Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Diagnostics (Basel) ; 14(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38248061

RESUMO

The cellular-level visualization of retinal microstructures such as blood vessel wall components, not available with other imaging modalities, is provided with unprecedented details by dark-field imaging configurations; however, the interpretation of such images alone is sometimes difficult since multiple structural disturbances may be present in the same time. Particularly in eyes with retinal pathology, microstructures may appear in high-resolution retinal images with a wide range of sizes, sharpnesses, and brightnesses. In this paper we show that motion contrast and phase gradient imaging modalities, as well as the simultaneous acquisition of depth-resolved optical coherence tomography (OCT) images, provide additional insight to help understand the retinal neural and vascular structures seen in dark-field images and may enable improved diagnostic and treatment plans.

2.
Diagnostics (Basel) ; 13(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37998535

RESUMO

Diseases such as diabetes affect the retinal vasculature and the health of the neural retina, leading to vision problems. We describe here an imaging method and analysis procedure that enables characterization of the retinal vessel walls with cellular-level resolution, potentially providing markers for eye diseases. Adaptive optics scanning laser ophthalmoscopy is used with a modified detection scheme to include four simultaneous offset aperture channels. The magnitude of the phase gradient derived from these offset images is used to visualize the structural characteristics of the vessels. The average standard deviation image provides motion contrast and enables segmentation of the vessel lumen. Segmentation of blood vessel walls provides quantitative measures of geometrical characteristics of the vessel walls, including vessel and lumen diameters, wall thickness, and wall-to-lumen ratio. Retinal diseases may affect the structural integrity of the vessel walls, their elasticity, their permeability, and their geometrical characteristics. The ability to measure these changes is valuable for understanding the vascular effects of retinal diseases, monitoring disease progression, and drug testing. In addition, loss of structural integrity of the blood vessel wall may result in microaneurysms, a hallmark lesion of diabetic retinopathy, which may rupture or leak and further create vision impairment. Early identification of such structural abnormalities may open new treatment avenues for disease management and vision preservation. Functional testing of retinal circuitry through high-resolution measurement of vasodilation as a response to controlled light stimulation of the retina (neurovascular coupling) is another application of our method and can provide an unbiased evaluation of one's vision and enable early detection of retinal diseases and monitoring treatment results.

3.
Diagnostics (Basel) ; 13(13)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37443679

RESUMO

Adaptive optics provides improved resolution in ophthalmic imaging when retinal microstructures need to be identified, counted, and mapped. In general, multiple images are averaged to improve the signal-to-noise ratio or analyzed for temporal dynamics. Image registration by cross-correlation is straightforward for small patches; however, larger images require more sophisticated registration techniques. Strip-based registration has been used successfully for photoreceptor mosaic alignment in small patches; however, if the deformations along strips are not simple displacements, averaging can degrade the final image. We have applied a non-rigid registration technique that improves the quality of processed images for mapping cones over large image patches. In this approach, correction of local deformations compensates for local image stretching, compressing, bending, and twisting due to a number of causes. The main result of this procedure is improved definition of retinal microstructures that can be better identified and segmented. Derived metrics such as cone density, wall-to-lumen ratio, and quantification of structural modification of blood vessel walls have diagnostic value in many retinal diseases, including diabetic retinopathy and age-related macular degeneration, and their improved evaluations may facilitate early diagnostics of retinal diseases.

4.
Transl Biophotonics ; 4(3)2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36176918

RESUMO

Noninvasive assessment of skin lesions, especially of basal cell carcinoma (BCC), has benefited more recently from the use of optical imaging techniques such as optical coherence tomography (OCT) and reflectance confocal microscopy (RCM). While RCM provides submicron scale resolution and thus enables identification of skin morphological changes of the skin, with the downside of limited penetration depth, OCT imaging of the same lesion brings the benefit of better resolving its depth of invasion. OCT and RCM can be used either individually or combined within the same instrument for the noninvasive diagnosis of nonmelanoma skin cancers (NMSCs). Their combined use has shown to provide certain benefits such as better characterization of the lesion's margins, both in depth and laterally, as well as improved sensitivity and specificity, as previously demonstrated by our team. In this paper we report a new "fiber-based" implementation of the second-generation RCM-OCT hand-held probe. The fiber-based implementation of both imaging modalities enabled the construction of a smaller footprint/lower weight hand-held probe. Its preliminary evaluation on the skin of healthy volunteers is reported here, demonstrating improved capabilities for resolving sub-cellular structures and image skin morphology with micron-scale resolution to a higher depth than in the previous implementation, while also enabling the construction of angiography maps showing vascular remodeling.

5.
Biomed Opt Express ; 10(1): 167-180, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30775091

RESUMO

The platform described here combines the non-invasive measurement of the retina/choroid structure and ocular blood flow based on optical coherence tomography (OCT) and wide-field semi-quantitative global flow visualization using line-scanning Doppler flowmetry (LSDF). The combination of these two imaging modalities within the same platform enables comprehensive assessment of blood flow in the retina and choroid in animals and human subjects for diagnostic purposes. Ultra-widefield vasculature visualization is demonstrated here for the first time without injecting additional contrast agents and based only on the motion of particles within the vasculature.

6.
Invest Ophthalmol Vis Sci ; 57(2): 467-75, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26868749

RESUMO

PURPOSE: To study the density and packing geometry of the extrafoveal cone photoreceptors in eyes with a history of retinopathy of prematurity (ROP). We used a multimodal combination of adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). METHODS: Cones were identified in subjects (aged 14-26 years) with a history of ROP that was either severe and treated by laser ablation of avascular peripheral retina (TROP; n = 5) or mild and spontaneously resolved, untreated (UROP; n = 5), and in term-born controls (CT; n = 8). The AO-SLO images were obtained at temporal eccentricities 4.5°, 9°, 13.5°, and 18° using both confocal and offset apertures with simultaneous, colocal OCT images. Effects of group, eccentricity, and aperture were evaluated and the modalities compared. RESULTS: In the SLO images, cone density was lower and the packing pattern less regular in TROP, relative to CT and UROP retinae. Although SLO image quality appeared lower in TROP, root mean square (RMS) wavefront error did not differ among the groups. In TROP eyes, cone discrimination was easier in offset aperture images. There was no evidence of cone loss in the TROP OCT images. CONCLUSIONS: Low cone density in TROP confocal SLO images may have resulted from lower image quality. Since AO correction in these eyes was equivalent to that of the control group, and OCT imaging showed no significant cone loss, the optical properties of the inner retina or properties of the cones themselves are likely altered in a way that affects photoreceptor imaging.


Assuntos
Células Fotorreceptoras Retinianas Cones/patologia , Retinopatia da Prematuridade/diagnóstico , Adolescente , Adulto , Contagem de Células , Forma Celular , Feminino , Fóvea Central , Humanos , Masculino , Imagem Multimodal , Oftalmoscopia , Tomografia de Coerência Óptica , Adulto Jovem
7.
Opt Lett ; 38(22): 4558-61, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24322073

RESUMO

We present a new application of optical coherence tomography (OCT), widely used in biomedical imaging, to flow analysis in near-wall hydrodynamics for marine research. This unique capability, called OCT micro-particle image velocimetry, provides a high-resolution view of microscopic flow phenomena and measurement of flow statistics within the first millimeter of a boundary layer. The technique is demonstrated in a small flow cuvette and in a water tunnel.


Assuntos
Microscopia/instrumentação , Imagem Molecular/instrumentação , Reologia/instrumentação , Tomografia de Coerência Óptica/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Microesferas
8.
J Pharm Sci ; 102(6): 1773-1785, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23681564

RESUMO

The objective of this study was to assess the feasibility of developing and applying a laboratory tool that can provide three-dimensional product structural information during freeze-drying and which can accurately characterize the collapse temperature (Tc ) of pharmaceutical formulations designed for freeze-drying. A single-vial freeze dryer coupled with optical coherence tomography freeze-drying microscopy (OCT-FDM) was developed to investigate the structure and Tc of formulations in pharmaceutically relevant products containers (i.e., freeze-drying in vials). OCT-FDM was used to measure the Tc and eutectic melt of three formulations in freeze-drying vials. The Tc as measured by OCT-FDM was found to be predictive of freeze-drying with a batch of vials in a conventional laboratory freeze dryer. The freeze-drying cycles developed using OCT-FDM data, as compared with traditional light transmission freeze-drying microscopy (LT-FDM), resulted in a significant reduction in primary drying time, which could result in a substantial reduction of manufacturing costs while maintaining product quality. OCT-FDM provides quantitative data to justify freeze-drying at temperatures higher than the Tc measured by LT-FDM and provides a reliable upper limit to setting a product temperature in primary drying.


Assuntos
Liofilização/métodos , Microscopia/métodos , Tomografia de Coerência Óptica/métodos , Temperatura de Transição , Animais , Bovinos , Desenho de Equipamento , Liofilização/instrumentação , Microscopia/instrumentação , Soroalbumina Bovina/química , Sacarose/química , Tomografia de Coerência Óptica/instrumentação
9.
Biomed Opt Express ; 4(5): 680-95, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23667785

RESUMO

A combined high-resolution reflectance confocal microscopy (RCM)/optical coherence tomography (OCT) instrument for assessing skin burn gravity has been built and tested. This instruments allows for visualizing skin intracellular details with submicron resolution in the RCM mode and morphological and birefringence modifications to depths on the order of 1.2 mm in the OCT mode. Preliminary testing of the dual modality imaging approach has been performed on the skin of volunteers with some burn scars and on normal and thermally-injured Epiderm FTTM skin constructs. The initial results show that these two optical technologies have complementary capabilities that can offer the clinician a set of clinically comprehensive parameters: OCT helps to visualize deeper burn injuries and possibly quantify collagen destruction by measuring skin birefringence, while RCM provides submicron details of the integrity of the epidermal layer and identifies the presence of the superficial blood flow in the upper dermis. Therefore, the combination of these two technologies within the same instrument may provide a more comprehensive set of parameters that may help clinicians to more objectively and nonivasively assess burn injury gravity by determining tissue structural integrity and viability.

10.
Biomed Opt Express ; 3(4): 701-14, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-22574259

RESUMO

Blood flow in murine epicardial and intra-myocardial coronary arteries was measured in vivo with spectral domain optical Doppler tomography (SD-ODT). Videos at frame rates up to 180 fps were collected and processed to extract phase shifts associated with moving erythrocytes in the coronary arteries. Radial averaging centered on the vessel lumen provided spatial smoothing of phase noise in a single cross-sectional frame for instantaneous peak velocity measurement without distortion of the flow profile. Temporal averaging synchronized to the cardiac cycle (i.e., gating) was also performed to reduce phase noise, although resulting in lower flow profiles. The vessel angle with respect to incident imaging beam was measured with three-dimensional raster scans collected from the same region as the high speed cross-sectional scans. The variability in peak phase measurement was 10-15% from cycle to cycle on a single animal but larger for measurements among animals. The inter-subject variability is attributed to factors related to real physiological and anatomical differences, instrumentation variables, and measurement error. The measured peak instantaneous flow velocity in a ~40-µm diameter vessel was 23.5 mm/s (28 kHz Doppler phase shift). In addition to measurement of the flow velocity, we observed several dynamic features of the vessel and surrounding myocardium in the intensity and phase sequences, including asymmetric vessel deformation and rapid flow reversal immediately following maximum flow, in confirmation of known coronary artery flow dynamics. SD-ODT is an optical imaging tool that can provide in vivo measures of structural and functional information on cardiac function in small animals.

11.
Biomed Opt Express ; 3(1): 55-63, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22254168

RESUMO

A new type of freeze-drying microscope based upon time-domain optical coherence tomography is presented here (OCT-FDM). The microscope allows for real-time, in situ 3D imaging of pharmaceutical formulations in vials relevant for manufacturing processes with a lateral resolution of <7 µm and an axial resolution of <5 µm. Correlation of volumetric structural imaging with product temperature measured during the freeze-drying cycle allowed investigation of structural changes in the product and determination of the temperature at which the freeze-dried cake collapses. This critical temperature is the most important parameter in designing freeze-drying processes of pharmaceutical products.

12.
Biomed Opt Express ; 3(1): 178-91, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22254178

RESUMO

A new concept for cancer screening has been preliminarily investigated. A cancer targeting agent loaded with a near-infrared (NIR) dye was topically applied on the tissue to highlight cancer-suspect locations and guide optical coherence tomography (OCT) imaging, which was used to further investigate tissue morphology at the micron scale. A pilot study on ApcMin mice has been performed to preliminarily test this new cancer screening approach. As a cancer-targeting agent, poly(epsilon-caprolactone) microparticles (PCLMPs), labeled with a NIR dye and functionalized with an RGD (argenine-glycine-aspartic acid) peptide, were used. This agent recognizes the α(ν)ß(3) integrin receptor (ABIR), which is over-expressed by epithelial cancer cells. The contrast agent was administered topically in vivo in mouse colon. After incubation, the animals were sacrificed and fluorescence-guided high resolution optical coherence tomography (OCT) imaging was used to visualize colon morphology. The preliminary results show preferential staining of the abnormal tissue, as indicated by both microscopy and laser-induced fluorescence imaging, and OCT's capability to differentiate between normal mucosal areas, early dysplasia, and adenocarcinoma. Although very preliminary, the results of this study suggest that fluorescence-guided OCT imaging might be a suitable approach for cancer screening. If successful, this approach could be used by clinicians to more reliably diagnose early stage cancers in vivo.

13.
J Opt Soc Am A Opt Image Sci Vis ; 29(12): 2598-607, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23455909

RESUMO

Optical coherence tomography (OCT) and scanning laser ophthalmoscopy (SLO) are complementary imaging modalities, the combination of which can provide clinicians with a wealth of information to detect retinal diseases, monitor disease progression, or assess new therapies. Adaptive optics (AO) is a tool that enables correction of wavefront distortions from ocular aberrations. We have developed a multimodal adaptive optics system (MAOS) for high-resolution multifunctional use in a variety of research and clinical applications. The system integrates both OCT and SLO imaging channels into an AO beam path. The optics and hardware were designed with specific features for simultaneous SLO/OCT output, for high-fidelity AO correction, for use in humans, primates, and small animals, and for efficient location and orientation of retinal regions of interest. The MAOS system was tested on human subjects and rodents. The design, performance characterization, and initial representative results from the human and animal studies are presented and discussed.


Assuntos
Oftalmoscópios , Retina/citologia , Tomografia de Coerência Óptica/instrumentação , Adulto , Animais , Desenho de Equipamento , Humanos , Lasers , Ratos , Ratos Sprague-Dawley
14.
Biomed Opt Express ; 2(8): 2372-82, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21833374

RESUMO

We demonstrate for the first time that optical coherence tomography (OCT) imaging can reliably distinguish between morphologic features of low risk pancreatic cysts (i.e., pseudocysts and serous cystadenomas) and high risk pancreatic cysts (i.e., mucinous cystic neoplasms and intraductal papillary mucinous neoplasms). In our study fresh pancreatectomy specimens (66) from patients with cystic lesions undergoing surgery were acquired and examined with OCT. A training set of 20 pathology-OCT correlated tissue specimens were used to develop criteria for differentiating between low and high risk cystic lesions. A separate (validation) set of 46 specimens were used to test the OCT criteria by three clinicians, blinded to histopathology findings. Histology was finally used as a 'gold' standard for testing OCT findings. OCT was able to reveal specific morphologic features of pancreatic cysts and thus to differentiate between low-risk and high-risk cysts with over 95% sensitivity and specificity. This pilot study suggests that OCT could be used by clinicians in the future to more reliably differentiate between benign and potentially malignant pancreatic cysts. However, in vivo use of OCT requires a probe that has to fit the bore of the pancreas biopsy needle. Therefore, we have developed such probes and planned to start an in vivo pilot study within the very near future.

15.
ISRN Ophthalmol ; 2011: 146813, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-24527226

RESUMO

Purpose. To show how peripapillary spectral domain optical coherence tomography (SDOCT) retinal thickness (RT) maps can complement retinal nerve fiber layer (RNFL) thickness maps in the evaluation of glaucoma patients. Methods. After a complete eye exam with standard fundus photography and visual field testing, normal and glaucomatous eyes were imaged with an experimental SDOCT system. From SDOCT images, RNFL thickness and RT maps were constructed and then correlated with disc photography and visual field testing. Results. Two normal eyes of 2 patients and 5 eyes of 4 glaucoma patients were imaged. Although both RNFL and RT maps correlated well with visual field defects, glaucomatous arcuate defects were sometimes more easily identified in the RT maps. Conclusions. To our knowledge, this is the first paper to show that peripapillary SDOCT RT maps may provide important supplemental information to RNFL thickness maps in the evaluation of glaucoma patients.

16.
Nanomedicine (Lond) ; 5(9): 1467-79, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21128727

RESUMO

AIM: The goal of this research was to develop and preliminarily test a novel technology and instrumentation that could help to significantly increase the diagnostic yield of current colon cancer screening procedures. This technology is based on a combined fluorescence-optical coherence tomography (OCT) imaging, and topical delivery of a cancer-targeting agent. MATERIALS & METHODS: Gold colloid-adsorbed poly(ε-caprolactone) microparticles were labeled with a near-infrared dye, and functionalized with argentine-glycine-aspartic acid (RGD peptide) to effectively target cancer tissue, and enhance fluorescence-imaging contrast. The RGD peptide recognizes the α(v)ß(3)-integrin receptor, which is overexpressed by epithelial cancer cells. OCT was used under fluorescence guidance to visualize tissue morphology and, thus, to serve as a confirmatory tool for cancer presence. RESULTS: A preliminary testing of this technology on human colon cancer cell lines, a mouse model of colon cancer, as well as human colon tissue specimens, was performed. Strong binding of microparticles to cancer cells and no binding to cells that do not significantly express integrins, such as mouse fibroblasts, was observed. Preferential binding to cancer tissue was also observed. Strong fluorescence signals were obtained from cancer tissue, owing to the efficient binding of the contrast agent. OCT imaging was capable of revealing clear differences between normal and cancer tissue. CONCLUSION: A dual-modality imaging approach combined with topical delivery of a cancer-targeting contrast agent has been preliminarily tested for colon cancer diagnosis. Preferential binding of the contrast agent to cancer tissue allowed the cancer-suspicious locations to be highlighted and, thus, guided OCT imaging to visualize tissue morphology and determine tissue type. If successful, this multimodal approach might help to increase the sensitivity and the specificity of current colon cancer-screening procedures in the future.


Assuntos
Neoplasias do Colo/diagnóstico , Nanotecnologia/métodos , Adenocarcinoma/diagnóstico , Animais , Linhagem Celular Tumoral , Colo/patologia , Neoplasias do Colo/patologia , Meios de Contraste , Feminino , Ouro/química , Humanos , Técnicas In Vitro , Nanopartículas Metálicas/química , Camundongos , Camundongos Nus , Oligopeptídeos/química
17.
J Opt Soc Am A Opt Image Sci Vis ; 27(11): A265-77, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21045887

RESUMO

We have developed a new, unified implementation of the adaptive optics scanning laser ophthalmoscope (AOSLO) incorporating a wide-field line-scanning ophthalmoscope (LSO) and a closed-loop optical retinal tracker. AOSLO raster scans are deflected by the integrated tracking mirrors so that direct AOSLO stabilization is automatic during tracking. The wide-field imager and large-spherical-mirror optical interface design, as well as a large-stroke deformable mirror (DM), enable the AOSLO image field to be corrected at any retinal coordinates of interest in a field of >25 deg. AO performance was assessed by imaging individuals with a range of refractive errors. In most subjects, image contrast was measurable at spatial frequencies close to the diffraction limit. Closed-loop optical (hardware) tracking performance was assessed by comparing sequential image series with and without stabilization. Though usually better than 10 µm rms, or 0.03 deg, tracking does not yet stabilize to single cone precision but significantly improves average image quality and increases the number of frames that can be successfully aligned by software-based post-processing methods. The new optical interface allows the high-resolution imaging field to be placed anywhere within the wide field without requiring the subject to re-fixate, enabling easier retinal navigation and faster, more efficient AOSLO montage capture and stitching.


Assuntos
Lasers , Movimento (Física) , Oftalmoscópios , Fenômenos Ópticos , Retina/fisiologia , Integração de Sistemas , Adulto , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Software , Interface Usuário-Computador
18.
Opt Express ; 18(11): 11607-21, 2010 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-20589021

RESUMO

We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa. The SSOCT channel operates at a wavelength of 1 microm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. This AO system is designed for use in clinical populations; a dual deformable mirror (DM) configuration allows simultaneous low- and high-order aberration correction over a large range of refractions and ocular media quality. The system also includes a wide field (33 deg.) line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation, an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of lateral eye motion, and a high-resolution LCD-based fixation target for presentation of visual cues. The system was tested in human subjects without retinal disease for performance optimization and validation. We were able to resolve and quantify cone photoreceptors across the macula to within approximately 0.5 deg (approximately 100-150 microm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve features deep into the choroid. The prototype presented here is the first of a new class of powerful flexible imaging platforms that will provide clinicians and researchers with high-resolution, high performance adaptive optics imaging to help guide therapies, develop new drugs, and improve patient outcomes.


Assuntos
Lentes , Oftalmoscópios , Tomografia de Coerência Óptica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Microscopia Confocal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Opt Express ; 17(24): 21634-51, 2009 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-19997405

RESUMO

Various layers of the retina are well known to alter the polarization state of light. Such changes in polarization may be a sensitive indicator of tissue structure and function, and as such have gained increased clinical attention. Here we demonstrate a polarization-sensitive optical coherence tomography (PS-OCT) system that incorporates adaptive optics (AO) in the sample arm and a single line scan camera in the detection arm. We quantify the benefit of AO for PS-OCT in terms of signal-to-noise, lateral resolution, and speckle size. Double pass phase retardation per unit depth values ranging from 0.25 degrees/microm to 0.65 degrees/microm were found in the birefringent nerve fiber layer at 6 degrees eccentricity, superior to the fovea, with the highest values being noticeably higher than previously reported with PS-OCT around the optic nerve head. Moreover, fast axis orientation and degree of polarization uniformity measurements made with AO-PS-OCT demonstrate polarization scrambling in the retinal pigment epithelium at the highest resolution reported to date.


Assuntos
Disco Óptico/patologia , Óptica e Fotônica , Retina/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Algoritmos , Birrefringência , Desenho de Equipamento , Humanos , Oftalmologia/instrumentação , Oftalmologia/métodos , Refração Ocular , Epitélio Pigmentado da Retina/patologia
20.
J Biomed Opt ; 14(3): 034040, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19566332

RESUMO

An automated algorithm for differentiating breast tissue types based on optical coherence tomography (OCT) data is presented. Eight parameters are derived from the OCT reflectivity profiles and their means and covariance matrices are calculated for each tissue type from a training set (48 samples) selected based on histological examination. A quadratic discrimination score is then used to assess the samples from a validation set. The algorithm results for a set of 89 breast tissue samples were correlated with the histological findings, yielding specificity and sensitivity of 0.88. If further perfected to work in real time and yield even higher sensitivity and specificity, this algorithm would be a valuable tool for biopsy guidance and could significantly increase procedure reliability by reducing both the number of nondiagnostic aspirates and the number of false negatives.


Assuntos
Algoritmos , Neoplasias da Mama/patologia , Mama/citologia , Processamento de Sinais Assistido por Computador , Tomografia de Coerência Óptica/métodos , Tecido Adiposo/anatomia & histologia , Biópsia por Agulha Fina , Mama/patologia , Neoplasias da Mama/diagnóstico , Tomada de Decisões Assistida por Computador , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...