Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
eNeurologicalSci ; 10: 31-36, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29736426

RESUMO

INTRODUCTION: The purpose of this study was to analyze the results of patients with ruptured aneurysms who were treated with a specific microstent in the acute phase of subarachnoid hemorrhage. METHODS: Data from patients with acutely-ruptured intracranial aneurysm treated with the Neuroform stent in the period between 2003 and 2016 were retrospectively assessed, addressing aneurysm occlusion and clinical outcome with a focus on periprocedural complications. RESULTS: Twenty-nine consecutive patients with ruptured intracranial aneurysms were included in the analysis. Periprocedural hemorrhagic complications were stated in six patients, leading to death in four. Thromboembolic complications were observed in seven patients, among whom only one affected the clinical outcome with death due to basilar thrombosis. Immediate complete occlusion and occlusion with residual neck was achieved in 79.3% of cases. CONCLUSION: Stent-assisted coiling of acutely-ruptured aneurysms achieves good immediate aneurysm occlusion. Rates of intra- and periprocedural adverse events observed in this series were significant, but did not translate to corresponding morbidity and mortality in all cases. The retrospective analysis did not allow assessing the overall risks of endovascular therapy with stent use in ruptured and complex aneurysm when compared to the overall risks with other alternative options.

2.
PLoS One ; 11(11): e0167072, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27880819

RESUMO

BACKGROUND: Several studies have found that standard risk scores inaccurately reflect risk in TAVI cohorts. The assessment of mortality risk upon post-interventional ICU admission is important to optimizing clinical management. This study sought to determine outcomes and factors affecting mortality in patients admitted to the intensive care unit (ICU) after transcatheter aortic valve implantation (TAVI), and to analyze and compare the predictive values of SAPS II and EuroSCORE. METHODS AND FINDINGS: 214 consecutive patients treated with transfemoral TAVI (2006-2012) admitted to the ICU in an academic tertiary-care university hospital, were included in this retrospective data analysis. The overall 30-day mortality rate was 7%. Non-survivors at 30-days and survivors showed differences in the rates of catecholamine therapy upon ICU admission (93 vs. 29%; p<0.001), stroke (20 vs. 1%;p<0.001), sepsis (27 vs. 2%;p<0.001), kidney injury (83 vs. 56%; log-rank p<0.001), catecholamine therapy (88 vs. 61%;log-rank p<0.001) and vascular complications (60 vs. 17%; p<0.001). Mean SAPS II score and predicted mortality were higher in non-survivors (38.1±7.0 vs. 29.9±6.2;p<0.001 and 23.1±11.7 vs. 10.5±8.2;p<0.001, retrospectively), whereas the logistic EuroSCORE could not discriminate between the groups (p = 0.555). Among the biochemical parameters, the maximum values of creatinine, procalcitonin, and troponin I during the first 48 h after ICU admission were significantly higher in non-survivors. Multivariate analysis of baseline characteristics and complications associated with two-year mortality showed no significant results. CONCLUSIONS: The SAPS II is a good tool for estimating ICU mortality immediately after performing the TAVI procedure and provides valuable information for other known predictors of mortality.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Sepse , Acidente Vascular Cerebral , Injúria Renal Aguda/sangue , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Calcitonina/sangue , Creatinina/sangue , Cuidados Críticos , Intervalo Livre de Doença , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Unidades de Terapia Intensiva , Masculino , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Medição de Risco , Sepse/sangue , Sepse/etiologia , Sepse/mortalidade , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Taxa de Sobrevida , Troponina I/sangue
3.
Eur J Transl Myol ; 26(4): 5962, 2016 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28078065

RESUMO

Neuromuscular junction disorders affect the pre- or postsynaptic nerve to muscle transmission due to autoimmune antibodies. Members of the group like myasthenia gravis and Lambert-Eaton syndrome have pathophysiologically distinct characteristics. However, in practice, distinction may be difficult. We present a series of three patients with a myasthenic syndrome, dropped-head syndrome, bulbar and respiratory muscle weakness and positive testing for anti-N-type voltage-gated calcium channel antibodies. In two cases anti-acetylcholin receptor antibodies were elevated, anti-P/Q-type voltage-gated calcium channel antibodies were negative. All patients initially responded to pyridostigmine with a non-response in the course of the disease. While one patient recovered well after treatment with intravenous immunoglobulins, 3,4-diaminopyridine, steroids and later on immunosuppression with mycophenolate mofetil, a second died after restriction of treatment due to unfavorable cancer diagnosis, the third patient declined treatment. Although new antibodies causing neuromuscular disorders were discovered, clinical distinction has not yet been made. Our patients showed features of pre- and postsynaptic myasthenic syndrome as well as severe dropped-head syndrome and bulbar and axial muscle weakness, but only anti-N-type voltage-gated calcium channel antibodies were positive. When administered, one patient benefited from 3,4-diaminopyridine. We suggest that this overlap-syndrome should be considered especially in patients with assumed seronegative myasthenia gravis and lack of improvement under standard therapy.

4.
Ann Thorac Surg ; 98(1): 53-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24841546

RESUMO

BACKGROUND: The risk of clinically apparent, periprocedural stroke after thoracic endovascular aortic repair (TEVAR) due to dislodgement and embolization of aortic debris from intravascular manipulation of guidewires, catheters, and large-bore delivery systems ranges between 2% and 6% and has been associated with increased postoperative mortality. The rate of clinically silent cerebral ischemia is yet unknown, but may be even higher. METHODS: Nineteen patients (13 male, 6 female) who underwent TEVAR were included into this descriptive study. Periprocedural apparent and silent cerebral ischemia was assessed by daily clinical neurologic assessment and serial cerebral diffusion-weighted magnetic resonance imaging (DW-MRI) at baseline and 5 days (median, interquartile range: 3.5) after the procedure. RESULTS: The TEVAR was successful in all patients without immediate clinically apparent neurologic deficits. Postinterventional cerebral DW-MRI detected a total of 29 new foci of restricted diffusion in 12 of 19 TEVAR patients (63%). Lesions were usually multiple (1 to 6 lesions per patient) and ranged in size between 15 mm3 and 300 mm3; 16 lesions were found in the left hemisphere, 13 lesions in the right hemisphere. Overstenting of the left subclavian artery was performed in 8 cases, but was not associated with lateralization of lesions. There were no additional apparent neurologic events during the in-hospital period. CONCLUSIONS: Thoracic endovascular aortic repair resulted in a high incidence of new foci of restricted diffusion on cerebral DW-MRI in a pattern suggestive of periprocedural embolization. Although multiple lesions per patients were found, these lesions were not associated with apparent neurologic deficits during the in-hospital period. Further developments in TEVAR should be directed toward reducing the risk of periprocedural cerebral embolization.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Isquemia Encefálica/etiologia , Imagem de Difusão por Ressonância Magnética/métodos , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler Transcraniana/métodos , Idoso , Aneurisma da Aorta Torácica/diagnóstico , Prótese Vascular/efeitos adversos , Isquemia Encefálica/diagnóstico , Feminino , Seguimentos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia Doppler Dupla/métodos
6.
Neuroradiology ; 55(4): 459-65, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23358878

RESUMO

INTRODUCTION: Our purpose was to analyze the long-term evolution of wide neck cerebral aneurysms treated with stent assistance. METHODS: Data of consecutive patients treated with the Neuroform stent over 9 years were retrospectively analyzed with emphasis on periprocedural complications, aneurysm occlusion grade evolution, and in-stent stenosis rates. RESULTS: Altogether, 113 patients with 117 unruptured and ruptured aneurysms were subject of analysis. Mean aneurysm size was 9.4 mm, and mean neck size was 4.7 mm. Procedural thromboembolic and hemorrhagic complications affected eight (6.8%) and four cases (3.4%), respectively. Immediate complete occlusion and occlusion with residual neck was achieved in 85% of cases, which at the first follow-up of 6 months, changed to 77 and 76 % at 36 months. Aneurysms ≥10 mm showed a higher tendency of recurrence. During the overall follow-up time ranging from 1 to 9 years, an in-stent stenosis of ≥50 % was observed only in three cases, all of them being asymptomatic. CONCLUSIONS: Stent-assisted coiling of wide neck aneurysms provided stable occlusion over the long-term follow-up, with very low and silent in-stent stenosis rates. Some incompletely occluded aneurysms showed a tendency of progressive occlusion; however, this was counterbalanced by the regrowth of others.


Assuntos
Prótese Vascular/estatística & dados numéricos , Oclusão de Enxerto Vascular/epidemiologia , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/cirurgia , Stents/estatística & dados numéricos , Comorbidade , Europa (Continente)/epidemiologia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Radiografia , Recidiva , Estudos Retrospectivos , Medição de Risco
7.
Circulation ; 126(10): 1245-55, 2012 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-22899774

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear. METHODS AND RESULTS: Eighty-three patients underwent transfemoral (Medtronic CoreValve [MCV(TF)], n=32; Edwards Sapien [ES(TF)], n=26) and transapical (ES(TA): n=25) TAVI. Serial transcranial Doppler examinations before, during, and 3 months after TAVI were used to identify high-intensity transient signals (HITS) as a surrogate for microembolization. Procedural HITS were detected in all patients, predominantly during manipulation of the calcified aortic valve while stent valves were being positioned and implanted. The balloon-expandable ES prosthesis caused significantly more HITS (mean [95% CI]) during positioning (ES(TF), 259.9 [184.8-334.9]; ES(TA), 206.1[162.5-249.7]; MCV(TF), 78.5 [25.3-131.6]; P<0.001) and the self-expandable MCV prosthesis during implantation (MCV(TF), 397.1 [302.1-492.2]; ES(TF), 88.2 [70.2-106.3]; ES(TA), 110.7 [82.0-139.3]; P<0.001). Overall, there were no significant differences between transfemoral and transapical TAVI or between the MCV and ES prostheses. No HITS were detected at baseline or 3-month follow-up. There was 1 major procedural stroke that resulted in death and 1 minor procedural stroke with full recovery at 3-month follow-up in the MCV group. CONCLUSIONS: Procedural HITS were detected by transcranial Doppler in all patients. Although no difference was observed between the transfemoral and the transapical approach with the balloon-expandable ES stent valve, transfemoral TAVI with the self-expandable MCV prosthesis resulted in the greatest number of HITS, predominantly during implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/epidemiologia , Complicações Intraoperatórias/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/epidemiologia , Calcinose/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Comorbidade , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Complicações Intraoperatórias/epidemiologia , Masculino , Placa Aterosclerótica/epidemiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA