Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Plasmonics ; : 1-9, 2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37360050

RESUMO

Severe respiratory syndrome COVID-19 (SARS-CoV-2) outbreak has became the most important global health issue, and simultaneous efforts to fast and low-cost diagnosis of this virus were performed by researchers. One of the most usual tests was colorimetric methods based on the change of color of gold nanoparticles in the presence of viral antibodies, antigens, and other biological agents. This spectral change can be due to the aggregation of the particles or the shift of localized surface plasmon resonance due to the electrical interactions of surface agents. It is known that surface agents could easily shift the absorption peak of metallic nanocolloids which is attributed to the localized surface plasmon resonance. Experimental diagnosis assays for colorimetric detection of SARS-CoV-2 using Au NPs were reviewed, and the shift of absorption peak was studied from the viewpoint of numerical analysis. Using the numerical method, the refractive index and real and imaginary parts of the effective relative permittivity of the viral biological shell around Au NPs were obtained. This model gives a quantitative description of colorimetric assays of the detection of SARS-CoV-2 using Au NPs.

3.
Artigo em Inglês | MEDLINE | ID: mdl-36798947

RESUMO

Purpose: To investigate the possibility to be able to offer left sided breast cancer patients, not suitable for DIBH, an organ at risk saving treatment. Materials and Methods: Twenty patients receiving radiotherapy for left breast cancer in DIBH were enrolled in the study. Planning CT scans were acquired in the same supine treatment position in FB and DIBH. 3DCRT_DIBH plans were designed and optimized using two parallel opposed tangent beams (with some additional segments) for the breast and chest wall and anterior-posterior fields for regional lymph nodes irradiation. Additionally, FB helical tomotherapy plans were optimized to minimize heart and lung dose. All forty plans were optimized with at least 95% of the total CTV covered by the 95% of prescribed dose of 50 Gy in 25 fractions. Results: HT_FB plans showed significantly better dose homogeneity and conformity compared to the 3DCRT_DIBH specially for regional nodal irradiation. The heart mean dose was almost comparable in 3DCRT_DIBH and HT_FB while the volume (%) of the heart receiving 25 Gy had a statistically significant reduction from 7.90 ± 3.33 in 3DCRT_DIBH to 0.88 ± 0.66 in HT_FB. HT_FB was also more effective in left descending artery (LAD) mean dose reduction about 100% from 30.83 ± 9.2 Gy to 9.7 ± 3.1. The ipsilateral lung volume receiving 20 Gy has a further reduction of 43 % in HT_FB compared with 3DCRT_DIBH. For low dose comparison, 3DCRT_DIBH was superior for contralateral organ sparing compared to the HT_FB due to the limited angle for dose delivery. Conclusion: For patients who cannot be a candidate for DIBH for any reason, HT in free breathing may be a good alternative and provides heart and ipsilateral lung dose sparing, however with the cost of increased dose to contralateral breast and lung.

4.
Med Biol Eng Comput ; 61(2): 435-444, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36460872

RESUMO

A buildup bolus is used during the post-mastectomy radiotherapy (PMRT) to overcome under-dosage issues in the chest wall. The current study is aimed at evaluating the performance of a bolus in dose enhancement through both film dosimetry and treatment planning approaches. Twenty patients were enrolled in current research. The received dose by the skin at the lateral and medial regions of the chest wall in the presence and absence bolus was evaluated. Film dosimetry results showed that the presence of the bolus can averagely increase the skin dose by about 80% (P value < 0.001) and 92% (P value < 0.001) in lateral and medial regions, respectively. No significant difference was observed between the measured and treatment planning system (TPS)-calculated dose values in the presence of bolus. The presence of the bolus can considerably increase the absorbed dose by superficial chest wall regions. The TPS shows a favorable performance in superficial dose calculations in the presence of the buildup bolus. Hosseini et al.: demonstration of implemented research in the current study.


Assuntos
Neoplasias da Mama , Dosimetria Fotográfica , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Mastectomia , Planejamento da Radioterapia Assistida por Computador , Pele , Dosagem Radioterapêutica
5.
Rep Pract Oncol Radiother ; 27(5): 881-896, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523810

RESUMO

Background: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. Materials and methods: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. Results: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. Conclusion: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy.

6.
Comput Methods Programs Biomed ; 224: 107000, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35810506

RESUMO

BACKGROUND AND OBJECTIVE: One of the principal deficits of TG-43(U1) dosimetry protocol is ignoring the attenuation effect of each seed during the multiseed brachytherapy implants. To take into account this shadowing effect, a parameter known as the inter-seed effect (ISE) has been introduced. Current study aims to evaluate and compare the ISE for some I-125 brachytherapy seeds through a Monte Carlo (MC) simulation approach. METHODS: Five different models of I-125 seeds including 6711, ProstaSeed, STM 1251, 3500, and IAI-125A were simulated by MCNPX MC Code. Validity of simulated seed models was confirmed through comparing the corresponding dosimetric parameters such as radial dose function and anisotropy function with those reported by relevant literature. Then, the ISE for each seed at different distances was determined in three seeds implant configuration. Additionally, the relevant attenuation factors (AF) were also determined for each brachytherapy source. RESULTS: The obtained results demonstrated that minimum inter-seed attenuation belongs to the ProstaSeed. In return, the maximum inter-seed attenuation was found for 3500 brachytherapy seed. The mean attenuation factor for 6711, ProstaSeed, STM 1251, 3500, and IAI-125A seed models was equal to 0.764, 0.829, 0.785, 0.594, and 0.772, respectively. CONCLUSIONS: It can be concluded that the considered I-125 brachytherapy seeds show different inter-seed effects and mean AF values for the same multiseed implant arrangement. This finding can be attributed to discrepancies in internal seed design and configuration.


Assuntos
Braquiterapia , Anisotropia , Braquiterapia/métodos , Radioisótopos do Iodo/uso terapêutico , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica
7.
Radiat Environ Biophys ; 60(1): 125-134, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33389050

RESUMO

The study reported in the present paper aimed to evaluate the effective energy (Eeff) of X-rays emitted from the surface of a bare X-ray probe and from different spherical applicators with various diameters, which are widely employed for low kV intraoperative radiotherapy (IORT) of breast cancer. A previously validated Monte Carlo model of the INTRABEAM system along with applicator diameters of 1.5-5 cm (with 0.5 cm increments) was employed for this purpose. The results show that the presence of the applicator can considerably harden the X-rays produced by the bare probe so that Eeff increases by a factor of about 2.6. Variations of applicator diameter also affects the X-ray effective energy. Specifically, increasing the applicator diameter from 1.5 to 3 cm and 3.5-5 cm resulted in an increase in the Eeff by 8.8% and 14.6%, respectively. The validity of the calculated Eeff values was confirmed by a reasonable agreement between the obtained probability density distributions (PDDs) for the full X-ray energy spectrum and those for the corresponding single effective energies, for different applicator diameters. The Eeff values obtained for different applicator diameters and the bare probe alone can be used as an alternative for the corresponding full energy spectra, in Monte Carlo-based dosimetry simulations of low-energy therapeutic X-rays, as well as for determining quality conversion factors of any ion chambers employed for low kV-IORT absolute dosimetry.


Assuntos
Neoplasias da Mama/radioterapia , Modelos Biológicos , Terapia por Raios X , Simulação por Computador , Feminino , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica
8.
Phys Med ; 80: 297-307, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33246189

RESUMO

INTRODUCTION: Low-kV IORT (Low kilovoltage intraoperative radiotherapy) using INTRABEAM machine and dedicated spherical applicators is a candidate modality for breast cancer treatment. The current study aims to quantify the RBE (relative biologic effectiveness) variations of emitted X-rays from the surface of different spherical applicators and bare probe through a hybrid Monte Carlo (MC) simulation approach. MATERIALS AND METHODS: A validated MC model of INTRABEAM machine and different applicator diameters, based on GEANT4 Toolkit, was employed for RBE evaluation. To doing so, scored X-ray energy spectra at the surface of each applicator diameter/bare probe were used to calculate the corresponding secondary electron energy spectra at various distances inside the water and breast tissue. Then, MCDS (Monte Carlo damage simulation) code was used to calculate the RBE values according to the calculated electron spectra. RESULTS: Presence of spherical applicators can increase the RBE of emitted X-rays from the bare probe by about 22.3%. In return, changing the applicator diameter has a minimal impact (about 3.2%) on RBE variation of emitted X-rays from each applicator surface. By increasing the distance from applicator surface, the RBE increments too, so that its value enhances by about 10% with moving from 2 to 10 mm distance. Calculated RBE values within the breast tissue were higher than those of water by about 4% maximum value. CONCLUSION: Ball section of spherical IORT applicators can affect the RBE value of the emitted X-rays from INTRABEAM machine. Increased RBE of breast tissue can reduce the prescribed dose for breast irradiation if INTRABEAM machine has been calibrated inside the water.


Assuntos
Mama , Eficiência Biológica Relativa , Mama/efeitos da radiação , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica , Raios X
9.
Rep Pract Oncol Radiother ; 25(1): 109-112, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31908603

RESUMO

AIM: The purpose of this study was to investigate the crosstalk effects between adjacent pixels in a thin silicon detector with 50 um thickness. BACKGROUND: There are some limitations in the applications of detectors in hadron therapy. So it is necessary to have a detector with concurrent excellent time and resolution. In this work, the GEANT4 toolkit was applied to estimate the best value for energy cutoff in the thin silicon detector in order to optimize the detector. MATERIALS AND METHODS: GEANT4 toolkit was applied to simulate the transport and interactions of particles. Calculations were performed for a thin silicon detector (2 cm × 2 cm×0.005 cm) irradiated by proton and carbon ion beams. A two-dimensional array of silicon pixels in the x-y plane with 100 um × 100 um × 50 um dimensions build the whole detector. In the end, the ROOT package is used to interpret and analyze the results. RESULTS: It is seen that by the presence of energy cutoff, pixels with small deposited energy are ignored. The best values for energy cutoff are 0.01 MeV and 0.7 MeV for proton and carbon ion beams, respectively. By applying these energy cutoff values, efficiency and purity values are maximized and also minimum output errors are achieved. CONCLUSIONS: The results are reasonable, good and useful to optimize the geometry of future silicon detectors in order to be used as beam monitoring in hadron therapy applications.

10.
Z Med Phys ; 30(1): 60-69, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31570300

RESUMO

Low-kV IORT is an increasing modality for breast cancer treatment. Soft X-rays from INTRABEAM (Carl Zeiss Meditec AG, Oberkochen, Germany), a dedicated IORT device along with special spherical applicators are employed for this purpose. A Monte Carlo model of INTRAMBEAM and spherical applicators are introduced in the current study to evaluate the dosimetric and physical characteristics of emitted X-rays from the bare probe and different applicator diameters. X-ray probe and different applicator diameters of 1.5cm to 5cm were simulated by GEANT4 Monte Carlo Toolkit. Then, the validity of the simulated model was evaluated by comparing the Monte Carlo based PDD (percentage depth dose) and anisotropy data with those reported by the manufacturer. Finally, the physical characteristics of X-rays such as the mean and most probable energy as well as the LET of secondary electrons were obtained and analyzed. There was a good agreement between the simulated and reported PDDs for bare probe and different applicator diameters. The anisotropy values were also within an exemplary range reported by the manufacturer. The X-ray mean energy shifts from 25.6keV to 28.6keV with variations of applicator diameter. The maximum variation of the secondary electron LET was 9% with changing the applicator diameter. The usefulness of GEANT4 Toolkit for Monte Carlo based commissioning of INTRABEAM machine was confirmed in the current study. The variations of the applicator diameter slightly changed the physical characteristics of low-kV X-rays and LET of secondary electrons which cannot considerably affect the relative biologic effectiveness (RBE) for different applicator diameters.


Assuntos
Neoplasias da Mama/radioterapia , Dosagem Radioterapêutica , Radioterapia/métodos , Simulação por Computador , Feminino , Humanos , Método de Monte Carlo
11.
J Cancer Res Ther ; 15(3): 491-497, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31169209

RESUMO

AIM: The main purpose of this study is to evaluate the effect of dose perturbation due to common dental restoration materials in the head and neck radiotherapy with a 15 MV external photon beam. SETTING AND DESIGN: Teeth with three dental restorations such as tooth filled with Amalgam, Ni-Cr alloy, and Ceramco were simulated by MCNPX Monte Carlo code. In this simulation, the dental materials were exposed by a 15 MV photon beam from a Siemens Primus linac, inside a water phantom. MATERIALS AND METHODS: A Siemens Primus linear accelerator and a phantom including: tooth only, tooth with Amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco were simulated by MCNPX Monte Carlo code, separately. The percentage dose change was evaluated relative to dose in water versus depth for these samples on the beam's central axis. The absolute dose by prescription of 100 cGy dose in water phantom at 3.0 cm depth was calculated for water, tooth, tooth with Amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco. RESULTS: The maximum percentage dose change is related to tooth with Ni-Cr alloy, tooth, tooth with Ceramco, and tooth with Amalgam with amounts of 7.73%, 6.95%, 4.7%, and 3.06% relative to water at 0.75 cm depth, respectively. When 100.0 cGy dose was prescribed at 3.1 cm, the maximum absolute dose was 201.0% in the presence of tooth with Ni-Cr alloy at 0.75 cm. CONCLUSION: Introduction of the compositions of dental restorations can improve the accuracy of dosimetric calculations in treatment planning and protect the healthy tissues surrounding teeth from a considerable overdose.


Assuntos
Reparação de Restauração Dentária , Método de Monte Carlo , Dosagem Radioterapêutica , Radioterapia/efeitos adversos , Ligas Dentárias , Porcelana Dentária , Humanos
12.
Appl Radiat Isot ; 147: 113-120, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30870764

RESUMO

In head and neck radiation therapy, the presence of dental restorations can increase unwanted neutron dose to the patient. This study aimed at the measurement of secondary neutron production induced by irradiation of a healthy tooth, Amalgam, Ni-Cr alloy and Ceramco with a photon beam generated in the treatment head of a Siemens Primus linac at a voltage of 15 MV. The irradiation field amounted to 10 × 10 cm2. The measurements of thermal and fast-neutron equivalent doses were performed by means of CR-39 detectors positioned in various depths of a Perspex (polymethyl methacrylate) phantom as at open field as at presence of corresponding dental restorations. The general trend of thermal neutron as well as fast-neutron equivalent dose behind the denture samples reveals their reduction with increasing depth. The maximum values of thermal-neutron dose related to Amalgam, Ceramco and Ni-Cr alloy amount to 1.45 mSv/100 MU, 1.38 mSv/100 MU and 1.32 mSv/100 MU, whereas the corresponding maximum values of fast-neutron dose at the depth of 1.8 cm amount to 0.19 mSv/100 MU, 1.04 mSv/100 MU and 0.97 mSv/100 MU, respectively. The present study investigates the neutron dose accompanied with radiotherapy. It is recommended that attempts have to be made to ensure that dental restorations are not in the path of the primary high-energy photon beam. Considering treatment planning, the guidelines of radiation protection should be improved.


Assuntos
Restauração Dentária Permanente , Nêutrons Rápidos , Fótons , Radioterapia , Ligas , Amálgama Dentário , Porcelana Dentária , Humanos , Neoplasias/radioterapia , Imagens de Fantasmas , Dosagem Radioterapêutica
13.
Australas Phys Eng Sci Med ; 41(4): 853-860, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30155807

RESUMO

Several methods are introduced for skin cancer treatment. An encouraging method is radionuclide skin therapy, where high-energy beta emitting radionuclides such as 32P, 90Y, 188Re and 166Ho are employed for skin irradiation. This study aimed to calculate the dose distribution for mentioned radionuclides at different layers of skin phantom through Monte Carlo simulation. Depth dose distribution, transverse dose profile and isodose curves related to the patch sources under investigation were calculated by MCNPX code. All of calculations were performed inside a developed skin phantom. Obtained results were compared with those reported by other studies to evaluate the validity of simulations. The results showed that the 166Ho and 32P have steeper dose gradient within the depth which can lead to the better normal tissue sparing. Simulated depth dose distributions were in a good agreement with other published studies and confirmed the validity of performed simulations. The obtained transverse dose profiles at 0.2 mm depth had acceptable symmetry and flatness that can improve the dose uniformity within the target area. Calculated isodose curves showed that the 90% isodose level covers a circular area with the diameter of around 8 mm for all studied beta sources. From the results, it can be concluded that 166Ho and 32P are more effective in treatment of superficial skin lesions, while, 90Y and 188Re are more rational choices in treatment of deeply distributed skin tumors. Size of employed patch source should be based on the target area to minimize the delivered dose to the adjacent tissues.


Assuntos
Modelos Estatísticos , Método de Monte Carlo , Dosagem Radioterapêutica , Neoplasias Cutâneas/radioterapia , Humanos , Modelos Biológicos , Imagens de Fantasmas , Radioisótopos , Pele
14.
J Cancer Res Ther ; 13(3): 538-543, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28862223

RESUMO

AIM: The purpose of this study is to evaluate the effect of various dental restoration materials on dose distribution in radiotherapy of head and neck cancer with 6 MV photon beam of a medical linac. SETTING AND DESIGN: The dental restorations include tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco. Dose perturbation due to the dental restorations on 6 MV beam of Siemens Primus linac was calculated by MCNPX Monte Carlo code. These dental materials were separately simulated in a cubic water phantom. MATERIALS AND METHODS: Photon percentage dose change in the presence of tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco was calculated at various depths on the central axis of the beam relative to the dose in water. In another evaluation, the absolute dose (cGy) for water, tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco was obtained by calculating 100 cGy dose at 0.75 cm depth in the water phantom. RESULTS: Based on the calculations performed, maximum percentage dose change due to backscattering was 11%, 8%, 6%, and 4% for amalgam, Ni-Cr alloy, Ceramco and tooth at depth of 0.75 cm, respectively. The maximum dose perturbation by amalgam is due to its higher mass density and atomic number. CONCLUSION: Ignoring the effect of dental restoration compositions on dose distribution causes discrepancy in clinical treatment planning system calculations.


Assuntos
Restauração Dentária Permanente , Neoplasias de Cabeça e Pescoço/radioterapia , Fótons/uso terapêutico , Dosagem Radioterapêutica/normas , Neoplasias de Cabeça e Pescoço/complicações , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Método de Monte Carlo , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Dente/patologia , Dente/efeitos da radiação
15.
Rep Pract Oncol Radiother ; 22(1): 52-57, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27829820

RESUMO

AIM: The purpose of this work was to estimate the dependency between the produced positron emitters and the proton dose distribution as well as the dependency between points of annihilation and the proton dose distribution. BACKGROUND: One important feature of proton therapy is that, through the non-elastic nuclear interaction of protons with the target nuclei such as 12C, 14N and 16O, it produces a small number of positron-emitting radioisotopes along the beam-path. These radioisotopes allow imaging the Bragg peak position which is related to the proton dose distribution by using positron emission tomography. METHODS: In this study, the GEANT4 toolkit was applied to simulate a soft and bone tissue phantom in proton therapy to evaluate the positron emitter productions and the actual annihilation points of ß+. Simulation was done by delivering pencil and spread-out Bragg peak (SOBP) proton beams. RESULTS: The findings showed that (15O, 11C, 13N) and (11C, 15O, 38K, 30P, 39Ca, 13N) are the most suitable positron emitters in the soft and bone tissue respectively. By increasing the proton energy, the distance between the peak of annihilation profile and Bragg peak is almost constant, but the distance between the Bragg peak position and positron annihilation point peak in bone tissue is smaller than that in the soft tissue. The peak of ß+ activity distribution becomes sharper at higher proton energies. CONCLUSIONS: There is a good relationship between the positions of positron annihilation profile and positron emitters radioactive decay. Also, GEANT4 is a powerful and suitable tool for simulation of nuclear interactions and positron emitters in tissues.

16.
Iran J Radiol ; 13(4): e36484, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27895876

RESUMO

BACKGROUND: X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. OBJECTIVES: The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. MATERIALS AND METHODS: We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. RESULTS: MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. CONCLUSION: By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.

17.
Med Dosim ; 41(2): 118-25, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26831752

RESUMO

Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth-dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8MeV proton, 190.1MeV alpha, and 1060MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam׳s Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.


Assuntos
Radioterapia com Íons Pesados/instrumentação , Melanoma/radioterapia , Imagens de Fantasmas , Neoplasias Uveais/radioterapia , Radioterapia com Íons Pesados/métodos , Humanos , Método de Monte Carlo , Terapia com Prótons , Dosagem Radioterapêutica , Espalhamento de Radiação
18.
Rep Pract Oncol Radiother ; 19(6): 376-84, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25337410

RESUMO

AIM: Evaluation of energy deposition of protons in human brain and calculation of the secondary neutrons and photons produced by protons in proton therapy. BACKGROUND: Radiation therapy is one of the main methods of treating localized cancer tumors. The use of high energy proton beam in radiotherapy was proposed almost 60 years ago. In recent years, there has been a revival of interest in this subject in the context of radiation therapy. High energy protons suffer little angular deflection and have a well-defined penetration range, with a sharp increase in the energy loss at the end of their trajectories, namely the Bragg peak. MATERIALS AND METHODS: A slab head phantom was used for the purpose of simulating proton therapy in brain tissue. In this study simulation was carried out using the Monte Carlo MCNPX code. RESULTS: By using mono energetic proton pencil beams, energy depositions in tissues, especially inside the brain, as well as estimating the neutron and photon production as a result of proton interactions in the body, together with their energy spectra, were calculated or obtained. The amount of energy escaped from the head by secondary neutrons and photons was determined. CONCLUSIONS: It was found that for high energy proton beams the amount of escaped energy by neutrons is almost 10 times larger than that by photons. We estimated that at 110 MeV beam energy, the overall proton energy "leaked" from the head by secondary photons and neutrons to be around 1%.

19.
Australas Phys Eng Sci Med ; 37(2): 327-36, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24706342

RESUMO

Some chemotherapy drugs contain a high Z element in their structure that can be used for tumour dose enhancement in radiotherapy. In the present study, dose enhancement factors (DEFs) by cisplatin and titanocene dichloride agents in brachytherapy were quantified based on Monte Carlo simulation. Six photon emitting brachytherapy sources were simulated and their dose rate constant and radial dose function were determined and compared with published data. Dose enhancement factor was obtained for 1, 3 and 5 % concentrations of cisplatin and titanocene dichloride chemotherapy agents in a tumour, in soft tissue phantom. The results of the dose rate constant and radial dose function showed good agreement with published data. Our results have shown that depending on the type of chemotherapy agent and brachytherapy source, DEF increases with increasing chemotherapy drug concentration. The maximum in-tumour averaged DEF for cisplatin and titanocene dichloride are 4.13 and 1.48, respectively, reached with 5 % concentrations of the agents, and (125)I source. Dose enhancement factor is considerably higher for both chemotherapy agents with (125)I, (103)Pd and (169)Yb sources, compared to (192)Ir, (198)Au and (60)Co sources. At similar concentrations, dose enhancement for cisplatin is higher compared with titanocene dichloride. Based on the results of this study, combination of brachytherapy and chemotherapy with agents containing a high Z element resulted in higher radiation dose to the tumour. Therefore, concurrent use of chemotherapy and brachytherapy with high atomic number drugs can have the potential benefits of dose enhancement. However, more preclinical evaluations in this area are necessary before clinical application of this method.


Assuntos
Antineoplásicos/química , Braquiterapia/métodos , Cisplatino/química , Compostos Organometálicos/química , Fótons , Dosagem Radioterapêutica , Método de Monte Carlo
20.
Ann Nucl Med ; 28(8): 824-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24777651

RESUMO

BACKGROUND: The beta and gamma absorbed fractions in organs and tissues are the important key factors of radionuclide internal dosimetry based on Medical Internal Radiation Dose (MIRD) approach. OBJECTIVES: The aim of this study is to find suitable analytical functions for beta and gamma absorbed fractions in spherical and ellipsoidal volumes with a uniform distribution of iodine-131 radionuclide. METHODS: MCNPX code has been used to calculate the energy absorption from beta and gamma rays of iodine-131 uniformly distributed inside different ellipsoids and spheres, and then the absorbed fractions have been evaluated. RESULTS: We have found the fit parameters of a suitable analytical function for the beta absorbed fraction, depending on a generalized radius for ellipsoid based on the radius of sphere, and a linear fit function for the gamma absorbed fraction. CONCLUSION: The analytical functions that we obtained from fitting process in Monte Carlo data can be used for obtaining the absorbed fractions of iodine-131 beta and gamma rays for any volume of the thyroid lobe. Moreover, our results for the spheres are in good agreement with the results of MIRD and other scientific literatures.


Assuntos
Radioisótopos do Iodo , Próstata/diagnóstico por imagem , Radiometria/métodos , Glândula Tireoide/diagnóstico por imagem , Partículas beta , Simulação por Computador , Raios gama , Humanos , Radioisótopos do Iodo/química , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Cintilografia , Compostos Radiofarmacêuticos , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...