Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Mater Res B Appl Biomater ; 106(3): 1052-1063, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28500731

RESUMO

Di (2-ethylhexyl) phthalate (DEHP), a typical plasticizer used for polyvinyl chloride (PVC), is eluted from PVC-made blood containers and protects against red blood cell (RBC) hemolysis. However, concerns have arisen regarding the reproductive and developmental risks of DEHP in humans, and the use of alternative plasticizers for medical devices has been recommended worldwide. In this study, we propose that the use of a novel plasticizer, 4-cyclohexene-1,2-dicarboxylic acid dinonyl ester (DL9TH), could help produce more useful and safe blood containers. PVC sheet containing DL9TH and di (2-ethylhexyl) 4-cyclohexene-1,2-dicarboxylate (DOTH) provides comparable or superior protective effects to RBCs relative to PVC sheet containing DEHP or di-isononyl-cyclohexane-1,2-dicarboxylate (DINCH® , an alternative plasticizer that has been used in PVC sheets for blood containers). The total amount of plasticizer eluted from DOTH/DL9TH-PVC sheets is nearly the same as that eluted from DEHP-PVC sheets. In addition, DOTH/DL9TH-PVC has better cold resistance than DEHP- and DINCH® -PVC sheets. In vitro and in vivo tests for biological safety based on International Organization for Standardization guidelines (10993 series) suggest that the DOTH/DL9TH-PVC sheet can be used safely. Subchronic toxicity testing of DL9TH in male rats in accordance with the principles of Organisation for Economic Co-operation and Development Test Guideline 408 showed that DL9TH did not induce adverse effects up to the highest dose level tested (717 mg/kg body weight/day). There were no effects on testicular histopathology and sperm counts, and no indications of endocrine effects: testosterone, thyroid-stimulating hormone, follicle-stimulating hormone, and 17ß-estradiol were unchanged by the treatment, compared with the control group. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1052-1063, 2018.


Assuntos
Preservação de Sangue/métodos , Cicloexenos/química , Eritrócitos/química , Ésteres/química , Plastificantes/química , Embalagem de Produtos , Animais , Sobrevivência Celular/efeitos dos fármacos , Temperatura Baixa , Cicloexenos/efeitos adversos , Dietilexilftalato/química , Dietilexilftalato/farmacologia , Eritrócitos/efeitos dos fármacos , Ésteres/efeitos adversos , Cobaias , Hemólise/efeitos dos fármacos , Masculino , Plastificantes/efeitos adversos , Cloreto de Polivinila/química , Cloreto de Polivinila/farmacologia , Coelhos , Ratos , Resistência à Tração
2.
PLoS One ; 12(9): e0185737, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28957448

RESUMO

Di (2-ethylhexyl) phthalate (DEHP), a typical plasticizer used for polyvinyl chloride (PVC) blood containers, is eluted from the blood containers and exerts protective effects on red blood cells. However, a concern for detrimental effects of DEHP on human health has led to the development of potential DEHP substitutes. Here, we compared the red blood cell preservation ability of two types of non-DEHP blood containers with safe alternative plasticizers to that of DEHP blood containers. Red cell concentrates in mannitol-adenine-phosphate solution (MAP/RCC) were stored for 6 weeks in PVC blood bags containing DEHP, di-isononyl-cyclohexane-1,2-dicarboxylate (DINCH) and di (2-ethylhexyl) 4-cyclohexene-1,2-dicarboxylate (DOTH), or 4-cyclohexene-1,2-dicarboxylic acid dinonyl ester (DL9TH) and DOTH. There was no significant difference in the total amount of plasticizer eluted into MAP/RCC (till 3 weeks from the beginning of the experiment), hemolysis of MAP/RCC, and osmotic fragility of MAP/RCC between the non-DEHP blood containers and DEHP blood containers. Hematological and blood chemical indices of MAP/RCC in all containers were nearly the same. Thus, DOTH/DINCH and DOTH/DL9TH blood containers demonstrate the same quality of MAP/RCC storing as the DEHP blood containers. Since DOTH, DINCH, and DL9TH were reported to be safe, DOTH/DINCH and DOTH/DL9TH blood containers are promising candidate substitutes for DEHP blood containers.


Assuntos
Preservação de Sangue/métodos , Equipamentos e Provisões , Eritrócitos/metabolismo , Plastificantes/química , Humanos , Projetos Piloto
3.
J Biomed Mater Res B Appl Biomater ; 102(4): 674-80, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24616166

RESUMO

Accordion nerve conduit of poly(lactide-co-glycolide-co-ε-caprolactone) with perforations was developed by excimer laser processing. We evaluated its in vivo function for nerve repairing and discussed the influence of pore size and density. It was found that perforations help inner nerve regeneration remarkably, which effect is unrelated to pore size or density, and is not parallel with revascularization increment. Inducing of permeability only to allow substance exchange but not vessel ingrowth could facilitate nerve regeneration too. Perforating micropores with the size of 100 µm and the density of 25/cm provides permeability and vessel ingrowth both, therefore promotes the axon extension the best, larger, and more pores do not advance axon regeneration more.


Assuntos
Implantes Absorvíveis , Regeneração Tecidual Guiada/instrumentação , Regeneração Nervosa , Poliésteres , Próteses e Implantes , Alicerces Teciduais , Animais , Materiais Biocompatíveis , Implantes Experimentais , Lasers , Masculino , Microscopia Eletrônica de Varredura , Neovascularização Fisiológica , Porosidade , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/irrigação sanguínea , Nervo Isquiático/fisiologia , Nervo Isquiático/cirurgia , Nervo Isquiático/ultraestrutura , Cicatrização
4.
Microsurgery ; 30(6): 494-501, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20238380

RESUMO

Although the devices for large-caliber vessel (>2-mm diameter) anastomosis are available, there are no devices for performing anastomosis of small-caliber vessels. We designed a hooked device composed of a bioabsorbable polymer for sutureless anastomosis of small-caliber vessels. The efficacy of this device was evaluated by in vitro degradation and arterial-fixation strength tests as well as in vivo transplantation experiments with common carotid arteries of growing SD rats. A nonabsorbable device without hooks served as the control in the fixation strength and animal experiments. The tensile strength of the bioabsorbable device decreased to 27 and 9% of the initial value after 8- and 24-week incubation, respectively. The fixation strength was greater and the anastomotic time was shorter with this device than with the control. The transplantation experiments showed complete endothelial bridging in both devices at 2 weeks after surgery (n = 6). The control device created a considerable protrusion into the arterial lumen at 8 postoperative weeks, whereas the experimental device did not (n = 6). Arterial diameter measurements detected a significant difference between the inner diameters at the respective anastomotic sites (n = 6, P < 0.05) and demonstrated that the control device hindered the vessel growth while the experimental device did not. Therefore, the bioabsorbable hooked device was an effective tool for anastomosis of small-caliber arteries (ca. 1-mm diameter).


Assuntos
Anastomose Cirúrgica/instrumentação , Microcirurgia/instrumentação , Implantes Absorvíveis , Animais , Artérias/anatomia & histologia , Desenho de Equipamento , Masculino , Ratos , Ratos Sprague-Dawley , Técnicas de Sutura/instrumentação , Resistência à Tração , Grau de Desobstrução Vascular
5.
Artif Organs ; 32(6): 473-83, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18422798

RESUMO

We have developed novel watertight and bioabsorbable synthetic dural substitutes. The substitutes were designed such that they had a three-layered structure, and each layer comprised a bioabsorbable copolymer prepared from L-lactide, glycolide, and epsilon-caprolactone. Various copolymers were synthesized, and appropriate compositions were selected for preparing the substitutes based on the results of leakage tests. Experimental substitutes that prevented the leakage of saline through the suture lines between the substitutes and dura mater were prepared. An in vitro study was performed in which the substitutes were sutured to porcine dura mater, and the amount of saline leakage was measured. It was demonstrated that leakage through the suture line could be completely suppressed by using the substitutes we developed along with favorable suturing techniques.


Assuntos
Implantes Absorvíveis , Dura-Máter/fisiologia , Poliésteres/química , Animais , Materiais Biocompatíveis/química , Elasticidade , Porosidade , Sus scrofa , Técnicas de Sutura , Suturas , Viscosidade
6.
Artif Organs ; 31(7): 500-8, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17584474

RESUMO

Nerve conduit tubes were developed using bioabsorbable polymer membranes, and the effects of tube shape--straight or bellows-shaped tubes--and the fibrin gel filling were investigated. The mechanical properties of the tubes were examined by in vitro tests, and their effectiveness for peripheral nerve regeneration was determined by grafting into experimentally transected sciatic nerves of rats. The bellows tube showed mechanically superior properties, and when used with the fibrin gel, it induced superior tissue formation of myelinated nerve fibers as compared to other tube types. The total area of myelinated axons regenerated in the fibrin-filled bellows tube was comparable to that of an isograft control, whereas those of the other tubes demonstrated inferior regeneration. This result suggests that the mechanically superior bellows tube filled with fibrin gel is an effective graft alternative for peripheral nerve regeneration.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis/uso terapêutico , Fibrina/uso terapêutico , Regeneração Nervosa/fisiologia , Poliésteres/uso terapêutico , Nervo Isquiático/fisiologia , Animais , Fenômenos Biomecânicos , Masculino , Teste de Materiais , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/patologia
7.
J Nanosci Nanotechnol ; 7(3): 730-3, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17450824

RESUMO

We developed two types of nerve conduits, straight tubes, and bellows tubes, for peripheral nerve regeneration with bioabsorbable polymer membranes. Mechanical properties of these straight and bellows tubes were analyzed. 30 straight tubes and 30 bellows tubes were implanted to a nerve defect made in a rat sciatic nerve and the nerve regeneration in the tube was investigated. A half of these tubes were utilized alone and the others were filled with fibrin gel made from coagulated plasma and implanted. Bellows tubes were superior in mechanical characteristics to straight tubes and the inner cavities of the bellows tubes were suitably maintained after implantation. At 4 weeks after operations, remyelinations were observed in the regenerated tissue at the location of the middle parts of the tubes filled with fibrin gel whereas no remyelinations in the tubes without fibrin gel. The use of fibrin gel as filling materials within the tubes significantly enhanced the nerve regeneration. The fibrin gel might be soft nanomaterials significantly enhance the regeneration of the peripheral nerves. We concluded that the developed bioabsorbable bellows tubes filled with fibrin gel were effective for peripheral nerve regeneration.


Assuntos
Regeneração Nervosa , Animais , Materiais Biocompatíveis , Fenômenos Biomecânicos , Fibrina , Géis , Masculino , Teste de Materiais , Nanotecnologia , Nanotubos , Regeneração Nervosa/efeitos dos fármacos , Polímeros , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/efeitos dos fármacos , Nervo Isquiático/lesões , Nervo Isquiático/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...