Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem Toxicol ; 48(8-9): 2429-34, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20566341

RESUMO

Apple juice samples intended for infants purchased in Navarra (Spain) have been analyzed for PAT occurrence. Two capillary electrophoresis methods, based on a MEKC and a CEC system, and an HPLC method were evaluated for the aforementioned study. The CEC system gave less satisfying separations and several practical problems, so samples have been analyzed by MEKC and HPLC. Both methods have been comparable in terms of recovery, precision, limits of detection, volume of organic solvents used and adequate selectivity with regard to PAT and HMF. The analysis time in HPLC has been slightly lower than in the MEKC methodology. The PAT levels obtained in apple juice by both validated methods showed a strong correlation (p<0.001). Therefore, both methodologies are useful for the accurate quantification of patulin in this matrix. The PAT levels obtained in the 20 infant apple juices samples were in a range between

Assuntos
Bebidas/análise , Alimentos Infantis/análise , Malus/química , Micotoxinas/análise , Patulina/análise , Cromatografia Líquida de Alta Pressão , Eletroforese Capilar , Humanos , Indicadores e Reagentes , Lactente , Recém-Nascido , Padrões de Referência , Reprodutibilidade dos Testes , Solventes
2.
Toxins (Basel) ; 2(5): 1054-64, 2010 05.
Artigo em Inglês | MEDLINE | ID: mdl-22069625

RESUMO

The mycotoxin ochratoxin A (OTA) has toxic effects in animals; the most relevant of them is nephrotoxicity. OTA has also been classified as a possible carcinogen for humans (group 2B) by the International Agency for Research on Cancer (IARC). Therefore, exposure to OTA through contaminated food can represent health impairment to humans. The maximum permitted level for this mycotoxin in wine is 2.0 µg/L. The presence of OTA in Spanish wines produced using the traditional methods under the Denomination of Origin "Jerez-Xérès-Sherry andmanzanilla Sanlúcar de Barrameda" was evaluated by a High performance Liquid Chromatography method with fluorescence detection and immunoaffinity column purification. A recovery of 95.4% and a limit of detection and quantification of 0.009 µg/L and 0.02 µg/L respectively, were achieved. In manzanilla, fino, amontillado and oloroso wine, the mean OTA values were 0.042, 0.044, 0.144, and 0.319 µg/L, respectively. These levels are not different from other data given in the reference literature on white wines, although fino and manzanilla wines have very low OTA levels.


Assuntos
Contaminação de Alimentos/análise , Ocratoxinas/isolamento & purificação , Vinho/análise , Carcinógenos/análise , Cromatografia Líquida de Alta Pressão , Limite de Detecção , Reprodutibilidade dos Testes , Espanha
3.
J Food Prot ; 71(7): 1422-6, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18680942

RESUMO

Ochratoxin A (OTA) is a mycotoxin produced by Aspergillus and Penicillium species, which contaminates cocoa among other food commodities. It has been previously demonstrated that the toxin is concentrated in cocoa shells. The aim of this study was to assay a simple chemical method for ochratoxin A reduction from naturally contaminated cocoa shells. In order to determine the efficiency of the method, a high-performance liquid chromatography method with fluorescence detection was set up beforehand and validated. Ochratoxin A was extracted from cocoa shells with methanol-3% sodium bicarbonate solution and then purified with immunoaffinity columns. The recovery attained was 88.7% (relative standard deviation = 6.36%) and the limits of detection and quantification were 0.06 and 0.2 kg/kg, respectively. For decontamination experiments, the solvent extractor ASE 200 was used. First, aqueous solutions of 2% sodium bicarbonate and potassium carbonate were compared under the same conditions (1,500 lb/in2 at 40 degrees C for 10 min). Higher ochratoxin A reduction was obtained with potassium carbonate (83 versus 27%). Then, this salt was used under different conditions of pressure, temperature, and time. The greatest ochratoxin A reduction was achieved with an aqueous potassium carbonate solution (2%), at 1,000 lb/in2 at 90 degrees C for 10 min. This method could probably be applicable to the cocoa industry because it is fast and relatively economic. From the point of view of human health, the use of potassium carbonate, partially eliminated by rinsing the sample with water, does not likely represent a risk for human health.


Assuntos
Cacau/química , Carbonatos/farmacologia , Contaminação de Alimentos/análise , Manipulação de Alimentos/métodos , Ocratoxinas/isolamento & purificação , Potássio/farmacologia , Cromatografia Líquida de Alta Pressão/métodos , Relação Dose-Resposta a Droga , Fluorescência , Análise de Alimentos , Contaminação de Alimentos/prevenção & controle , Humanos , Pressão Hidrostática , Temperatura , Fatores de Tempo
4.
Food Chem Toxicol ; 46(6): 2251-7, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18430505

RESUMO

A microemulsion electrokinetic chromatography (MEECK) method for patulin (PAT) quantification in apple juice samples has been developed. The effects of several important factors such as co-surfactant type, concentration of surfactant, acetonitrile percentage in the microemulsion, and running voltage and temperature were investigated to determine the optimum conditions. They resulted to be: a background electrolyte (BGE) composed of 25mM of sodium tetraborate, SDS (2.16%w/w), ethanol (6.49%w/w), n-octanol (0.82%w/w) and 2%v/v acetonitrile; applied voltage of +15kV; and a capillary temperature of 35 degrees C. PAT was detected at 276nm. Quantification and detection limits (LOQ and LOD) in apple juice samples were 8.0microgL(-1) and 3.2microgL(-1), respectively. Patulin was extracted from apple juice using ethyl acetate with a mean recovery value of 75.3% (RSD=4.5). This method was applied to the measurement of patulin in twenty commercial apple juice samples obtained from different Danish supermarkets. The PAT apple juice mean and median levels obtained were 35.9 and 10.9microgL(-1), respectively. The comparison with a previously validated micellar electrokinetic chromatography (MEKC) method for PAT analysis showed the suitability of using MEEKC for this mycotoxin analysis. However, the expectations of obtaining a higher efficiency and thus lower limits of detection and quantitation when using MEEKC were not met.


Assuntos
Bebidas/análise , Carcinógenos/análise , Malus/química , Patulina/análise , Calibragem , Cromatografia Capilar Eletrocinética Micelar , Dinamarca , Emulsões , Padrões de Referência , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta
5.
Lett Appl Microbiol ; 47(3): 197-201, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19552785

RESUMO

AIMS: The aim of this study was to identify fungal populations in unroasted cocoa beans stored in Spain in order to evaluate the ochratoxin A (OTA)-production ability of certain Aspergillus isolates. METHODS AND RESULTS: Twenty batches of cocoa beans from different origins and with different OTA content were selected for this study. Three Aspergillus carbonarius and 13 Aspergillus niger aggregate strains isolated from these cocoa bean samples were selected to evaluate their OTA synthesis ability, being the only A. carbonarius isolates which are OTA producers [

Assuntos
Aspergillus/isolamento & purificação , Cacau/microbiologia , Ocratoxinas/biossíntese , Aspergillus/patogenicidade , Ocratoxinas/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA