Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-8130593

RESUMO

The goal of image compression is to reduce the amount of data needed to represent images. In medical applications, it is not desirable to lose any information and thus lossless compression methods are often used. However, medical imaging systems have intrinsic noise associated to it. The application of a lossy technique, which acts as a low pass filter, reduces the amount of data at a higher rate without any noticeable loss in the information contained in the images. We have compressed images of nuclear medicine using the discrete cosine transform algorithm. The decompressed images were considered reliable for visual inspection. Furthermore, a parameter was computed from these images and no discernible change was found from the results obtained using the original uncompressed images.


Assuntos
Algoritmos , Imagem do Acúmulo Cardíaco de Comporta , Processamento de Imagem Assistida por Computador , Humanos , Medicina Nuclear
2.
Eur J Nucl Med ; 19(7): 484-91, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1386573

RESUMO

To determine the role of rest and stress gated technetium-99m methoxyisobutylisonitrile (sestamibi), in the detection of coronary artery disease, routine Fourier analysis of these images was performed with the best septal left anterior oblique (LAO) position of 20 patients (17 men, 3 women; aged 40-75 years) who also underwent rest or redistribution/stress single photon emission tomography (SPET) (99mTc-sestamibi and Thallium-201), gated blood pool imaging and coronary angiogram. There were 6 patients with single-vessel disease, 6 with two-vessel disease, 4 with three-vessel disease, 2 with coronary spasms, 1 with a patent graft and 1 with anginal episodes but a normal angiogram result. Three normal volunteers (2 women, 1 man; aged 24-26 years) also had rest and stress gated blood pool as well as rest and stress gated 99mTc-sestamibi imaging. Rest and stress 99mTc-sestamibi amplitude and phase images depicted regional myocardial wall shortening from the outer layer of the myocardium to the center of the left ventricle as follows: a high amplitude halo of maximal negative count rate variation; a circular thinner halo of negligible amplitude; a central region of maximal positive count rate variation, as the images evolved from end-diastole to end-systole. Similar patterns with regional differences represented abnormal myocardial wall shortening. 99mTc-sestamibi and 201Tl SPET images were in agreement in 90% of the patients and 92% of myocardial regions. 201Tl SPET detected 83% of angiographically proven lesions, as compared with 80% for 99mTc-setamibi SPET and 80% for the amplitude images. The amplitude images demonstrated a larger number of other abnormalities not predicted on the angiogram, probably because they were able to detect regions with a potential for flow improvement and transient regional wall shortening abnormalities.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Doença das Coronárias/diagnóstico por imagem , Compostos de Organotecnécio , Estresse Fisiológico/fisiopatologia , Adulto , Idoso , Angiografia Coronária , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA