Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Adv Sci (Weinh) ; 7(23): 2002563, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33304764

RESUMO

The glorious charge transfer efficiency of photoanode is an important factor for efficient photoelectrochemical (PEC) water oxidation. However, it is often limited by slow kinetics of oxygen evolution reaction. Herein, a dual transition metal-based metal-organic frameworks (MOF) cocatalyst, Fe@Ni-MOF, is introduced into a titanium-doped hematite (Fe2O3:Ti) photoanode. The combination of Ni and Fe can optimize the filling of 3d orbitals. Moreover, the introduction of Fe donates electrons to Ni in the MOF structure, thus, suppressing the irreversible (long-life-time) oxidation of Ni2+ into Ni3+. The resulting Fe@Ni-MOF/Fe2O3:Ti photoanode exhibits ∼threefold enhancement in the photocurrent density at 1.23 V versus the reversible hydrogen electrode. Kinetic analysis of the PEC water oxidation processes indicates that this performance improvement is primarily due to modulating the charge transfer efficiency of hematite photoanode. Further results show that a single transition metal-based MOF cocatalyst, Ni-MOF, exhibits slow charge transfer in spite of a reduction in surface charge recombination, resulting in a smaller charge transfer efficiency. These findings provide new insights for the development of photoelectrodes decorated with MOFs.

2.
World J Pediatr Congenit Heart Surg ; 11(3): 338-342, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32294021

RESUMO

Iatrogenic aortopulmonary communications (IAPCs) are an uncommon but important complication after percutaneous intervention in postoperative patients. Iatrogenic aortopulmonary communications typically occur after balloon angioplasty or other interventions of the pulmonary outflow tract in certain anatomic configurations in which there is a denuded tissue plane between the pulmonary artery and aorta. They can present with signs and symptoms ranging from subtle clues which are difficult to recognize to near immediate hemodynamic instability. Once recognized, these lesions can become management dilemmas, and intraprocedural interventions can be complicated by complex anatomy and inadequate visualization by standard imaging techniques. We report cases where intracardiac echocardiography (ICE) was integral in the evaluation and management of IAPC as complications of prior transcatheter interventions. We found using ICE safely and effectively identified IAPCs and reduced the technical difficulty of intervention after IAPC discovery.


Assuntos
Angioplastia Coronária com Balão , Aorta/cirurgia , Cateterismo Cardíaco , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/cirurgia , Adolescente , Aorta/diagnóstico por imagem , Comunicação , Ecocardiografia , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Doença Iatrogênica , Masculino , Pacientes , Período Pós-Operatório , Artéria Pulmonar/diagnóstico por imagem , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia
3.
Chem Soc Rev ; 49(6): 1887-1931, 2020 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-32101197

RESUMO

This review focuses on the discussion of the latest progress and remaining challenges in selected metal-free photocatalysts for hydrogen production. The scope of this review is limited to the metal-free elemental photocatalysts (i.e. B, C, P, S, Si, Se etc.), binary photocatalysts (i.e. BC3, B4C, CxNy, h-BN etc.) and their heterojunction, ternary photocatalysts (i.e. BCN) and their heterojunction, and different types of organic photocatalysts (i.e. linear, covalent organic frameworks, microporous polymer, covalent triazine frameworks etc.) and their heterostructures. Following a succinct depiction of the latest progress in hydrogen evolution on these photocatalysts, discussion has been extended to the potential strategies that are deemed necessary to attain high quantum efficiency and high solar-to-hydrogen (STH) conversion efficiency. Issues with reproducibility and the disputes in reporting the hydrogen evolution rate have been also discussed with recommendations to overcome them. A few key factors are highlighted that may facilitate the scalability of the photocatalyst from microscale to macroscale production in meeting the targeted 10% STH. This review is concluded with additional perspectives regarding future research in fundamental materials aspects of high efficiency photocatalysts followed by six open questions that may need to be resolved by forming a global hydrogen taskforce in order to translate bench-top research into large-scale production of hydrogen.

4.
F1000Res ; 72018.
Artigo em Inglês | MEDLINE | ID: mdl-29770200

RESUMO

Vascular occlusions continue to be a significant cause of morbidity and mortality. The management of vascular occlusions in patients is complex, requiring specialized expertise in the cardiac catheterization laboratory and from other disciplines. Knowledge of currently available tools at the operator's disposal is important to optimize the success of these procedures. In this review, we discuss some of the recent advances in recanalization procedures of vascular occlusions and thrombotic lesions in the cardiac catheterization laboratory.

5.
Am J Cardiol ; 121(12): 1617-1623, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29681368

RESUMO

Outcome data for neonates with critical pulmonary stenosis (PS) is limited. We aimed to review the outcomes after balloon pulmonary valvuloplasty (BPV) for neonates with critical PS at our institution. All neonates with critical PS who underwent BPV from 1990 to 2017 were included. A total of 44 neonates underwent BPV for critical PS. Nonright ventricular dependent coronary artery fistulas was seen in 6/44 (13.6%) patients. Tricuspid valve z-scores were -1.9 (interquartile range [IQR] -3.04, -0.48) in those with coronary artery fistulas as compared with -0.27 (IQR -0.5, 0.8) in those without (p = 0.03). Fifteen of forty-four subjects (34.1%) patients underwent reintervention with 10 patients (22.7%) requiring an alternate source of pulmonary blood flow (3 patients subsequently underwent right ventricular overhaul, 2 underwent Glenn operations, and 1 underwent repeat BPV). Five patients underwent reintervention for right ventricular outflow tract obstruction. Pulmonary valve annulus z-score was significantly smaller in those who needed reintervention -2.4 (IQR -2.9 to -0.95) versus -0.59 (IQR -1.3, -0.15); p = 0.02. At a median follow-up of 8.2 (IQR 3.4 to 13.1) years, moderate or severe pulmonary regurgitation was seen in 22/42 (53.7 %) patients with biventricular circulation, 3 requiring pulmonary valve repair/replacement. In conclusion, coronary artery fistulas occur in a significant number of patients with critical pulmonary stenosis, occurring more frequently in patients with small tricuspid valves. Reintervention is required for 1/3 of patients. Patients with small pulmonary valve annuli are more likely to undergo reintervention for right ventricular outflow tract obstruction. Significant pulmonary regurgitation is common and may require eventual pulmonary valve replacement.


Assuntos
Valvuloplastia com Balão , Doença da Artéria Coronariana/epidemiologia , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Fístula Vascular/epidemiologia , Comorbidade , Angiografia Coronária , Doença da Artéria Coronariana/congênito , Permeabilidade do Canal Arterial , Feminino , Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração , Humanos , Recém-Nascido , Masculino , Complicações Pós-Operatórias/epidemiologia , Insuficiência da Valva Pulmonar/epidemiologia , Estenose da Valva Pulmonar/congênito , Estenose da Valva Pulmonar/epidemiologia , Reoperação , Fístula Vascular/congênito
6.
ACS Nano ; 11(10): 10347-10356, 2017 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-28898580

RESUMO

Through a gelation-solvothermal method without heteroadditives, Cu-Sn-S composites self-assemble to form nanotubes, sub-nanotubes, and nanoparticles. The nanotubes with a Cu3-4SnS4 core and Cu2SnS3 shell can tolerate long cycles of expansion/contraction upon lithiation/delithiation, retaining a charge capacity of 774 mAh g-1 after 200 cycles with a high initial Coulombic efficiency of 82.5%. The importance of the Cu component for mitigation of the volume expansion and structural evolution upon lithiation is informed by density functional theory calculations. The self-generated template and calculated results can inspire the design of analogous Cu-M-S (M = metal) nanotubes for lithium batteries or other energy storage systems.

7.
Catheter Cardiovasc Interv ; 84(5): 779-84, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24890705

RESUMO

Pediatric and Congenital Interventional Cardiology is the practice of catheter-based techniques that improve cardiac physiology and circulation through the treatment of heart disease in children and adults with congenital or acquired heart defects. Over the last decade, and since last published training guidelines for pediatric cardiac catheterization and interventional cardiology were published in 2005 [1] the field of Pediatric and Congenital Cardiac Catheterization has evolved into a predominantly interventional discipline. As there is no sub-specialty certification for interventional cardiac catheterization in pediatrics, the Congenital Heart Disease Committee of the Society of Cardiovascular Angiography and Interventions has put together this consensus statement for advanced training in pediatric and congenital interventional cardiac catheterization. The statement puts forth recommendations for program infrastructure in terms of teaching, personnel, equipment, facilities, conferences, patient volume and trainee assessment. This is meant to set a standard for training programs as well as giving applicants a basis on which to judge and compare programs.


Assuntos
Angioplastia Coronária com Balão/educação , Cateterismo Cardíaco , Competência Clínica , Educação Médica Continuada/organização & administração , Cardiopatias Congênitas/terapia , Criança , Pré-Escolar , Consenso , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente , Recém-Nascido , Pediatria/educação , Guias de Prática Clínica como Assunto , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Sociedades Médicas
8.
Hum Gene Ther ; 24(8): 761-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23902403

RESUMO

Helper-dependent adenoviral vectors (HDAd) have been shown to mediate a considerably longer duration of transgene expression than first-generation adenoviral vectors. We have previously shown that transgene expression from HDAd-transduced hepatocytes can persist at high levels for up to 2.6 years in nonhuman primates following a single-vector administration. Because duration of transgene expression and long-term toxicity are critical for risk:benefit assessment, we have continued to monitor these animals. We report here that transgene expression has persisted for the entire observation period of up to 7 years for all animals without long-term adverse effects. However, in all cases, transgene expression level slowly declined over time to less than 10% of peak values by the end of the observation period but remained 2.3-111-fold above baseline values. These results will provide important information for a more informed risk:benefit assessment before clinical application of HDAd.


Assuntos
Adenoviridae/genética , Expressão Gênica , Vetores Genéticos/genética , Vírus Auxiliares/genética , Fígado/efeitos dos fármacos , Transdução Genética , Transgenes/genética , Animais , Papio , Tempo
10.
Mol Ther ; 20(10): 1863-70, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22828499

RESUMO

Hemophilia B is an excellent candidate for gene therapy because low levels of factor IX (FIX) (≥1%) result in clinically significant improvement of the bleeding diathesis. Helper-dependent adenoviral (HDAd) vectors can mediate long-term transgene expression without chronic toxicity. To determine the potential for HDAd-mediated liver-directed hemophilia B gene therapy, we administered an HDAd expressing hFIX into rhesus macaques through a novel and minimally invasive balloon occlusion catheter-based method that permits preferential, high-efficiency hepatocyte transduction with low, subtoxic vector doses. Animals given 1 × 10(12) and 1 × 10(11) virus particle (vp)/kg achieved therapeutic hFIX levels for the entire observation period (up to 1,029 days). At 3 × 10(10) and 1 × 10(10) vp/kg, only subtherapeutic hFIX levels were achieved which were not sustained long-term. Balloon occlusion administration of HDAd was well tolerated with negligible toxicity. Five of six animals developed inhibitors to hFIX. These results provide important information in assessing the clinical utility of HDAd for hemophilia B gene therapy.


Assuntos
Adenoviridae/genética , Cateterismo/métodos , Fator IX/genética , Vetores Genéticos , Hemofilia B/terapia , Macaca mulatta/genética , Adenoviridae/metabolismo , Animais , Modelos Animais de Doenças , Fator IX/metabolismo , Regulação da Expressão Gênica , Terapia Genética , Vírus Auxiliares/genética , Vírus Auxiliares/metabolismo , Hemofilia B/genética , Fígado/citologia , Fígado/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Transdução Genética/métodos , Transgenes/genética
11.
Catheter Cardiovasc Interv ; 80(7): 1190-9, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22511546

RESUMO

OBJECTIVES: We studied outcomes of neonatal aortic valvuloplasty to determine the risk factors for poor outcomes. BACKGROUND: Balloon aortic valvuloplasty (BAV) is the primary therapy for neonates with severe aortic stenosis (AS). Limited data are available on the mid-term and long-term outcomes in this population, and reported risk factors for poor outcomes vary among studies. METHODS: We reviewed all cases of BAV in neonates in our institution between 1998 and 2009. We reviewed patient characteristics, preintervention echocardiographic, and procedural details. We tracked repeat BAV, aortic valve replacement (AVR), and death/transplant. Kaplan-Meier and Cox regression analyses were performed. Changes in dimensions of left heart structures post-BAV were also studied. RESULTS: Forty-eight neonates were included-of these, 30 (62%) had critical AS. There was one procedural death. The remaining 47 neonates were followed for 4.8 ± 4.4 years. Repeat BAV was performed in 19 (40%) neonates; AVR was performed in 9 (19%), and death/transplant occurred in 4 (8%) neonates. Multivariate analysis revealed that lower LV shortening fraction pre-BAV, higher pre-BAV and final valve gradient, and need for inotropes were associated with poor long-term outcomes. LV diastolic and systolic dimensions normalized over time, and left heart structures improved in size early and late after BAV. CONCLUSIONS: Neonatal BAV is associated with low mortality. Lower LV shortening fraction pre-BAV is associated with risk of future interventions, while repeat valvuloplasty is safe and effective for recurrent AS. There is significant improvement in dimensions of the LV and aortic valve annulus following BAV.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Valvuloplastia com Balão/efeitos adversos , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia Doppler , Feminino , Implante de Prótese de Valva Cardíaca , Mortalidade Hospitalar , Humanos , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Texas , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
12.
Am J Cardiol ; 108(7): 1024-8, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21791328

RESUMO

Balloon aortic valvuloplasty (BAV) is the primary therapy for congenital aortic stenosis (AS). Few reports describe long-term outcomes. In this study, a retrospective single-institution review was performed of patients who underwent BAV for congenital AS. The following end points were evaluated: moderate or severe aortic insufficiency (AI) by echocardiography, aortic valve replacement, repeat BAV, surgical aortic valvotomy, and transplantation or death. From 1985 to 2009, 272 patients who underwent BAV at ages 1 day to 30.5 years were followed for 5.8 ± 6.7 years. Transplantation or death occurred in 24 patients (9%) and was associated with depressed baseline left ventricular shortening fraction (LVSF) (p = 0.04). Aortic valve replacement occurred in 42 patients (15%) at a median of 3.5 years (interquartile range 75 days to 5.9 years) after BAV and was associated with post-BAV gradient ≥25 mm Hg (p = 0.02), the presence of post-BAV AI (p = 0.03), and below-average baseline LVSF (p = 0.04). AI was found in 83 patients (31%) at a median of 4.8 years (interquartile range 1.4 to 8.7) and was inversely related to post-BAV gradient ≥25 mm Hg (p <0.04). AI was associated with depressed baseline LVSF (p = 0.02). Repeat valvuloplasty (balloon or surgical) occurred in 37 patients (15%) at a median of 0.51 years (interquartile range 0.10 to 5.15) and was associated with neonatal BAV (p <0.01), post-BAV gradient ≥25 mm Hg (p = 0.03), and depressed baseline LVSF (p = 0.05). In conclusion, BAV confers long-term benefits to most patients with congenital AS. Neonates, patients with post-BAV gradients ≥25 mm Hg, and patients with lower baseline LVSF experienced worse outcomes.


Assuntos
Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/terapia , Cateterismo/métodos , Adolescente , Adulto , Valva Aórtica , Estenose da Valva Aórtica/mortalidade , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Texas/epidemiologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
14.
Catheter Cardiovasc Interv ; 77(3): 390-4, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-20549686

RESUMO

BACKGROUND: Pulmonary artery (PA) stents are utilized to treat branch pulmonary stenosis (BPS). Often patients with PA stents undergo subsequent cardiac surgery for other indications, and the stents can be manipulated during the procedure. OBJECTIVE: The purpose of this study was to evaluate the outcome of branch PA stenoses following surgical manipulation of previously implanted PA stents and to determine factors associated with future reintervention. METHODS: Catheterization data, operative reports, and clinical summaries were reviewed on patients with PA stents placed between September 1989 and December 2006 undergoing subsequent cardiac surgery. Surgical manipulation was recorded as removed, trimmed, or longitudinally transected, and patched. Those that were not manipulated were defined as untouched. RESULTS: 459 patients had branch PA stents placed. About 54 patients, with 70 stents in branch PA's. subsequently had further cardiac surgery. The median age of stent placement was 7.5 (0.5-32.4) years with a median age of surgery of 12.7 (5.1-39.6) years. Surgical manipulation was performed in 23 (33%) PA's and 47 (66%) stents were untouched. Stent removal occurred in 11 (16%), with transecting longitudinally and patching in 5 (7%), and trimming in 7 (10%). Comparing the surgical manipulation and the untouched groups, there was no difference in median age of stent placement [7.2 (0.5-30.2) versus 7.6 (1.8-32.4) years, p=0.40], wt [21.0 (5.3-86.5) versus 24.7 (9.0-96.0) kg, p=0.42], or residual catheterization gradient across the stent [3 (0-59) versus 4 (0-50) mmHg, p=0.81]. Catheter reintervention (stent n=6 or balloon dilation n=14) on the previously stented PAs was similar between the surgically manipulated (median 7.5 years) and untouched groups (median 11.5 years) (p=0.31). In multivariate analysis, the factors associated with future catheter reintervention were having the stent transected longitudinally and patched (p=0.003) and a lower weight (p=0.006) at the time of stent placement. CONCLUSIONS: Surgical stent manipulation is often performed in patients who have PA stents. Surgical manipulation does not alter the need for future reintervention and catheter re-intervention may be more likely when the stents are transected longitudinally and patched.


Assuntos
Angioplastia/instrumentação , Arteriopatias Oclusivas/terapia , Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar/cirurgia , Stents , Adolescente , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Constrição Patológica , Remoção de Dispositivo , Feminino , Humanos , Lactente , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Desenho de Prótese , Artéria Pulmonar/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
17.
Catheter Cardiovasc Interv ; 75(5): 757-64, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20146310

RESUMO

OBJECTIVES: Determine the long-term outcomes of branch pulmonary artery (PA) stents. BACKGROUND: PA stents in congenital heart disease effectively relieve stenoses in the short-term. Published long-term data are limited. METHODS: Patients enrolled in an FDA IDE protocol from 1989-92 were included. Clinical follow-up and catheterization data were evaluated. Patients were included if >5 year follow-up data was available or if mortality occurred following the initial procedure. RESULTS: There were five deaths: four due to progression of their underlying heart disease, and one from a complication during a follow-up catheterization. Clinical data for 43 surviving patients demonstrated 39 patients (91%) are in NYHA class I or II. Seven patients underwent surgical intervention during the follow-up period (five RV-PA conduit, two Fontan revisions), but none addressed PA stenosis. Final repeat catheterizations were performed in 36 patients (55 stents) 7.2 +/- 4.3 years post stent insertion with 1.2 +/- 0.9 further procedures with stent dilations. In this subgroup, the minimum vessel diameter increased from 4.7 +/- 1.8 to 13.4 +/- 2.4 mm (P < 0.001), and the pressure gradient improved from 41 +/- 25 to 9 +/- 11 mm Hg (P < 0.001). Higher initial gradient and smaller balloons were associated with a final stent diameter of <14 mm (P = 0.030 and 0.046). Jailed vessels occurred in 49% of stents with abnormal angiographic flow in 18/55. Six repeat catheterizations resulted in complications, including the one procedural death. CONCLUSION: Stents implants for PA stenoses provide effective improvement in vessel caliber in the long-term. Although repeat interventions are necessary, this procedure reduces RV pressure and provides an important alternative to surgery for residual PA obstruction.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/terapia , Cardiopatias Congênitas/terapia , Artéria Pulmonar , Stents , Adolescente , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/mortalidade , Arteriopatias Oclusivas/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Criança , Pré-Escolar , Constrição Patológica , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/crescimento & desenvolvimento , Artéria Pulmonar/fisiopatologia , Radiografia , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
18.
JACC Cardiovasc Interv ; 3(12): 1295-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21232725

RESUMO

OBJECTIVES: We sought to analyze the outcomes of transcatheter patent ductus arteriosus (PDA) occlusion using a variety of devices in infants weighing ≤6 kg. BACKGROUND: Indications for transcatheter closure of a PDA in infancy include congestive heart failure and/or failure to thrive. Devices available for small infants may be problematic for various reasons, including sheath size, stiffness of delivery system, and anchoring and retrievability characteristics of the device. The Amplatzer Ductal Occluder is approved by U.S. Food and Drug Administration for children weighing >6 kg and older than 6 months of age. METHODS: We performed a multicenter, retrospective analysis of children weighing ≤6 kg in whom transcatheter PDA occlusion was attempted between January 1995 and November 2005 at Texas Children's Hospital and January 2001 to November 2005 at Children's Hospital of San Diego. RESULTS: A total of 62 patients underwent attempted closure. The mean age at catheterization was 4.7 ± 2.8 months with a mean weight at catheterization of 4.6 ± 0.9 kg. Successful device placement was achieved in 58 of 62 patients (94%). Among those receiving a device, complete occlusion was noted in all 58 patients at either catheterization or last available follow-up. CONCLUSIONS: Percutaneous closure of PDA should be considered even in infants ≤6 kg.


Assuntos
Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia Doppler em Cores , Estados Unidos , United States Food and Drug Administration
19.
Catheter Cardiovasc Interv ; 73(4): 557-63, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19235243

RESUMO

BACKGROUND: Balloon angioplasty of bifurcating pulmonary artery (PA) stenoses is often inadequate, and stent treatment often requires simultaneous implantation of two stents. This study evaluates initial results and long-term follow up of transcatheter stent placement in bifurcating PAs. METHODS: This is a retrospective review of patients (pts) who had bifurcating PA stents placed in main and lobar branches from 1993 to 2007. RESULTS: Forty-nine pts had bifurcating PA stents placed at a median age of 10.9 years (range 1-43 years). The mean minimum vessel diameter increased from 5.7 +/- 2.5 mm to 11.0 +/- 3.6 mm (P < 0.001), the mean gradient across the stenoses decreased from 37.0 +/- 26.9 to 9.2 +/- 13 mm Hg (P < 0.001), whereas the mean RV:FA ratio decreased from 0.76 +/- 0.29 to 0.53 +/- 0.24 (P < 0.001). There was one death due to severe pulmonary hemorrhage. F/U data were available in 38 pts (mean duration 6.3 +/- 4.1 years, range 1.2-13.1 years). Thirty pts underwent repeat catheterizations (mean 2.3 +/- 2.2 years poststent), with 26 requiring further interventions: Fifteen had balloon angioplasty alone and 11 had additional stents placed. There were no complications at f/u catheterization. Six pts underwent further palliative surgeries, although none for repair of branch PA stenoses. CONCLUSIONS: Simultaneous transcatheter placement of bifurcating PA stents provides immediate gradient relief of bifurcating stenoses in the proximal or lobar branch PAs and reduces RV systolic pressure. Further interventions can be safely performed in future procedures, and the presence of stents does not complicate future surgeries.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/terapia , Artéria Pulmonar , Stents , Adolescente , Adulto , Angioplastia com Balão/efeitos adversos , Arteriopatias Oclusivas/patologia , Arteriopatias Oclusivas/fisiopatologia , Pressão Sanguínea , Criança , Pré-Escolar , Constrição Patológica , Feminino , Humanos , Lactente , Masculino , Artéria Pulmonar/patologia , Artéria Pulmonar/fisiopatologia , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Direita , Pressão Ventricular , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...