (a) release phase and (b) reduction phase.


Assuntos
Luxação Congênita de Quadril/terapia , Modelos Teóricos , Restrição Física/instrumentação , Simulação por Computador , Feminino , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/fisiopatologia , Humanos , Lactente , Extremidade Inferior/fisiopatologia , Músculo Esquelético/fisiopatologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA