Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur J Vasc Endovasc Surg ; 44(1): 40-4, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22621978

RESUMO

OBJECTIVES: Sac growth after endovascular aneurysm repair (EVAR) is an important finding, which may influence prognosis. In case of a type II endoleak or endotension, clipping of side branches and subsequent sac fenestration has been presented as a therapeutic alternative. The long-term clinical efficacy of this procedure is unknown. METHODS: The study included eight patients who underwent laparoscopic aortic collateral clipping and sac fenestration for enlarging aneurysms following EVAR. Secondary interventions and clinical outcome were retrieved from hospital records. Sac behaviour was evaluated measuring volumes on periodical computed tomography angiography (CTA) imaging using dedicated software. RESULTS: Follow-up had a median length of 6.6 (range 0.6-8.6) years. During this time, only three patients successfully achieved durable aneurysm shrinkage (n = 2) or stability (n = 1). The remaining patients suffered persistent (n = 2) or recurrent sac growth (n = 3), all regarded as failure of fenestration. A total of six additional interventions were performed, comprising open conversion (n = 2), relining (n = 1) and implantation of iliac extensions (n = 3). All additional interventions were successful at arresting further sac growth during the remainder of follow-up. CONCLUSIONS: Despite being a less invasive alternative to conversion and open repair, the long-term outcome of sac fenestration is unpredictable and additional major procedures were often necessary to arrest sac growth.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular , Endoleak/cirurgia , Laparoscopia/métodos , Idoso , Angiografia/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/etiologia , Progressão da Doença , Endoleak/complicações , Endoleak/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Eur J Vasc Endovasc Surg ; 41(1): 48-53, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21109470

RESUMO

OBJECTIVES: To investigate the outcomes of thoracic endovascular aortic repair (TEVAR) for ruptured descending thoracic aortic aneurysm (rDTAA) in patients older than 75 years. METHODS: We retrospectively identified all patients treated with TEVAR for rDTAA at seven referral centres between 2002 and 2009. The cohort was stratified according to age ≤75 and >75 years, and the outcomes after TEVAR were compared between both groups. RESULTS: Ninety-two patients were identified of which 73% (n = 67) were ≤75 years, and 27% (n = 25) were older than 75 years. The 30-day mortality was 32.0% in patients older than 75 years, and 13.4% in the remaining patients (p = 0.041). Patients older than 75 years suffered more frequently from postoperative stroke (24.0% vs. 1.5%, p = 0.001) and pulmonary complications (40.0% vs. 9.0%, p = 0.001). The aneurysm-related survival after 2 years was 52.1% for patients >75 years, and 83.9% for patients ≤75 years (p = 0.006). CONCLUSIONS: Endovascular treatment of rDTAA in patients older than 75 years is associated with an inferior outcome compared with patients younger than 75 years. However, the mortality and morbidity rates in patients above 75 years are still acceptable. These results may indicate that endovascular treatment for patients older than 75 years with rDTAA is worthwhile.


Assuntos
Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/mortalidade , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Hemotórax/mortalidade , Humanos , Itália/epidemiologia , Tempo de Internação/estatística & dados numéricos , Masculino , Países Baixos/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Reoperação , Estudos Retrospectivos , Choque/mortalidade , Acidente Vascular Cerebral/epidemiologia , Estados Unidos/epidemiologia
3.
J Cardiovasc Surg (Torino) ; 51(5): 657-67, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20924327

RESUMO

Aortic dissection is a devastating cardiovascular condition with an incidence of 3,5:100 000. It is classified according to anatomic extent, mechanism of lesion, duration from index event and course (uncomplicated vs. complicated). Intramural hematoma and penetrating aortic ulcers share many of the features of classic dissections, but tend to occur in older patients with advanced atherosclerosis. In uncomplicated type-B dissection, conservative treatment with tight blood pressure and heart rate control is safe and effective. Early stent-graft implantation may, however, result in more favorable aortic remodeling and reduced late complications. For acute complicated cases intervention is usually required. Stent-graft coverage of the entry tear frequently resolves malperfusion, but the role of the false lumen in organ perfusion must be assessed and endovascular revascularization performed if necessary. In chronic type-B dissections, coverage of the entry tear likely results in continued pressurization of the false lumen due to rigidity of the dissecting membrane and distal fenestrations. Better understanding of the different disease mechanisms involved, imaging advances and introduction of dedicated stent-grafts are expected to further improve patient outcomes in the future. Primary and secondary pharmacological prevention, stricter follow-up protocols and screening of family members may also prove valuable. Better patient selection will allow preventive treatment with low morbidity for those at higher risk of complications.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Medicina Baseada em Evidências , Seleção de Pacientes , Doença Aguda , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Doença Crônica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Hemodinâmica , Humanos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
4.
Eur J Vasc Endovasc Surg ; 40(5): 564-71, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20727795

RESUMO

OBJECTIVES: To investigate the impact of hypovolaemic shock on the aortic diameter in a porcine model, and to determine the implications for the endovascular management of hypovolaemic patients with traumatic thoracic aortic injury (TTAI). MATERIALS AND METHODS: The circulating blood volume of seven Yorkshire pigs was gradually lowered in 10% increments. At 40% volume loss, an endograft was deployed in the descending thoracic aorta, followed by gradual fluid resuscitation. Potential changes in aortic diameter during the experiment were recorded using intravascular ultrasound (IVUS). RESULTS: The aortic diameter decreased significantly at all evaluated levels during blood loss. The ascending aortic diameter decreased on average with 38% after 40% blood loss (range 24-62%, p = 0.018), the descending thoracic aorta with 32% (range 18-52%, p = 0.018) and the abdominal aorta with 28% (range 15-39%, p = 0.018). The aortic diameters regained their initial size during fluid resuscitation. CONCLUSION: The aortic diameter significantly decreases during blood loss in this porcine model. If these changes take place in hypovolaemic TTAI patients as well, it may have implications for thoracic endovascular aortic repair (TEVAR). Increased oversizing of the endograft, or additional computed tomography (CT) or IVUS imaging after fluid resuscitation for more adequate aortic measurements, may be needed in TTAI patients with considerable blood loss.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Choque Hemorrágico/fisiopatologia , Animais , Aorta Torácica/lesões , Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular , Modelos Animais de Doenças , Hidratação , Masculino , Choque Hemorrágico/terapia , Suínos , Ultrassonografia de Intervenção
5.
J Cardiovasc Surg (Torino) ; 51(4): 515-31, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20671635

RESUMO

Over the last decade, endovascular aneurysm repair (EVAR) has been used extensively for the elective treatment of infra-renal abdominal aneurysms. However, it remains unclear how specific devices perform and how they compare to others. We provide an overview of currently used endografts, and discuss the current evidence regarding device-specific outcomes. Published literature confirms differences in results according to endograft selection. These differences were more pronounced with older generations of devices, in comparison to newer models. Contemporary results are generally good and one should remember that no randomized data exist regarding individual device performance. Moreover, by the time there is enough follow-up to draw conclusions, the data is relatively obsolete due to constant improvements in endograft technology and design. Results from EVAR have been steadily improving and individualized device selection has shown to be valuable. It appears that patients with favorable anatomy do well with most modern endografts. Those with challenging anatomies may benefit more from a particular design, delivery and deployment feature requiring greater knowledge and experience for adequate device selection.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Medicina Baseada em Evidências , Humanos , Seleção de Pacientes , Desenho de Prótese , Medição de Risco , Resultado do Tratamento
6.
Eur J Vasc Endovasc Surg ; 38(1): 42-53, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19428273

RESUMO

OBJECTIVE: Sizing of aortic endografts is an essential step in successful endovascular treatment of aortic pathology, although consensus regarding the optimal sizing strategy is lacking. Some proximal oversizing is necessary to obtain a seal between the stent graft and the aortic wall and to prevent the graft from migrating, but excessive oversizing might influence the results negatively. In this systematic review, we investigated the current literature to obtain an overview of the risks and benefits of oversizing and to determine the optimal degree of oversizing of stent grafts used for endovascular abdominal aortic aneurysm repair. METHODS: PUBMED, EMBASE and Cochrane Library databases were searched for articles related to the impact of proximal endograft oversizing on complications after endovascular aneurysm repair. After in- and exclusion, 23 relevant articles reporting on 8415 patients remained for analysis and critical appraisal. RESULTS: Most studies that investigated neck dilatation are flawed by poor methodology. No clear relationship between proximal oversizing and neck dilatation relative to the first post-operative scan was found. None of the studies described a positive relationship between the degree of oversizing and the incidence of endoleaks. On the contrary, oversizing up to 25% seems to decrease the risk of proximal endoleaks. There are conflicting data regarding the risk of graft migration when oversizing by more than 30%. CONCLUSIONS: Based on the best available evidence, the current standard of 10-20% oversizing regime appears to be relatively safe and preferable. Oversizing >30% might negatively impact the outcome after EVAR. Studies of higher quality are needed to further assess the relationship between proximal oversizing and the incidence of complications, particularly regarding the impact on aneurysm neck dilatation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Medição de Risco/métodos , Stents/normas , Migração de Corpo Estranho/epidemiologia , Humanos , Desenho de Prótese , Falha de Prótese , Fatores de Risco
7.
Eur J Vasc Endovasc Surg ; 37(1): 15-22, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19008129

RESUMO

OBJECTIVES: To provide insight into the causes and timing of AAA rupture after EVAR. DESIGN: Original data regarding AAA ruptures following EVAR were collected from MEDLINE and EMBASE databases. Data were extracted systematically and patient and procedural characteristics were analyzed. RESULTS: 270 patients with AAA ruptures after EVAR were identified. Causes of rupture included endoleaks (in 160: type IA 57, type IB 31, type II 23, type III 26, type IV 0, endotension 9, unspecified 14), graft migration 41, graft disconnection 11 and infection 6. Most of the described AAA ruptures occurred within 2-3 years after EVAR. Mean initial AAA diameter was relatively large (65 mm). No abnormalities were present in 41 patients during follow-up before rupture. Structural graft failure was described in 96 and a fatal course in 119 patients. CONCLUSIONS: Focus of surveillance on the first 2-3 years after EVAR may possibly reduce the AAA rupture rate, especially in patients with increased risk of early rupture (relatively large initial AAA diameter or presence of endoleak or graft migration). Better stent-graft durability and longevity is required to further reduce the AAA rupture risk after EVAR. Complete prevention will however remain challenging since AAA rupture may occur even if no predisposing abnormalities are present.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Stents
8.
J Neurointerv Surg ; 1(1): 51-2, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21994107

RESUMO

Rapidly expanding infectious pseudoaneurysms of the internal carotid artery can have deleterious consequences. A patient is reported who presented with such an aneurysm. The morphology of the aneurysm was not amenable to microsurgical treatment. The aneurysm was successfully treated with covered stents. This is only the third report of a patient with an infectious pseudoaneurysm in the internal carotid artery treated with a covered stent. At the 1 year follow-up visit, the patient continues to do well.


Assuntos
Antibacterianos/uso terapêutico , Anticoagulantes/uso terapêutico , Lesões das Artérias Carótidas/microbiologia , Lesões das Artérias Carótidas/terapia , Infecções Estafilocócicas/tratamento farmacológico , Stents , Lesões das Artérias Carótidas/diagnóstico por imagem , Materiais Revestidos Biocompatíveis , Terapia Combinada , Humanos , Masculino , Radiografia
9.
Eur J Vasc Endovasc Surg ; 36(3): 267-72, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18585935

RESUMO

PURPOSE: Clinical decision making for carotid surgery depends largely upon stenosis grade. While digital subtraction angiography remains the gold standard for stenosis grading, many physicians use less invasive modalities. The purpose of this study was to compare the results of multidimensional Computed tomography (CTA) with ultrasound (US) grading and peak flow velocity (PSV). METHODS: 37 stenosed carotid arteries were studied retrospectively in 36 consecutive patients. US grading and PSV were compared to multidimensional CTA analysis (diameter, area and volumetric measurements), performed by a medical software company. Calculations of stenosis percentage on CTA were made using the NASCET and ECST methodology. Diameter measurements were also performed by a neuroradiologist. RESULTS: All CTA diameter, area and volume measurements had only modest correlation with PSV (r<0.5) and ultrasound grading (p<0.5). There was concordant classification of stenosis grades in only 40-60% of cases. CTA diameter, area and volume measurements had good correlation (0.69

Assuntos
Estenose das Carótidas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler Dupla
10.
J Cardiovasc Surg (Torino) ; 48(5): 557-65, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17989625

RESUMO

Rupture of the thoracic aorta after a blunt traumatic accident is a life-threatening event. This injury is instantly fatal in about 80% of the victims, and half of those who initially survive the incident will die during the first day, if left untreated. Before 1997, patients were treated with an open repair, but the conventional surgical approach carries a high mortality and morbidity rate. Graft interposition and cross-clamping of the aorta are responsible for a high paraplegia rate. Despite the fact that active distal perfusion of the aorta lowers the incidence of neurological deficit, the timing of these extensive procedures in the severely injured multi-trauma patient is difficult. The endovascular repair of a traumatic thoracic aortic rupture has gained rapid acceptance as a better alternative. This minimally invasive procedure has a median operating time of <1 h, and it can be done during the same session in which other life-threatening injuries are repaired. There is no need for a thoracotomy or single lung ventilation, blood loss is minimal and systemic heparinization is not required. So far, no spinal cord ischemia has been described for the endovascular repair. Besides numerous advantages, a few problems can be expected. The narrow aortic diameter of these young trauma-victims, combined with a steep aortic arch, makes the adaptation of the endograft along the inner curvature sometimes difficult. Because the smallest endograft usually exceeds the narrow aortic diameter, only excessively oversized devices can be used, which explains the high type I endoleak encountered in the published series. No randomized studies are yet available comparing the open with the endovascular technique, but the initial results of the endovascular repair seem promising and lower mortality and morbidity rates are documented. Long-term outcome are lacking so far, but are needed to address the durability of the procedure. Further research and development should concentrate on the problems we have seen with steep and narrow aortic arches, and devices with more flexible curves and smaller diameters should become available in the near future.


Assuntos
Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Ferimentos não Penetrantes/complicações , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/lesões , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/cirurgia
11.
Ann Vasc Surg ; 21(6): 730-3, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17703918

RESUMO

Durable vascular access for hemodialysis remains a critical issue in end-stage renal disease patients. Creation of an autogenous arteriovenous (AV) fistula in the most distal location of the nondominant extremity is the preferred technique and provides superior patency over an AV graft. Others have shown that regional anesthesia in the form of axillary block results in the dilatation of the native veins and allows for their increased utilization in creating AV fistulae. We report on 26 patients undergoing creation of a vascular access for hemodialysis. Regional anesthesia consisting of axillary nerve block was used in all cases. All surgical plans with regard to the site and type of access were made based on the physical exam and ultrasound vein measurements taken prior to surgery. On the day of surgery patients were reevaluated with venous ultrasound using tourniquet before and after administration of the regional block. The previously determined operative plan either remained unchanged or was modified depending on the venous dilatation noted after administration of regional block. Among 26 patients, average vein diameter increased from 0.29 +/- 0.12 cm to 0.34 +/- 0.11 cm (P = 0.008). Twenty-one of 26 patients had no modification in operative plan (group 1). Five had some modification of the original operative plan (group 2): AV graft to a brachial vein transposition (n = 2), AV graft to a Cimino fistula (n = 2), and brachiocephalic to a Cimino (n = 1). The average follow-up for all patients was 82.6 +/- 75.6 days and did not differ between the groups. There was one failure in a patient from group 1, and there was no significant difference in the patency rate between study groups (P = 0.29). Following regional nerve block, operative plans in patients undergoing AV access surgery were modified in 29.4% of patients undergoing creation of an AV access for hemodialysis; either from graft to fistula creation or from the proximal to more distal fistula site. The routine use of regional anesthesia as well as intraoperative ultrasound during AV access surgery can lead to improved site selection and increased opportunity for AV fistula creation.


Assuntos
Braço/irrigação sanguínea , Derivação Arteriovenosa Cirúrgica/métodos , Implante de Prótese Vascular , Nefropatias/terapia , Bloqueio Nervoso , Seleção de Pacientes , Diálise Renal/métodos , Vasodilatação , Veias/transplante , Anestésicos Locais , Plexo Braquial , Feminino , Humanos , Nefropatias/diagnóstico por imagem , Nefropatias/fisiopatologia , Lidocaína , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Ultrassonografia , Grau de Desobstrução Vascular , Veias/diagnóstico por imagem , Veias/fisiopatologia
12.
Eur J Vasc Endovasc Surg ; 33(1): 84-90, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16931071

RESUMO

OBJECTIVE: To present our experience using fenestrated and branched endoluminal grafts for Para-anastomotic aneurysms (PAA) following prior open aneurysm surgery, and after previous endovascular aneurysm repair (EVAR) complicated by proximal type I endoleak. METHODS: Fenestrated and/or branched EVAR was performed on eleven patients. Indications included proximal type I endoleak after EVAR and short infrarenal neck (n=4), suprarenal aneurysm after open AAA (n=4), distal type I endoleak after endovascular TAA (n=1), proximal anastomotic aneurysm after open AAA (n=1), and an aborted open AAA repair due to bleeding around a short infrarenal neck. RESULTS: The operative target vessel success rate was 100% (28/28) with aneurysm exclusion in all patients. Mean hospital stay was 6.0 days (range 2-12 days, SD 3.5 days). Thirty day mortality was 0%. All cause mortality during 18 months mean follow-up (range 5-44 months, SD 16.7 months) was 18% (2/11) with no deaths from aneurysm rupture. Cumulative visceral branch patency was 96% (27/28) at 42 months. Average renal function remained unchanged during the follow-up period. CONCLUSIONS: Our report highlights the potential of fenestrated and branched technology to improve re-operative aortic surgical outcomes. The unique difficulties of increased graft on graft friction hindering placement, short working distance, and increased patient co-morbidities should be recognized.


Assuntos
Angioplastia/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Feminino , Seguimentos , Humanos , Tempo de Internação , Masculino , Desenho de Prótese , Reoperação , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Acta Chir Belg ; 106(3): 317-22, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16910005

RESUMO

Fenestrated stent-grafts aim at treating short-necked aneurysms. As a result of customized fenestrations, patency of vital side branches such as the renal arteries and the superior mesenteric artery can be maintained, whilst positioning the graft over these aortic side branches. Over the years, the technique has been refined. Results in a few experienced centers are good, with excellent patency rates of targeted side branches. Suprarenal and thoraco-abdominal aneurysms can only be treated by endovascular means with branched grafts. This can be achieved with fenestrated grafts, but with the use of covered stents through the fenestrations, or by fully branched grafts. Both options are feasible and present with specific advantages and disadvantages. This report gives an overview of our 5-years experience with fenestrated and branched grafts, and discusses the following aspects of the technique: indications, technical principles, results, and limitations.


Assuntos
Aneurisma Aórtico/cirurgia , Prótese Vascular , Stents , Desenho de Prótese
14.
Eur J Vasc Endovasc Surg ; 32(5): 532-6, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16798028

RESUMO

OBJECTIVE: Thoracic aneurysm preoperative imaging is performed using static techniques without consideration of normal aortic dynamics. Improved understanding of the native aortic environment into which thoracic endografts are placed may aid in device selection. It is unclear what comprises normal thoracic aortic pulsatility. We studied these phenomena dynamically using ECG-gated 64-slice CTA. METHODS: Maximum diameter and area change per cardiac cycle was measured at surgically relevant anatomic thoracic landmarks in ten patients; 1.0 cm proximal and distal to the subclavian artery, 3.0 cm distal to the subclavian artery, and 3.0 cm proximal to the celiac trunk. Data was acquired using a novel ECG-gated dynamic 64-slice CT scanner during a single breath hold with a standard radiation dose and contrast load. Eight gated data sets, covering the cardiac cycle were reconstructed, perpendicular to the central lumen. RESULTS: There is impressive change in both maximum diameter and area in the thoracic aorta during the cardiac cycle. Mean maximum diameter changes of greater than 10% are observed in the typical sealing zones of commercially available endografts corresponding to diameter increases of up to 5mm. Aortic area increases by over 5% per cardiac cycle. CONCLUSIONS: ECG-gated dynamic CTA with standard radiation dose is feasible on a 64-slice scanner and provides insight into (patho) physiology of thoracic aortic conformational changes. Clinicians typically oversize thoracic endografts by 10%. With aortic pulsatility resulting in diameter changes of up to 17.8%, the potential exists for endograft undersizing, graft migration, intermittent type I endoleak, and poor patient outcome. Furthermore, aortic pulsatility is not evenly distributed, and non-circular stentgraft designs should be considered in the future since aortic distension in the aneurysm neck is not evenly distributed.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Cineangiografia , Tomografia Computadorizada por Raios X , Angioplastia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Implante de Prótese Vascular , Complacência (Medida de Distensibilidade) , Eletrocardiografia , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador , Variações Dependentes do Observador , Seleção de Pacientes , Desenho de Prótese , Fluxo Pulsátil , Valores de Referência , Reprodutibilidade dos Testes
15.
J Surg Res ; 101(1): 21-8, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11676550

RESUMO

BACKGROUND: The observation that matrix metalloproteinases (MMPs) are central to tissue remodeling and may contribute to organ failure prompted us to investigate the role of MMPs in acute pancreatitis. We hypothesize that increased expression and activation of MMP-2 and MMP-9 will correlate with organ injury following acute pancreatitis. METHODS: Acute pancreatitis was induced in five male rats by retrograde infusion of 5% sodium taurocholate into the pancreatic duct. Sham laparotomy was performed on five rats serving as a control. Pancreatitis was confirmed by histology and serum amylase levels. MMP-2 and MMP-9 activity and expression were assayed by gelatin zymography in the lungs and ascitic fluid of each animal. Lung permeability was assayed by Evans blue dye extravasation. Lung activity of MMP-2 and MMP-9 was confirmed by a specific fluorogenic MMP substrate assay. RESULTS: Lung permeability increased twofold in the animals with severe pancreatitis compared with sham. Analysis of the zymograms from lung homogenate revealed a threefold increase in active MMP-2 in severe pancreatitis compared with sham and no change in MMP-9 activity. Gelatin zymograms of peritoneal fluid from severe pancreatitis animals demonstrated increased levels of active MMP-2 and MMP-9 compared with the sham group. Increases in MMP activity were confirmed by MMP activity assay using a fluorogenic substrate. CONCLUSIONS: This study demonstrates a correlation between severity of acute pancreatitis and active MMP-2 and MMP-9 levels in the peritoneal fluid and MMP-2 activity in lung homogenate. The MMP-mediated degradation of the basement membrane offers a potential pharmacologic and therapeutic target for halting the final biologic outcome of severe pancreatitis.


Assuntos
Metaloproteinases da Matriz/metabolismo , Pancreatite/enzimologia , Doença Aguda , Amilases/sangue , Animais , Líquido Ascítico/enzimologia , Permeabilidade Capilar , Ativação Enzimática , Fluorometria , Pulmão/enzimologia , Masculino , Pâncreas/patologia , Pancreatite/sangue , Pancreatite/patologia , Pancreatite/fisiopatologia , Circulação Pulmonar , Ratos , Ratos Sprague-Dawley , Índice de Gravidade de Doença , Irrigação Terapêutica
16.
Dev Genet ; 14(6): 449-59, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8111973

RESUMO

We have previously identified a 12 nucleotide long sequence element, the TCE, that was demonstrated to be necessary for translational control of expression in the male germ line of Drosophila melanogaster (Schäfer et al., 1990). It is conserved among all seven members of the Mst(3)CGP gene family, that encode structural proteins of the sperm tail. The TCE is invariably located in the 5' untranslated region (UTR) at position +28 relative to the transcription start site. In this paper we analyse the mode of action of this element. We show that protein binding occurs at the TCE after incubation with testis protein extracts from Drosophila melanogaster. While several proteins are associated with the translational control element in the RNA, only one of these proteins directly crosslinks to the sequence element. The binding activity is exclusively observed with testis protein extracts but can be demonstrated with testis extracts from other Drosophila species as well, indicating that regulatory proteins involved in translational regulation in the male germ line are conserved. Although binding to the TCE can occur independent of its position relative to the transcription start site of the in vitro transcripts, its function in vivo is not exerted when shifted further downstream within the 5' UTR of a fusion gene. In addition to being a translational control element the TCE also functions as a transcriptional regulator. Consequently, a DNA-protein complex is also formed at the TCE. In contrast to the RNA-protein complexes we find DNA-protein complexes with protein extracts of several tissues of Drosophila melanogaster.


Assuntos
Drosophila melanogaster/genética , Espermatogênese/genética , Animais , Sequência de Bases , Sítios de Ligação/genética , DNA/genética , Drosophila/genética , Drosophila melanogaster/crescimento & desenvolvimento , Feminino , Regulação da Expressão Gênica , Genes de Insetos , Masculino , Dados de Sequência Molecular , Família Multigênica , Ligação Proteica/genética , Biossíntese de Proteínas , Proteínas de Ligação a RNA/genética , Testículo/crescimento & desenvolvimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...