1.
J Appl Clin Med Phys ; 24(5): e13910, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36650923

RESUMO

PURPOSE: The CyberKnife system is a specialized device for non-coplanar irradiation; however, it possesses the geometric restriction that the beam cannot be irradiated from under the treatment couch. Prone positioning is expected to reduce the dose to normal lung tissue in spinal stereotactic body radiotherapy (SBRT) owing to the efficiency of beam arrangement; however, respiratory motion occurs. Therefore, the Xsight spine prone tracking (XSPT) system is used to reduce the effects of respiratory motion. The purpose of this study was to evaluate the motion-tracking error of the spine in the prone position. MATERIALS AND METHODS: Data from all 25 patients who underwent spinal SBRT at our institution between April 2020 and February 2022 using CyberKnife (VSI, version 11.1.0) with the XSPT tracking system were retrospectively analyzed using log files. The tumor motion, correlation, and prediction errors for each patient were examined. Furthermore, to assess the potential relationships between the parameters, the relationships between the tumor-motion amplitudes and correlation or prediction errors were investigated using linear regression. RESULTS: The tumor-motion amplitudes in each direction were as follows: superior-inferior (SI), 0.51 ± 0.39 mm; left-right (LR), 0.37 ± 0.29 mm; and anterior-posterior (AP), 3.43 ± 1.63 mm. The overall mean correlation and prediction errors were 0.66 ± 0.48 mm and 0.06 ± 0.07 mm, respectively. The prediction errors were strongly correlated with the tumor-motion amplitudes, whereas the correlation errors were not. CONCLUSIONS: This study demonstrated that the correlation error of spinal SBRT in the prone position is sufficiently small to be independent of the tumor-motion amplitude. Furthermore, the prediction error is small, contributing only slightly to the tracking error. These findings will improve the understanding of how to compensate for respiratory-motion uncertainty in the prone position.


Assuntos
Neoplasias , Radiocirurgia , Humanos , Estudos Retrospectivos , Decúbito Ventral , Planejamento da Radioterapia Assistida por Computador , Movimento (Física)
2.
J Appl Clin Med Phys ; 23(6): e13596, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35377962

RESUMO

PURPOSE: Real-time tracking systems of moving respiratory targets such as CyberKnife, Radixact, or Vero4DRT are an advanced robotic radiotherapy device used to deliver stereotactic body radiotherapy (SBRT). The internal target volume (ITV) of lung tumors is assessed through a fiducial marker fusion using four-dimensional computed tomography (CT). It is important to minimize the ITV to protect normal lung tissue from exposure to radiation and the associated side effects post SBRT. However, the ITV may alter if there is a change in the position of the fiducial marker with respect to the tumor. This study investigated the relationship between fiducial marker position and the ITV in order to prevent radiation exposure of normal lung tissue, and correct target coverage. MATERIALS AND METHODS: This study retrospectively reviewed 230 lung cancer patients who received a fiducial marker for SBRT between April 2015 and September 2021. The distance of the fiducial marker to the gross tumor volume (GTV) in the expiratory (dex ) and inspiratory (din ) CT, and the ratio of the ITV/V(GTVex ), were investigated. RESULTS: Upon comparing each lobe, although there was no significant difference in the ddiff and the ITV/V(GTVex ) between all lobes for dex  < 10 mm, there was significant difference in the ddiff and the ITV/V(GTVex ) between the lower and upper lobes for dex ≥ 10 mm (p < 0.05). Moreover, there was significant difference in the ddiff and the ITV/V(GTVex ) between dex ≥10 mm and dex  < 10 mm in all lung regions (p < 0.05). CONCLUSION: The ITV that had no margin from GTVs increased when dex was ≥10 mm for all lung regions (p < 0.05). Furthermore, the increase in ITV tended to be greater in the lower lung lobe. These findings can help decrease the possibility of adverse events post SBRT, and correct target coverage.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Marcadores Fiduciais , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos
3.
Rep Pract Oncol Radiother ; 24(4): 383-391, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31297039

RESUMO

AIM: To investigate tumour motion tracking uncertainties in the CyberKnife Synchrony system with single fiducial marker in liver tumours. BACKGROUND: In the fiducial-based CyberKnife real-time tumour motion tracking system, multiple fiducial markers are generally used to enable translation and rotation corrections during tracking. However, sometimes a single fiducial marker is employed when rotation corrections are not estimated during treatment. MATERIALS AND METHODS: Data were analysed for 32 patients with liver tumours where one fiducial marker was implanted. Four-dimensional computed tomography (CT) scans were performed to determine the internal target volume (ITV). Before the first treatment fraction, the CT scans were repeated and the marker migration was determined. Log files generated by the Synchrony system were obtained after each treatment and the correlation model errors were calculated. Intra-fractional spine rotations were examined on the spine alignment images before and after each treatment. RESULTS: The mean (standard deviation) ITV margin was 4.1 (2.3) mm, which correlated weakly with the distance between the fiducial marker and the tumour. The mean migration distance of the marker was 1.5 (0.7) mm. The overall mean correlation model error was 1.03 (0.37) mm in the radial direction. The overall mean spine rotations were 0.27° (0.31), 0.25° (0.22), and 0.23° (0.26) for roll, pitch, and yaw, respectively. The treatment time was moderately associated with the correlation model errors and weakly related to spine rotation in the roll and yaw planes. CONCLUSIONS: More caution and an additional safety margins are required when tracking a single fiducial marker.