Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Sci Rep ; 14(1): 8253, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589478

RESUMO

This work presents a deep learning approach for rapid and accurate muscle water T2 with subject-specific fat T2 calibration using multi-spin-echo acquisitions. This method addresses the computational limitations of conventional bi-component Extended Phase Graph fitting methods (nonlinear-least-squares and dictionary-based) by leveraging fully connected neural networks for fast processing with minimal computational resources. We validated the approach through in vivo experiments using two different MRI vendors. The results showed strong agreement of our deep learning approach with reference methods, summarized by Lin's concordance correlation coefficients ranging from 0.89 to 0.97. Further, the deep learning method achieved a significant computational time improvement, processing data 116 and 33 times faster than the nonlinear least squares and dictionary methods, respectively. In conclusion, the proposed approach demonstrated significant time and resource efficiency improvements over conventional methods while maintaining similar accuracy. This methodology makes the processing of water T2 data faster and easier for the user and will facilitate the utilization of the use of a quantitative water T2 map of muscle in clinical and research studies.


Assuntos
Algoritmos , Aprendizado Profundo , Água , Calibragem , Imageamento por Ressonância Magnética/métodos , Músculos/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Encéfalo
3.
Appl Sci (Basel) ; 12(7)2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36032414

RESUMO

In vivo cardiac diffusion tensor imaging (cDTI) data were acquired in swine subjects six to ten weeks post-myocardial infarction (MI) to identify microstructural-based biomarkers of MI. Diffusion tensor invariants, diffusion tensor eigenvalues, and radial diffusivity (RD) are evaluated in the infarct, border, and remote myocardium, and compared with extracellular volume fraction (ECV) and native T1 values. Additionally, to aid the interpretation of the experimental results, the diffusion of water molecules was numerically simulated as a function of ECV. Finally, findings based on in vivo measures were confirmed using higher-resolution and higher signal-to-noise data acquired ex vivo in the same subjects. Mean diffusivity, diffusion tensor eigenvalues, and RD increased in the infarct and border regions compared to remote myocardium, while fractional anisotropy decreased. Secondary (e2) and tertiary (e3) eigenvalues increased more significantly than the primary eigenvalue in the infarct and border regions. These findings were confirmed by the diffusion simulations. Although ECV presented the largest increase in infarct and border regions, e2, e3, and RD increased the most among non-contrast-based biomarkers. RD is of special interest as it summarizes the changes occurring in the radial direction and may be more robust than e2 or e3 alone.

4.
Diagnostics (Basel) ; 12(4)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35453925

RESUMO

A super-resolution (SR) technique is proposed for imaging myocardial fiber architecture with cardiac magnetic resonance. Images were acquired with a motion-compensated cardiac diffusion tensor imaging (cDTI) sequence. The heart left ventricle was covered with three stacks of thick slices, in short axis, horizontal and vertical long axes orientations, respectively. The three low-resolution stacks (2 × 2 × 8 mm3) were combined into an isotropic volume (2 × 2 × 2 mm3) by a super-resolution reconstruction. For in vivo measurements, each slice was acquired during a breath-hold period. Bulk motion was corrected by optimizing a similarity metric between intensity profiles from all intersecting slices in the dataset. The benefit of the proposed approach was evaluated using a numerical heart phantom, a physical helicoidal phantom with artificial fibers, and six healthy subjects. The SR technique showed improved results compared to the native scans, in terms of image quality and cDTI metrics. In particular, the myocardial helix angle (HA) was more accurately estimated in the physical phantom (HA = 41.5° ± 1.1°, with the ground truth being 42.0°). In vivo, it resulted in a sharper rate of change of HA across the myocardial wall (-0.993°/% ± 0.007°/% against -0.873°/% ± 0.010°/%).

5.
Diagn Interv Imaging ; 103(9): 433-439, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35410799

RESUMO

PURPOSE: Characterizing orbital lesions remains challenging with imaging. The purpose of this study was to compare 3 Tesla (T) to 7 T magnetic resonance imaging (MRI) for characterizing orbital lesions. MATERIALS AND METHODS: This prospective single-center study enrolled participants presenting with orbital lesions from May to October 2019, who underwent both 7 T and 3 T MRI examinations. Two neuroradiologists, blinded to all data, read both datasets independently and randomly. They assessed general characteristics of each orbital lesion as well as image quality and presence of artifacts. Comparison between both datasets was made using Fisher exact test. RESULTS: Seven patients (4 women, 3 men) with a median age of 52 years were enrolled. Orbital lesion conspicuity was better scored at 7 T compared to 3 T MRI, with 3/7 lesions (43%) scored as very conspicuous at 7 T compared to 0/7 lesion (0%) at 3 T, although the difference was not significant (P = 0.16). Delineation of lesion margins was better scored at 7 T compared to 3 T with 3/7 lesions (43%) scored as very well delineated on 7 T compared to 0/7 lesions (0%) at 3 T, although the difference was not significant (P = 0.34). Details of internal structure were better assessed at 7 T compared to 3 T, with 4/7 lesions (57%) displaying numerous internal details compared to 0/7 lesions (0%) at 3 T (P = 0.10). Internal microvessels were visible in 3/7 lesions (43%) at 7 T compared to 0/7 lesions (0%) at 3 T (P = 0.19). CONCLUSION: Although no significant differences were found between 7 T and 3 T MRI, assumably due to a limited number of patients, our study suggests that 7 Tesla MRI might help improve the characterization of orbital lesions. However, further studies with more patients are needed.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Front Cardiovasc Med ; 9: 790551, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35321109

RESUMO

Objectives: The effects of ultra-distance on cardiac remodeling and fibrosis are unclear. Moreover, there are no data reporting the kinetics of cardiac alterations throughout the event and during recovery. Our aim was to investigate the kinetics of biological markers including new cardiac fibrosis biomarkers suppression of tumorigenicity 2 (ST2) and galectin-3 (Gal-3) during and after an extreme mountain ultramarathon. Methods: Fifty experienced runners participating in one of the most challenging mountain ultramarathons (330 km, D+ 25,000 m) were enrolled in our study. Blood samples were collected at four time points: before (Pre-), at 148 km (Mid-), at the finish line (Post-), and 3 days after the recovery period (Recov-). Results: The cardiac fibrosis biomarkers (ST2 and Gal-3) increased from Pre- to Mid-. During the second half, ST2 remained higher than pre-values as opposed to Gal-3. Necrosis, ischemia, and myocyte injury biomarkers increased until Mid- then decreased but remained higher at Recov- than Pre-values. Oxidative stress appeared at Mid-. Lipid peroxides remained higher at Recov- compared to Pre-. The maximal value in most of these biomarkers was observed at Mid- and not at Post-. Conclusions: The present study supports biphasic kinetics of cardiac fibrosis biomarkers, with a relative recovery during the second half of the event that seems specific to this extreme event. Overall, performing at such an extreme ultramarathon seems less deleterious for the heart than shorter events.

7.
NMR Biomed ; 35(6): e4685, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34967060

RESUMO

Cardiac diffusion tensor imaging (DTI) is an emerging technique for the in vivo characterisation of myocardial microstructure, and there is a growing need for its validation and standardisation. We sought to establish the accuracy, precision, repeatability and reproducibility of state-of-the-art pulse sequences for cardiac DTI among 10 centres internationally. Phantoms comprising 0%-20% polyvinylpyrrolidone (PVP) were scanned with DTI using a product pulsed gradient spin echo (PGSE; N = 10 sites) sequence, and a custom motion-compensated spin echo (SE; N = 5) or stimulated echo acquisition mode (STEAM; N = 5) sequence suitable for cardiac DTI in vivo. A second identical scan was performed 1-9 days later, and the data were analysed centrally. The average mean diffusivities (MDs) in 0% PVP were (1.124, 1.130, 1.113) x 10-3  mm2 /s for PGSE, SE and STEAM, respectively, and accurate to within 1.5% of reference data from the literature. The coefficients of variation in MDs across sites were 2.6%, 3.1% and 2.1% for PGSE, SE and STEAM, respectively, and were similar to previous studies using only PGSE. Reproducibility in MD was excellent, with mean differences in PGSE, SE and STEAM of (0.3 ± 2.3, 0.24 ± 0.95, 0.52 ± 0.58) x 10-5  mm2 /s (mean ± 1.96 SD). We show that custom sequences for cardiac DTI provide accurate, precise, repeatable and reproducible measurements. Further work in anisotropic and/or deforming phantoms is warranted.


Assuntos
Imagem de Tensor de Difusão , Coração , Anisotropia , Imagem de Tensor de Difusão/métodos , Coração/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
8.
Funct Imaging Model Heart ; 12738: 137-147, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34585174

RESUMO

Cardiac diffusion tensor magnetic resonance imaging (cDTI) allows estimating the aggregate cardiomyocyte architecture in healthy subjects and its remodeling as a result of cardiac disease. In this study, cDTI was used to quantify microstructural changes occurring in swine (N=7) six to ten weeks after myocardial infarction. Each heart was extracted and imaged ex vivo with 1mm isotropic spatial resolution. Microstructural changes were quantified in the border zone and infarct region by comparing diffusion tensor invariants - fractional anisotropy (FA), mode, and mean diffusivity (MD) - radial diffusivity, and diffusion tensor eigenvalues with the corresponding values in the remote myocardium. MD and radial diffusivity increased in the infarct and border regions with respect to the remote myocardium (p<0.01). In contrast, FA and mode decreased in the infarct and border regions (p<0.01). Diffusion tensor eigenvalues also increased in the infarct and border regions, with a larger increase in the secondary and tertiary eigenvalues.

9.
Front Neurol ; 12: 608549, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33658976

RESUMO

Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessment of non-contracted musculature, therefore providing limited insight into muscle contraction mechanisms and contraction abnormalities. In this study, we propose the use of an oscillating gradient spin echo (OGSE) diffusion encoding strategy for DTI measurements to mitigate the effect of signal voids in contracted muscle and to obtain reliable diffusivity values. Two OGSE sequences with encoding frequencies of 25 and 50 Hz were tested in the lower leg of five healthy volunteers with relaxed musculature and during active dorsiflexion and plantarflexion, and compared with a conventional PGSE approach. A significant reduction of areas of signal voids using OGSE compared with PGSE was observed in the tibialis anterior for the scans obtained in active dorsiflexion and in the soleus during active plantarflexion. The use of PGSE sequences led to unrealistically elevated axial diffusivity values in the tibialis anterior during dorsiflexion and in the soleus during plantarflexion, while the corresponding values obtained using the OGSE sequences were significantly reduced. Similar findings were seen for radial diffusivity, with significantly higher diffusivity measured in plantarflexion in the soleus muscle using the PGSE sequence. Our preliminary results indicate that DTI with OGSE diffusion encoding is feasible in human musculature and allows to quantitatively assess diffusion properties in actively contracting skeletal muscle. OGSE holds great potential to assess microstructural changes occurring in the skeletal muscle during contraction, and for non-invasive assessment of contraction abnormalities in patients with muscle diseases.

10.
Magn Reson Med ; 86(1): 277-292, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33619807

RESUMO

PURPOSE: Myofiber strain, Eff , is a mechanistically relevant metric of cardiac cell shortening and is expected to be spatially uniform in healthy populations, making it a prime candidate for the evaluation of local cardiomyocyte contractility. In this study, a new, efficient pipeline was proposed to combine microstructural cDTI and functional DENSE data in order to estimate Eff in vivo. METHODS: Thirty healthy volunteers were scanned with three long-axis (LA) and three short-axis (SA) DENSE slices using 2D displacement encoding and one SA slice of cDTI. The total acquisition time was 11 minutes ± 3 minutes across volunteers. The pipeline first generates 3D SA displacements from all DENSE slices which are then combined with cDTI data to generate a cine of myofiber orientations and compute Eff . The precision of the post-processing pipeline was assessed using a computational phantom study. Transmural myofiber strain was compared to circumferential strain, Ecc , in healthy volunteers using a Wilcoxon sign rank test. RESULTS: In vivo, computed Eff was found uniform transmurally compared to Ecc (-0.14[-0.15, -0.12] vs -0.18 [-0.20, -0.16], P < .001, -0.14 [-0.16, -0.12] vs -0.16 [-0.17, -0.13], P < .001 and -0.14 [-0.16, -0.12] vs Ecc_C = -0.14 [-0.15, -0.11], P = .002, Eff_C vs Ecc_C in the endo, mid, and epi layers, respectively). CONCLUSION: We demonstrate that it is possible to measure in vivo myofiber strain in a healthy human population in 10 minutes per subject. Myofiber strain was observed to be spatially uniform in healthy volunteers making it a potential biomarker for the evaluation of local cardiomyocyte contractility in assessing cardiovascular dysfunction.


Assuntos
Imagem Cinética por Ressonância Magnética , Miócitos Cardíacos , Voluntários Saudáveis , Humanos , Imagens de Fantasmas
11.
Med Image Anal ; 68: 101932, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33383331

RESUMO

Since heart contraction results from the electrically activated contraction of millions of cardiomyocytes, a measure of cardiomyocyte shortening mechanistically underlies cardiac contraction. In this work we aim to measure preferential aggregate cardiomyocyte ("myofiber") strains based on Magnetic Resonance Imaging (MRI) data acquired to measure both voxel-wise displacements through systole and myofiber orientation. In order to reduce the effect of experimental noise on the computed myofiber strains, we recast the strains calculation as the solution of a boundary value problem (BVP). This approach does not require a calibrated material model, and consequently is independent of specific myocardial material properties. The solution to this auxiliary BVP is the displacement field corresponding to assigned values of myofiber strains. The actual myofiber strains are then determined by minimizing the difference between computed and measured displacements. The approach is validated using an analytical phantom, for which the ground-truth solution is known. The method is applied to compute myofiber strains using in vivo displacement and myofiber MRI data acquired in a mid-ventricular left ventricle section in N=8 swine subjects. The proposed method shows a more physiological distribution of myofiber strains compared to standard approaches that directly differentiate the displacement field.


Assuntos
Ventrículos do Coração , Contração Miocárdica , Animais , Imageamento por Ressonância Magnética , Miocárdio , Imagens de Fantasmas , Suínos
12.
J Cardiovasc Magn Reson ; 22(1): 85, 2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33302967

RESUMO

BACKGROUND: Cardiovascular disease is the leading cause of death in patients with Duchenne muscular dystrophy (DMD)-a fatal X-linked genetic disorder. Late gadolinium enhancement (LGE) imaging is the current gold standard for detecting myocardial tissue remodeling, but it is often a late finding. Current research aims to investigate cardiovascular magnetic resonance (CMR) biomarkers, including native (pre-contrast) T1 and extracellular volume (ECV) to evaluate the early on-set of microstructural remodeling and to grade disease severity. To date, native T1 measurements in DMD have been reported predominantly at 1.5T. This study uses 3T CMR: (1) to characterize global and regional myocardial pre-contrast T1 differences between healthy controls and LGE + and LGE- boys with DMD; and (2) to report global and regional myocardial post-contrast T1 values and myocardial ECV estimates in boys with DMD, and (3) to identify left ventricular (LV) T1-mapping biomarkers capable of distinguishing between healthy controls and boys with DMD and detecting LGE status in DMD. METHODS: Boys with DMD (N = 28, 13.2 ± 3.1 years) and healthy age-matched boys (N = 20, 13.4 ± 3.1 years) were prospectively enrolled and underwent a 3T CMR exam including standard functional imaging and T1 mapping using a modified Look-Locker inversion recovery (MOLLI) sequence. Pre-contrast T1 mapping was performed on all boys, but contrast was administered only to boys with DMD for post-contrast T1 and ECV mapping. Global and segmental myocardial regions of interest were contoured on mid LV T1 and ECV maps. ROI measurements were compared for pre-contrast myocardial T1 between boys with DMD and healthy controls, and for post-contrast myocardial T1 and ECV between LGE + and LGE- boys with DMD using a Wilcoxon rank-sum test. Results are reported as median and interquartile range (IQR). p-Values < 0.05 were considered significant. Receiver Operating Characteristic analysis was used to evaluate a binomial logistic classifier incorporating T1 mapping and LV function parameters in the tasks of distinguishing between healthy controls and boys with DMD, and detecting LGE status in DMD. The area under the curve is reported. RESULTS: Boys with DMD had significantly increased global native T1 [1332 (60) ms vs. 1289 (56) ms; p = 0.004] and increased within-slice standard deviation (SD) [100 (57) ms vs. 74 (27) ms; p = 0.001] compared to healthy controls. LGE- boys with DMD also demonstrated significantly increased lateral wall native T1 [1322 (68) ms vs. 1277 (58) ms; p = 0.001] compared to healthy controls. LGE + boys with DMD had decreased global myocardial post-contrast T1 [565 (113) ms vs 635 (126) ms; p = 0.04] and increased global myocardial ECV [32 (8) % vs. 28 (4) %; p = 0.02] compared to LGE- boys. In all classification tasks, T1-mapping biomarkers outperformed a conventional biomarker, LV ejection fraction. ECV was the best performing biomarker in the task of predicting LGE status (AUC = 0.95). CONCLUSIONS: Boys with DMD exhibit elevated native T1 compared to healthy, sex- and age-matched controls, even in the absence of LGE. Post-contrast T1 and ECV estimates from 3T CMR are also reported here for pediatric patients with DMD for the first time and can distinguish between LGE + from LGE- boys. In all classification tasks, T1-mapping biomarkers outperform a conventional biomarker, LVEF.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Distrofia Muscular de Duchenne/complicações , Miocárdio/patologia , Função Ventricular Esquerda , Remodelação Ventricular , Adolescente , Fatores Etários , California , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Estudos de Casos e Controles , Criança , Meios de Contraste/administração & dosagem , Humanos , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Distrofia Muscular de Duchenne/diagnóstico , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Adulto Jovem
13.
PLoS One ; 15(11): e0241996, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33180823

RESUMO

PURPOSE: Cardiomyocyte organization and performance underlie cardiac function, but the in vivo mobility of these cells during contraction and filling remains difficult to probe. Herein, a novel trigger delay (TD) scout sequence was used to acquire high in-plane resolution (1.6 mm) Spin-Echo (SE) cardiac diffusion tensor imaging (cDTI) at three distinct cardiac phases. The objective was to characterize cardiomyocyte organization and mobility throughout the cardiac cycle in healthy volunteers. MATERIALS AND METHODS: Nine healthy volunteers were imaged with cDTI at three distinct cardiac phases (early systole, late systole, and diastasis). The sequence used a free-breathing Spin-Echo (SE) cDTI protocol (b-values = 350s/mm2, twelve diffusion encoding directions, eight repetitions) to acquire high-resolution images (1.6x1.6x8mm3) at 3T in ~7 minutes/cardiac phase. Helix Angle (HA), Helix Angle Range (HAR), E2 angle (E2A), Transverse Angle (TA), Mean Diffusivity (MD), diffusion tensor eigenvalues (λ1-2-3), and Fractional Anisotropy (FA) in the left ventricle (LV) were characterized. RESULTS: Images from the patient-specific TD scout sequence demonstrated that SE cDTI acquisition was possible at early systole, late systole, and diastasis in 78%, 100% and 67% of the cases, respectively. At the mid-ventricular level, mobility (reported as median [IQR]) was observed in HAR between early systole and late systole (76.9 [72.6, 80.5]° vs 96.6 [85.9, 100.3]°, p<0.001). E2A also changed significantly between early systole, late systole, and diastasis (27.7 [20.8, 35.1]° vs 45.2 [42.1, 49]° vs 20.7 [16.6, 26.4]°, p<0.001). CONCLUSION: We demonstrate that it is possible to probe cardiomyocyte mobility using multi-phase and high resolution cDTI. In healthy volunteers, aggregate cardiomyocytes re-orient themselves more longitudinally during contraction, while cardiomyocyte sheetlets tilt radially during wall thickening. These observations provide new insights into the three-dimensional mobility of myocardial microstructure during systolic contraction.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Miócitos Cardíacos/fisiologia , Adulto , Movimento Celular , Imagem de Tensor de Difusão , Feminino , Voluntários Saudáveis , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Miócitos Cardíacos/citologia , Função Ventricular Esquerda
14.
NMR Biomed ; 33(12): e4308, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32342560

RESUMO

The development and implementation of novel MRI pulse sequences remains challenging and laborious. Gradient waveforms are typically designed using a combination of analytical and ad hoc methods to construct each gradient waveform axis independently. This strategy makes coding the pulse sequence complicated, in addition to being time inefficient. As a consequence, nearly all commercial MRI pulse sequences fail to maximize use of the available gradient hardware or efficiently mitigate physiological effects. This results in expensive MRI systems that underperform relative to their inherent hardware capabilities. To address this problem, a software solution is proposed that incorporates numerical optimization methods into MRI pulse sequence programming. Examples are shown for rotational variant vs. invariant waveform designs, acceleration nulled velocity encoding gradients, and mitigation of peripheral nerve stimulation for diffusion encoding. The application of optimization methods to MRI pulse sequence design incorporates gradient hardware limits and the prescribed MRI protocol parameters (e.g. field-of-view, resolution, gradient moments, and/or b-value) to simultaneously construct time-optimal gradient waveforms. In many cases, the resulting constrained gradient waveform design problem is convex and can be solved on-the-fly on the MRI scanner. The result is a set of multi-axis time-optimal gradient waveforms that satisfy the design constraints, thereby increasing SNR-efficiency. These optimization methods can also be used to mitigate imaging artifacts (e.g. eddy currents) or account for peripheral nerve stimulation. The result of the optimization method is to enable easier pulse sequence gradient waveform design and permit on-the-fly implementation for a range of MRI pulse sequences.


Assuntos
Imageamento por Ressonância Magnética/métodos , Análise de Ondaletas , Meios de Contraste/química , Difusão , Estimulação Elétrica , Humanos , Nervos Periféricos/diagnóstico por imagem , Nervos Periféricos/fisiologia , Rotação
15.
J Vasc Interv Radiol ; 31(10): 1691-1696.e1, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32178944

RESUMO

PURPOSE: To characterize the effect of hepatic vessel flow using 4-dimensional (4D) flow magnetic resonance (MR) imaging and correlate their effect on microwave ablation volumes in an in vivo non-cirrhotic porcine liver model. MATERIALS AND METHODS: Microwave ablation antennas were placed under ultrasound guidance in each liver lobe of swine (n = 3 in each animal) for a total of 9 ablations. Pre- and post-ablation 4D flow MR imaging was acquired to quantify flow changes in the hepatic vasculature. Flow measurements, along with encompassed vessel size and vessel-antenna spacing, were then correlated with final ablation volume from segmented MR images. RESULTS: The linear regression model demonstrated that the preablation measurement of encompassed hepatic vein size (ß = -0.80 ± 0.25, 95% confidence interval [CI] -1.15 to -0.22; P = .02) was significantly correlated to final ablation zone volume. The addition of hepatic vein flow rate found via 4D flow MRI (ß = -0.83 ± 0.65, 95% CI -2.50 to 0.84; P = .26), and distance from antenna to hepatic vein (ß = 0.26 ± 0.26, 95% CI -0.40 to 0.92; P = .36) improved the model accuracy but not significantly so (multivariate adjusted R2 = 0.70 vs univariate (vessel size) adjusted R2 = 0.63, P = .24). CONCLUSIONS: Hepatic vein size in an encompassed ablation zone was found to be significantly correlated with final ablation zone volume. Although the univariate 4D flow MR imaging-acquired measurements alone were not found to be statistically significant, its addition to hepatic vein size improved the accuracy of the ablation volume regression model. Pre-ablation 4D flow MR imaging of the liver may assist in prospectively optimizing thermal ablation treatment.


Assuntos
Técnicas de Ablação , Veias Hepáticas/diagnóstico por imagem , Circulação Hepática , Fígado/irrigação sanguínea , Fígado/cirurgia , Imagem Cinética por Ressonância Magnética , Micro-Ondas , Imagem de Perfusão/métodos , Animais , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Veias Hepáticas/fisiopatologia , Modelos Animais , Valor Preditivo dos Testes , Sus scrofa
16.
Radiology ; 295(3): 542-549, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32208095

RESUMO

Background After acute myocardial infarction (AMI), reperfusion injury is associated with microvascular lesions and myocardial edema. Purpose To evaluate the performance of apparent diffusion coefficient (ADC) quantification compared with T1 and T2 values in the detection of acute myocardial injury. Materials and Methods In this prospective study conducted from June 2016 to November 2018, participants without a history of heart failure or cardiomyopathy were enrolled after undergoing reperfusion for their first AMI. Quantitative T1 and T2 mapping were performed with a 1.5-T MRI scanner and compared with a fast free-breathing acquisition technique for ADC mapping (approximate duration, 3 minutes; five slices; spin-echo cardiac diffusion acquisition; b values, 0 and 200 sec/mm2; six diffusion-encoding directions; five repetitions). Quantitative ADC and unenhanced T1 and T2 values were compared in infarct, border, and remote regions by using Welch analysis of variance with Games-Howell post hoc test for pairwise comparisons. Results Thirty-four participants with AMI underwent MRI an average of 5 days ± 1.9 (standard deviation) after reperfusion. Mean ADC was markedly high in the infarcted regions (2.32 × 10-3 mm2/sec; 95% confidence interval [CI]: 2.28, 2.36) and moderately high in the border regions (1.91 ×10-3 mm2/sec; 95% CI: 1.89, 1.94; P < .001). In remote regions, mean ADC (1.62 ×10-3 mm2/sec; 95% CI: 1.59, 1.64) was comparable to that measured in vivo in healthy volunteers. Within the same regions of interest, although the measures showed similar trends in infarct and remote regions for T1 (mean, 1332 mec [95% CI: 1296, 1368] vs 1045 msec [95% CI: 1034, 1056]; P < .001) and T2 (72 msec [95% CI: 69, 75] vs 50 msec [95% CI: 49, 51]; P < .001), the magnitude of the differences among regions was greater when using ADC. Normalized signal differences between infarct and remote regions showed that diffusion-weighted MRI depicted edema 5.1 (P < .001) and 3.5 (P < .001) times greater than did T1 and T2 maps, respectively. Conclusion Multislice cardiac diffusion-weighted images could be acquired in those with acute myocardial injury. Quantitative apparent diffusion coefficient mapping showed greater differences among remote regions and lesions than did T1 or T2 mapping. © RSNA, 2020 See also the editorial by Lloyd and Farris in this issue.


Assuntos
Edema/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
17.
J Magn Reson Imaging ; 52(1): 91-102, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31922311

RESUMO

BACKGROUND: MRI exams for patients with MR-conditional active implantable medical devices (AIMDs) are contraindicated unless specific conditions are met. This limits the maximum specific absorption rate (SAR, W/kg). Currently, there is no general framework to guide meeting a lower SAR limit. PURPOSE: To design and evaluate a workflow for modifying MRI protocols to whole-body SAR (WB-SAR ≤0.1 W/kg) and local-head SAR (LH-SAR ≤0.3 W/kg) limits while mitigating the impact on image quality and exam time. STUDY TYPE: Prospective. POPULATION: Twenty healthy volunteers on head (n = 5), C-spine (n = 5), T-spine (n = 5), and L-spine (n = 5) with IRB consent. ASSESSMENT: Vendor-provided head, C-spine, T-spine, and L-spine protocols (SARRT ) were modified to meet both low SAR targets (SARLOW ) using the proposed workflow. in vitro SNR and CNR were evaluated with a T1 -T2 phantom. in vivo image quality and clinical acceptability were scored using a 5-point Likert scale for two blinded readers. FIELD STRENGTH/SEQUENCES: 1.5T/spin-echoes, gradient-echoes. STATISTICAL ANALYSIS: In vitro SNR and CNR values were evaluated with a repeated measures general linear model. in vivo image quality and clinical acceptability were evaluated using a generalized estimating equation analysis (GEE). The two reader's level of agreement was analyzed using Cohen's kappa statistical analysis. RESULTS: Using the workflow, SAR limits were met. LH-SAR: 0.12 ± 0.02 W/kg, median (SD) values for LH-SAR were 0.12 (0.02) W/kg and WB-SAR: 0.09 (0.01) W/kg. Examination time did not increase ≤2x the initial time. SARRT SNR values were higher and significantly different than SARLOW (P < 0.05). However, no significant difference was observed between the CNR values (value = 0.21). Median (IQR) CNR values were 14.2 (25.0) vs. 15.1 (9.2) for head, 12.1 (16.9) vs. 25.3 (14.2) for C-spine, 81.6 (70.1) vs. 71.0 (26.6) for T-spine, and 51.4 (52.6) vs. 37.7 (27.3) for L-spine. Image quality scores were not significantly different between SARRT and SARLOW (median [SD] scores were 4.0 [0.01] vs. 4.3 [0.2], P > 0.05). DATA CONCLUSION: The proposed workflow provides guidance for modifying routine MRI exams to achieve low SAR limits. This can benefit patients referred for an MRI exam with low SAR MR-conditional AIMDs. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2020;52:91-102.


Assuntos
Imageamento por Ressonância Magnética , Próteses e Implantes , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Fluxo de Trabalho
19.
IEEE Trans Med Imaging ; 39(3): 656-667, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31398112

RESUMO

Changes in left ventricular (LV) aggregate cardiomyocyte orientation and deformation underlie cardiac function and dysfunction. As such, in vivo aggregate cardiomyocyte "myofiber" strain ( [Formula: see text]) has mechanistic significance, but currently there exists no established technique to measure in vivo [Formula: see text]. The objective of this work is to describe and validate a pipeline to compute in vivo [Formula: see text] from magnetic resonance imaging (MRI) data. Our pipeline integrates LV motion from multi-slice Displacement ENcoding with Stimulated Echoes (DENSE) MRI with in vivo LV microstructure from cardiac Diffusion Tensor Imaging (cDTI) data. The proposed pipeline is validated using an analytical deforming heart-like phantom. The phantom is used to evaluate 3D cardiac strains computed from a widely available, open-source DENSE Image Analysis Tool. Phantom evaluation showed that a DENSE MRI signal-to-noise ratio (SNR) ≥20 is required to compute [Formula: see text] with near-zero median strain bias and within a strain tolerance of 0.06. Circumferential and longitudinal strains are also accurately measured under the same SNR requirements, however, radial strain exhibits a median epicardial bias of -0.10 even in noise-free DENSE data. The validated framework is applied to experimental DENSE MRI and cDTI data acquired in eight ( N=8 ) healthy swine. The experimental study demonstrated that [Formula: see text] has decreased transmural variability compared to radial and circumferential strains. The spatial uniformity and mechanistic significance of in vivo [Formula: see text] make it a compelling candidate for characterization and early detection of cardiac dysfunction.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Miócitos Cardíacos , Animais , Doenças Cardiovasculares/diagnóstico por imagem , Coração , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Suínos
20.
J Magn Reson Imaging ; 51(5): 1526-1539, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31625663

RESUMO

BACKGROUND: Prostate diffusion-weighted imaging (DWI) using monopolar encoding is sensitive to eddy-current-induced distortion artifacts. Twice-refocused bipolar encoding suppresses eddy current artifacts, but increases echo time (TE), leading to lower signal-to-noise ratio (SNR). Optimization of the diffusion encoding might improve prostate DWI. PURPOSE: To evaluate eddy current nulled convex optimized diffusion encoding (ENCODE) for prostate DWI with minimal TE. STUDY TYPE: Prospective cohort study. POPULATION: A diffusion phantom, an ex vivo prostate specimen, 10 healthy male subjects (27 ± 3 years old), and five prostate cancer patients (62 ± 7 years old). FIELD STRENGTH/SEQUENCE: 3T; single-shot spin-echo echoplanar DWI. ASSESSMENT: Eddy-current artifacts, TE, SNR, apparent diffusion coefficient (ADC), and image quality scores from three independent readers were compared between monopolar, bipolar, and ENCODE prostate DWI for standard-resolution (1.6 × 1.6 mm2 , partial Fourier factor [pF] = 6/8) and higher-resolution protocols (1.6 × 1.6 mm2 , pF = off; 1.0 × 1.0 mm2 , pF = 6/8). STATISTICAL TESTING: SNR and ADC differences between techniques were tested with Kruskal-Wallis and Wilcoxon signed-rank tests (P < 0.05 considered significant). RESULTS: Eddy current suppression with ENCODE was comparable to bipolar encoding (mean coefficient of variation across three diffusion directions of 9.4% and 9%). For a standard-resolution protocol, ENCODE achieved similar TE as monopolar and reduced TE by 14 msec compared to bipolar, resulting in 27% and 29% higher mean SNR in prostate transition zone (TZ) and peripheral zone (PZ) (P < 0.05) compared to bipolar, respectively. For higher-resolution protocols, ENCODE achieved the shortest TE (67 msec), with 17-21% and 58-70% higher mean SNR compared to monopolar (TE = 77 msec) and bipolar (TE = 102 msec) in PZ and TZ (P < 0.05). No significant differences were found in mean TZ (P = 0.91) and PZ ADC (P = 0.94) between the three techniques. ENCODE achieved similar or higher image quality scores than bipolar DWI in patients, with mean intraclass correlation coefficient of 0.77 for overall quality between three independent readers. DATA CONCLUSION: ENCODE minimizes TE (improves SNR) and reduces eddy-current distortion for prostate DWI compared to monopolar and bipolar encoding. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1526-1539.


Assuntos
Imagem de Difusão por Ressonância Magnética , Próstata , Adulto , Idoso , Imagem Ecoplanar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...