Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Microfluid Nanofluidics ; 26(10): 73, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36090664

RESUMO

The last two decades witnessed a significant advancement in the field of diluted and whole blood plasma separation. This is one of the common procedures used to diagnose, cure and treat numerous acute and chronic diseases. For this separation purpose, various types of geometries of microfluidic devices, such as T-channel, Y-channel, trifurcation, constriction-expansion, curved/bend/spiral channels, a combination of any of the two geometries, etc., are being exploited, and this is detailed in this review article. The evaluation of the performance of such devices is based on the several parameters such as separation efficiency, flow rate, hematocrits, channel dimensions, etc. Thus, the current extensive review article endeavours to understand how particular geometry influences the separation efficiency for a given hematocrit. Additionally, a comparative analysis of various geometries is presented to demonstrate the less explored geometric configuration for the diluted and whole blood plasma separation. Also, a meta-analysis has been performed to highlight which geometry serves best to give a consistent separation efficiency. This article also presents tabulated data for various geometries with necessary details required from a designer's perspective such as channel dimensions, targeted component, studied range of hematocrit and flow rate, separation efficiency, etc. The maximum separation efficiency that can be achieved for a given hematocrits and geometry has also been plotted. The current review highlights the critical findings relevant to this field, state of the art understanding and the future challenges.

2.
Trans Indian Natl Acad Eng ; 7(3): 911-926, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35836614

RESUMO

Ventilation of shared indoor spaces is crucial for mitigating air-borne infection spread among its occupants. Replacing the air in a room with fresh air is key to minimize the concentration of potentially infectious aerosol generated in the room. Recirculating air flow present at corners and around obstacles can trap air and infectious aerosol. This can significantly delay their evacuation by the ventilation system. Knowing the location and extent of such recirculation zones is, therefore, important. In this work, we present flow visualization experiments to identify recirculation zones in an enclosed space. It is based on the deflection of the smoke streak generated by an incense stick. We use particle image velocimetry (PIV) post-processing to quantify the deflection of the smoke streak and use it as an indicator of the direction of local air flow. Positive deflection, defined as the deflection towards the exit location, is associated with primary flow present in well-ventilated regions of the room. On the other hand, negative deflection indicates reversed flow in recirculation zones, where the smoke streak is defined away from the exit location. The technique is applied to a public shared washroom, where the toilet seat is found to be in a well-ventilated region, while the washbasin is in a large recirculation zone. We compare the experimental point measurements with flow field solution obtained using computational fluid dynamics (CFD). We also explore geometry modifications as a strategy to eliminate the recirculation zone over the washbasin. Supplementary Information: The online version contains supplementary material available at 10.1007/s41403-022-00335-1.

3.
Langmuir ; 38(19): 6128-6147, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35507639

RESUMO

We experimentally and theoretically investigate a distinct problem of spreading, evaporation, and the associated dried deposits of a colloidal particle-laden aqueous sessile droplet on a surface in a saturated alcohol vapor environment. In particular, the effect of particle size on monodispersed suspensions and efficient self-sorting of bidispersed particles have been investigated. The alcohol vapor diffuses toward the droplet's curved liquid-vapor interface from the far field. The incoming vapor mass flux profile assumes a nonuniform pattern across the interface. The alcohol vapor molecules are adsorbed at the liquid-vapor interface, which eventually leads to absorption into the droplet's liquid phase due to the miscibility. This phenomenon triggers a liquid-vapor interfacial tension gradient and causes a reduction in the global surface tension of the droplet. This results in a solutal Marangoni flow recirculation and spontaneous droplet spreading. The interplay between these phenomena gives rise to a complex internal fluid flow within the droplet, resulting in a significantly modified and strongly particle-size-dependent dried colloidal deposit. While the smaller particles form a multiple ring pattern, larger particles form a single ring, and additional "patchwise" deposits emerge. High-speed visualization of the internal liquid-flow revealed that initially, a ring forms at the first location of the contact line. Concurrently, the Marangoni flow recirculation drives a collection of particles at the liquid-vapor interface to form clusters. Thereafter, as the droplet spreads, the smaller particles in the cluster exhibit a "jetlike" outward flow, forming multiple ring patterns. In contrast, the larger particles tend to coalesce together in the cluster, forming the "patchwise" deposits. The widely different response of the different-sized particles to the internal fluid flow enables an efficient sorting of the smaller particles at the contact line from bidispersed suspensions. We corroborate the measurements with theoretical and numerical models wherever possible.

4.
Phys Fluids (1994) ; 33(11): 117101, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34803365

RESUMO

Air-borne transmission can pose a major risk of infection spread in enclosed spaces. Venting the air out using exhaust fans and ducts is a common approach to mitigate the risk. In this work, we study the air flow set up by an exhaust fan in a typical shared washroom that can be a potential hot spot for COVID-19 transmission. The primary focus is on the regions of recirculating flow that can harbor infectious aerosol for much longer than the well-ventilated parts of the room. Computational fluid dynamics is used to obtain the steady state air flow field, and Lagrangian tracking of particles gives the spatial and temporal distribution of infectious aerosol in the domain. It is found that the washbasin located next to the door is in a prominent recirculation zone, and particles injected in this region take much longer to be evacuated. The ventilation rate is found to be governed by the air residence time in the recirculation zone, and it is much higher than the timescale based on fully mixed reactor model of the room. Increasing the fan flow rate can reduce the ventilation time, but cannot eliminate the recirculation zones in the washroom.

5.
Phys Fluids (1994) ; 33(8): 081708, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34471334

RESUMO

COVID (CoronaVirus Disease)-19, caused by severe acute respiratory syndrome-CoronaVirus-2 (SARS-CoV-2) virus, predominantly transmits via airborne route, as highlighted by recent studies. Furthermore, recently published titer measurements of SARS-CoV-2 in aerosols have disclosed that the coronavirus can survive for hours. A consolidated knowledge on the physical mechanism and governing rules behind the significantly long survival of coronavirus in aerosols is lacking, which is the subject of the present investigation. We model the evaporation of aerosolized droplets of diameter ≤ 5 µ m. The conventional diffusion-limited evaporation is not valid to model the evaporation of small size (µm-nm) droplets since it predicts drying time on the order of milliseconds. Also, the sedimentation timescale of desiccated droplets is on the order of days and overpredicts the virus survival time; hence, it does not corroborate with the above-mentioned titer-decay timescale. We attribute the virus survival timescale to the fact that the drying of small ( ∼ µ m-nm) droplets is governed, in principle, by the excess internal pressure within the droplet, which stems from the disjoining pressure due to the cohesive intermolecular interaction between the liquid molecules and the Laplace-pressure. The model predictions for the temporal reduction in the aerosolized droplet number density agree well with the temporal decay of virus titer. The findings, therefore, provide insight on the survival of coronavirus in aerosols, which is particularly important to mitigate the spread of COVID-19 from indoors.

6.
Phys Fluids (1994) ; 33(5): 052101, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34040336

RESUMO

Surface engineering is an emerging technology to design antiviral surfaces, especially in the wake of COVID-19 pandemic. However, there is yet no general understanding of the rules and optimized conditions governing the virucidal properties of engineered surfaces. The understanding is crucial for designing antiviral surfaces. Previous studies reported that the drying time of a residual thin-film after the evaporation of a bulk respiratory droplet on a smooth surface correlates with the coronavirus survival time. Recently, we [Chatterjee et al., Phys. Fluids. 33, 021701 (2021)] showed that the evaporation is much faster on porous than impermeable surfaces, making the porous surfaces lesser susceptible to virus survival. The faster evaporation on porous surfaces was attributed to an enhanced disjoining pressure within the thin-film due the presence of horizontally oriented fibers and void spaces. Motivated by this, we explore herein the disjoining pressure-driven thin-film evaporation mechanism and thereby the virucidal properties of engineered surfaces with varied wettability and texture. A generic model is developed which agrees qualitatively well with the previous virus titer measurements on nanostructured surfaces. Thereafter, we design model surfaces and report the optimized conditions for roughness and wettability to achieve the most prominent virucidal effect. We have deciphered that the optimized thin-film lifetime can be gained by tailoring wettability and roughness, irrespective of the nature of texture geometry. The present study expands the applicability of the process and demonstrates ways to design antiviral surfaces, thereby aiding to mitigate the spread of COVID-19.

7.
Phys Fluids (1994) ; 33(2): 021701, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33746485

RESUMO

Previous studies reported that the drying time of a respiratory droplet on an impermeable surface along with a residual film left on it is correlated with the coronavirus survival time. Notably, earlier virus titer measurements revealed that the survival time is surprisingly less on porous surfaces such as paper and cloth than that on impermeable surfaces. Previous studies could not capture this distinct aspect of the porous media. We demonstrate how the mass loss of a respiratory droplet and the evaporation mechanism of a thin liquid film are modified for the porous media, which leads to a faster decay of the coronavirus on such media. While diffusion-limited evaporation governs the mass loss from the bulk droplet for the impermeable surface, a much faster capillary imbibition process dominates the mass loss for the porous material. After the bulk droplet vanishes, a thin liquid film remaining on the exposed solid area serves as a medium for the virus survival. However, the thin film evaporates much faster on porous surfaces than on impermeable surfaces. The aforesaid faster film evaporation is attributed to droplet spreading due to the capillary action between the contact line and fibers present on the porous surface and the modified effective wetted area due to the voids of porous materials, which leads to an enhanced disjoining pressure within the film, thereby accelerating the film evaporation. Therefore, the porous materials are less susceptible to virus survival. The findings have been compared with the previous virus titer measurements.

8.
Langmuir ; 36(29): 8407-8421, 2020 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-32602342

RESUMO

The present study experimentally and numerically investigates the evaporation and resultant patterns of dried deposits of aqueous colloidal sessile droplets when the droplets are initially elevated to a high temperature before being placed on a substrate held at ambient temperature. The system is then released for natural evaporation without applying any external perturbation. Infrared thermography and optical profilometry are used as essential tools for interfacial temperature measurements and quantification of coffee-ring dimensions, respectively. Initially, a significant temperature gradient exists along the liquid-gas interface as soon as the droplet is deposited on the substrate, which triggers a Marangoni stress-induced recirculation flow directed from the top of the droplet toward the contact line along the liquid-gas interface. Thus, the flow is in the reverse direction to that seen in the conventional substrate heating case. Interestingly, this temperature gradient decays rapidly within the first 10% of the total evaporation time and the droplet-substrate system reaches thermal equilibrium with ambient thereafter. Despite the fast decay of the temperature gradient, the coffee-ring dimensions significantly diminish, leading to an inner deposit. A reduction of 50-70% in the coffee-ring dimensions is recorded by elevating the initial droplet temperature from 25 to 75 °C for suspended particle concentration varying between 0.05 and 1.0% v/v. This suppression of the coffee-ring effect is attributed to the fact that the initial Marangoni stress-induced recirculation flow continues until the last stage of evaporation, even after the interfacial temperature gradient vanishes. This is essentially a consequence of liquid inertia. Finally, a finite-element-based two-dimensional modeling in axisymmetric geometry is found to capture the measurements with reasonable fidelity and the hypothesis considered in the present study corroborates well with a first approximation qualitative scaling analysis. Overall, together with a new experimental condition, the present investigation discloses a distinct nature of Marangoni stress-induced flow in a drying droplet and its role in influencing the associated colloidal deposits, which was not explored previously. The insights gained from this study are useful to advance technical applications such as spray cooling, inkjet printing, bioassays, etc.

9.
J Theor Biol ; 478: 1-13, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31207204

RESUMO

Cerebral microvascular occlusions cause restriction of blood supply to the brain, thus potentially severely impacting cognitive abilities. Thus, accurate prediction of thrombus growth in realistic geometries is important. Thrombi growth in an existing 13-generation cerebral microvasculature network is simulated here to study the haemodynamic effects of single and multiple blockages on the occlusion of the network. Compared to a single vessel, in a network, the occlusion probability is found to be different. It is the downstream/smaller arterioles (i.e. the 3rd, 4th, 5th, 6th generation arterioles in this study) that tend to reach occlusion first in a network and thus are the critical vessels. Simulations of simultaneous growth of two independent thrombi in the network (referred to here as the two-block case) show a close coupling between the locations of the various blocks in the network, each influencing the other's growth. The presence of the lead block (LB) slows the growth of the trailing block (TB). In some cases, it stops the TB's growth thereby preventing it from occluding the vessel. Findings in this work thus indicate that, to prevent ischaemia, blocks in the smaller arterioles need to be identified and treated first, and that this is more critical if the number of simultaneous blocks is higher.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/patologia , Microvasos/patologia , Modelos Biológicos , Trombose/patologia , Arteríolas/fisiologia , Simulação por Computador , Constrição Patológica , Humanos , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA