JACC Clin Electrophysiol ; 9(12): 2665-2679, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37737780

RESUMO

Cardiac magnetic resonance (CMR) imaging is a valuable noninvasive tool for evaluating tissue response following catheter ablation of atrial tissue. This review provides an overview of the contemporary CMR strategies to visualize atrial ablation lesions in both the acute and chronic postablation stages, focusing on their strengths and limitations. Moreover, the accuracy of CMR imaging in comparison to atrial lesion histology is discussed. T2-weighted CMR imaging is sensitive to edema and tends to overestimate lesion size in the acute stage after ablation. Noncontrast agent-enhanced T1-weighted CMR imaging has the potential to provide more accurate assessment of lesions in the acute stage but may not be as effective in the chronic stage. Late gadolinium enhancement imaging can be used to detect chronic atrial scarring, which may inform repeat ablation strategies. Moreover, novel imaging strategies are being developed, but their efficacy in characterizing atrial lesions is yet to be determined. Overall, CMR imaging has the potential to provide virtual histology that aids in evaluating the efficacy and safety of catheter ablation and monitoring of postprocedural myocardial changes. However, technical factors, scanning during arrhythmia, and transmurality assessment pose challenges. Therefore, further research is needed to develop CMR strategies to visualize the ablation lesion maturation process more effectively.


Assuntos
Ablação por Cateter , Meios de Contraste , Humanos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos , Espectroscopia de Ressonância Magnética
2.
Int J Cardiovasc Imaging ; 39(9): 1753-1763, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37515682

RESUMO

PURPOSE: Left atrial (LA) sphericity is a novel, geometry-based parameter that has been used to visualize and quantify LA geometrical remodeling in patients with atrial fibrillation (AF). This study examined the association between LA sphericity, and LA longitudinal strain and strain rate measured by feature-tracking in AF patients. METHODS: 128 AF patients who underwent cardiovascular magnetic resonance (CMR) imaging in sinus rhythm prior to their pulmonary vein isolation (PVI) procedure were retrospectively analyzed. LA sphericity was calculated by segmenting the LA (excluding the pulmonary veins and the LA appendage) on a 3D contrast enhanced MR angiogram and comparing the resulting shape with a perfect sphere. LA global reservoir strain, conduit strain, contractile strain and corresponding strain rates were derived from cine images using feature-tracking. For statistical analysis, Pearson correlations, multivariable logistic regression analysis, and Student t-tests were used. RESULTS: Patients with a spherical LA (dichotomized by the median value) had a lower reservoir strain and conduit strain compared to patients with a non-spherical LA (-15.4 ± 4.2% vs. -17.1 ± 3.5%, P = 0.02 and - 8.2 ± 3.0% vs. -9.5 ± 2.6%, P = 0.01, respectively). LA strain rate during early ventricular diastole was also different between both groups (-0.7 ± 0.3s- 1 vs. -0.9 ± 0.3s- 1, P = 0.001). In contrast, no difference was found for LA contractile strain (-7.2 ± 2.6% vs. -7.6 ± 2.2%, P = 0.30). CONCLUSIONS: LA passive strain is significantly impaired in AF patients with a spherical LA, though this relation was not independent from LA volume.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Valor Preditivo dos Testes , Átrios do Coração , Ablação por Cateter/métodos
3.
J Am Heart Assoc ; 12(15): e028014, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37489727

RESUMO

Background Among patients with an implantable cardioverter-defibrillator, a high prevalence of atrial fibrillation (AF) is present. Identification of AF predictors in this patient group is of clinical importance to initiate appropriate preventive therapeutic measures to reduce the risk of AF-related complications. This study assesses whether cardiac magnetic resonance imaging-derived atrial characteristics are associated with AF development in patients with a dual-chamber implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, as detected by the cardiac implantable electronic device. Methods and Results This single-center retrospective study included 233 patients without documented AF history at the moment of device implantation (dual-chamber implantable cardioverter-defibrillator [63.5%] or cardiac resynchronization therapy defibrillator [36.5%]). All patients underwent cardiac magnetic resonance imaging before device implantation. Cardiac magnetic resonance-derived features of left atrial (LA) remodeling were evaluated in all patients. Detection of AF episodes was based on cardiac implantable electronic device interrogation. During a median follow-up of 6.1 years, a newly diagnosed AF episode was detected in 88 of the 233 (37.8%) patients with an ICD. In these patients, increased LA volumes and impaired LA function (LA emptying fraction and LA strain) were found as compared with patients without AF during follow-up. However, a significant association was only found in patients with dilated cardiomyopathy and not in patients with ischemic cardiomyopathy. Conclusions LA remodeling characteristics were associated with development of AF in patients with dilated cardiomyopathy but not patients with ischemic cardiomyopathy, suggesting different mechanisms of AF development in ischemic cardiomyopathy and dilated cardiomyopathy. Assessment of LA remodeling before device implantation might identify high-risk patients for AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Isquemia Miocárdica , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Cardiomiopatia Dilatada/etiologia , Isquemia Miocárdica/etiologia , Imageamento por Ressonância Magnética
4.
J Clin Med ; 12(12)2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37373691

RESUMO

OBJECTIVES: This prospective pilot study assessed the feasibility of cardiovascular magnetic resonance (CMR) imaging during biventricular (BIV) pacing in patients with a CMR conditional cardiac resynchronization therapy defibrillator (CRT-D) and compared the results with invasive volume measurements. METHODS: Ten CRT-D patients underwent CMR imaging prior to device implantation (baseline) and six weeks after device implantation, including CRT-on and CRT-off modes. Left ventricular (LV) function, volumes, and strain measurements of LV dyssynchrony and dyscoordination were assessed. Invasive pressure-volume measurements were performed, matching the CRT settings used during CMR. RESULTS: Post-implantation imaging enabled reliable cine assessment, but showed artefacts on late gadolinium enhancement images. After six weeks of CRT, significant reverse remodeling was observed, with a 22.7 ± 11% reduction in LV end-systolic volume during intrinsic rhythm (CRT-off). During CRT-on, the LV ejection fraction significantly improved from 27.4 ± 5.9% to 32.2 ± 8.7% (p < 0.01), and the strain assessment showed the abolition of the left bundle branch block contraction pattern. Invasively measured and CMR-assessed LV hemodynamics during BIV pacing were significantly associated. CONCLUSIONS: Post-CRT implantation CMR assessing acute LV pump function is feasible and provides important insights into the effects of BIV pacing on cardiac function and contraction patterns. LV assessment during CMR may constitute a future CRT optimization strategy.

5.
Int J Cardiol ; 378: 23-31, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36804765

RESUMO

PURPOSE: The present study assesses different left atrial (LA) strain approaches in relation to atrial fibrillation (AF) recurrence after ablation and compares LA feature tracking (FT) strain to novel rapid LA strain approaches in AF patients. METHODS: This retrospective single-center study comprised of 110 prospectively recruited AF patients who underwent cardiac magnetic resonance (CMR) imaging in sinus rhythm prior to their first pulmonary vein isolation ablation. LA rapid strain (long axis strain and atrioventricular (AV)-junction strain), LA FT strain, and LA volumes were derived from 2-chamber and 4-chamber cine images. AF recurrence was followed up for 12 months using either 12­lead ECGs or rhythm Holter monitoring. RESULTS: Arrhythmia recurrence was observed in 39 patients (36%) after the 90-day blanking period, occurring at a median of 181 (122-286) days. LA long axis strain, AV-junction strain, and FT strain were all more impaired in patients with AF recurrence compared to patients without AF recurrence (long axis strain: P < 0.01; AV-junction strain: P < 0.001; FT strain: P < 0.01, respectively). Area under the curve (AUC) values for LA remodeling parameters in association with AF recurrence were 0.68 for long axis strain, 0.68 for AV-junction strain, 0.66 for FT strain, 0.66 for LA volume index. Phasic FT LA strain demonstrated that contractile strain had the highest AUC (0.70). CONCLUSION: Both LA rapid strain and LA FT strain are associated with arrhythmia recurrence after ablation in AF patients. LA rapid strain can be a convenient and reproducible alternative for LA FT strain to assess LA function in clinical practice.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Estudos Retrospectivos , Valor Preditivo dos Testes , Átrios do Coração , Espectroscopia de Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
6.
Eur Heart J Cardiovasc Imaging ; 24(3): 336-345, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-35921538

RESUMO

AIMS: Bi-atrial remodelling in patients with atrial fibrillation (AF) is rarely assessed and data on the presence of right atrial (RA) fibrosis, the relationship between RA and left atrial (LA) fibrosis, and possible association of RA remodelling with AF recurrence after ablation in patients with AF is limited. METHODS AND RESULTS: A total of 110 patients with AF undergoing initial pulmonary vein isolation (PVI) were included in the present study. All patients were in sinus rhythm during cardiac magnetic resonance (CMR) imaging performed prior to ablation. LA and RA volumes and function (volumetric and feature tracking strain) were derived from cine CMR images. The extent of LA and RA fibrosis was assessed from 3D late gadolinium enhancement images. AF recurrence was followed up for 12 months after PVI using either 12-lead electrocardiograms or Holter monitoring. Arrhythmia recurrence was observed in 39 patients (36%) after the 90-day blanking period, occurring at a median of 181 (interquartile range: 122-286) days. RA remodelling parameters were not significantly different between patients with and without AF recurrence after ablation, whereas LA remodelling parameters were different (volume, emptying fraction, and strain indices). LA fibrosis had a strong correlation with RA fibrosis (r = 0.88, P < 0.001). Both LA and RA fibrosis were not different between patients with and without AF recurrence. CONCLUSIONS: This study shows that RA remodelling parameters were not predictive of AF recurrence after AF ablation. Bi-atrial fibrotic remodelling is present in patients with AF and moreover, the amount of LA fibrosis had a strong correlation with the amount of RA fibrosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Meios de Contraste , Função do Átrio Direito , Gadolínio , Átrios do Coração , Fibrose , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
7.
Eur Heart J Cardiovasc Imaging ; 23(9): 1182-1190, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-35947873

RESUMO

AIMS: Various methods and post-processing software packages have been developed to quantify left atrial (LA) fibrosis using 3D late gadolinium-enhancement cardiac magnetic resonance (LGE-CMR) images. Currently, it remains unclear how the results of these methods and software packages interrelate. METHODS AND RESULTS: Forty-seven atrial fibrillation (AF) patients underwent 3D-LGE-CMR imaging prior to their AF ablation. LA fibrotic burden was derived from the images using open-source CEMRG software and commercially available ADAS 3D-LA software. Both packages were used to calculate fibrosis based on the image intensity ratio (IIR)-method. Additionally, CEMRG was used to quantify LA fibrosis using three standard deviations (3SD) above the mean blood pool signal intensity. Intraclass correlation coefficients were calculated to compare LA fibrosis quantification methods and different post-processing software outputs. The percentage of LA fibrosis assessed using IIR threshold 1.2 was significantly different from the 3SD-method (29.80 ± 14.15% vs. 8.43 ± 5.42%; P < 0.001). Correlation between the IIR-and SD-method was good (r = 0.85, P < 0.001) although agreement was poor [intraclass correlation coefficient (ICC) = 0.19; P < 0.001]. One-third of the patients were allocated to a different fibrosis category dependent on the used quantification method. Fibrosis assessment using CEMRG and ADAS 3D-LA showed good agreement for the IIR-method (ICC = 0.93; P < 0.001). CONCLUSIONS: Both, the IIR1.2 and 3SD-method quantify atrial fibrotic burden based on atrial wall signal intensity differences. The discrepancy in the amount of LA fibrosis between these methods may have clinical implications when patients are classified according to their fibrotic burden. There was no difference in results between post-processing software packages to quantify LA fibrosis if an identical quantification method including the threshold was used.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
8.
Radiol Cardiothorac Imaging ; 4(1): e210192, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35795718

RESUMO

Purpose: To determine whether the distance between the descending aorta and left atrial (LA) wall correlates with the amount of fibrosis quantified in the posterior left inferior pulmonary vein (LIPV) area of the LA in patients with atrial fibrillation (AF). Materials and Methods: In this retrospective study, patients with AF underwent cardiac MRI in sinus rhythm prior to a pulmonary vein isolation procedure (July 2018 to February 2020). The mean distance (distancemean) and shortest distance (distanceshort) between the descending aorta and the LA wall were measured on three-dimensional (3D) contrast-enhanced MR angiograms; distancemean was defined as the average of five measurements at different levels between the descending aorta and the LA wall. The extent of LA fibrosis, both global fibrosis and regional fibrosis within the LIPV area, was derived from postprocessed, 3D, late gadolinium-enhanced images. Associations between the extent of fibrosis and the proximity of the descending aorta were analyzed by using correlative and multivariable analyses. Results: A total of 47 (mean age, 60 years ± 8 [standard deviation]; 31 men) patients were included for analysis. The extent of fibrosis in the posterior LIPV area was correlated with the distancemean (r s = -0.48; P < .01) and distanceshort (r s = -0.49; P < .01). Patients with a short distance between the descending aorta and LA wall (defined as a distanceshort < 2 mm) had a higher percentage of fibrosis in the posterior LIPV area than patients with a distanceshort greater than 2 mm (38.7% ± 22.7 vs 21.2% ± 17.8; P < .01). Conclusion: The distance between the descending aorta and LA was correlated with the extent of quantified fibrosis within the posterior LIPV area.Keywords: MRI, Cardiac, Left Atrium Supplemental material is available for this article. © RSNA, 2022.

9.
J Cardiovasc Electrophysiol ; 33(5): 885-896, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35257441

RESUMO

INTRODUCTION: Approximately 18% of patients with atrial fibrillation (AF) undergo a repeat ablation within 12 months after their index ablation. Despite the high prevalence, comparative studies on nonpulmonary vein (PV) target strategies in repeat AF ablation are scarce. Here, we describe 12 months efficacy of non-PV and PV target ablations as a repeat ablation strategy. METHODS: A multicentre retrospective, descriptive study was conducted with data of 280 patients who underwent repeat AF ablation. The ablation strategy for repeat ablation was at the operators' discretion. Non-PV target ablation (n = 140) included PV reisolation, posterior wall isolation, mitral line, roofline, and/or complex fractionated atrial electrogram ablation. PV target ablation (n = 140), included reisolation and/or wide atrium circumferential ablation. Patients' demographics and rhythm outcomes during 12 months follow-up were analyzed. RESULTS: At 12 months, more atrial tachyarrhythmias were observed in the non-PV target group (48.6%) compared to the PV target group (29.3%, p = .001). Similarly, a significantly higher AF and atrial tachycardia (AT) recurrence rate was observed after non-PV target ablation compared to PV target ablation (36.4% vs. 22.1% and 22.9% vs. 10.7%). After adjustment, a significantly higher risk of AT recurrence remained in the non-PV target group. Both groups significantly de-escalated antiarrhythmic drug use; de-escalation was more profound after PV target ablation. Patients with isolated PVs during non-PV target ablation had a significantly higher risk for AF recurrence than those with reconnected PVs. CONCLUSION: Compared to PV target ablation, non-PV target repeat ablation did not improve outcomes after 12 months and was independently associated with an increased risk for AT recurrences.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 33(1): 64-72, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34820931

RESUMO

INTRODUCTION: Radiofrequency (RF) atrial fibrillation (AF) ablation using a catheter dragging technique may shorten procedural duration and improve durability of pulmonary vein isolation (PVI) by creating uninterrupted linear ablation lesions. We compared a novel AF ablation approach guided by Grid annotation allowing for "drag lesions" with a standard point-by-point ablation approach in a single-center randomized study. METHODS: Eighty-eight paroxysmal or persistent AF patients were randomized 1:1 to undergo RF-PVI with either a catheter dragging ablation technique guided by Grid annotation or point-by-point ablation guided by Ablation Index (AI) annotation. In the Grid annotation arm, ablation was visualized using 1 mm³ grid points coloring red after meeting predefined stability and contact force criteria. In the AI annotation arm, ablation lesions were created in a point-by-point fashion with AI target values set at 380 and 500 for posterior/inferior and anterior/roof segments, respectively. Patients were followed up for 12 months after PVI using ECGs, 24-h Holter monitoring and a mobile-based one-lead ECG device. RESULTS: Procedure time was not different between the two randomization arms (Grid annotation 71 ± 19 min, AI annotation 72 ± 26 min, p = .765). RF time was significantly longer in the Grid annotation arm compared with the AI annotation arm (49 ± 8 min vs. 37 ± 8 min, respectively, p < .001). Atrial tachyarrhythmia recurrence was documented in 10 patients (23%) in the Grid annotation arm compared with 19 patients (42%) in the AI annotation arm with time to recurrence not reaching statistical significance (p = .074). CONCLUSIONS: This study shows that a Grid annotation-guided dragging approach provides an alternative to point-by-point RF-PVI using AI annotation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
Europace ; 24(6): 874-886, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34964469

RESUMO

Pulmonary vein isolation (PVI) by radiofrequency (RF) ablation is an important alternative to antiarrhythmic drugs in the treatment of symptomatic atrial fibrillation. However, the inability to consistently achieve durable isolation of the pulmonary veins hampers the long-term efficacy of PVI procedures. The large number of factors involved in RF lesion formation and the complex interplay of these factors complicate reliable creation of durable and transmural ablation lesions. Various surrogate markers of ablation lesion formation have been proposed that may provide information on RF lesion completeness. Real-time assessment of these surrogates may aid in the creation of transmural ablation lesions, and therefore, holds potential to decrease the risk of PV reconnection and consequent post-PVI arrhythmia recurrence. Moreover, titration of energy delivery until lesions is transmural may prevent unnecessary ablation and subsequent adverse events. Whereas several surrogate markers of ablation lesion formation have been described over the past decades, a 'gold standard' is currently lacking. This review provides a state-of-the-art overview of ablation strategies that aim to enhance durability of RF-PVI, with special focus on real-time available surrogates of RF lesion formation in light of the biophysical basis of RF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Antiarrítmicos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
12.
J Cardiovasc Magn Reson ; 23(1): 131, 2021 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-34758820

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with profound structural and functional changes in the atria. In the present study, we investigated the association between left atrial (LA) phasic function and the extent of LA fibrosis using advanced cardiovascular magnetic resonance (CMR) imaging techniques, including 3-dimensional (3D) late gadolinium enhancement (LGE) and feature tracking. METHODS: Patients with paroxysmal and persistent AF (n = 105) underwent CMR in sinus rhythm. LA global reservoir strain, conduit strain and contractile strain were derived from cine CMR images using CMR feature tracking. The extent of LA fibrosis was assessed from 3D LGE images. Healthy subjects underwent CMR and served as controls (n = 19). RESULTS: Significantly lower LA reservoir strain, conduit strain and contractile strain were found in AF patients, as compared to healthy controls (- 15.9 ± 3.8% vs. - 21.1 ± 3.6% P < 0.001, - 8.7 ± 2.7% vs. - 12.6 ± 2.5% P < 0.001 and - 7.2 ± 2.3% vs. - 8.6 ± 2.2% P = 0.02, respectively). Patients with a high degree of LA fibrosis (dichotomized by the median value) had lower reservoir strain and conduit strain compared to patients with a low degree of LA fibrosis (- 15.0 ± 3.9% vs. - 16.9 ± 3.3%, P = 0.02 and - 7.9 ± 2.7% vs. - 9.5 ± 2.6%, P = 0.01, respectively). In contrast, no difference was found for LA contractile strain (- 7.1 ± 2.4% vs. - 7.4 ± 2.3%, P = 0.55). CONCLUSIONS: Impaired LA reservoir and conduit strain are present in AF patients with extensive atrial fibrosis. Future studies are needed to examine the biologic nature of this association and possible therapeutic implications.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico por imagem , Meios de Contraste , Fibrose , Gadolínio , Humanos , Valor Preditivo dos Testes
13.
Int J Cardiol ; 344: 103-110, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34555444

RESUMO

BACKGROUND: A significant number of patients experience recurrent atrial fibrillation (AF) after ablation. Various risk scores have been described that may predict outcomes after AF ablation. In this study, we aimed to compare ten previously described risk scores with regard to their predictive value for post-ablation AF recurrence and procedural complications. METHODS: A total of 482 AF patients (63% paroxysmal AF, 66% male, mean age 62 ± 9 years) undergoing initial radiofrequency pulmonary vein isolation (PVI) were included in the present analysis. Prior to ablation, all patients underwent both transthoracic echocardiography (TTE) and either cardiac CT imaging or CMR imaging. The following risk scores were calculated for each patient: APPLE, ATLAS, BASE-AF2, CAAP-AF, CHADS2, CHA2DS2-VASc, DR-FLASH, HATCH, LAGO and MB-LATER. RESULTS: Median follow-up was 16 (12-31) months. AF recurrence after a 90-day blanking period was observed in 199 patients (41%), occurring after a median of 183 (124-360) days. AF recurrence was less frequent in paroxysmal AF patients compared to non-paroxysmal AF patients (34% vs. 54%, p < 0.001). Overall periprocedural complication rate was 6%. All scores, except the HATCH score, demonstrated statistically significant but poor predictive value for recurrent AF after ablation (area under curve [AUC] 0.553-0.669). CHA2DS2-VASc and CAAP-AF were the only risk scores with predictive value for procedural complications (AUC 0.616, p = 0.043; AUC 0.615, p = 0.044; respectively). CONCLUSIONS: Currently available risk scores perform poorly in predicting outcomes after AF ablation. These data suggest that the utility of these scores for clinical decision-making is limited.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Medição de Risco , Fatores de Risco , Resultado do Tratamento
14.
Sci Rep ; 11(1): 5965, 2021 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-33727587

RESUMO

The pathophysiology behind thrombus formation in paroxysmal atrial fibrillation (AF) patients is very complex. This can be due to left atrial (LA) flow changes, remodeling, or both. We investigated differences for cardiovascular magnetic resonance (CMR)-derived LA 4D flow and remodeling characteristics between paroxysmal AF patients and patients without cardiac disease. In this proof-of-concept study, the 4D flow data were acquired in 10 patients with paroxysmal AF (age = 61 ± 8 years) and 5 age/gender matched controls (age = 56 ± 1 years) during sinus rhythm. The following LA and LA appendage flow parameters were obtained: flow velocity (mean, peak), stasis defined as the relative volume with velocities < 10 cm/s, and kinetic energy (KE). Furthermore, LA global strain values were derived from b-SSFP cine images using dedicated CMR feature-tracking software. Even in sinus rhythm, LA mean and peak flow velocities over the entire cardiac cycle were significantly lower in paroxysmal AF patients compared to controls [(13.1 ± 2.4 cm/s vs. 16.7 ± 2.1 cm/s, p = 0.01) and (19.3 ± 4.7 cm/s vs. 26.8 ± 5.5 cm/s, p = 0.02), respectively]. Moreover, paroxysmal AF patients expressed more stasis of blood than controls both in the LA (43.2 ± 10.8% vs. 27.8 ± 7.9%, p = 0.01) and in the LA appendage (73.3 ± 5.7% vs. 52.8 ± 16.2%, p = 0.04). With respect to energetics, paroxysmal AF patients demonstrated lower mean and peak KE values (indexed to maximum LA volume) than controls. No significant differences were observed for LA volume, function, and strain parameters between the groups. Global LA flow dynamics in paroxysmal AF patients appear to be impaired including mean/peak flow velocity, stasis fraction, and KE, partly independent of LA remodeling. This pathophysiological flow pattern may be of clinical value to explain the increased incidence of thromboembolic events in paroxysmal AF patients, in the absence of actual AF or LA remodeling.


Assuntos
Fibrilação Atrial/diagnóstico , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Hemodinâmica , Imageamento Tridimensional , Fibrilação Atrial/complicações , Fibrilação Atrial/etiologia , Remodelamento Atrial , Velocidade do Fluxo Sanguíneo , Gerenciamento Clínico , Suscetibilidade a Doenças , Eletrocardiografia , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Tromboembolia/etiologia
15.
Int J Cardiol Heart Vasc ; 29: 100574, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32642554

RESUMO

BACKGROUND: Although Ablation Index (AI)-guided ablation facilitates creation of lesions of consistent depth, pulmonary vein (PV) reconnection is still commonly observed after AI-guided pulmonary vein isolation (PVI). The present study aimed to investigate the impact of local left atrial wall thickness on the incidence of acute PV reconnection after AI-guided atrial fibrillation (AF) ablation. METHODS AND RESULTS: Seventy patients (63% paroxysmal AF, 67% male, mean age 63 ± 8 years) who underwent preprocedural CT imaging and AI-guided AF ablation were studied. Occurrence of acute PV reconnection after initial PVI was assessed after a 30-minute waiting period. Ablation procedures were retrospectively analyzed and each ablation circle was subdivided into 8 segments. Minimum AI, force-time integral, contact force, ablation duration, power, impedance drop and maximum interlesion distance were determined for each segment. PV antrum wall thickness was assessed for each segment on reconstructed CT images based on patient-specific thresholds in Hounsfield Units. Acute reconnection occurred in 27/1120 segments (2%, 15 anterior/roof, 12 posterior/inferior) in 19/140 ablation circles (14%). Reconnected segments were characterized by a greater local atrial wall thickness, both in anterior/roof (1.87 ± 0.42 vs. 1.54 ± 0.42 mm; p < 0.01) and posterior/inferior (1.43 ± 0.20 vs. 1.16 ± 0.22 mm; p < 0.01) segments. Minimum AI, force-time integral, contact force, ablation duration, power, impedance drop and maximum interlesion distance were not associated with acute reconnection. CONCLUSIONS: Local atrial wall thickness is associated with acute pulmonary vein reconnection after AI-guided PVI. Individualized AI targets based on local wall thickness may be of use to create transmural ablation lesions and prevent PV reconnection after PVI.

16.
J Cardiovasc Electrophysiol ; 31(7): 1616-1627, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32406138

RESUMO

BACKGROUND: During pulmonary vein isolation (PVI), nonisolation after initial encircling of the pulmonary veins (PVs) may be due to gaps in the initial ablation line, or alternatively, earliest PV activation may occur on the intervenous carina and ablation within the wide-area circumferential ablation (WACA) circle is needed to eliminate residual conduction. This study investigated prognostic implications and predictors of gap-related persistent conduction (gap-RPC) and carina-related persistent conduction (carina-RPC) during PVI. METHODS AND RESULTS: Two hundred fourteen atrial fibrillation (AF) patients (57% paroxysmal, 61% male, mean age 62 ± 9 years) undergoing first contact force-guided radiofrequency PVI were studied. Preprocedural cardiac computed tomography imaging was used to assess left atrial and PV anatomy. PVI was assessed directly after initial WACA circle creation, after a minimum waiting period of 30 minutes, and after adenosine infusion. Persistent conduction was targeted for additional ablation and classified as gap-RPC or carina-RPC, depending on the earliest activation site. The 1-year AF recurrence rate was higher in patients with gap-RPC (47%) compared to patients without gap-RPC (28%; P = .003). No significant difference in 1-year recurrence rate was found between patients with carina-RPC (37%) and patients without carina-RPC (31%; P = .379). Multivariate analyses identified paroxysmal AF and WACA circumference as independent predictors of gap-RPC, whereas carina width and WACA circumference correlated with carina-RPC. CONCLUSIONS: Gap-RPC is associated with increased AF recurrence risk after PVI, whereas carina-RPC does not predict AF recurrence. Moreover, gap-RPC and carina-RPC have different correlates and may thus have different underlying mechanisms.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
17.
Int J Cardiol ; 304: 69-74, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32005449

RESUMO

BACKGROUND: Left atrial (LA) sphericity has been proposed as a more sensitive marker of atrial fibrillation (AF)-associated atrial remodeling compared to traditional markers such as LA size. However, mechanisms that underlie changes in LA sphericity are not fully understood and studies investigating the predictive value of LA sphericity for AF ablation outcome have yielded conflicting results. The present study aimed to assess correlates of LA sphericity and to compare LA sphericity in subjects with and without AF. METHODS: Measures of LA size (LA diameter, LA volume, LA volume index), LA sphericity and thoracic anteroposterior diameter (APd) at the level of the LA were determined using computed tomography (CT) imaging data in 293 AF patients (62% paroxysmal AF) and 110 controls. RESULTS: LA diameter (40.1 ± 6.8 mm vs. 35.2 ± 5.1 mm; p < 0.001), LA volume (116.0 ± 33.0 ml vs. 80.3 ± 22.6 ml; p < 0.001) and LA volume index (56.1 ± 15.3 ml/m2 vs. 41.6 ± 11.1 ml/m2; p < 0.001) were significantly larger in AF patients compared to controls, also after adjustment for covariates. LA sphericity did not differ between AF patients and controls (83.7 ± 2.9 vs. 83.9 ± 2.4; p = 0.642). Multivariable linear regression analysis demonstrated that LA diameter, LA volume, female sex, body length and thoracic APd were independently associated with LA sphericity. CONCLUSIONS: The present study suggests that thoracic constraints rather than the presence of AF determine LA sphericity, implying LA sphericity to be unsuitable as a marker of AF-related atrial remodeling.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Resultado do Tratamento
19.
Circ Cardiovasc Interv ; 12(4): e007641, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30929508

RESUMO

BACKGROUND: Transradial intervention (TRI) may impair digital perfusion with hand dysfunction as a result. However, the effect of TRI on digital perfusion has never been investigated, including the influence of variations of the collateral arterial network and the effect on hand dysfunction. METHODS AND RESULTS: We investigated the effect of TRI on digital perfusion by laser Doppler perfusion imaging. Laser Doppler perfusion imaging was performed at baseline, during radial access, TR band application, and at discharge. We compared tissue perfusion of the homolateral thumb (access site) with the contralateral thumb (comparator) during radial access as primary outcome. The hand circulation was assessed with angiography. Upper extremity function was evaluated with the validated QuickDASH questionnaire at baseline and follow-up. A significant reduction of tissue perfusion was observed during radial access and TR band application in the homolateral thumb (-32%, -32%, respectively) and contralateral thumb (-34%, -21%, respectively). We detected no perfusion difference between the homolateral and contralateral thumb during radial access (217; interquartile range, 112-364 versus 209; interquartile range, 99-369 arbitrary flux units; P=0.59). Reduced perfusion of the thumb during radial access was not associated with incompleteness of the superficial palmar arch ( P=0.13). Digital perfusion improved at discharge, though it remained below baseline levels (homolateral -11% and contralateral -14%). Hand dysfunction at 18 months was not associated with TRI-induced perfusion reduction ( P=0.54). CONCLUSIONS: TRI is safe. Digital perfusion is reduced in both hands during radial access and TR band application but is not associated with future loss of hand function and variations of the arterial hand supply.


Assuntos
Cateterismo Periférico/efeitos adversos , Dedos/irrigação sanguínea , Isquemia/etiologia , Artéria Radial/fisiopatologia , Idoso , Velocidade do Fluxo Sanguíneo , Circulação Colateral , Avaliação da Deficiência , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão , Estudos Prospectivos , Punções , Artéria Radial/diagnóstico por imagem , Recuperação de Função Fisiológica , Fluxo Sanguíneo Regional , Inquéritos e Questionários , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS