Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Audiol ; 61(6): 443-452, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34431430

RESUMO

OBJECTIVES: (1) To investigate the remote check test battery, designed for self-administration by cochlear implant (CI) recipients, parents/caregivers, to determine if the results give adequate information for clinicians to decide the necessity of an appointment and to capture suggestions for improvement. (2) To gauge acceptance of remote monitoring by CI-recipients and their parents/caregivers. DESIGN: Prospective, multicentre, un-blinded, non-randomized, single-subject, repeated-measures evaluation. The test battery includes an implant-site photograph, impedance measurements, datalogs, questionnaires, speech perception and aided threshold tests. Clinicians reviewed test battery results, followed by a clinical appointment with each CI-recipient, and reported if the battery identified all the issues. Study sample: n = 93 CI-recipients (73 adults, 20 children) and 28 clinicians. RESULTS: The test battery identified 94% (615/656) of all issues. The test battery and clinician observations agreed in 99% (92/93) of cases on the need for a clinic visit. For 68% (63/93) of cases, the test battery identified all clinician observed issues. The majority (77%, 72/93) of recipients would be satisfied if clinic visits were based on their test battery results. A significantly high proportion agreed that remote monitoring was more convenient than clinic visits and could result in travel, time and cost reductions. CONCLUSION: This is the first comprehensive test battery designed for CI-recipient remote monitoring.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Criança , Implante Coclear/métodos , Humanos , Estudo de Prova de Conceito , Estudos Prospectivos
2.
Cochlear Implants Int ; 17 Suppl 1: 17-21, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27099105

RESUMO

BACKGROUND: Adult cochlear implant (CI) candidacy is assessed in part by the use of speech perception measures. In the United Kingdom the current cut-off point to fall within the CI candidacy range is a score of less than 50% on the BKB sentences presented in quiet (presented at 70 dBSPL). GOAL: The specific goal of this article was to review the benefit of adding the AB word test to the assessment test battery for candidacy. RESULTS: The AB word test scores showed good sensitivity and specificity when calculated based on both word and phoneme scores. The word score equivalent for 50% correct on the BKB sentences was 18.5% and it was 34.5% when the phoneme score was calculated; these scores are in line with those used in centres in Wales (15% AB word score). CONCLUSION: The goal of the British Cochlear Implant Group (BCIG) service evaluation was to determine if the pre-implant assessment measures are appropriate and set at the correct level for determining candidacy, the future analyses will determine whether the speech perception cut-off point for candidacy should be adjusted and whether other more challenging measures should be used in the candidacy evaluation.


Assuntos
Implante Coclear/métodos , Surdez/diagnóstico , Seleção de Pacientes , Testes de Discriminação da Fala/métodos , Teste do Limiar de Recepção da Fala/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Implantes Cocleares , Surdez/fisiopatologia , Surdez/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Discriminação da Fala/normas , Percepção da Fala , Teste do Limiar de Recepção da Fala/normas , Resultado do Tratamento , Reino Unido , Adulto Jovem
4.
Cochlear Implants Int ; 16(2): 100-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25118042

RESUMO

OBJECTIVE: To compare the fitting time requirements and the efficiency in achieving improvements in speech perception during the first 6 months after initial stimulation of computer-assisted fitting with the Fitting to Outcome eXpert' (FOX) and a standard clinical fitting procedure. METHOD: Twenty-seven post-lingually deafened adults, newly implanted recipients of the Advanced Bionics HiRes 90K™ cochlear implant from Germany, the UK, and France took part in a controlled, randomized, clinical study. Speech perception was measured for all participants and fitting times were compared across groups programmed using FOX and conventional programming methods. RESULTS: The fitting time for FOX was significantly reduced at 14 days (P < 0.001) but equivalent over the 6-month period. The groups were not well matched for duration of deafness; therefore, speech perception could not be compared across groups. DISCUSSION: Despite including more objective measures of performance than a standard fitting approach and the adjustment of a greater range of parameters during initial fitting, FOX did not add to the overall fitting time when compared to the conventional approach. FOX significantly reduced the fitting time in the first 2 weeks and by providing a standard fitting protocol, reduced variability across centres. CONCLUSIONS: FOX computer-assisted fitting can be successfully used at switch on, in different clinical environments, reducing fitting time in the first 2 weeks and is efficient at providing a usable program.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Ajuste de Prótese/métodos , Software , Adulto , Idoso , Surdez/reabilitação , Feminino , França , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Percepção da Fala , Fatores de Tempo , Resultado do Tratamento , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...