Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
PLoS One ; 19(4): e0300098, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625996

RESUMO

The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/anatomia & histologia , Microtomografia por Raio-X , Imageamento Tridimensional , Estudos de Viabilidade , Reprodutibilidade dos Testes , Stents , Ultrassonografia de Intervenção , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
2.
J Invasive Cardiol ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38471151

RESUMO

An 83-year-old man who had undergone coronary aorta bypass graft surgery 25 years ago required treatment for new-onset worsening angina.

3.
Cardiovasc Interv Ther ; 39(2): 137-144, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38294663

RESUMO

The single-stent strategy has generally been accepted as the default approach to bifurcation percutaneous coronary intervention. We have proposed the proximal balloon edge dilation (PBED) technique to prevent stent deformation during side branch (SB) dilation. This bench study aimed to evaluate the impact of stent link location and stent design on stent deformation, obstruction by stent struts at a jailed SB ostium, and incomplete stent apposition in the proximal optimization technique (POT)-PBED procedure. A coronary bifurcation model was used. We intentionally set the absence or presence of stent link on the carina (link-free or link-connect) under videoscope observation and compared stent parameters between 3- and 2-link stents (n = 5 each, n = 20 total). In the link-free group, the SB jailing rate of 3-link stents was significantly higher than that of 2-link stents (15.5 ± 5.1% vs. 6.6 ± 1.2%, p = 0.009). In the link-connect group, the SB jailing rate of 3-link stents was significantly lower than that of 2-link stents (30.0 ± 4.5% vs. 39.0 ± 2.6%, p = 0.009). In the bifurcation segment, the rate of incomplete stent apposition was significantly lower for 3-link stents of the link-connect group than for 2-link stents of the link-connect group (3.3 ± 4.2% vs. 19.0 ± 7.8%, p = 0.009). For both stent designs, ellipticity ratio was higher for link-connect group than link-free group. Link location as well as stent cell design greatly impacted stent deformation during the POT-PBED procedure.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Dilatação , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Resultado do Tratamento , Stents/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Angiografia Coronária/métodos
4.
Int J Cardiol Heart Vasc ; 49: 101311, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38076349

RESUMO

Background: Intracoronary imaging improves clinical outcomes after stenting of complex coronary bifurcation lesions (CBLs), but the impact of Medina classification-based CBL distribution on outcomes of imaging-guided bifurcation stenting is unclear. Methods: In this integrated analysis of four previous studies, in which all CBLs were treated with drug-eluting stents under intravascular ultrasound or optical coherence tomography guidance, the distribution of 763 CBLs was assessed using angiographic Medina classification. Major adverse cardiac events (MACE), including target lesion revascularization (TLR), myocardial infarction, stent thrombosis, and cardiac death, were investigated at 1-year follow-up. Results: The most and least prevalent Medina subtypes were 0-1-0 (27.9 %) and 0-0-1 lesions (2.8 %). The most and least frequent MACE/TLR rates were 18.2 %/18.2 % for 0-0-1 lesions and 4.1 %/2.8 % for 0-1-0 lesions. Risks were higher for 0-0-1 lesions than for 0-1-0 lesions for both MACE (hazard ratio [HR]: 4.04, 95 % confidence interval [CI]: 1.21-13.45, p = 0.02) and TLR (HR: 6.19, 95 % CI: 1.69-22.74, p = 0.006). MACE rates were similar for true and non-true CBLs excluding 0-0-1 lesions (8.2 % and 5.9 %, HR 1.54, 95 % CI: 0.86-2.77, p = 0.15), while MACE (HR: 3.25, 95 % CI: 1.10-9.63, p = 0.03) and TLR (HR: 4.24, 95 % CI: 1.38-12.96, p = 0.01) risks were higher for 0-0-1 lesions. Conclusions: This integrated analysis of imaging-guided bifurcation stenting demonstrated similar clinical outcomes in true and non-true CBLs, except for 0-0-1 lesions, which had a significantly higher risk of MACE/TLR.

5.
Circ J ; 2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37839862

RESUMO

BACKGROUND: Side branch (SB) occlusion during bifurcation stenting is a serious complication. This study aimed to predict SB compromise (SBC) using optical coherence tomography (OCT).Methods and Results: Among the 168 patients who enrolled in the 3D-OCT Bifurcation Registry, 111 bifurcation lesions were analyzed to develop an OCT risk score for predicting SBC. SBC was defined as worsening of angiographic SB ostial stenosis (≥90%) immediately after stenting. On the basis of OCT before stenting, geometric parameters (SB diameter [SBd], length from proximal branching point to carina tip [BP-CT length], and distance of the polygon of confluence [dPOC]) and 3-dimensional bifurcation types (parallel or perpendicular) were evaluated. SBC occurred in 36 (32%) lesions. The parallel-type bifurcation was significantly more frequent in lesions with SBC. The receiver operating characteristic curve indicated SBd ≤1.77 mm (area under the curve [AUC]=0.73, sensitivity 64%, specificity 75%), BP-CT length ≤1.8 mm (AUC=0.83, sensitivity 86%, specificity 68%), and dPOC ≤3.96 mm (AUC=0.68, sensitivity 63%, specificity 69%) as the best cut-off values for predicting SBC. To create the OCT risk score, we assigned 1 point to each of these factors. As the score increased, the frequency of SBC increased significantly (Score 0, 0%; Score 1, 8.7%; Score 2, 28%; Score 3, 58%; Score 4, 85%; P<0.0001). CONCLUSIONS: Prediction of SBC using OCT is feasible with high probability.

6.
JACC Cardiovasc Interv ; 16(20): 2479-2497, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37879802

RESUMO

Artificial intelligence, computational simulations, and extended reality, among other 21st century computational technologies, are changing the health care system. To collectively highlight the most recent advances and benefits of artificial intelligence, computational simulations, and extended reality in cardiovascular therapies, we coined the abbreviation AISER. The review particularly focuses on the following applications of AISER: 1) preprocedural planning and clinical decision making; 2) virtual clinical trials, and cardiovascular device research, development, and regulatory approval; and 3) education and training of interventional health care professionals and medical technology innovators. We also discuss the obstacles and constraints associated with the application of AISER technologies, as well as the proposed solutions. Interventional health care professionals, computer scientists, biomedical engineers, experts in bioinformatics and visualization, the device industry, ethics committees, and regulatory agencies are expected to streamline the use of AISER technologies in cardiovascular interventions and medicine in general.


Assuntos
Inteligência Artificial , Humanos , Resultado do Tratamento
8.
Int J Cardiol Heart Vasc ; 48: 101265, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37680550

RESUMO

Background: The impact of coronary bifurcation angle (BA) on incomplete stent apposition (ISA) after crossover stenting followed by side branch (SB) intervention has not been established. Methods: A total of 100 crossover stentings randomly treated with proximal optimization technique followed by short balloon dilation in the SB (POT-SBD group, 48 patients) and final kissing balloon technique (KBT group, 52 patients) were analyzed in the PROPOT trial. Major ISA with maximum distance > 400 µm and its location was determined using optical coherence tomography before SB intervention and at the final procedure. The BA was defined as the angle between the distal main vessel and SB. Optimal POT was determined when the difference in stent volume index between the proximal and distal bifurcation was greater than the median value (0.86 mm3/mm) before SB intervention. Result: Major ISA was more frequently observed in the POT-SBD than in the KBT group (35% versus 17%, p < 0.05). In the POT-SBD group, worsening ISA after SBD was prominent at the distal bifurcation. The BA was an independent predictor of major ISA (odds ratio 1.04, 95% confidence interval 1.00-1.07, p < 0.05) with a cut-off value of 59.5° (p < 0.05). However, the cases treated with optimal POT in the short BA (<60°) indicated the lowest incidence of major ISA. In the KBT group, BA had no significant impact. Conclusion: A wide BA has a potential risk for the occurrence of major ISA after POT followed by SBD in coronary bifurcation stenting.

9.
Int J Cardiovasc Imaging ; 39(8): 1593-1603, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37191834

RESUMO

PURPOSE: We aimed to investigate the serial change of the side-branch ostial area (SBOA) depended on the wire-position before Kissing-balloon inflation (KBI) in the single-stent strategy for bifurcation lesions separately in the left main coronary artery (LMCA) and in non-LMCA. METHODS: Patients who underwent a single-stent KBI for a bifurcation lesion and had OCT images at the timing of the rewiring, at the post-procedure, and at the 9-month follow-up were extracted from the 3D-OCT Bifurcation Registry, which is a multicenter-prospective registry of patients with a percutaneous coronary intervention for a bifurcation lesion under OCT guidance. The SBOA was measured by dedicated software, and the rewiring position at the side-branch ostium after crossover stenting was assessed by three-dimensional-optical coherence tomography (3D-OCT). The optimal rewiring was defined as link-free-type and distal rewiring. The relationship between the optimal rewiring and the serial change of the SBOA was investigated separately in LMCA and non-LMCA cases. RESULTS: We examined 75 bifurcation lesions (LMCA, n = 35; non-LMCA, n = 40). The serial changes of the SBOA with the optimal rewiring were not significantly different regardless of LMCA and non-LMCA (LMCA:3.96 to 3.73 mm2, p = 0.38; non-LMCA:2.16 to 2.21 mm2, p = 0.98), whereas the serial changes of the SBOA with the sub-optimal rewiring were significantly reduced (LMCA:6.75 to 5.54 mm2, p = 0.013; non-LMCA:2.28 mm2 to 2.09 mm2, p = 0.024). There was no significant difference in clinical events between the optimal and sub-optimal rewiring group regardless of the LMCA and non-LMCA. CONCLUSION: The side-branch ostial area dilated with the optimal rewiring position in a bifurcation lesion treated with single crossover stenting and kissing-balloon inflation was preserved regardless of whether the bifurcation was in the LMCA or a non-LMCA.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Valor Preditivo dos Testes , Stents , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Tomografia de Coerência Óptica/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/patologia , Angiografia Coronária/métodos , Resultado do Tratamento
10.
Int J Cardiovasc Imaging ; 39(7): 1375-1382, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37119348

RESUMO

Coronary stent underexpansion is associated with restenosis and stent thrombosis. In clinical studies of atherosclerosis, high wall shear stress (WSS) has been associated with activation of prothrombotic pathways, upregulation of matrix metalloproteinases, and future myocardial infarction. We hypothesized that stent underexpansion is predictive of high WSS. WSS distribution was investigated in patients enrolled in the prospective randomized controlled study of angulated coronary arteries randomized to undergo percutaneous coronary intervention with R-ZES or X-EES. WSS was calculated from 3D reconstructions of arteries from intravascular ultrasound (IVUS) and angiography using computational fluid dynamics. A logistic regression model investigated the relationship between WSS and underexpansion and the relationship between underexpansion and stent platform. Mean age was 63±11, 78% were male, 35% had diabetes, mean pre-stent angulation was 36.7°±14.7°. Underexpansion was assessed in 83 patients (6,181 IVUS frames). Frames with stent underexpansion were significantly more likely to exhibit high WSS (> 2.5 Pa) compared to those without underexpansion with an OR of 2.197 (95% CI = [1.233-3.913], p = 0.008). There was no significant association between underexpansion and low WSS (< 1.0 Pa) and no significant differences in underexpansion between R-ZES and X-EES. In the Shear Stent randomized controlled study, underexpanded IVUS frames were more than twice as likely to be associated with high WSS than frames without underexpansion.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Valor Preditivo dos Testes , Stents , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Estresse Mecânico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
11.
J Cardiol Cases ; 27(1): 36-40, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36618839

RESUMO

Impella ™ (Abiomed, Danvers, MA, USA) is effective in the acute management of fulminant myocarditis and myocardial infarction with cardiogenic shock. Here, we report a case of a 70-year-old man with fulminant myocarditis in cardiogenic shock who developed right-left shunt via patent foramen ovale during acute management with Impella 5.0, resulting in sudden hypoxemia. With combined support of veno-arterial extracorporeal membrane oxygenation and Impella (ECPELLA), his circulation and oxygenation became stable. The same phenomenon is well known in left ventricular assist device. In such situations, ECPELLA is effective to improve the hypoxic condition. It should be kept in mind that hypoxemia can occur in patients with intracardiac shunt disease when using Impella. Learning objective: Impella is effective to maintain circulation in patients with cardiogenic shock; however, several complications have been reported. Intra-cardiac shunt can suddenly cause severe hypoxemia by Impella. We should mention the presence of intra-cardiac shunt, if the patients have sudden hypoxemia when using left ventricular assist.

12.
J Invasive Cardiol ; 34(12): E888-E889, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36476823

RESUMO

In this 69-year-old patient, a complex left main quadrifurcation lesion was treated with a stentless procedure, which resulted in sufficient dilation in each branch. Dual-antiplatelet therapy was continued for 3 months, followed by aspirin alone. The stentless treatment with DCB after sufficient plaque debulking with DCA can be useful in avoiding long-term dual antiplatelet therapy especially in patients with high-bleeding risk or those who plan to undergo the non-cardiac operation.


Assuntos
Cardiopatias , Inibidores da Agregação Plaquetária , Idoso , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Cardiopatias/terapia
13.
Front Cardiovasc Med ; 9: 1023834, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36440010

RESUMO

Imaging-guided coronary bifurcation intervention has improved clinical outcomes due to the appropriate size selection of the devices and optimization of the procedure (sufficient stent expansion, reduction of stent malapposition, appropriate stent landing zone, and detection of vessel dissection). In particular, three-dimensional optical coherence tomography (3D OCT) facilitates clear visualization of stent configuration and guidewire position, which promotes optimal guidewire crossing to the side branch. Successive side branch dilation leads to wide ostial dilation with less strut malapposition. However, the link connection of the stent located on the bifurcated carina has been found to be an impediment to sufficient opening of the side branch, resulting in incomplete strut apposition. In such cases, the aggressive proximal optimization technique improves the jailing strut pattern, and 3D OCT navigates the guidewire crossing to the optimal cell that is most likely to be expanded sufficiently, which is not always a distal cell. In two-stent deployment, 3D OCT facilitates optimal guidewire crossing, which leads to less metallic carina, clustering, and overlapping. The present review describes a method of clear visualization and assessment with 3D OCT and discusses the efficacy of 3D OCT in coronary bifurcation stenting in clinical practice.

14.
PLoS One ; 17(8): e0273157, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35976920

RESUMO

BACKGROUND: A coronary bifurcation stenting is still a challenging issue due to frequent restenosis and stent thrombosis even with drug-eluting stents. The bifurcation angle (BA) between a main vessel and a side branch is one of the crucial determinants of coronary flow and shear stress that affect the plaque distribution. Previous bench and clinical studies have evaluated the impact of the BA between the proximal main vessel and the side branch (Angle A) and the BA between the distal main vessel and the side branch (Angle B) on the clinical outcomes of bifurcation stenting. However, the impact has not yet been fully elucidated due to a lack of statistical power or different manner of the assessment of BA. OBJECTIVES: To analyze the published studies on coronary artery BA, the modalities used for assessment, and the impact of BA on interventions and attempt to define the pre-procedural protocols. DATA SOURCES: A scoping review was performed using the Joanna Briggs Institute Methodology. A total of 52 relevant references were selected from PubMed, Cochrane Library, and CINAHL databases and categorized into three topic areas. RESULTS AND CONCLUSIONS: A wider Angle A is associated with the increased likelihood of carina shift and a wider Angle B, with that of side branch occlusion. A wider Angle B promotes stent malapposition and deformation in the side branch ostium and has been reported as an independent predictor of major adverse cardiac events after bifurcation stenting; however, improvement of the drug-eluting stent, refinement of the stenting technique, and accurate 3-dimensional assessment may attenuate the adverse clinical impact of a wider BA. IMPLICATIONS OF KEY FINDINGS: Assessment of the BA is necessary to predict the effect of bifurcation intervention procedure on the stent configuration and coronary flow at the bifurcated vessels. This will help to optimize stent selection and the stenting technique.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Stents Farmacológicos , Aterosclerose/patologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Stents Farmacológicos/efeitos adversos , Coração , Humanos , Stents/efeitos adversos , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 15(13): 1297-1309, 2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35717395

RESUMO

Coronary artery bifurcation lesions are frequently encountered in cardiac catheterization laboratories and are associated with more complex procedures and worse clinical outcomes than nonbifurcation lesions. Therefore, anatomical and physiological assessment of bifurcation lesions before, during, and after percutaneous coronary intervention is of paramount clinical importance. Physiological assessment can help interventionalists appreciate the hemodynamic significance of coronary artery disease and guide ischemia-directed revascularization. However, it is important to understand that the physiological approach for bifurcation disease is more important than simply using physiological indexes for its assessment. This joint consensus document by the Korean, Japanese, and European bifurcation clubs presents the concept of a physiological approach for coronary bifurcation lesions, as well as current knowledge, practical tips, pitfalls, and future directions of applying physiological indexes in bifurcation percutaneous coronary intervention. This document aims to guide interventionalists in performing appropriate physiology-based assessments and treatment decisions for coronary bifurcation lesions.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Japão , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , República da Coreia , Resultado do Tratamento
17.
Int J Cardiol Heart Vasc ; 40: 101034, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35495581

RESUMO

Background: The jailing strut configuration with link-free and distal guidewire recrossing (LFD) at the side branch orifice (SBO) reduces incomplete stent apposition (ISA) after kissing balloon technique (KBT) in crossover stenting of coronary bifurcation lesions (CBLs). However, data regarding vascular healing after KBT are lacking. We investigated vascular healing 9 months after crossover stenting followed by KBT with optical coherence tomography (OCT) guidance in a prospective multicenter registry. Methods: Fifty-nine patients with CBLs (LFD, 35 patients; non-LFD, 24 patients) were studied. The jailing configuration of the SB and the wire-recrossing position, incidence of ISA and uncovered struts, and neointima unevenness score (NUS) in the main vessel (MV) after 9 months were determined by off-line 3D-OCT in the core laboratory. Results: The ISA rate was significantly higher at the SB ostium and distal MV after KBT in the non-LFD group, compared to the LFD group. After 9 months, incidence of ISA (18.3 ± 18.2 vs. 6.0 ± 8.7%, p < 0.01) and uncovered struts (8.7 ± 9.9 vs. 4.7 ± 7.3 %, p = 0.08) were higher at the SB ostium with higher SB restenosis in the non-LFD group. In distal MV, NUS was significantly higher (3.1 ± 1.1 vs. 2.5 ± 0.6, p < 0.05). In true-CBLs, an increase in uncovered struts and ISA rate was prominent in the proximal MV and opposite SB. No differences were observed in the 9-month clinical outcomes. Conclusion: Visualization of the wire recrossing point and the SB-jailing strut pattern by OCT plays an important role to optimize the KBT in CBL stenting, resulting in favorable mid-term vascular healing.

18.
Catheter Cardiovasc Interv ; 99(4): 1047-1058, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35170843

RESUMO

OBJECTIVE: We investigated the effect of proximal optimization technique (POT) on coronary bifurcation stent failure (BSF) in cross-over stenting by comparing with the kissing balloon technique (KBT) in a multicenter randomized PROPOT trial. BACKGROUND: POT is recommended due to increased certainty for optimal stent expansion and side branch (SB) wiring. METHODS: We randomized 120 patients treated with crossover stenting into the POT group, which was followed by SB dilation (SBD), and the KBT group. Finally, 52 and 57 patients were analyzed by optical coherence tomography before SBD and at the final procedure, respectively. Composite BSF was defined as a maximal malapposition distance of >400 µm, or malapposed and SB-jailed strut rates of >5.95% and >21.4%, respectively. RESULTS: Composite BSF before SBD in the POT and KBT groups was observed in 29% and 26% of patients, respectively. In the POT group, differences in stent volumetric index between the proximal and distal bifurcation (odds ratio [OR] 60.35, 95% confidential interval [CI] 0.13-0.93, p = 0.036) and between the proximal bifurcation and bifurcation core (OR: 3.68, 95% CI: 1.01-13.40, p = 0.048) were identified as independent risk factors. Composite BSF at final in 27% and 32%, and unplanned additional procedures in 38% and 25% were observed, respectively. Composite BSF before SBD was a risk factor for the former (OR: 6.33, 95% CI: 1.10-36.50, p = 0.039) and the latter (OR: 6.43, 95% CI: 1.25-33.10, p = 0.026) in the POT group. CONCLUSION: POT did not result in a favorable trend in BSF. Insufficient expansion of the bifurcation core after POT was associated with BSF.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Insuficiência Cardíaca , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...